Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse analysis measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Geoscience Laser Ranging System - Estimated accuracy of geodetic parameters and their dependence on system characteristics

Covariance analysis of the performance of the Geoscience Laser Ranging System (GLRS) indicates that three-dimensional relative positions can be recovered to an accuracy of several millimeters over spatial scales from a few kilometers to several hundred kilometers and over temporal scales as short as several days. The key factors influencing the accuracy are range noise, number of targets and their locations, system pointing capability, dwell time on the targets, orbital geometry, and gravity field uncertainties. Based on the present trade-off studies, GLRS is designed to provide range measurements with 10 mm or better accuracy, fire at a rate of 40 pulses-per-second, point over a cone extending to 50 deg from nadir, and operate with a dwell time on individual targets of 2 s or less. Given a strain rate of 10 to the -14th/s, estimated GLRS accuracy parameters suggest that the deformation can be detected in less than a month if it extends over 100 km and in less than 6 months if it extends over 10 km.

Cohen, Steven C.↗

Pulsed Plasma Thruster Plume Study: Symmetry and Impact on Spacecraft Surfaces

Twenty-four witness plates were positioned on perpendicular arrays near a breadboard Pulsed Plasma Thruster (PPT) to collect plume constituents for analysis. Over one million shots were fired during the experiment at 43 J using fluorocarbon polymer propellant. The asymmetry of the film deposition on the witness plates was investigated with mass and thickness measurements and correlated with off-axis thrust vector measurements. The composition of the films was determined. The transmittance and reflectance of the films were measured and the absorption coefficients were calculated in the wavelength range from 350 to 1200 mn. These data were applied to calculate the loss in signal intensity through the films, which will impact the visibility of spaceborne interferometer systems positioned by these thrusters.

Arrington, Lynn A.↗

Ground-Based Lidar Measurements of Aerosols During ACE-2: Instrument Description, Results, and Comparisons with Other Ground-Based and Airborne Measurements

A micro-pulse lidar system (MPL) was used to measure the vertical and horizontal distribution of aerosols during the Aerosol Characterization Experiment 2 (ACE-2) in June and July of 1997. The MPL measurements were made at the Izana observatory (IZO), a weather station located on a mountain ridge (28 deg 18 min N, 16 deg 30 min W, 2367 m asl) near the center of the island of Tenerife, Canary Islands. The MPL was used to acquire aerosol backscatter, extinction, and optical depth profiles for normal background periods and periods influenced by Saharan dust from North Africa. System tests and calibration procedures are discussed, and an analysis of aerosol optical profiles acquired during ACE-2 is presented. MPL data taken during normal IZO conditions (no dust) showed that upslope aerosols appeared during the day and dissipated at night and that the layers were mostly confined to altitudes a few hundred meters above IZO. MPL data taken during a Saharan dust episode on 17 July showed that peak aerosol extinction values were an order of magnitude greater than molecular scattering over IZO, and that the dust layers extended to 5 km asl. The value of the dust backscatter-extinction ratio was determined to be 0.027 +/- 0.007 sr(exp -1). Comparisons of the MPL data with data from other collocated instruments showed good agreement during the dust episode.

Welton, Ellsworth J.↗

Significant variation from a 1/R-squared potential in the cumulative flux determined from the Giotto Comet Halley Dust Impact Experiment

The Dust Impact Detection System (DIDSY) aboard the Giotto spacecraft provided the information on the dust flux, mass spectrum, and cumulative mass distribution flux in the coma of Comet Halley. Analysis of discrete pulse height data of cometary particles for the mass range of particles between 4.0 x 10 to the -10th g and 6.0 x 10 to the -6th g registered by the Giotto DIDSY detectors 2, 3, and 4 has been completed, and a cumulative flux has been determined for this size range of particles. Inside the cometopause, anomalous peaks have been identified as deviation from a 1/R-squared curve in both pre- and postencounter measurements.

Alexander, W. M.↗

High-Performance Scanning Acousto-Ultrasonic System

A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.

Roth, Don↗

Towards a Radar/Radiometer Mode on the Dual-Frequency, Dual-Polarized, Doppler Radar (D3R) System

The dual-­frequency, dual-­polarized, Doppler radar (D3R) system was developed in support of the ground validation segment of the Global Precipitation Measurement (GPM) mission. Although its main purpose is to provide active, Ku/Ka­‐band, dual­‐polarized measurements of precipitation, the design presents an opportunity to study its operation in an active/passive mode. The opportunity arises from use of solid-­state transmitters employing a multi­‐frequency waveform and receiving system. Typically, a sequence of three pulses separated in frequency is transmitted to achieve its radar sensitivity and minimum range. However, one of the three pulses can be disabled with a tolerable decrease in sensitivity and its receive channel can be repurposed to support passive measurements. This work focuses on progress in the characterization of the Ku-­band H polarized passive channel operating simultaneously with two active as a step towards the provision of brightness temperatures along with the other radar derived products. The methodology developed will be applied to the V polarized channel and Ka­‐band subsystem in the near future. The study consists on the analysis of the antenna performance, receiver architecture, transfer function and achievable number of independent samples, calibration method and preliminary observation analysis. All within the context of the instrument's current configuration and possible future improvements.

radar↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

The input/output characteristics of an ultrasonic testing system used for stress wave factor measurements were studied. The fundamentals of digital signal processing are summarized. The inputs and outputs are digitized and processed in a microcomputer using digital signal processing techniques. The entire ultrasonic test system, including transducers and all electronic components, is modeled as a discrete-time linear shift-invariant system. Then the impulse response and frequency response of the continuous time ultrasonic test system are estimated by interpolating the defining points in the unit sample response and frequency response of the discrete time system. It is found that the ultrasonic test system behaves as a linear phase bandpass filter. Good results were obtained for rectangular pulse inputs of various amplitudes and durations and for tone burst inputs whose center frequencies are within the passband of the test system and for single cycle inputs of various amplitudes. The input/output limits on the linearity of the system are determined.

Karaguelle, H.↗

NASA Tech Briefs, September 2007

Topics covered include; Rapid Fabrication of Carbide Matrix/Carbon Fiber Composites; Coating Thermoelectric Devices To Suppress Sublimation; Ultrahigh-Temperature Ceramics; Improved C/SiC Ceramic Composites Made Using PIP; Coating Carbon Fibers With Platinum; Two-Band, Low-Loss Microwave Window; MCM Polarimetric Radiometers for Planar Arrays; Aperture-Coupled Thin-Membrane L-Band Antenna; WGM-Based Photonic Local Oscillators and Modulators; Focal-Plane Arrays of Quantum-Dot Infrared Photodetectors; Laser Range and Bearing Finder With No Moving Parts; Microrectenna: A Terahertz Antenna and Rectifier on a Chip; Miniature L-Band Radar Transceiver; Robotic Vision-Based Localization in an Urban Environment; Programs for Testing an SSME-Monitoring System; Cathodoluminescent Source of Intense White Light; Displaying and Analyzing Antenna Radiation Patterns; Payload Operations Support Team Tools; Space-Shuttle Emulator Software; Soft Real-Time PID Control on a VME Computer; Analyzing Radio-Frequency Coverage for the ISS; Nanorod-Based Fast-Response Pressure-Sensitive Paints; Capacitors Would Help Protect Against Hypervelocity Impacts; Diaphragm Pump With Resonant Piezoelectric Drive; Improved Quick-Release Pin Mechanism; Designing Rolling-Element Bearings; Reverse-Tangent Injection in a Centrifugal Compressor; Inertial Measurements for Aero-assisted Navigation (IMAN); Analysis of Complex Valve and Feed Systems; Improved Path Planning Onboard the Mars Exploration Rovers; Robust, Flexible Motion Control for the Mars Explorer Rovers; Solar Sail Spaceflight Simulation; Fluorine-Based DRIE of Fused Silica; Mechanical Alloying for Making Thermoelectric Compounds; Process for High-Rate Fabrication of Alumina Nanotemplates; Electroform/Plasma-Spray Laminates for X-Ray Optics; An Automated Flying-Insect Detection System; Calligraphic Poling of Ferroelectric Material; Blackbody Cavity for Calibrations at 200 to 273 K; KML Super Overlay to WMS Translator; High-Performance Tiled WMS and KML Web Server; Modeling of Radiative Transfer in Protostellar Disks; Composite Pulse Tube; Photometric Calibration of Consumer Video Cameras; Criterion for Identifying Vortices in High- Pressure Flows; Amplified Thermionic Cooling Using Arrays of Nanowires; Delamination-Indicating Thermal Barrier Coatings; Preventing Raman Lasing in High-Q WGM Resonators; Procedures for Tuning a Multiresonator Photonic Filter; Robust Mapping of Incoherent Fiber-Optic Bundles; Extended-Range Ultrarefractive 1D Photonic Crystal Prisms; Rapid Analysis of Mass Distribution of Radiation Shielding; Modeling Magnetic Properties in EZTB; Deep Space Network Antenna Logic Controller; Modeling Carbon and Hydrocarbon Molecular Structures in EZTB; BigView Image Viewing on Tiled Displays; and Imaging Sensor Flight and Test Equipment Software.

Source record↗

NASA Ares I Launch Vehicle First Stage Roll Control System Cold Flow Development Test Program Overview

The Ares I launch vehicle is the selected design, chosen to return humans to the moon, Mars, and beyond. It is configured in two inline stages: the First Stage is a Space Shuttle derived five-segment Solid Rocket Booster and the Upper Stage is powered by a Saturn V derived J-2X engine. During launch, roll control for the First Stage (FS) is handled by a dedicated Roll Control System (RoCS) located on the connecting Interstage. That system will provide the Ares I with the ability to counteract induced roll torque while any induced yaw or pitch moments are handled by vectoring of the booster nozzle. This paper provides an overview of NASA s Ares I FS RoCS cold flow development test program including detailed test objectives, types of tests run to meet those objectives, an overview of the results, and applicable lessons learned. The test article was built and tested at the NASA Marshall Space Flight Center in Huntsville, AL. The FS RoCS System Development Test Article (SDTA) is a full scale, flight representative water flow test article whose primary objective was to obtain fluid system performance data to evaluate integrated system level performance characteristics and verify analytical models. Development testing and model correlation was deemed necessary as there is little historical precedent for similar large flow, pulsing systems such as the FS RoCS. The cold flow development test program consisted of flight-similar tanks, pressure regulators, and thruster valves, as well as plumbing simulating flight geometries, combined with other facility grade components and structure. Orifices downstream of the thruster valves were used to simulate the pressure drop through the thrusters. Additional primary objectives of this test program were to: evaluate system surge pressure (waterhammer) characteristics due to thruster valve operation over a range of mission duty cycles at various feed system pressures, evaluate temperature transients and heat transfer in the pressurization system, including regulator blowdown and propellant ullage performance, measure system pressure drops for comparison to analysis of tubing and components, and validate system activation and re-activation procedures for the helium pressurant system. Secondary objectives included: validating system processes for loading, unloading, and purging, validating procedures and system response for multiple failure scenarios, including relief valve operation, and evaluating system performance for contingency scenarios. The test results of the cold flow development test program are essential in validating the performance and interaction of the Roll Control System and anchoring analysis tools and results to a Critical Design Review level of fidelity.

Butt, Adam↗

Pyrotechnic shock measurement and data analysis requirements

A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.

Albers, L.↗

Lightning induced currents in aircraft wiring using low level injection techniques

Various techniques were studied to predict the transient current induced into aircraft wiring bundles as a result of an aircraft lightning strike. A series of aircraft measurements were carried out together with a theoretical analysis using computer modeling. These tests were applied to various aircraft and also to specially constructed cylinders installed within coaxial return conductor systems. Low level swept frequency CW (carrier waves), low level transient and high level transient injection tests were applied to the aircraft and cylinders. Measurements were made to determine the transfer function between the aircraft drive current and the resulting skin currents and currents induced on the internal wiring. The full threat lightning induced transient currents were extrapolated from the low level data using Fourier transform techniques. The aircraft and cylinders used were constructed from both metallic and CFC (carbon fiber composite) materials. The results show the pulse stretching phenomenon which occurs for CFC materials due to the diffusion of the lightning current through carbon fiber materials. Transmission Line Matrix modeling techniques were used to compare theoretical and measured currents.

Stevens, E. G.↗

Design and test hardware for a solar array switching unit

This paper describes the control of a pulse width modulated (PWM) type sequential shunt switching unit (SSU) for spacecraft applications. It is found that the solar cell output capacitance has a significant impact on SSU design. Shorting of this cell capacitance by the PWM switch causes input current surges. These surges are minimized by the use of a series filter inductor. The system with a filter is analyzed for ripple and the control to output-voltage transfer function. Stable closed loop design considerations are discussed. The results are supported by modeling and measurements of loop gain and of closed-loop bus impedance on test hardware for NASA's 120 V Earth Observation System (EOS). The analysis and modeling are also applicable to NASA's 160 V Space Station power system.

Patil, A. R.↗

Analysis of the Range and Range Rate Tracking System

The "range and range rate"' (r(sub i) + r(sub i)) system in its very simplest form is described. In particular, the errors in position and velocity are treated using pessimistic values of the measured quantities r(sub i) and r(sub i). Thus, a realistic evaluation of tracking qualities can be made for different orbits over certain tracking stations. The range and range rate system briefly described in this paper is a high-precision tracking system. Knowledge of the uncertainty in position δ(sub xi) is important, but knowledge of the uncertainty of the velocity vector δ(sub xi) is of the utmost importance. Thus the use of coherent Doppler measurements to determine the velocity has a great advantage over any pulsed system and, in addition, permits extremely narrow frequency bandwidths (in the order of 10 to 100 cps) to be employed, reducing the power requirements considerably. The basis for using range r(sub i) and range rate r(sub i) only is the fact that r(sub i) and r(sub i) can be measured to very high precision, thus furnishing r and r with low errors. The nature of these errors is discussed.

Vonbun, F. O.↗

Characterizing the System Impulse Response Function from Photon-Counting LiDAR Data

NASA's Multiple Altimeter Beam Experimental LiDAR (MABEL) is an aircraft-based photon-counting laser altimeter designed as a simulator to test measurement techniques and algorithms for Advanced Topographic Laser Altimeter System (ATLAS), the sole instrument on NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission. By measuring the time of flight, pointing angle, and absolute position for individual photons, ICESat-2 provides detailed elevation measurements of earth's surface. Calculating accurate and precise elevations requires an understanding of how photons interact with surfaces, and characterization of the photon distribution after returning from surfaces. Neither MABEL nor ATLAS records the transmitted laser pulse shape, relying instead on aggregating several pulses worth of photons, often using histograms, to characterize the pulse shape. In this paper, we assess the limitations of using histograms and propose a more robust method to describe MABEL's system impulse-response function using an exponentially modified Gaussian distribution. We also provide standard error estimates for the arithmetic mean and standard deviation calculations, and for exponentially modified Gaussian parameters using a Monte Carlo sensitivity analysis. We apply this method to photon returns from a sea ice lead and from a dry salt lake bed as case studies for estimating the standard error associated with sample size for the arithmetic mean and standard deviation, and for the exponentially modified Gaussian parameters. We use these standard errors to calculate the minimum number of photons required to find both Gaussian and exponentially modified Gaussian distribution parameters within 3 cm of their parent population values.

photoncounting↗

3-D Surface Depression Profiling Using High Frequency Focused Air-Coupled Ultrasonic Pulses

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. This article shows quantitative surface topography profiles as obtained using only high-frequency focused air-coupled ultrasonic pulses. The profiles were obtained using a profiling system developed by NASA Glenn Research Center and Sonix, Inc (via a formal cooperative agreement). (The air transducers are available as off-the-shelf items from several companies.) The method is simple and reproducible because it relies mainly on knowledge and constancy of the sound velocity through the air. The air transducer is scanned across the surface and sends pulses to the sample surface where they are reflected back from the surface along the same path as the incident wave. Time-of-flight images of the sample surface are acquired and converted to depth/surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in air (V). The system has the ability to resolve surface depression variations as small as 25 microns, is useable over a 1.4 mm vertical depth range, and can profile large areas only limited by the scan limits of the particular ultrasonic system. (Best-case depth resolution is 0.25 microns which may be achievable with improved isolation from vibration and air currents.) The method using an optimized configuration is reasonably rapid and has all quantitative analysis facilities on-line including 2-D and 3-D visualization capability, extreme value filtering (for faulty data), and leveling capability. Air-coupled surface profilometry is applicable to plate-like and curved samples. In this article, results are shown for several proof-of-concept samples, plastic samples burned in microgravity on the STS-54 space shuttle mission, and a partially-coated cylindrical ceramic composite sample. Impressive results were obtained for all samples when compared with diamond-tip profiles and measurements from micrometers. The method is completely nondestructive, noninvasive, non-contact and does not require light-reflective surfaces.

Roth, Don J.↗

Analysis of the ''Range and Range Rate'' Tracking System

The "Range and Range Rate" (r(sub j) + r ̇(sub j)) System in its very simplest form is described. In particular, the errors in position and velocity are treated usingpessimistic values of the measured quantities r(sub j) and r ̇(sub j). Thus, a realistic evaluation of tracking qualities can be made for different orbits over certain tracking stations. The Range and Range Rate System briefly described in this report is a high precision tracking system. Knowledge of the uncertainty in position δ (sub x(sub i) is important, but knowledge of the uncertainty of the velocity vector δ (sub x(sub i) is of the utmost importance. Thus the use of coherent Doppler measurements to determine the velocity has a great advantage over any pulsed system and, in addition, permits extremely narrow frequency bands (in the order of 10 to 100 cps) to be employed, reducing the power requirements considerably. The basis for using range r(sub j) and range rate r ̇(sub j) only is the fact that r(sub j) and r ̇(sub j) can be measured to very high precision, thus furnishing r and r with low errors. The nature of these errors is discussed.

Tracking system↗

A comparison of lightning and nuclear electromagnetic pulse response of tactical shelters

The internal response (electromagnetic fields and cable responses) of tactical shelters is addressed. Tactical shelters are usually well-shielded systems. Apart from penetrations by signal and power lines, the main leakage paths to the interior are via seams and the environment control unit (ECU) honeycomb filter. The time domain in three-dimensional finite-difference technique is employed to determine the external and internal coupling to a shelter excited by nuclear electromagnetic pulses (NEMP) and attached lightning. The responses of interest are the internal electromagnetic fields and the voltage, current, power, and energy coupled to internal cables. Leakage through the seams and ECU filter is accomplished by their transfer impedances which relate internal electric fields to external current densities. Transfer impedances which were experimentally measured are used in the analysis. The internal numerical results are favorably compared to actual shelter test data under simulated NEMP illumination.

Perala, R. A.↗