Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Updated OpenStudio Small and Medium Office Prototype Models

The U.S. Department of Energy supports the development of commercial building energy codes and standards by participating in industry review, update processes, and providing technical analyses to support both published model codes and potential changes. In support of ANSI/ASHRAE/IES Standard 90.1 and International Energy Conservation Code, 16 commercial prototype building models were developed that cover 80% of the commercial building floor area in the United States for new construction, including both commercial buildings and mid- to high-rise residential buildings, across all U.S. climate zones. Of these, the small, medium, and large office buildings take about 12% of total commercial building floor area.Currently, small, medium, and large office prototype building models have simplified, single space type, while other building types includes more detailed space types. As such, the office prototype could not be easily used to properly assess changes (i.e. measures applied) to difference spaces commonly found in an office. This work has added new space types to the small and medium office, with properties based on several vintages of ASHRAE Standard 90.1 in different climate zones, and compared energy use of these newly-improved models with that of the original models.

Im, Piljae↗

Prototype Development of Remote Operated Hot Uniaxial Press (ROHUP) to Fabricate Advanced Tc-99 Bearing Ceramic Waste Forms - 13381

The objective of this senior student project is to design and build a prototype construction of a machine that simultaneously provides the proper pressure and temperature parameters to sinter ceramic powders in-situ to create pellets of rather high densities of above 90% (theoretical). This ROHUP (Remote Operated Hot Uniaxial Press) device is designed specifically to fabricate advanced ceramic Tc-99 bearing waste forms and therefore radiological barriers have been included in the system. The HUP features electronic control and feedback systems to set and monitor pressure, load, and temperature parameters. This device operates wirelessly via portable computer using Bluetooth{sup R} technology. The HUP device is designed to fit in a standard atmosphere controlled glove box to further allow sintering under inert conditions (e.g. under Ar, He, N{sub 2}). This will further allow utilizing this HUP for other potential applications, including radioactive samples, novel ceramic waste forms, advanced oxide fuels, air-sensitive samples, metallic systems, advanced powder metallurgy, diffusion experiments and more. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Gamification to Enhance Mastery of Network Security Concepts

Gamification has proven to be effective in engaging and encouraging people to work towards and achieve goals. Many students struggle to focus on schoolwork, due to a lack of interest, lack of understanding, or other factors unique to the student. Applying gamification elements to education can help engage these students in learning their course material and help them excel academically. This study examines the effectiveness of using gamification techniques to enhance the learning experience in college Computer Science courses. A video game application is utilized to review and reinforce cybersecurity concepts that students have already been taught in class. Previous work has been made on a prototype game build that teaches about ARP (Address Resolution Protocol) components. The focus of this study is to refine and develop the structure of the prototype into a more interactive and enjoyable format with non-competitive and captivating activities that allow students to study at their own pace. An updated version of the game was created that focused on reaching a balance between education and entertainment. The game was used by students enrolled in a cybersecurity class, where pre-survey, post-survey and a focus group interview were conducted to determine how effective the updated version is compared to the current build, in addition to how effective the gamification method is regarding student retention of taught material. The pre-survey and post-survey results revealed an increase in interest and mastery of cybersecurity concepts as a result of playing the game. Students found value in the game as both a method of reviewing material taught in class and an entertaining and engaging game. These results show potential in using gamification in cybersecurity and education.

Hilliard, Kevin↗

Anti-Idling Battery for Truck Applications

In accordance to the Assistance Agreement DE-EE0001036, the objective of this project was to develop an advanced high voltage lithium-ion battery for use in an all-electric HVAC system for Class-7-8 heavy duty trucks. This system will help heavy duty truck drivers meet the tough new anti-idling laws being implemented by over 23 states. Quallion will be partnering with a major OEM supplier of HVAC systems to develop this system. The major OEM supplier will provide Quallion the necessary interface requirements and HVAC hardware to ensure successful testing of the all-electric system. At the end of the program, Quallion will deliver test data on three (3) batteries as well as test data for the prototype HVAC system. The objectives of the program are: (1) Battery Development - Objective 1 - Define battery and electronics specifications in preparation for building the prototype module. (Completed - summary included in report) and Objective 2 - Establish a functional prototype battery and characterize three batteries in-house. (Completed - photos and data included in report); (2) HVAC Development - Objective 1 - Collaborate with manufacturers to define HVAC components, layout, and electronics in preparation for establishing the prototype system. (Completed - photos and data included in report) and Objective 2 - Acquire components for three functional prototypes for use by Quallion. (Completed - photos and data included in report).

25 ENERGY STORAGE↗

A prototype Upper Atmospheric Research Collaboratory (UARC)

The National Collaboratory concept has great potential for enabling 'critical mass' working groups and highly interdisciplinary research projects. We report here on a new program to build a prototype collaboratory using the Sondrestrom Upper Atmospheric Research Facility in Kangerlussuaq, Greenland and a group of associated scientists. The Upper Atmospheric Research Collaboratory (UARC) is a joint venture of researchers in upper atmospheric and space science, computer science, and behavioral science to develop a testbed for collaborative remote research. We define the 'collaboratory' as an advanced information technology environment which enables teams to work together over distance and time on a wide variety of intellectual tasks. It provides: (1) human-to-human communications using shared computer tools and work spaces; (2) group access and use of a network of information, data, and knowledge sources; and (3) remote access and control of instruments for data acquisition. The UARC testbed is being implemented to support a distributed community of space scientists so that they have network access to the remote instrument facility in Kangerlussuaq and are able to interact among geographically distributed locations. The goal is to enable them to use the UARC rather than physical travel to Greenland to conduct team research campaigns. Even on short notice through the collaboratory from their home institutions, participants will be able to meet together to operate a battery of remote interactive observations and to acquire, process, and interpret the data.

Clauer, C. R.↗

NIST Infiltration Tools for Commercial Buildings

The Department of Energy estimates that infiltration through building envelopes accounted for 6 % of the total energy consumed by commercial buildings and 21 % of the heating and cooling energy. Air barrier requirements are now being included in ASHRAE Standards 90.1 and 189.1 and other construction requirements. The energy impacts of unintended infiltration on building energy use can be significant, but current energy simulation software and design methods are generally not able to accurately account for envelope infiltration and the impacts of improved airtightness. NIST has been developing tools to better account for infiltration in building energy models. The tools that will be discussed in this paper include: CONTAM Results Export Tool; weather-correlated infiltration inputs for prototype commercial buildings and the associated Open Studio Measures; and a web-based tool to evaluate the energy savings of building envelope airtightening, which was developed with the Oak Ridge National Laboratory and the Air Barrier Association of America. This paper briefly describes each tool, their applications, and the benefits of using each. All of the tools are publicly available at no cost.

Ng, Lisa↗

Energy and Energy Cost Savings Analysis of the 2018 IECC for Commercial Buildings

The U.S. Department of Energy (DOE) Building Energy Codes Program supports the development and implementation of building energy codes and standards, which set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. As required by federal statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2016 would achieve greater energy efficiency in buildings compared to the 2013 edition of the standard. In support of DOE’s determination, Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2016 (DOE 2017). While Standard 90.1 is the national model energy standard for commercial buildings (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether new buildings constructed to the commercial energy efficiency provisions of the 2018 IECC would save energy and energy costs as compared to the 2015 IECC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Technology for Starlight Suppression via an External Occulter

External occulters provide the starlight suppression needed for detecting and characterizing exoplanets with a much simpler telescope and instrument than is required for the equivalent performing coronagraph. In this paper we describe progress on our Technology Development for Exoplanet Missions project to design, manufacture, and measure a prototype occulter petal. We focus on the key requirement of manufacturing a precision petal while controlling its shape within precise tolerances. The required tolerances are established by modeling the effect that various mechanical and thermal errors have on scatter in the telescope image plane and by suballocating the allowable contrast degradation between these error sources. We discuss the deployable starshade design, representative error budget, thermal analysis, and prototype manufacturing. We also present our meteorology system and methodology for verifying that the petal shape meets the contrast requirement. Finally, we summarize the progress to date building the prototype petal.

high-contrast imaging↗

Cinco Ranch, Pulte Homes, Houston, Texas

Pulte-Houston began constructing Building America prototype houses in late 2000. They have overcome many challenges to now produce outstanding energy-efficient homes.

building america, residential, Energy↗

Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes

This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH), which is intended to make significant progress toward performing as zero-net-energy ready. The scope of this project involved building four HPMH prototypes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual percent savings varies depending on choice of heating equipment and climate zone). Previous phases of this project created a HPMH specification and prototyped individual measures from the package to obtain engineering approvals and develop preliminary factory construction processes. This report describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability during 2014. Monitoring is expected to continue into 2016.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Construction of Prototype Dark Matter Detectors: ΔLepton Quark Studies (LQS)

The Lepton Quark Studies (LQS) group is engaged in searching for dark matter using the Dark Matter Time Projection Chamber (DMTPC) at the Waste Isolation Pilot Plant (WIPP) (Carlsbad, NM). DMTPC is a direction-sensitive dark matter detector designed to measure the recoil direction and energy deposited by fluorine nuclei recoiling from the interaction with incident WIMPs. In the past year, the major areas of progress have been: • to publish the first dark matter search results from a surface run of the DMTPC prototype detector, • to build and install the 10L prototype in the underground laboratory at WIPP which will house the 1 m 3 detector, and • to demonstrate charge and PMT readout of the TPC using prototype detectors, which allow triggering and z measurement to be used in the 1 m 3 detector under development.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recommended Changes to Interval Management to Achieve Operational Implementation

A 19-day flight test of an Interval Management (IM) avionics prototype was conducted in Washington State using three aircraft to precisely achieve and maintain a spacing interval behind the preceding aircraft. NASA contracted with Boeing, Honeywell, and United Airlines to build this prototype, and then worked closely with them, the FAA, and other industry partners to test this prototype in flight. Four different IM operation types were investigated during this test in the en route, arrival, and final approach phases of flight. Many of the IM operations met or exceeded the design goals established prior to the test. However, there were issues discovered throughout the flight test, including the rate and magnitude of IM commanded speed changes and the difference between expected and actual aircraft deceleration rates.

Baxley, Brian↗

Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes

This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH). The scope of this project involved building four HPMH prototypes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual % savings varies depending on choice of heating equipment and climate zone). The HPMH home is intended to make significant progress toward performing as zero-net-energy ready. Previous phases of this project created a HPMH specification and prototyped individual measures from the package to obtain engineering approvals and develop preliminary factory construction processes. This report describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability during 2014. Monitoring is expected to continue into 2016.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Progressive Modeling, Manufacture, and Testing of Composite Shield for Turbine Engine Blade Containment

An effective design methodology was established for composite jet engine containment structures. The methodology included the development of the full and reduced size prototypes, and FEA models of the containment structure, experimental and numerical examination of the modes of failure clue to turbine blade out event, identification of materials and design candidates for future industrial applications, and design and building of prototypes for testing and evaluation purposes.

Binienda, Wieslaw K.↗

Wireless Sensor Networks for Developmental and Flight Instrumentation

Wireless sensor networks (WSN) based on the IEEE 802.15.4 Personal Area Network and ZigBee Pro 2007 standards are finding increasing use in home automation and smart energy markets providing a framework for interoperable software. The Wireless Connections in Space Project, funded by the NASA Engineering and Safety Center, is developing technology, metrics and requirements for next-generation spacecraft avionics incorporating wireless data transport. The team from Stennis Space Center and Mobitrum Corporation, working under a NASA SBIR grant, has developed techniques for embedding plug-and-play software into ZigBee WSN prototypes implementing the IEEE 1451 Transducer Electronic Datasheet (TEDS) standard. The TEDS provides meta-information regarding sensors such as serial number, calibration curve and operational status. Incorporation of TEDS into wireless sensors leads directly to building application level software that can recognize sensors at run-time, dynamically instantiating sensors as they are added or removed. The Ames Research Center team has been experimenting with this technology building demonstration prototypes for on-board health monitoring. Innovations in technology, software and process can lead to dramatic improvements for managing sensor systems applied to Developmental and Flight Instrumentation (DFI) aboard aerospace vehicles. A brief overview of the plug-and-play ZigBee WSN technology is presented along with specific targets for application within the aerospace DFI market. The software architecture for the sensor nodes incorporating the TEDS information is described along with the functions of the Network Capable Gateway processor which bridges 802.15.4 PAN to the TCP/IP network. Client application software connects to the Gateway and is used to display TEDS information and real-time sensor data values updated every few seconds, incorporating error detection and logging to help measure performance and reliability in relevant target environments. Test results from our prototype WSN running the Mobitrum software system are summarized and the implications to the scalability and reliability for DFI applications are discussed. Our demonstration system, incorporating sensors for life support system and structural health monitoring is described along with test results obtained by running the demonstration prototype in relevant environments such as the Wireless Habitat Testbed at Johnson Space Center in Houston. An operations concept for improved sensor process flow from design to flight test is outlined specific to the areas of Environmental Control and Life Support System performance characterization and structural health monitoring of human-rated spacecraft. This operations concept will be used to highlight the areas where WSN technology, particularly plug-and-play software based on IEEE 1451, can improve the current process, resulting in significant reductions in the technical effort, overall cost and schedule for providing DFI capability for future spacecraft. RELEASED -

Alena, Richard↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 IECC Determination of Energy Savings: Preliminary Technical Analysis

This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy-efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗