Tissue Engineered Skeletal Myofibers can Directly "Sense" Gravitational Force Changes

Long-term manned space flight requires a better understanding of skeletal muscle atrophy resulting from microgravity. Atrophy most likely results from changes at both the systemic level (e.g. decreased circulating growth hormone, increased circulating glucocorticoids) and locally (e.g. decreased myofiber resting tension). Differentiated skeletal myofibers in tissue culture have provided a model system over the last decade for gaining a better understanding of the interactions of exogenous growth factors, endogenous growth factors, and muscle fiber tension in regulating protein turnover rates and muscle cell growth. Tissue engineering these cells into three dimensional bioartificial muscle (BAM) constructs has allowed us to extend their use to Space flight studies for the potential future development of countermeasures. Embryonic avian muscle cells were isolated and BAMs tissue engineered as described previously. The myoblasts proliferate and fuse into aligned postmitotic myofibers after ten to fourteen days in vitro. A cylindrical muscle-like structure containing several thousand myofibers is formed which is approximately 30 mm in length, 2-3 mm in diameter, and attached at each end. For the Space Shuttle experiments, the BAMs were transferred to 55 mL bioreactor cartridges (6 BAMs/cartridge). At Kennedy Space Center, the cartridges were mounted in two Space Tissue Loss (STL) Modules (three to four cartridges per Module) and either maintained as ground controls or loaded in a Mid-Deck locker of the Space Shuttle. The BAM cartridges were continuously perfused during the experiment at 1.5 mL/ min with tissue culture medium. Eighteen BAMs were flown for nine days on Mission STS66 while eighteen BAMs served as ground controls. The complete experiment was repeated on Mission STS77 with twenty four BAMs in each group. BAMs could be maintained in a healthy state for at least 30 days in the perfusion bioreactor cartridges. The BAM muscle fibers directly detected both the loss of gravity and the reloading effects of 1 x g. While total cellular metabolism and total protein degradation rates were not altered during 9 to 10 days in Space, protein synthesis rates were significantly reduced and resulted in significant myofiber atrophy compared to ground controls. One g reloading of the flight muscle cells post-flight significantly increased protein synthesis rates and the synthesis rates of myosin heavy chain, fibronectin, and collagen. Tissue cultured muscle cells can directly "sense" changes in gravity and provide a valid model to begin the study of countermeasures. Based on our ground based experiments, and the experiments of others, growth hormone and/or insulin-like growth factors are attractive protein therapeutics which may assisting attenuating skeletal muscle wasting in space. Our laboratory is developing a new cell-based delivery system for this and other potential therapeutic factors for attenuating muscle and bone wasting.

Vandenburgh, Herman H.↗

Monocular Ranging for Small Unmanned Aerial Systems in the Far-Field

Recent proliferation of small Unmanned Aerial Systems (sUAS) applications requires onboard collision avoidance systems to mitigate the risk of collision with non-cooperative aircraft and manned aircraft, which may not see sUAS in time to perform an avoidance maneuver. An attractive avenue for onboard collision avoidance is the utilization of machine vision cameras due to their low size, weight and power (SWaP) requirements. In this paper, we characterize the range performance of a machine vision system developed in-house and mounted onto an sUAS. The technique was designed to estimate the performance of a sense-and-avoid system to ensure that the sensing components meet the well-clear requirements for the chosen platform and avoidance strategy. Experimental flight-test data was acquired from test-flights flown along multiple collision geometries for two intruders: a general Aviation (GA) aircraft and a fixed-wing sUAS. The ownship and both intruders were instrumented with inertial navigation systems (INS) recording position and attitude information. The range at first detection, 𝑹𝟎, was extracted from in-flight imagery of head-on collision course geometry synchronized with INS data from both aircraft and ground-truth values extracted from the raw imagery. This initial detection distance, 𝑹𝟎, scales with atmospheric attenuation. Therefore, under clear sky conditions, the derived 𝑹𝟎 value represents the upper bound on the detection range achievable by the test configuration of the detector. Results indicate that the maximum initial detection distance for a 4k resolution action camera fitted with a 41º Field of View (FOV) lens is 2.763 ± 0.037 km for a GA aircraft and 0.881 ± 0.061 km for a fixed-wing sUAS, respectively. The in results this study suggest that a vision-based detect and track system may be analyzed using the sensor characterization and contextualized within aircraft well-clear volumes.

Chester V. Dolph↗

Characterization of Volume F Trash from the Three FY11 STS Missions: Trash Weights and Categorization and Microbial Characterization

The project reported here provides microbial characterization support to the Waste Management Systems (WMS) element of NASA's Life Support and Habitation Systems (LSHS) program. Conventional microbiological methods were used to detect and enumerate microorganisms in STS Volume F Compartment trash for three shuttle missions: STS 133, 134, and 135. This trash was usually made available within 2 days of landing at KSC. The Volume F bag was weighed, opened and the contents were cataloged and placed into categories: personal hygiene items - inclUding EVA maximum absorbent garments (MAGs) and Elbow packs (daily toilet wipes, etc), drink containers, food waste (and containers), office waste (paper), and packaging materials - plastic film and duct tape. The average wet trash generation rate for the three STS missions was 0.362 % 0.157 kgwet crew 1 d-1 . This was considerably lower and more variable than the average rate for 4 STS missions reported for FY10. Trash subtotals by category: personal hygiene wastes, 56%; drink items, 11 %; food wastes, 18%; office waste, 3%; and plastic film, 12%. These wastes have an abundance of easily biodegraded compounds that can support the growth of microorganisms. Microbial characterization of trash showed that large numbers of bacteria and fungi have taken advantage of this readily available nutrient source to proliferate. Exterior and interior surfaces of plastic film bags containing trash were sampled and counts of cultivatable microbes were generally low and mostly occurred on trash bundles within the exterior trash bags. Personal hygiene wastes, drink containers, and food wastes and packaging all contained high levels of, mostly, aerobic heterotrophic bacteria and lower levels of yeasts and molds. Isolates from plate count media were obtained and identified .and were mostly aerobic heterotrophs with some facultative anaerobes. These are usually considered common environmental isolates on Earth. However, several pathogens were also isolated: Staphylococcus aureus and Escherichia coli.

Strayer, Richard F.↗

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Explosive Byproduct Gas Transport Through Sorptive Geomedia

Current underground nuclear explosion (UNE) detection strategies rely heavily on atmospheric noble gas sampling of radioxenon. However, discriminating nuclear weapons testing programs from civilian sources is difficult due to highly variable atmospheric radioxenon backgrounds and processes affecting subsurface transport of parent radionuclides. Here, we aim to study the transport of gases produced by subsurface explosions as novel stable signatures for underground nuclear explosion (UNE) monitoring. These gases may be produced in large quantities with distinct molecular ratios, which will be impacted by subsurface transport processes. To demonstrate how ratios of gases produced by explosions can change during transport in geomaterials, we conducted laboratory benchtop experiments on the transport of carbon dioxide (CO 2 ) and hydrogen (H 2 ) gases through variably saturated zeolitic tuff, which is abundant at the historic US testing site. We observed that zeolitic tuff sorbs substantial quantities of CO 2 while allowing H 2 to transport more freely, leading to changes in the molecular ratios of the two gases along the transport pathway. Gas uptake in the dry zeolitic tuff core was 72.3% for CO 2 , compared with 53.4% for xenon and 7.6% for H 2 . The presence of 20% water saturation disrupted the CO 2 sorption process, though to a lesser extent than observed for noble gases, with a 36.7% drop in xenon sorption compared with a 21.9% drop for CO 2 . These results represent the first observations of zeolite sorption altering explosive gas ratios during transport through geomedia relevant to nuclear proliferation monitoring.

54 ENVIRONMENTAL SCIENCES↗

Forbidden scalar dark matter and dark Higgses

As experimental searches for WIMP dark matter continue to yield null results, models beyond the WIMP paradigm have proliferated in order to elude ever improving observational constraints, among them that of sub-GeV dark matter mediated by a massive vector portal (a dark photon) associated with a new dark U(1) gauge symmetry. It has been previously noted that for a significant range of the parameter space of this class of models, the annihilation of dark matter particles into a pair of dark photons can dominate the freeze-out process even when this process is kinematically forbidden for dark matter at rest — this is known as the “forbidden dark matter” (FDM) regime. Prior studies of this regime, however, assume that any “dark Higgs” associated with breaking the dark U(1) and imparting mass to the dark photon is decoupled from the dark matter and as such plays no role in the freeze-out process. In this paper, we explore the effects of a dark Higgs on sub-GeV dark matter phenomenology in this FDM regime by considering the simplest possible construction in which there exist non-trivial dark matter-dark Higgs couplings: a model with a single complex scalar DM candidate coupled directly to the dark Higgs field. We find that for a wide range of parameter space, the dark Higgs can alter the resulting relic abundance by many orders of magnitude, and that this effect can remain significant even for a small dark matter-dark Higgs coupling constant. Considering measurements from direct detection and measurements of the CMB, we further find that points in this model’s parameter space which recreate the appropriate dark matter relic abundance suffer only mild constraints from other sources at present, but may become accessible in near-future direct detection experiments.

79 ASTRONOMY AND ASTROPHYSICS↗