Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Modeling injection-induced fault slip using long short-term memory networks

Stress changes due to changes in fluid pressure and temperature in a faulted formation may lead to the opening/shearing of the fault. This can be due to subsurface (geo)engineering activities such as fluid injections and geologic disposal of nuclear waste. Such activities are expected to rise in the future making it necessary to assess their short- and long-term safety. Here, a new machine learning (ML) approach to model pore pressure and fault displacements in response to high-pressure fluid injection cycles is developed. The focus is on fault behavior near the injection borehole. To capture the temporal dependencies in the data, long short-term memory (LSTM) networks are utilized. To prevent error accumulation within the forecast window, four critical measures to train a robust LSTM model for predicting fault response are highlighted: (i) setting an appropriate value of LSTM lag, (ii) calibrating the LSTM cell dimension, (iii) learning rate reduction during weight optimization, and (iv) not adopting an independent injection cycle as a validation set. Several numerical experiments were conducted, which demonstrated that the ML model can capture peaks in pressure and associated fault displacement that accompany an increase in fluid injection. The model also captured the decay in pressure and displacement during the injection shut-in period. Further, the ability of an ML model to highlight key changes in fault hydromechanical activation processes was investigated, which shows that ML can be used to monitor risk of fault activation and leakage during high pressure fluid injections.

58 GEOSCIENCES↗

Development and Integration of Predictive Models for Manufacturing and Structural Performance of Carbon Fiber Composites in Automotive Applications (Final Report)

The goal of this project is to develop integrated, state-of-the-art, computational modeling tools based on an integrated computational materials engineering (ICME) methodology that are critically needed to enable structural carbon fiber (CF) applications in automobiles. These tools are designed to predict the manufacturing and structural performance of CF composites, including stochastic effects. During the first phase of the project, the manufacturing and structural performance tools, including a stochastic driver, were developed, calibrated, and validated against coupon and component level test results. For this project, from the manufacturing side, the development efforts were focused on high-pressure resin transfer molding (HP-RTM), a potentially game-changing manufacturing technology that is capable of reaching the 3-5-minute cycle time that is necessary for volume manufacturing of composites. On the structural performance side, the crashworthiness of CF structures was studied. Accordingly, computational tools were developed and validated. The resulting differences between the numerical predictions and the experimental results in the first phase of the project were required to be less than 15%. During the second phase of the project, the manufacturing and performance tools were integrated by mapping the manufacturing outcomes (e.g., fiber angles, residual stresses, degree of cure, and defects) into the structural models. Also, using the tools developed in this project, an automotive assembly currently manufactured in steel (2016 GM Malibu) was redesigned to be manufactured using advanced CF composites with the objective of comparing the performance of the CF assembly with the developed ICME model predictions. The weight, performance and cost of the CF assembly were compared with the baseline steel assembly as well. The CF underbody design was shown to be 30% lighter than the corresponding steel design. The CF underbody assembly withstood the side pole impact with less than half the intrusion for the steel assembly. Excellent correlations within 10% for both peak impact load and intrusion were observed between the numerical predictions and experimental results. Based on the cost models developed in the project, the cost increase per Kg saved was determined to be $22. The project team has prepared a total of 28 publications in various journals and conferences and broadly communicated the project results for the benefit of the composite industry. The project team has also prepared a total of 10 patent applications that were submitted to the US Patent and Trademark office.

36 MATERIALS SCIENCE↗

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Portable and Cost-Effective Device for Reliable Detection of Counterfeit and Non-compliant Refrigerants in Diverse Applications

Counterfeit refrigerants pose significant challenges to safety, system reliability, and operational effectiveness due to their harmful contaminants or incompatible chemical compositions. Utilizing these noncompliant products can lead to reduced efficiency, equipment failures, and expensive repairs. Additionally, heightened demand for alternative refrigerants during the industry's transition has created supply gaps, enabling counterfeit products to proliferate. Accurate detection and analysis tools are therefore essential to verify refrigerant authenticity and ensure system integrity in diverse applications. This paper presents the development of a portable device designed for reliable identification and detailed analysis of refrigerant composition. By integrating precision gas sampling, controlled pressure regulation, and automated sensor technology, the device not only detects deviations from standard refrigerant properties but also provides a comprehensive composition breakdown. Pre-calibrated sensors measure the refrigerant gas to identify specific concentrations and contaminants, with an intuitive LED-based indicator system ensuring quick interpretation of results. The user-friendly interface enables operators to select refrigerant types for targeted testing, further enhancing accuracy and usability for field technicians. Comprehensive testing was conducted on mildly flammable A2L refrigerants, showcasing the device’s robustness and adaptability in analyzing composition and detecting discrepancies. The device demonstrated consistent accuracy across a range of refrigerant samples, affirming its reliability in diverse operational environments. Its design minimizes contamination risks during sampling and provides detailed composition results within 90 seconds, ensuring efficient and precise analysis. With a projected price point under $150, the proposed solution delivers affordability alongside its lightweight portability and straightforward operation. Unlike complex and costly alternatives, such as gas chromatography systems, this device provides an accessible option for technicians, customs personnel, and industry operators in need of quick and effective refrigerant verification. Compatible with both current formulations and emerging refrigerant technologies, the device addresses critical counterfeit detection needs across a range of applications. By delivering accurate composition analysis and counterfeit identification, this innovation enhances system performance, safety, and operational reliability in crucial industries.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Fracture Description of the HFTS-2 Slant Core, Delaware Basin, West Texas

Previous work in the Midland Basin Hydraulic Fracture Test Site project (HFTS1) has shown the value of core recovered from a stimulated volume in providing information on the geometry and extent of hydraulic fractures. This project (HFTS2) is in the Wolfcamp Formation of the Delaware Basin. A slant core through the stimulated volume was acquired above and below a stimulated well and the results of the fracture description are presented here. Here, nine, 3-inch-diameter whole cores from the slant well were examined for fractures prior to slabbing, together with a CT scan of the core. We used criteria developed during the HFTS1 project to identify hydraulic, natural, drilling-induced and core-handling fractures. Material collected from a few fracture faces was cleaned, sieved, and examined under a microscope to look for proppant. A total of 1261 fractures, including 500 hydraulic fractures, were described in 948 feet of core. Hydraulic fractures are not evenly distributed through the cores; they tend to occur in clusters. Many are remarkably planar, smooth, and featureless, while others have twist hackles, steps, plumose, and kinks. Natural, subvertical fractures, mostly less than 1 mm in width, sealed with blocky calcite, are oriented NE-SW (Set 1) and WNW-ESE (Set 2). Two Set 1 fractures have drusy cement on parted faces and were possibly open prior to drilling. A few subvertical sealed fractures with different orientations are also present. Bed-parallel natural fractures, most having fibrous cement (beef), and some showing top-to-north bed-parallel shear are present. Faults with normal/oblique movement were found in one part of the core. Drilling induced and core-handling breaks were identified in all cores, and were also noted to have reactivated some natural fractures. The results from this work will allow hydraulic fracture distribution relative to the stimulated well to be assessed. The number of fractures is generally greater than the number of perforations, but these can be compared for different stages and perforation clusters. Surface features provide information about the direction of hydraulic fracture propagation and about segmentation and bifurcation that might increase the number of fracture strands. Reactivation of natural fractures, including bedding-parallel fractures, occurs although the mechanism of parting is mostly unknown. The wider HFTS2 project will make use of this fracture description to improve hydraulic fracture modeling (geomechanics and engineering), to help explain pressure depletion and fiber optics observations (reservoir depletion and frac geometry), to help verify indirect fracture diagnostic techniques such as microseismic monitoring (geophysics), and to help calibrate horizontal well image logs.

58 GEOSCIENCES↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Advanced Intra-Cycle Detection of Pre-Ignition Events through Phase-Space Transforms of Cylinder Pressure Data

The widespread adoption of boosted, downsized SI engines has brought pre-ignition phenomena into greater focus, as the knock events resulting from pre-ignitions can cause significant hardware damage. Much attention has been given to understanding the causes of pre-ignition and identify lubricant or fuel properties and engine design and calibration considerations that impact its frequency. This helps to shift the pre-ignition limit to higher specific loads and allow further downsizing but does not fundamentally eliminate the problem. Real-time detection and mitigation of pre-ignition would thus be desirable to allow safe engine operation in pre-ignition-prone conditions. This study focuses on advancing the time of detection of pre-ignition in an engine cycle where it occurs. Furthermore, phase space transforms through time-delay embedding of cylinder pressure and principal component analysis were applied to same-cycle detection of pre-ignition and shown to enable detection on the order of a crank degree earlier than deviation in cylinder pressure can be identified through direct statistical observation of the pressure data. Additionally, it appears that the deviation of the trajectory in phase space may offer the opportunity to extend this method to further extend the detection window and allow more time for mitigation actions to occur.

42 ENGINEERING↗

Quantitatively Monitoring Bubble-Flow at a Seep Site Offshore Oregon: Field Trials and Methodological Advances for Parallel Optical and Hydroacoustical Measurements

Two lander-based devices, the Bubble-Box and GasQuant-II, were used to investigate the spatial and temporal variability and total gas flow rates of a seep area offshore Oregon, United States. The Bubble-Box is a stereo camera–equipped lander that records bubbles inside a rising corridor with 80 Hz, allowing for automated image analyses of bubble size distributions and rising speeds. GasQuant is a hydroacoustic lander using a horizontally oriented multibeam swath to record the backscatter intensity of bubble streams passing the swath plain. The experimental set up at the Astoria Canyon site at a water depth of about 500 m aimed at calibrating the hydroacoustic GasQuant data with the visual Bubble-Box data for a spatial and temporal flow rate quantification of the site. For about 90 h in total, both systems were deployed simultaneously and pressure and temperature data were recorded using a CTD as well. Detailed image analyses show a Gaussian-like bubble size distribution of bubbles with a radius of 0.6–6 mm (mean 2.5 mm, std. dev. 0.25 mm); this is very similar to other measurements reported in the literature. Rising speeds ranged from 15 to 37 cm/s between 1- and 5-mm bubble sizes and are thus, in parts, slightly faster than reported elsewhere. Bubble sizes and calculated flow rates are rather constant over time at the two monitored bubble streams. Flow rates of these individual bubble streams are in the range of 544–1,278 mm 3 /s. One Bubble-Box data set was used to calibrate the acoustic backscatter response of the GasQuant data, enabling us to calculate a flow rate of the ensonified seep area (~1,700 m 2 ) that ranged from 4.98 to 8.33 L/min (5.38 × 10 6 to 9.01 × 10 6 CH 4 mol/year). Such flow rates are common for seep areas of similar size, and as such, this location is classified as a normally active seep area. For deriving these acoustically based flow rates, the detailed data pre-processing considered echogram gridding methods of the swath data and bubble responses at the respective water depth. The described method uses the inverse gas flow quantification approach and gives an in-depth example of the benefits of using acoustic and optical methods in tandem.

54 ENVIRONMENTAL SCIENCES↗

A Review and Outlook on Experimental Advances and Innovations in Geological CO 2 Storage: Insights from Depleted Gas Reservoirs and Saline Aquifers

Geological storage of carbon dioxide (CO 2 ) in depleted gas reservoirs and deep saline aquifers is a key part of global decarbonization efforts. As carbon capture and storage advances toward commercial-scale deployment, the credibility and scalability of laboratory experiments are increasingly vital for guiding safe and effective field implementation. This review offers a comprehensive, cross-scale evaluation of experimental methodologies, including core flooding, high-pressure, high-temperature systems, microfluidic visualization, and emerging systems such as multilayer commingled/compartmentalized core flooding, 3D-printed micromodels, and AI-powered digital twins. These innovations are demonstrated to enhance representativeness, reproducibility, and real-time insight, thereby addressing the limitations of conventional workflows. A critical analysis of methodological gaps, such as inconsistent pressure–temperature conditions, oversimplified brine chemistry, and a lack of standardization, reveals experimental sources of scale translation errors and performance uncertainty. By comparing the unique challenges of depleted gas reservoirs (such as low water saturation and legacy well leakage) to those of saline aquifers (including pressure buildup and caprock integrity), this review identifies formation-specific priorities for experimental design. Novel contributions include a synthesis of best practices, integration strategies for model calibration, and recommendations for standardizing core handling, saturation procedures, and reporting protocols. Furthermore, this work serves as a guide for developing robust, field-relevant experimental strategies that can increase the deployment and regulatory acceptance of CO 2 storage technologies at scale.

58 GEOSCIENCES↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD-Enhanced Calibration of a Multihole Probe for Small Uncrewed Aircraft Systems

A robust calibration method with a 9-hole probe (9HP) for inertial wind vector measurements from a small uncrewed aircraft system (sUAS) is presented. Calibration accuracy is improved by using computational fluid dynamics (CFD) to estimate corrections, such as those for test section blockage, that are generally applied in wind tunnel testing. A method for estimating experimental bias is presented to account for flow variations over the pressure taps as the 9HP is repositioned in the test section. Installation effects from flow over the airframe and upwash produced by the wings are estimated from CFD simulations of the entire airframe at the expected cruise speed. An initial CFD analysis has demonstrated a quantifiable linear relationship between the measured and actual angle of attack as measured from the relative wind frame. In conclusion, the objective of these additional steps is to increase the accuracy of 9HP calibration.

54 ENVIRONMENTAL SCIENCES↗

Reduced scale stripline platform to extend accessible pressures on the Z machine: Shockless compression of platinum to 650 GPa

Reaching astrophysically relevant high energy density (HED) material states in the laboratory is an ongoing effort at multiple experimental facilities. We have developed a new dynamic compression platform for the Z Pulsed Power Facility that allows for sample sizes 100s of [Formula: see text]m in thickness that accommodate multiple grains in order to fully capture bulk properties, such as material strength. A pair of experiments compressed platinum (Pt) to HED conditions and conventional inverse Lagrangian analysis as well as a recent Bayesian calibration technique were used to determine the principal isentrope to 650 GPa with density uncertainties of <2%. These low uncertainties are calculated for single sample experiments, presenting the possibility of even smaller experimental uncertainties with multiple samples the platform allows. Our new platform extends the accessible Pt ramp pressures achievable on the Z machine to over 80% of the pressure recently achieved using the National Ignition Facility planar Hohlraum platform. This new capability, the next generation evolution of the stripline platform, was made possible by advancements in both our understanding of the Z pulsed power driver and our overall magnetohydrodynamic modeling capabilities.

Porwitzky, Andrew↗

Comprehensive Studies on Hot Compaction and Vibration-Assisted Compaction Tests of Aluminum Powder

Abstract Aluminum powder compaction was studied using both test and simulation. Cold compaction, hot compaction, and vibration-assisted (cold) compaction tests were conducted to achieve different density ratios. First, the hot compaction test (at 300 °C, compression pressure 140 MPa) improved about 6% compared with cold compaction under the same compression pressure. Second, although the relative density ratio does not obviously improve at a vibration-assisted (cold) compaction, the strength of the specimens made under vibration loading is much better than those of cold compaction. Additionally, finite element models with well-calibrated Drucker–Prager Cap (DPC) material constitutive model were built in abaqus/standard to simulate the powder compaction process. The results of the finite element model have very good correlations with test results up to the tested range, and this finite element model further predicts the loading conditions needed to achieve the higher density ratios. Two exponential equations of the predicted density ratio were obtained by combining the test data and the simulation results. A new analytical solution was developed to predict the axial pressure versus the density ratio for the powder compaction according to DPC material model. The results between the analytical solution and the simulation model have a very good match.

Engineering↗

An experimental investigation on the CO 2 storage capacity of the composite confining system

Assuring secure containment of stored CO 2 is of paramount importance—for climate change mitigation, for permitting, and for reassuring the public. Regional seals, such as those sealing petroleum accumulations, have proven to be effective for securing CO 2 . However, the goal of permanent sequestration can also be satisfied with “composite confining systems” consisting of multiple, possibly discontinuous flow barriers that, in aggregate, create a system with very high permeability anisotropy and effectively retard the vertical migration of CO 2 . This study focuses on investigating the barrier characteristics necessary for effective containment of CO 2 , using both physical flow experiments and modified invasion percolation simulations. The simulations are calibrated to the physical experiments and are used to further extend the analysis. Results show that for a composite confining system, a) even barriers with low capillary entry pressure contrast to the underlying flow unit can divert rising CO 2 ; b) curved or anticlinal barrier topography can enhance CO 2 trapping; c) fining-upward gradations make little difference to barrier effectiveness or CO 2 retention; d) longer barriers retain more CO 2 regardless of barrier topography. Finally, field-scale simulations have demonstrated the importance of barrier length for increasing CO 2 storage capacity. Furthermore, the results presented can be used to inform the development of new screening criteria for characterization and effectiveness of composite confining systems.

58 GEOSCIENCES↗

The design of a photoionization front experiment using the Z-Machine as a driving source and estimated measurements

Radiation-driven heat fronts are present in the early universe during reionization, the circumstellar medium of supernovae, and in high-energy-density physics experiments. Dedicated experiments to observe and diagnose the behavior of these types of heat fronts can improve our understanding of these phenomena. A simulation study of photoionization fronts using the HELIOS-CR radiation hydrodynamics code provides an experimental design for the Z-Machine at Sandia National Laboratory using a measurement-calibrated input radiation flux to drive the photoionization front. The simulations use detailed atomic physics and non-diffusive radiation transport in 1D to determine an optimal gas pressure of 0.75 atm for an experiment in N gas as well as the effects of increasing the thickness of the window that seals the gas cell. Post-processing of these simulations demonstrates that ratios of atomic rate coefficients place the heat front in a physics regime where photoionization dominates the energy deposition. Here, to see the sensitivity of the simulations to changes in the model and spatial grid, this analysis performed resolution, atomic model detail, and radiation transport angular grid studies showing less than 10% deviation from the nominal model for increased complexity, when possible. An effort to emulate 3D geometric effects on the radiation flux using an artificial attenuation scheme has shown that, even for conservative estimates of the flux, simulations still produce a photoionization front. Estimations of a streaked, visible spectroscopy measurement using SPECT3D showed that line emission measurements are present early in time and that later in time thermal emission should become dominant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

Small Punch Testing of Molybdenum-99 Targets

Northstar Medical Radioisotopes is developing an accelerator-based method to produce 99 Mo, which is a parent isotope of the commonly used 99m Tc medical isotope. The Mo targets being designed for the accelerator will be produced from enriched 100 Mo, also known as aMo . Pressed and sintered powder feedstock is used to fabricate aMo targets, producing 29 mm disk-shaped targets. The targets are subjected to 1–6 days in line of an electron beam with subsequent dissolution of the disk to retain the 99 Mo, which decays to 99m Tc at radio-pharmacies. The press and sinter method is advantageous because the inherent porosity produced by this method enables increased surface area and therefore increased flow of dissolution media, decreasing the dissolution time and reducing the need for a highly acidic media. Although porosity aids in dissolution, it reduces the mechanical strength and ductility. Targets require good mechanical integrity when subjected to the conditions in the accelerator. Therefore, Northstar is seeking methods to rapidly test disk samples after fabrication to assure mechanical performance metrics are achieved. This report details the design and testing of a small punch test (SPT) that accommodates the 29 mm disk. Initial data were used to relate the SPT data to tensile properties, such as the yield strength (YS), ultimate tensile strength (UTS), and total elongation to failure. Although the SPT has been established as a somewhat reliable method for testing metallic materials, few studies have applied the SPT to refractory materials such as Mo. Based on tensile testing performed at Oak Ridge National Laboratory on different Mo samples, correlation between the Mo tensile and SPT properties could be performed, establishing a standard calibration that could be applied to other Mo samples. To test the efficacy of the SPT with Mo, multiple different disk batches were fabricated under different conditions (e.g., pressure, lubricant) with commercially available pure Mo powder. Generally, only a UTS could be well defined because the press and sinter disks failed under brittle fracture, making it difficult to determine the YS and elongation. Compared with disks fabricated with aMo powder, the aMo samples underperformed their pure nat Mo counterparts. This report summarizes the current status of the SPT, but further evaluation is needed before it can be applied as a reliable quality assurance tool.

62 RADIOLOGY AND NUCLEAR MEDICINE↗