Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system dynamic simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Reshaping the Quantum Arrow of Time

While the microscopic laws of physics are often symmetric under time reversal, most natural processes that we observe are not. The emergent asymmetry between typical and time-reversed processes is referred to as the arrow of time. In quantum physics, an arrow of time emerges when a sequence of measurements is performed on a system. We introduce quantum control tools that can yield dynamics more consistent with time flowing backward than forward. The control tools are based on the explicit construction of a Hamiltonian that can replicate the stochastic trajectories of a monitored quantum system. Such a Hamiltonian can reverse the effect of monitoring and, via a feedback process, generate trajectories consistent with a reversed arrow of time. It can also be used to simulate the backward-in-time dynamics of an open quantum system. Finally, we design a feedback-driven continuous measurement engine powered by the energy pumped into the system by the monitoring process. We show that the engine can operate under experimentally realizable conditions with feedback delay and finite-efficiency measurements.

Entropy production↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a network hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAR regulation technologies as an example to illustrate system setups, communication requirements among different HIL test systems, and connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

digital twin, distribution system, co-simulation, ↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic Modeling of a Fast Spectrum Molten Salt Reactor Integrated Energy System

Liquid-fueled molten salt fast reactors and nuclear-powered integrated energy systems (IESs) have the potential to play a pivotal role in the green energy transition. However, these systems have little to no operating experience. There is therefore increased interest and value in modeling and simulating these systems. The IES dynamic model developed in this work utilizes a lumped-parameter control volume methodology to investigate the behavior of the IES in a variety of accident scenarios. The results provide initial evidence for the potential inherent safety of the advanced reactor because of temperature-dependent reactivity feedback and the efficiency of hydrogen and electricity production at the high temperatures provided by the advanced reactor.

MCFR↗

Grey-Box System Identification of Grid-Forming Inverters

This paper demonstrates the use of grey-box system identification methods for simplifying and understanding the nonlinear power dynamics of grid-forming inverters (GFMs). The power and frequency outputs of complex high-order GFM models are fed into system identification software in order to fit them to a predetermined LTI system and learn system parameters such as (synthetic) inertia and droop constants. The same process is then run for a high-order synchronous generator model, and the outputs are fit to the same set of LTI equations. Simulation of a network of GFM inverters with diverse control architecture is also performed for the same process. The intent is threefold: first, to demonstrate the appropriateness of unified LTI models for describing the power and frequency dynamics of individual resources and connected networks, in order to facilitate analysis of larger heterogeneous networked systems; second, to discover the relationship between internal control parameters of GFMs and their externally observed values; and third, to validate that grey-box data-driven system identification techniques can be a valuable tool to discover the values of important parameters in the absence of explicit vendor models.

analytical models↗

Direct Numerical Simulation of the Flow through a Randomly Packed Pebble Bed

The proposition for molten salt and high-temperature gas-cooled reactors has increased the focus on the dynamics and physics in randomly packed pebble beds. Research is being conducted on the validity of these designs as a possible contestant for the fourth-generation nuclear power systems. A detailed understanding of the coolant flow behavior is required in order to ensure proper cooling of the reactor core during normal and accident conditions. In order to increase the understanding of the flow through these complex geometries and enhance the accuracy of lower-fidelity modeling, high-fidelity approaches such as direct numerical simulation (DNS) can be utilized. Nek5000, a spectral-element computational fluid dynamics (CFD) code, was used to develop DNS fluid flow data. The flow domain consisted of 147 pebbles enclosed by a bounding wall. In the work presented, the Reynolds numbers ranged from 430 to 1050 based on the pebble diameter and inlet velocity. Characteristics of the flow domain such as volume averaged porosity, axial porosity, and radial porosity were studied and compared with correlations available in the literature. Friction factors from the DNS results for all Reynolds numbers were compared with correlations in the literature. The first- and second-order statistics show good agreement with the available experimental data. Turbulence length scales were analyzed in the flow. Reynolds stress anisotropy was characterized by utilizing invariant analysis. Overall, the results of the analysis in this study provide deeper understanding of the flow behavior and the effect of the wall in packed beds.

Yildiz, Mustafa Alper↗

Evaluating diffusion and the thermodynamic factor for binary ionic mixtures

Molecular dynamics (MD) simulations are a powerful tool for the calculation of transport properties in mixtures. Not only are MD simulations capable of treating multicomponent systems, they are also applicable over a wide range of temperatures and densities. In plasma physics, this is particularly important for applications such as inertial confinement fusion. While many studies have focused on the effect of plasma coupling on transport properties, here we focus on the effects of mixing. We compute the thermodynamic factor, a measure of ideal/non-ideal mixing, for three binary ionic mixtures. Here, we consider mixtures of hydrogen and carbon, hydrogen and argon, and argon and carbon, each at 500 randomly generated state points in the warm dense matter and plasma regimes. The calculated thermodynamic factors indicate different mixing behavior across phase space, which can significantly affect the corresponding mutual diffusion coefficients. As MD simulations are still computationally expensive, we apply modern data science tools to predict the thermodynamic factor over a large phase space. Further, we propose a more accurate approximation to the mutual diffusion coefficient than the commonly applied Darken relation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving power grid transient stability and transfer capability using HVDC emergency power controls

In the future, with high levels of renewable energy sources penetration, the transmission corridors will have to be flexible to operate under faster transients and variable power flows. Fast power ramping and overloading capabilities of HVDC system can be utilized to ensure transient stability of the interconnected power grid. In this paper, HVDC auxiliary controllers have been studied that can provide the power grid with additional synchronizing torques through fast DC power changes in response to arising system conditions. The effectiveness of the auxiliary controllers in improving transient stability is demonstrated by performing dynamic simulations on the detailed model of the Western Interconnection system (WECC).

Sundaresh, Lakshmi↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Optimum power analysis of a self-reactive wave energy point absorber with mechanically-driven power take-offs

This paper studies a self-reactive ocean wave energy converter (WEC) where energy is absorbed through the relative motion between a floating buoy on the ocean surface and a submerged body. Two types of direct-drive power take off (PTO) systems are examined. One adopts a ball screw system in inverse driving mode with mechanical motion rectifier (MMR) that converts the oscillating bi-directional input heave motion into unidirectional rotation to drive an electromagnetic generator, and another one uses a ball screw system to directly drive the generator (called non-MMR). Dynamic models for both types of PTOs are established and integrated with the overall WEC system model in both the time and frequency domains. Numerical simulation is used to investigate the dynamic performance of both PTOs. The influences of the PTO inerter, which is from the rotational inertia of the flywheel and generator, and the WEC drag damping coefficient are discussed and explored. The analytical closed-form solution for the optimum condition of the non-MMR system is derived based on the criterion of maximum power absorption, and numerical simulation yields the optimum condition for the MMR system. Overall, the results under regular and irregular waves show that the PTO inerter in the MMR system can improve the power absorption for small wave periods and maintain the same performance for large wave periods. The PTO inerter in the non-MMR system shifts the peak frequency. The WEC drag damping negatively influences the power absorption in both PTO systems, especially at large wave periods.

16 TIDAL AND WAVE POWER↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim (Wave Energy Converter SIMulator) is an open-source code for simulating wave energy converters, which has been actively developed and applied to simulate a wide variety of device archetypes and has become a popular tool since its initial release in 2014. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) within the MATLAB/SIMULINK environment. Figure 1 illustrates a general wave-to-wire model which begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of a single WEC (or array), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modelling the entire wave-to-wire is difficult and encompass multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM) based-frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Table 1 lists additional WEC-Sim functionalities, which are created using prebuilt Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems.

hydrodynamics modeling↗

All-Atom Simulations Uncover Structural and Dynamical Properties of STING Proteins in the Membrane System

Recent studies have shown that the stimulator of interferon gene (STING) protein plays a central role in the immune system by facilitating the production of type I interferons in cells. The STING signaling pathway is also a prominent activator of cancer-killing T cells that initiate a powerful adaptive immune response. Since biomolecular signaling pathways are complicated and not easily identified through traditional experiments, molecular dynamics (MD) has often been used to study structural and dynamical responses of biological pathways. In this work, we carried out MD simulations for full-length chicken and human STING (chSTING and hSTING) proteins. Specifically, we investigated ligand-bound closed (holo) and ligand-unbound open (apo) forms of STING in the membrane system by comparing their conformational and dynamical differences. Our research provides clues for understanding the mechanism of the STING signaling pathway by uncovering detailed insights for the examined systems: the residues from each chain in the binding pocket are strongly correlated to one another in the open STING structure compared with those in the closed STING structure. Ligand-bound closed STING displays ~174° rotation of the ligand-binding domain (LBD) relative to the open STING structure. The dynamical analysis of residue Cys148 located in the linker region of hSTING does not support the earlier hypothesis that Cys148 can form disulfide bonds between adjacent STING dimers. We also demonstrate that using the full-length proteins is critical, since the MD simulations of the LBD portion alone cannot properly describe the global conformational properties of STING.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗