Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton exchange membrane electrolyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Anion-Exchange-Membrane Electrolysis with Alkali-Free Water Feed

Hydrogen is a green and sustainable energy vector that can facilitate the large-scale integration of intermittent renewable energy, renewable fuels for heavy transport, and deep decarbonization of hard-to-abate industries. Anion-exchange-membrane water electrolyzers (AEM-WEs) have several achieved or expected competitive advantages over other electrolysis technologies, including the use of precious metal-free electrocatalysts at both electrodes, fluorine-free hydrocarbon-based ionomeric membranes and bipolar plates based on inexpensive materials. Contrasting the analogous proton-exchange-membrane system (PEM-WE), where pure water is circulated (no support electrolyte), the current generation of AEM-WEs necessitates the circulation of a dilute aqueous alkaline electrolyte for reaching high energy efficiency and durability. For several reasons, including but not limited to lower cost of balance-of-plant, lower operating cost and improved device's lifetime, achieving high cell efficiency and performance using an alkali-free water feed is highly desirable. In this review, we develop and build a foundational understanding of AEM-WEs operating with pure water, as well as discuss the effects of operating with natural water feeds like seawater. After a discussion of the possible advantages of pure-water-fed AEM-WEs, we cover the thermodynamic and kinetic processes involved in AEM-WE, followed by a detailed review of materials and components and their integration in the device. We highlight the influence of electrolyte composition and alkali/electrolyte-free feed on the membrane-electrode assembly, ionomers, electrocatalysts, porous transport layer, bipolar plates and operating configuration. We provide evidence for how the pure water feed engenders several issues related to the degradation of device components and propose mitigation strategies.

Electrodes↗

Lunar South Pole Regenerative Fuel Cell System Efficiency Analysis

It is expected that future NASA mission energy storage needs can be adequately met by regenerative fuel cells (RFCs). Aerospace RFCs package proton exchange membrane (PEM) electrochemical conversion devices based on hydrogen, oxygen, and water. To optimize system designs and direct further development, the most useful system metric is round-trip efficiency (RTE). Improving RTE generally increases specific energy and reduces system mass. The following analysis models the impact of several factors on RTE for RFCs at the lunar south pole scaling from 0.1 kW to 50 kW. The analysis demonstrates that higher electrolyzer operational pressure most negatively impacts both RFC RTE and specific energy. Optimal electrolyzer membrane thickness is evaluated as a function of operational current density and pressure. Reactant storage heating and power management losses are significant for RFCs of any scale but are reduced in impact at the south pole compared to colder equator applications. Solenoid valve power remains a noticeable parasitic load for smaller RFCs. Larger electrolyzers enable higher peak theoretical efficiencies when recharging at higher rates, if the RFC can be coupled with a corresponding higher power source. RFC design is a compromise of many interrelated factors, but this analysis provides a starting point for difficult decisions that must be made when designing a lunar south pole RFC.

regenerative fuel cell↗

Introducing a novel technique for measuring hydrogen crossover in membrane-based electrochemical cells

Hydrogen crossover that is the unwanted hydrogen permeation across the membrane driven by the difference of gas concentrations causes a critical concern of safety and efficiency for electrochemical cells, such as fuel cells and electrolyzer cells. Although the hydrogen crossover measurement in fuel cells that employ platinum based catalysts is simple and widely used in laboratory settings, it is questionable to apply existing limiting current method to water electrolyzer cells and alkaline exchange membrane (AEM) systems, which is due to the typical catalyst materials used and membrane properties, respectively. In this work, we demonstrate the operation of a compact and low-cost method of measuring hydrogen crossover that works for both AEM and proton exchange membrane (PEM) systems. The method entails a tandem configuration that utilizes an upstream crossover cell with a downstream cell in hydrogen pump configuration to measure the crossover in the cell of interest. We have successfully measured the hydrogen crossover with different membranes at various differential pressures. The developed method can be applied to catalyst-free membranes (both PEM and AEM) as well as PGM free catalyst containing cells. It will be a promising technique for measuring hydrogen crossover in-situ for a real operating membraned-based electrochemical cell or stack.

08 HYDROGEN↗

Advanced Water Purification System for In Situ Resource Utilization

A main goal in the field of In Situ Resource Utilization is to develop technologies that produce oxygen from regolith to provide consumables to an extraterrestrial outpost. The processes developed reduce metal oxides in the regolith to produce water, which is then electrolyzed to produce oxygen. Hydrochloric and hydrofluoric acids are byproducts of the reduction processes, which must be removed to meet electrolysis purity standards. We previously characterized Nation, a highly water selective polymeric proton-exchange membrane, as a filtration material to recover pure water from the contaminated solution. While the membranes successfully removed both acid contaminants, the removal efficiency of and water flow rate through the membranes were not sufficient to produce large volumes of electrolysis-grade water. In the present study, we investigated electrodialysis as a potential acid removal technique. Our studies have shown a rapid and significant reduction in chloride and fluoride concentrations in the feed solution, while generating a relatively small volume of concentrated waste water. Electrodialysis has shown significant promise as the primary separation technique in ISRU water purification processes.

Anthony, Stephen M.↗

Advanced Water Purification System for In Situ Resource Utilization Project

A main goal in the field of In Situ Resource Utilization is to develop technologies that produce oxygen from regolith to provide consumables to an extratrrestrial outpost. The processes developed reduce metal oxides in the regolith to produce water, which is then electrolyzed to produce oxygen. Hydrochloric and hydrofluoric acids are byproducts of the reduction processes, which must be removed to meet electrolysis purity standards. We previously characterized Nation, a highly water selective polymeric proton-exchange membrane, as a filtrtion material to recover pure water from the contaminated solution. While the membranes successfully removed both acid contaminants, the removal efficiency of and water flow rate through the membranes were not sufficient to produce large volumes of electrolysis-grade water. In the present study, we investigated electrodialysis as a potential acid removable technique. Our studies have show a rapid and significant reduction in chloride and fluoride concentrations in the feed solution, while generating a relatively small volume of concentrated waste water. Electrodialysis has shown significant promise as the primary separation technique in ISRU water purification processes.

Technology Portfolio System↗

Intermediate-Temperature Proton Exchange Membranes Based on Cerium Ultraphosphate Composited with Polybenzimidazole

This paper reports the rational fabrication and structural, thermal, mechanical and electrochemical characterization of a new type of intermediate-temperature (IT) polymer-inorganic composite (PIC) proton exchange membranes (PEMs) that are made of cerium ultraphosphate (CeP 5 O 14 —CUP) as the solid-state proton conductor composited with a high-temperature (HT) polybenzimidazole (PBI) as the polymeric binder. Here, flexible PBI-CUP PIC membranes with the thickness of ~135 μ m and CUP mass fraction of up to 75% were prepared by solution-casting without additional acid-doping (e.g., phosphoric acid). The proton conductivity of the fabricated IT-PIC-PEMs was up to 5.80 × 10 –2 S cm –1 as measured from a prototype IT PEM fuel cell (PEMFC) operated at 200 °C in the humidified hydrogen and air environment. This type of IT-PIC-PEMs also demonstrated sufficient mechanical strength and flexibility, excellent thermal stability (up to 350 °C), and very good durability of the proton conductivity (within the test duration of 500 h). The present experimental study shows the promising future of the IT-PIC-PEMs for applications in various IT electrochemical processes including IT-PEMFCs, IT-electrolyzers, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas Permeability Test Protocol for Ion-Exchange Membranes

The membrane-based electrolysis of water is a growing topic of interest due to the advantages of employing membranes in hydrogen production efficiency and system safety over the traditional alkaline water electrolysis. Ion-exchange membranes with low gas permeability are highly desirable for stable and safe operation of membrane-based water-splitting technologies, hence gas permeability through ion-exchange membranes needs to be properly assessed with standardized methods. We addressed three methods to measure gas permeability of ion-exchange membranes, a pressure permeation cell, chronoamperometry microelectrodes, and in situ testing of the membrane electrode assembly, and provide a guideline for choosing the appropriate method for the targeted operating conditions of the water electrolyzers.

08 HYDROGEN↗

Roll to Roll (R2R) Manufacturing of Electrolysis Electrodes for Low Cost Hydrogen Production: Cooperative Research and Development Final Report, CRADA Number CRD-18-00780

NREL, Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL), which are also referred to collectively herein as the "Contractors" will perform electrode ink development and characterization, focusing on 1) inks with appropriate properties for R2R (gravure and slot-die) coating onto PFSA membrane and 2) catalysts suitable for electrolysis. Participant will develop acceptance criteria and characterization methods for direct coating on the membrane. The purpose of this project is to show feasibility for cost reduction of the electrode through increased throughput and improved material utilization. Successful completion of this project will result in more affordable hydrogen production via proton exchange membrane (PEM) electrolysis by substantially reducing the anode precious metal content and catalyst-coated membrane processing costs. Assists laboratory in achieving programmatic scope, adds new capability to the laboratory's core competencies. This project uses and enhances the laboratory's core competencies, and enhances U.S. competitiveness by utilizing DOE developed intellectual property and/or capabilities. This project will benefit the Fuel Cell subprogram within the EERE Fuel Cell Technologies Office (FCTO) by actively developing materials, formulations, components, and processes for PEM electrolyzer stacks for overcoming critical technical barriers to widespread hydrogen production for zero-emission transportation applications. Through this JWS, NREL, ANL and ORNL are assisting a key domestic industry partner, Proton Energy Systems, Inc., in the area of low-cost electrolyzer electrode formulation and coating technology. After completion of this project, NREL, ANL and ORNL will be able to verify whether the direct deposit coating processes investigated are suitable for producing CCMs for PEM electrolyzers, which is of great interest and benefit to the DOE EERE Fuel Cell Technologies Office (FCTO) and H2@Scale missions.

08 HYDROGEN↗

Operation of the 25kW NASA Lewis Research Center Solar Regenerative Fuel Cell Tested Facility

Assembly of the NASA Lewis Research Center(LeRC)Solar Regenerative Fuel Cell (RFC) Testbed Facility has been completed and system testing has proceeded. This facility includes the integration of two 25kW photovoltaic solar cell arrays, a 25kW proton exchange membrane (PEM) electrolysis unit, four 5kW PEM fuel cells, high pressure hydrogen and oxygen storage vessels, high purity water storage containers, and computer monitoring, control and data acquisition.

Solar Regenerative Fuel Cell electrolyzer↗

Measurement of Local Impedance Characteristics of In-Plane PEM Electrolyzer Component Features via Segmented Cell

Segmented cells are a class of advanced diagnostic devices that enable the measurement of current distribution within the active area of an electrochemical cell, allowing for the evaluation of localized impacts from operating conditions, flow fields and component inhomogeneities. Segmented cell devices have been applied to support R&D efforts for the advancement of polymer electrolyte membrane fuel cell technologies and more recently proton exchange membrane water electrolysis (PEMWE). Beyond current density distributions, segmented cells have been successfully deployed to collect the distribution of other relevant parameters such as high frequency resistance and electrode potentials. Very recently, a promising impedance method has been reported for water electrolysis where a one-dimensional segmented cell is coupled to a multichannel potentiostat, to enable the measurement of local cell impedances, further expanding the diagnostic capabilities of the segmented cell. In this study, we will present recent efforts to accurately measure local impedance characteristics for a PEMWE cell using a two-dimensional segmented cell device coupled with a multichannel potentiostat. The distribution of local resistances, i.e. high frequency, charge transfer, mass transport and catalyst layer, and iR-free overpotentials were successfully measured after eliminating sources of random and systematic error. We will discuss the application of this diagnostic on a cell containing a 1 cm feature simulating an ionomer skin. The results from these tests give insights if such an irregularity needs to be classified as a defect, and highlight the usefulness of coupling impedance spectroscopy with segmented cells for holistic spatial diagnostics of electrochemical devices.

08 HYDROGEN↗

Tantalum oxide stabilized molybdenum-doped ruthenium oxide electrocatalysts for PEM water electrolysis

Proton exchange membrane (PEM) water electrolysis offers key advantages, including high current density, high efficiency, and compact system architecture for hydrogen production. However, its widespread implementation is limited by the scarcity and high cost of Ir-based anodic catalysts. Herein, we report an Ir-free electrocatalyst for the acidic oxygen evolution reaction (OER): tantalum oxide (TaO x )–coated molybdenum-doped RuO 2 (TaO x -MoRuO 2 ). The catalyst exhibits a low overpotential of 180 mV at 10 mA cm -2 and excellent durability, with a degradation rate of 0.034 mV h -1 over a 150-hour test at 50 mA cm -2 —surpassing other Ru-based catalysts evaluated under similar conditions. A PEM electrolyzer employing TaO x -MoRuO 2 as the anode maintained stable operation for 100 hours at 500 mA cm -2 . In conclusion, the TaO x coating layer suppresses Ru and Mo dissolution, thus enhancing their stability likely via interfacial electronic reconfiguration of Ru and Mo mediated by bridging oxygen atoms.

Durability↗

Performance improvement of proton exchange membrane water electrolysis by surface modification of porous transport layers

Proton exchange membrane water electrolysis (PEMWE) is a promising option for hydrogen production from a variety of energy sources. Cost-effective production of hydrogen with PEMWE requires reduction of costly precious metals as well as optimization of the components and interfaces in the cell. The interface between the platinum-coated titanium porous transport layer (PTL) and catalyst layer (CL) significantly impacts the performance of the electrolyzer cell. Here, we report on two PTL modification methods, mechanical abrasion and chemical etching, which we find improve PEMWE performance by lowering the resistance of the PTL/CL interface. The PTL surface modifications enabled performance improvements up to 77 mV at 4 A cm −2 and reduction of the high frequency resistance, demonstrating that the resistance of the PTL/CL interface is a significant factor in the cell performance. The PTL surface roughness was varied using abrasive materials ranging from 0.1 to 140 μm in grain sizes and chemical etching was found to also increase the surface roughness. The surface roughness was quantified using confocal laser microscopy and the surface oxidation was measured using X-ray photoemission spectroscopy. These results demonstrate that both increasing surface roughness and oxide removal contribute to lowering the PTL/CL interfacial resistance and increasing cell performance.

08 HYDROGEN↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

Thermal System Modeling for Lunar and Martian Surface Regenerative Fuel Cell Systems

The Advanced Exploration Systems (AES) Advanced Modular Power Systems (AMPS) Project is investigating different power systems for various lunar and Martian mission concepts. The AMPS Fuel Cell (FC) team has created two system-level models to evaluate the performance of regenerative fuel cell (RFC) systems employing different fuel cell chemistries. Proton Exchange Membrane fuel cells PEMFCs contain a polymer electrolyte membrane that separates the hydrogen and oxygen cavities and conducts hydrogen cations (protons) across the cell. Solid Oxide fuel cells (SOFCs) operate at high temperatures, using a zirconia-based solid ceramic electrolyte to conduct oxygen anions across the cell. The purpose of the modeling effort is to down select one fuel cell chemistry for a more detailed design effort. Figures of merit include the system mass, volume, round trip efficiency, and electrolyzer charge power required. PEMFCs operate at around 60 degrees Celsius versus SOFCs which operate at temperatures greater than 700 degrees Celsius. Due to the drastically different operating temperatures of the two chemistries the thermal control systems (TCS) differ. The PEM TCS is less complex and is characterized by a single pump cooling loop that uses deionized water coolant and rejects heat generated by the system to the environment via a radiator. The solid oxide TCS has its own unique challenges including the requirement to reject high quality heat and to condense the steam produced in the reaction. This paper discusses the modeling of thermal control systems for an extraterrestrial RFC that utilizes either a PEM or solid oxide fuel cell.

thermal modeling↗

Thermal Design for Extra-Terrestrial Regenerative Fuel Cell System

The Advanced Exploration Systems (AES) Advanced Modular Power Systems (AMPS) Project is investigating different power systems for various lunar and Martian mission concepts. The AMPS Fuel Cell (FC) team has created two system-level models to evaluate the performance of regenerative fuel cell (RFC) systems employing different fuel cell chemistries. Proton Exchange Membrane fuel cells PEMFCs contain a polymer electrolyte membrane that separates the hydrogen and oxygen cavities and conducts hydrogen cations (protons) across the cell. Solid Oxide fuel cells (SOFCs) operate at high temperatures, using a zirconia-based solid ceramic electrolyte to conduct oxygen anions across the cell. The purpose of the modeling effort is to down select one fuel cell chemistry for a more detailed design effort. Figures of merit include the system mass, volume, round trip efficiency, and electrolyzer charge power required. PEMFCs operate at around 60 C versus SOFCs which operate at temperatures greater than 700 C. Due to the drastically different operating temperatures of the two chemistries the thermal control systems (TCS) differ. The PEM TCS is less complex and is characterized by a single pump cooling loop that uses deionized water coolant and rejects heat generated by the system to the environment via a radiator. The solid oxide TCS has its own unique challenges including the requirement to reject high quality heat and to condense the steam produced in the reaction. This paper discusses the modeling of thermal control systems for an extraterrestrial RFC that utilizes either a PEM or solid oxide fuel cell.

thermal modeling↗

Synthesis of highly sulfonated 2,6-diphenyl-p-Phenylene oxide: A highly conductive membrane

Highly sulfonated aromatic polymers are desired for the possible highest performance of polymer electrolytes in fuel cells and electrolyzer applications. Here, we reported the method to prepare highly sulfonated 2,6-diphenyl-p-phenylene oxide (SP3O), a commercially available aromatic polymer, with the highest IEC of 4.42 meq/g. Three sulfonation reagents including chlorosulfonic acid (HSO3Cl), concentrated sulfuric acid (conc. H2SO4), and trimethylsilyl chlorosulfonate (TMSCS) were investigated for single and two-step sulfonation reactions. In addition, DMSO-assisted thermal crosslinking method was applied to prepare crosslinked SP3O membranes to improve their mechanical strength and film-forming ability. Proton exchange membrane from crosslinked SP3O displayed a proton conductivity as high as 250 mS/cm at 95 % RH and 60 °C.

Khomein, Piyachai↗

Contaminant Removal from Oxygen Production Systems for In Situ Resource Utilization

The In Situ Resource Utilization (ISRU) project has been developing technologies to produce oxygen from lunar regolith to provide consumables to a lunar outpost. The processes developed reduce metal oxides in the regolith to produce water, which is then electrolyzed to produce oxygen. Hydrochloic and hydrofluoric acids are byproducts of the reduction processes, as halide minerals are also reduced at oxide reduction conditions. Because of the stringent water quality requirements for electrolysis, there is a need for a contaminant removal process. The Contaminant Removal from Oxygen Production Systems (CROPS) team has been developing a separation process to remove these contaminants in the gas and liquid phase that eliminates the need for consumables. CROPS has been using Nafion, a highly water selective polymeric proton exchange membrane, to recover pure water from the contaminated solution. Membrane thickness, product stream flow rate, and acid solution temperature and concentration were varied with the goal of maximizing water permeation and acid rejection. The results show that water permeation increases with increasing solution temperature and product stream flow rate, while acid rejection increases with decreasing solution temperature and concentration. Thinner membranes allowed for higher water flux and acid rejection than thicker ones. These results were used in the development of the hardware built for the most recent Mars ISRU demonstration project.

Anthony, Stephen M.↗