Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

PMU and Communication Infrastructure Restoration for Post-Attack Observability Recovery of Power Grids

This paper is concerned about recovering the observability of cyber-physical power grids after massive cyber attacks, which helps to achieve the cyber-physical resilience of the grids. For recovering the observability of the grid, the measurability of the Phasor Measurement Units (PMUs) and the connectivity of the communication network are needed to be restored. The PMU and communication infrastructure restoration problem is jointly formulated as a Mixed Integer Linear Programming (MILP) problem to minimize the observability loss of the grid over time after a cyber attack while considering the constraint of limited resources. The efficacy of the proposed optimal restoration strategy is verified by comparing with heuristic methods on the IEEE 57-bus system.

cyber security↗

Physics-Informed Gaussian Process Regression for States Estimation and Forecasting in Power Grids

Real-time state estimation and forecasting are critical for the efficient operation of power grids. In this paper, a physics-informed Gaussian process regression (PhI-GPR) method is presented and used for forecasting and estimating the phase angle, angular speed, and wind mechanical power of a three-generator power grid system using sparse measurements. In standard data-driven Gaussian process regression (GPR), parameterized models for the prior statistics are fit by maximizing the marginal likelihood of observed data. In the PhI-GPR method, we propose to compute the prior statistics offline by solving stochastic differential equations (SDEs) governing the power grid dynamics. The short-term forecast of a power grid system dominated by wind generation is complicated by the stochastic nature of the wind and the resulting uncertainty in wind mechanical power. Here, we assume that the power grid dynamics are governed by swing equations, with the wind mechanical power fluctuating randomly in time. We solve these equations for the mean and covariances of the power grid states using the Monte Carlo simulation method. We demonstrate that the proposed PhI-GPR method can accurately forecast and estimate observed and unobserved states. For the considered problem, PhI-GPR has computational advantages over the ensemble Kalman filter (EnKF) method: In PhI-GPR, ensembles are computed offline and independently of the data acquisition process, whereas for EnFK, ensembles are computed online with data acquisition, rendering real-time forecast more challenging. We also demonstrate that the PhI-GPR forecast is more accurate than the EnKF forecast when the random mechanical wind power is non-Markovian. In contrast, the two methods produce similar forecasts for the Markovian mechanical wind power. For observed states, we show that PhI-GPR provides a forecast comparable to the standard data-driven GPR; both forecasts are significantly more accurate than the autoregressive integrated moving average (ARIMA) forecast. We also show that the ARIMA forecast is more sensitive to observation frequency and measurement errors than the PhI-GPR forecast.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods for utilizing maximum power from a solar array

A preliminary study of maximum power utilization methods was performed for an outer planet spacecraft using an ion thruster propulsion system and a solar array as the primary energy source. The problems which arise from operating the array at or near the maximum power point of its 1-V characteristic are discussed. Two closed loop system configurations which use extremum regulators to track the array's maximum power point are presented. Three open loop systems are presented that either: (1) measure the maximum power of each array section and compute the total array power, (2) utilize a reference array to predict the characteristics of the solar array, or (3) utilize impedance measurements to predict the maximum power utilization. The advantages and disadvantages of each system are discussed and recommendations for further development are made.

Decker, D. K.↗

Application of small-signal modeling and measurement techniques to the stability analysis of an integrated switching-mode power system

Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.

Wong, R. C.↗

Lidar remote sensing of tropospheric pollutants and trace gases - Programs of NASA Langley Research Center

NASA Langley Research Center is engaged in a number of in-house and contracted programs to develop, evaluate, and apply lidar techniques to remote measurements of pollutant gases, trace molecules, and aerosols. The differential absorption lidar (DIAL) research programs include the development and evaluation of a UV DIAL system for remote measurements of SO2 and O3 concentrations and aerosol dispersion in urban and power-plant stack plumes, a near-IR DIAL system for vertical measurements of water vapor concentrations, and a high-power tunable IR DIAL system which will measure the concentration of gas species that have absorption features in the 1.4- to 4.4-micron wavelength range. The lidar programs which deal with aerosol measurements include the evaluation of a mobile ruby lidar system for use in plume dispersion model verification and the development of a high-spectral-resolution lidar system for measurement of aerosol extinction and backscattering coefficients. System characteristics and measurement sensitivities are discussed, and comparisons are made between simulations and experimental results.

Browell, E. V.↗

State estimation for spacecraft power systems

A state estimator appropriate for spacecraft power systems is presented. Phasor voltage and current measurements are used to determine the system state. A weighted least squares algorithm with a multireference transmission cable model is used. Bad data are identified and resolved. Once the bad data have been identified, they are removed from the measurement set and the system state can be estimated from the remaining data. An observability analysis is performed on the remaining measurements to determine if the system state can be found from the reduced measurement set. An example of the algorithm for a sample spacecraft power system is presented.

Williamson, Susan H.↗

Pulsed coherent solid-state 1.06-micron and 2.1-micron laser radar systems for remote velocity measurement

A low average power, pulsed, solid-state, 1.06-micron coherent laser radar (CLR) for range and velocity measurements of atmospheric and hard targets has been developed. The system has been operating at a field test site near Boulder, CO since September, 1988. Measurements have been taken on moving targets such as atmospheric aerosol particles, belt sanders, spinning disks, and various stationary targets. The field measurements have shown that this system exhibits excellent velocity measurement performance. A fast-tuning CW Nd:YAG oscillator has also been developed which has a frequency tuning range of greater than 30 GHz (which spans a target radial velocity range of over 16 km/s) and a tuning speed greater than 30 GHz/ms.

Henderson, Sammy W.↗

A Practical On-line Framework for a Modified Energy Detector by Whitening Ambient PMU Data

A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.

Xu, Zikai↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Power system state estimation for a spacecraft power system

An application of the maximum likelihood state estimator to a space-based power system is presented. The state estimator uses current and voltage measurements to generate estimates of node voltages for an electrical power distribution system for the Space Shuttle. Preliminary results on the effect of noisy measurements on estimated parameters are reported. The software used in generating these results is part of an overall package being developed at Louisiana Tech University. Intended applications of this package include the analysis of power systems and real-time parallel processing on the Space Shuttle.

Berry, F. C.↗

Orion Power Transfer: Impacts of a Battery-on-Bus Power System Architecture

The Orion Multi-Purpose Crew Vehicle (MPCV) has the capability to transfer power to a co-manifested payload (CPL) during transit from low-Earth orbit to the lunar vicinity. This paper discusses a time-phased parametric power analysis to determine the Orion power transfer capability limit. Charge and discharge curves were generated for various power transfer conditions and measured against various minimum system voltage limits. The Orion electrical power system (EPS) utilizes an unregulated bus architecture, which has important implications when the system is operating under very high load demand conditions, such as during power transfer. This analysis highlights three important effects of this architecture. First, increasing load demand decreases the maximum state of charge (SOC) the batteries can reach when charging. Second, increasing load demand also decreases the allowable battery depth of discharge. These two together can significantly reduce the effective useable capacity of the batteries. Finally, low battery voltage decreases the power generation of the solar arrays. This can lead to significantly longer recharge times or even push the system out of energy balance. These effects have important implications for mission design and vehicle operations and must be accounted for when conducting sizing and design of an unregulated spacecraft EPS.

Electrical Power System↗

Data-driven Event Identification in the U.S. Power Systems Based on 2D-OLPP and RUSBoosting Trees

Accurate event identification is an essential part of situation awareness ability for power system operators. Therefore, this work proposes an integrated event identification algorithm for power systems. First, to obtain and filter suitable inputs for event identification, an event detection trigger based on the rate of change of frequency (RoCoF) is presented. Then, the wave arrival time difference-based triangulation method considering the anisotropy of wave propagation speed is utilized to estimate the location of the detected event. Next, the two-dimensional orthogonal locality preserving projection (2D-OLPP)-based method, which is suitable for multiple types of measured data, is employed to achieve higher effectiveness in extracting the event features compared with traditional one-dimensional projection and principle component analysis (PCA). Finally, the random undersampling boosted (RUSBoosted) trees-based classifier, which can mitigate the data sample imbalance issue, is utilized to identify the type of the detected event. Furthermore, the proposed approach is demonstrated using the actual measurement data of U.S. power systems from FNET/GridEye. Comparison results show that the proposed event identification algorithm can achieve better performance than existing approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proactive Frequency Stability Scheme: A Distributed Framework Based on Particle Filters and Synchrophasors

The reactive nature of traditional under-frequency load shedding schemes can lead to delayed response and unnecessary loss of load. This work presents a proactive framework for power system frequency stability. Bayesian filters and synchrophasors are leveraged to produce predictions after disturbances are detected. By being able to estimate the future state of frequency corrective actions can be taken before the system reaches a critical condition. This proactive approach makes it possible to optimize the response to a disturbance, which results in a decrease in the amount of compensation utilized. The framework is tested via Matlab simulations based on Kundur’s Two-Area System, and the IEEE 14-Bus System. Performance metrics are provided and evaluated against other contemporary solutions found in literature. During testing this framework outperformed other solutions by drastically reducing the amount of load dropped during compensation.

42 ENGINEERING↗

HERO WEC V1.0 2024 - WEC-Sim Detailed Simulation Runs and Summary Data

This dataset includes results from simulations of NREL's hydraulic and electric reverse osmosis wave energy converter (HEREO WEC). Simulation runs include 135 wave cases that were based on the updated WEC-Sim model, which is linked below. The data represented in this repository is based on an updated WEC-Sim model using laboratory data to tune and refine the original WEC-Sim model for the V1.0 HERO WEC. The 135 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 3.75m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 100 second ramp time, a total simulation time of 3,100 seconds, and a simulation time-step of 0.005s. A reference table has been included to map each multi condition run (MCR) case with each wave condition. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the simulation runs, in the same increments. The following matrices are included: - Power Abs: The average absorbed power from the WEC (calculated from anchor reaction force and heave velocity) - Power Hyd: The average hydraulic power output at pump (calculated from pump output flow and pressure) - Power - Hyd ROi: The average hydraulic power measured at the RO system inlet (calculated from RO system pressure and flow (pre-accumulator)) - Flow - Pump out: The average flowrate measured at the pump outlet - Flow - Perm: The average permeate (clean water) production - Flow - RO (pre): The average flowrate measured at the inlet of the RO system before the accumulators - Flow - RO (post): The average flowrate measured after the accumulator bank in the RO system - Pressure - RO: The average pressure measured at the inlet of the RO system This data set has been developed by the National Renewable Energy Laboratory, operated by the Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

The Aquarius Scatterometer: An Active System for Measuring Surface Roughness for Sea-Surface Brightness Temperature Correction

The Aquarius scatterometer is a total-power L-band radar system for estimating ocean surface roughness. Its measurements will enable the removal of wind effects from the Aquarius radiometer ocean-surface brightness temperature measurements being used to retrieve ocean salinity. The Aquarius scatterometer is a relatively simple, low-spatial resolution power-detecting radar, without ranging capability. But to meet its science requirement, it must be very stable, with repeatability on the order of 0.1 dB over several days, and calibrated accuracy to this level over several months. Data from this instrument over land as well as ocean areas will be available for a variety of geophysical applications.

scatterometers↗