Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

165 records · Page 10

Initial Characterization of the NREL Large-Amplitude Motion Platform

The Large Amplitude Motion Platform (LAMP) at NREL represents a significant advancement in the controlled testing of Wave Energy Converters (WECs) under laboratory conditions. Originally designed by E2M as a six-degree-of-freedom (DOF) Stewart platform for flight simulation, LAMP has been adapted by NREL to facilitate the mounting and evaluation of WECs. This adaptation enables dry testing of WECs using motion profiles similar to the ocean, facilitating the iterative design, testing, and validation of WEC performance prior to ocean deployments. This report presents the initial work completed to characterize LAMP, with particular emphasis on its stability and operational capabilities across various single and multi-degree-of-freedom (DOF) motion profiles. The report includes planned comparisons at three distinct mass payloads, aimed at assessing the platform's positional accuracy, frequency response, and endurance over extended runtime periods. These experimental tests are critical for establishing the platform's limitations and ensuring that the data generated during WEC validation is both accurate and reproducible. The outcomes of this study not only contribute to a deeper understanding of LAMP's capabilities but also lay the groundwork for future advancements in WEC testing methodologies. By providing robust and reliable performance data within a controlled laboratory setting, the findings are expected to significantly enhance the development and commercialization of marine energy technologies. This report presents the initial findings of the LAMP Characterization work and proposed steps to further understand and characterize LAMP. Data collected during this work can be found on MHKDR at: https://mhkdr.openei.org/submissions/602 Note that this report shares the measured/found instantaneous maximum operating range of LAMP. For most applications the maximum operating range cannot be used for system health and longevity. The operating range and capabilities of LAMP will be evaluated on a case-by-case basis, single-DOF position, velocity, and acceleration values presented in Table 4a-c, and Table 5 should be taken as instantaneous absolute maximum values. Future use of LAMP will likely be limited to smaller values.

16 TIDAL AND WAVE POWER↗

Diffusion of acceptor dopants in monoclinic 𝛽−Ga 2⁢ O 3

𝛽−Ga 2 ⁢O 3 is a promising material for next-generation power electronics because of its ultrawide band gap and high critical breakdown voltage. However, realizing its full potential requires precise control over dopant incorporation and stability. In this work, we use first-principles calculations to systematically assess the diffusion behavior of eight potential deep-level substitutional acceptors (Au, Ca, Co, Cu, Fe, Mg, Mn, and Ni) in 𝛽−Ga 2 ⁢O 3 . We consider two key diffusion mechanisms: (i) interstitial diffusion under nonequilibrium conditions relevant to ion implantation, and (ii) trap-limited diffusion (TLD) under near-equilibrium thermal annealing conditions. Our results reveal a strong diffusion anisotropy along the 𝑏 and 𝑐 axes, with dopant behavior governed by competition between diffusion and incorporation (or dissociation) activation energies. Under interstitial diffusion, Ca$^{2+}_{i}$ and Mg$^{2+}_{i}$ show the most favorable combination of low migration and incorporation barriers, making them promising candidates for efficient doping along the 𝑏 and 𝑐 axes, respectively. In contrast, Au$^{+}_{i}$ diffuses readily, but exhibits an incorporation barrier that exceeds 5 eV, rendering it ineffective as a dopant. From a thermal stability perspective, Co$^{2+}_{i}$ shows poor activation but high diffusion barriers, which may suppress undesirable migration at elevated temperatures. Under trap-limited diffusion, the dissociation of dopant-host complexes controls mobility. Mg$^{2+}_{i}$ again emerges as a leading candidate, exhibiting the lowest dissociation barriers along both axes, whereas Co$^{2+}_{i}$ and Fe$^{2+}_{i}$ display the highest barriers, suggesting improved dopant retention under thermal stress. In conclusion, our findings guide dopant selection by balancing activation and thermal stability, essential for robust semi-insulating substrates.

Defects↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗