Search NASA⌕ Search

SEARCH · Search NASA

Results for “power sharing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the Impact of Near-Term Innovations on the Technical Potential of Land-Based Wind Energy

Land based wind may play a critical role in reaching emissions reductions goals and high renewable contribution scenarios with capacity expansion modeling results estimating over 1 terawatt of land-based wind by 2035 to reach 100% clean electricity. Deployment of land-based wind at this magnitude may require significant investments in transmission infrastructure and will require significant land area for new wind and transmission. Cost reductions via technological advancements in wind turbine design, construction, and maintenance will have a major role in enabling the scale of deployment required. Since 1998, the levelized cost of wind energy has fallen by over 60% due to improvements in capacity factors, advancements in turbine controls, and cost reductions in installation, operation, and maintenance. These cost reduction pathways, generally referred to as wind technology "innovations", have enabled significant increases in the capacity and electric generation share of wind power in the United States. Nevertheless, achievements of past wind innovations have not led to widespread wind deployment outside of high wind speed geographies. This study evaluates the potential of near-term innovations to expand the geographic range of economically viable land-based wind power production in the United States. Many challenges to future deployment of wind power can be associated with increasing concentration in high-wind areas. As more wind power is deployed in these same areas, it is likely that residential and regulatory resistance to further deployment will increase, access to transmission will diminish, and options for distant companies and governments with renewable energy goals will remain limited. Therefore, this analysis aims to emphasize the potential for innovations to enable land-based wind in regions with limited wind deployment and with lower wind resource and better access to transmission.

17 WIND ENERGY↗

Tough Break: Many Factors Make Glass Breakage More Likely

We have seen cases of glass in PV modules breaking differently, and more often, than it did five years ago. There have been many changes to PV module design and materials in that time. But there is probably no single change that is responsible for the problem. Here we summarize the current thinking on PV glass breakage in utility-scale power plants. We share insights from multiple still-running projects at NREL.

14 SOLAR ENERGY↗

Investigation of onshore wind farm wake recovery with in situ aircraft measurements during AWAKEN

The share of wind power for electricity supply is increasing worldwide. This highly variable resource requires the improved prediction of power output for network stability. The interaction between wind farm wakes and the atmospheric boundary layer (ABL) introduces uncertainties in power production that warrant detailed investigation. The flow downwind of wind farms is characterized by a reduction in wind speed and an increase in turbulence, which both vary with atmospheric conditions. During the American WAKE experimeNt (AWAKEN), the Technische Universität Braunschweig conducted measurement flights with a research aircraft upwind and downwind of onshore wind farms in the southern Great Plains in Oklahoma in the USA. This study utilizes data from 20 flights conducted at approximately hub height in September 2023 to investigate the wind field variability downwind of the wind farms and vertical profiles to observe atmospheric stratification. The flights were aligned perpendicular to the main wind direction downwind of the King Plains and Armadillo Flats wind farms. Additionally, lidar data from both upwind and downwind ground-based measurement sites and sonic anemometer data were used for comprehensive analysis. Results indicate that under stable ABL conditions, the wake persists at greater downwind distances with a higher velocity deficit in the wake relative to the undisturbed flow compared to unstable stratification. In homogeneous terrain under stable conditions, wake recovery to 95 % occurs between a distance of 4.5 and 9 km downwind of the wind farm. In the semi-complex terrain characterized by shallow hills, slopes, and valleys, the wake exhibits a higher velocity deficit compared to homogeneous terrain, while in some cases the wake was amplified by the terrain resulting in higher velocity deficit 10 km downwind of the wind farm compared to the measurements closer to the wind farm. The turbulent kinetic energy (TKE) and “TKE difference” was found to be a valuable measure in understanding wakes in a semi-complex terrain, showing a clear wake recovery and formation depending on the stratification of the ABL.

17 WIND ENERGY↗

Time-shaped RF brazing

One RF generator is controlled from two independent work stations with aid of RF switch and simple control boxes. Brazing may be stopped manually or automatically by external brazing-temperature controller or timer in RF switch housing. Switch is air-operated with water-cooled contacts. If switch loses air pressure, generator stops transmitting power. Time-shared outlet increases utilization and productivity of costly RF generator.

Stein, J. A.↗

Advanced propulsion system for hybrid vehicles

A number of hybrid propulsion systems were evaluated for application in several different vehicle sizes. A conceptual design was prepared for the most promising configuration. Various system configurations were parametrically evaluated and compared, design tradeoffs performed, and a conceptual design produced. Fifteen vehicle/propulsion systems concepts were parametrically evaluated to select two systems and one vehicle for detailed design tradeoff studies. A single hybrid propulsion system concept and vehicle (five passenger family sedan)were selected for optimization based on the results of the tradeoff studies. The final propulsion system consists of a 65 kW spark-ignition heat engine, a mechanical continuously variable traction transmission, a 20 kW permanent magnet axial-gap traction motor, a variable frequency inverter, a 386 kg lead-acid improved state-of-the-art battery, and a transaxle. The system was configured with a parallel power path between the heat engine and battery. It has two automatic operational modes: electric mode and heat engine mode. Power is always shared between the heat engine and battery during acceleration periods. In both modes, regenerative braking energy is absorbed by the battery.

Norrup, L. V.↗

Dynamical Studies of the Middle Atmosphere Using High Resolution Doppler Imager Observations

This report summarizes the activities of NASA grant NAG5-11068, "Dynamicai Studies of the Middle Atmosphere Using High Resolution Doppler Imager Observations." The High Resolution Doppler Imager (HRDI) on the Upper Atmosphere Research Satellite (UARS) has been providing direct measurements of the Earth's horizontal wind field in the stratosphere, mesosphere and lower thermosphere. Mesospheric temperatures, ozone, and O((sup 1) D) densities, and stratospheric aerosol extinctions coefficients, are also retrieved. The goal of HRDI is to measure the vector winds in the stratosphere (10-40 km), mesosphere, and lower thermosphere (approximately 50-120 km) during the day, and the lower thermosphere at night (approximately 95 km) to an accuracy of 5 m/s. The horizontal wind vector is measured by observing the Doppler shift of rotational lines of molecular oxygen along two lines of sight. In addition to winds, temperatures and volume emission rates are determined in the mesosphere and lower thermosphere, from which ozone and O((sup 1) D) concentrations can be derived, and aerosol scattering coefficients are determined in the stratosphere. UARS was launched on September 12, 1991, into a 585-km circular orbit inclined 57 degrees to the equator HRDI was activated September 28, 1991 and following a period of checkout and adjustment of the instrument parameters, scientific observations began November 2, 199 1. HRDI operated nearly continuously from launch until April 1995. At that time the UARS solar array drive failed, forcing the instruments to time-share the available power. From July 1995 to July 1996 HRDI operated approximately 50% of the time. At that point, one of the three spacecraft batteries failed and from then until September 1998 the duty cycle was less than 20% per month, At that time it was determined that HRDI could operate during each daytime pass, which increased the daytime duty cycle to close to l00%, while nighttime operations were limited to about a week per month. In the fall of 1999, the second tape recorder failed requiring a real time contact with a TRDSS satellite to retrieve that data. This resulted in about 60% data collection efficiency. Finally, in the summer of 2000, the second star sensor failed requiring the spacecraft attitude to be controlled by a three axis magnetometer and sun sensor. This resulted in a loss of attitude knowledge but operations continue with the anticipation of correcting the attitude. A new method for determining the tide and mean structure from satellite data in conjunction with a new tidal model has been devised. For brevity, it shall be referred to as the TMAT or Tide-Mean Assimilation Technique. Most previous methods of tidal analysis are based on various ways of slicing the data set.

Skinner, Wilbert↗

Modeling Integrated Electricity and Natural Gas Systems Using Co-Simulation

One approach for modeling natural gas and electricity networks as integrated systems is co-simulation, which involves separating a single model into subproblems that are solved iteratively, with coupling information passed between then. Although a fully integrated problem might be more direct, co-simulation offers advantages in that it can sometimes be more computationally tractable, and can also leverage existing simulation tools to represent the subproblems. Here we present a framework for co-simulation of natural gas and electricity networks using the HELICS tool. We provide validation of the co-simulation approach by comparing results with a fully integrated approach that uses the same simulation tool, finding that the two approaches provide identical results for a range of test cases. We then present results from natural gas and electricity network co-simulation case study of the Colorado Front Range, with an evaluation of the present-day system and also a future system with higher shares of renewable power. The presentation will close with a discussion on future avenues of work for co-simulation of gas and power networks.

co-simulation↗

Nuclear concepts/propulsion

Nuclear thermal and nuclear electric propulsion systems will enable and/or enhance important space exploration missions to the moon and Mars. Current efforts are addressing certain research areas, although NASA and DOE still have much work yet to do. Relative to chemical systems, nuclear thermal propulsion offers the potential of reduced vehicle weight, wider launch windows. and shorter transit times, even without aerobrakes. This would improve crew safety by reducing their exposure to cosmic radiation. Advanced materials and structures will be an important resource in responding to the challenges posed by safety and test facility requirements, environmental concerns, high temperature fuels and the high radiation, hot hydrogen environment within nuclear thermal propulsion systems. Nuclear electric propulsion (NEP) has its own distinct set of advantages relative to chemical systems. These include low resupply mass, the availability of large amounts of onboard electric power for other uses besides propulsion, improved launch windows, and the ability to share technology with surface power systems. Development efforts for NEP reactors will emphasize long life operation of compact designs. This will require designs that provide high fuel burnup and high temperature operation along with personnel and environmental safety.

Miller, Thomas J.↗

Factors affecting frequency and orbit utilization by high power transmission satellite systems

The factors affecting the sharing of the geostationary orbit by high power (primarily television) satellite systems having the same or adjacent coverage areas and by satellites occupying the same orbit segment are examined and examples using the results of computer computations are given. The factors considered include: required protection ratio, receiver antenna patterns, relative transmitter power, transmitter antenna patterns, satellite grouping, and coverage pattern overlap. The results presented indicated the limits of system characteristics and orbit deployment which can result from mixing systems.

Kuhns, P. W.↗

Factors affecting frequency and orbit utilization by high power transmission satellite systems.

The factors affecting the sharing of the geostationary orbit by high power (primarily television) satellite systems having the same or adjacent coverage areas and by satellites occupying the same orbit segment are examined and examples using the results of computer computations are given. The factors considered include: required protection ratio, receiver antenna patterns, relative transmitter power, transmitter antenna patterns, satellite grouping, and coverage pattern overlap. The results presented indicate the limits of system characteristics and orbit deployment which can result from mixing systems.

Kuhns, P. W.↗

Factors affecting frequency and orbit utilization by high power transmission satellite systems

The factors affecting the sharing of the geostationary orbit by high power (primarily television) satellite systems having the same or adjacent coverage areas and by satellites occupying the same orbit segment are examined and examples using the results of computer computations are given. The factors considered include: required protection ratio, receiver antenna patterns, relative transmitter power, transmitter antenna patterns, satellite grouping, and coverage pattern overlap. The results presented indicate the limits of system characteristics and orbit deployment which can result from mixing systems.

Kuhns, P. W.↗

Orbital transfer of large space structures with nuclear electric rockets

This paper discusses the potential application of electric propulsion for orbit transfer of a large spacecraft structure from low earth orbit to geosynchronous altitude in a deployed configuration. The electric power was provided by the spacecraft nuclear reactor space power system on a shared basis during transfer operations. Factors considered with respect to system effectiveness included nuclear power source sizing, electric propulsion thruster concept, spacecraft deployment constraints, and orbital operations and safety. It is shown that the favorable total impulse capability inherent in electric propulsion provides a potential economic advantage over chemical propulsion orbit transfer vehicles by reducing the number of Space Shuttle flights in ground-to-orbit transportation requirements.

Silva, T. H.↗

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An advanced geostationary communications platform

A large geostationary communications platform can offer many attractive possibilities for providing lower cost communications. The platform payload concept described in this paper attempts to exploit these possibilities. The use of a combination of spot and wide-area coverage beams accommodates users in both high- and low-density population areas, and provides a good degree of frequency reuse. A standard channel bandwidth, used for most traffic, facilitates interconnectivity among C-, Ku-, and Ka-band users who may all access the platform. Adoption of a 36-MHz channel bandwidth leads to transmission rates that would be easily handled by low-cost terminals providing direct customer premises service. This also lends itself well to a solution using a large number of solid-state power amplifiers operating in all three frequency bands and sharing a common, redundant, conditioned power supply.

Hawkes, Thaddeus A.↗

Optimized allocation method of the VSC-MTDC system for frequency regulation reserves considering the cost

In recent years, the interconnection of asynchronous power grids through the VSC-MTDC system has been proposed and extensively studied in light of the potential benefits of economical bulk power exchanges and frequency regulation reserves sharing. This paper proposed an optimized allocation method for sharing frequency regulation reserves among the interconnected power systems and the corresponding frequency regulation control of the VSC-MTDC system under emergency frequency deviation events. Firstly, the frequency regulation reserve classification is proposed. In the classification, the available frequency response capacity reserves of each interconnection are divided into commercial reserves and regular reserves. While the commercial reserves are procured through long-term contracts, the regular reserves are purchased based on market prices of frequency regulation services. Secondly, based on the proposed frequency regulation reserve classification, a novel frequency regulation control is then introduced for the VSC-MTDC system. This control method could minimize the costs of the disturbed power grid for the needed frequency response supports from the other power grids. Simulation verifications are performed on a modified IEEE 39 bus system and a highly reduced power system model representing the North American grids. The simulation verification indicates that the developed frequency regulation control significantly reduced ancillary service costs of the disturbed power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗