Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient bidirectional quantum frequency conversion between telecom and visible bands using adaptively phase-matched III-V nanophotonic waveguides

Quantum frequency conversion (QFC) is essential for interfacing quantum systems operating at different wavelengths and for realizing scalable quantum networks. Despite extensive progress, achieving QFC with simultaneous high efficiency, low pump power, minimal noise, broad bandwidth, and pump-wavelength flexibility remains challenging. Here, we demonstrate efficient, low-noise, and bidirectional QFC between the telecom (1550-nm) and visible (780-nm) bands using unpoled indium gallium phosphide (InGaP) χ (2) nanophotonic waveguides, eliminating the need for a long-wavelength pump. Leveraging the large nonlinear susceptibility of InGaP together with adaptive phase-matching control, we obtain 27% (55%) internal efficiency in a 6-mm (2.5-mm)-long waveguide with a low pump power of 20 mW (50 mW) and a noise flux spectral density of 10 −4 counts per second per hertz at signal–pump detuning of 20 nm. These results mark a significant advance in integrated nonlinear photonics for high-performance QFC, facilitating the development of versatile and scalable quantum networks.

Hu, Jierui [Univ. of Illinois at Urbana-Champaign,↗

Efficiency of Nd laser materials with laser diode pumping

For pulsed laser-diode-pumped lasers, where efficiency is the most important issue, the choice of the Nd laser material makes a significant difference. The absorption efficiency, storage efficiency, and extraction efficiency for Nd:YAG, Nd:YLF, Nd:GSGG, Nd:BEL, Nd:YVO4, and Nd:glass are calculated. The materials are then compared under the assumption of equal quantum efficiency and damage threshold. Nd:YLF is found to be the best candidate for the application discussed here.

Barnes, Norman P.↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An efficient electron-beam-pumped semiconductor laser for the green spectral range based on II-VI multilayer nanostructures

Emission characteristics of an electron-beam-pumped Cd(Zn)Se/ZnMgSSe semiconductor laser are studied. The laser's active region consists of a set of ten equidistant ZnSe quantum wells containing fractional-monolayer CdSe quantum-dot inserts and a waveguide formed by a short-period superlattice with the net thickness of {approx}0.65 {mu}m. Lasing occurs at room temperature at a wavelength of 542 nm. Pulsed power as high as 12 W per cavity face and an unprecedentedly high efficiency of {approx}8.5% are attained for the electron-beam energy of 23 keV.

36 MATERIALS SCIENCE↗

Theoretical, numerical and experimental investigation of centrifugal pumps in reverse operation

When a pump works as a turbine, its hydraulic behavior will be changed. Several methods have been developed to predict the best efficiency of pumps running as turbines but their results are not in good coincidence with experimental data for all pumps. Therefore, study and investigation of hydraulic behavior of pumps in reverse operation can be useful. In this study, the best efficiency point of an industrial centrifugal pump running as turbine was achieved using a theoretical analysis. This method tries to estimate hydraulic components of reverse (turbine) mode using direct (pump) mode. In the next step, the pump was simulated in direct and reverse modes by computational fluid dynamics. 3D full Navier-Stokes equations were solved using FineTurbo V.7 flow solver. Using numerical results, complete characteristic curves of the pump in direct and reverse modes were obtained. For experimental verification of theoretical and numerical results, the pump was tested as a turbine in a test rig. All required parameters were measured to achieve complete characteristic curves of the reverse pump. The theoretical and numerical results were compared with experimental data and some other methods. (author)

13 HYDRO ENERGY↗

Energy Efficient, Cost-Effective Power and Co-Generation Technologies: Techno-Environmental Analysis

Development of energy solutions for addressing grid resiliency and energy efficiency while lowering greenhouse gas emissions is critical in today’s energy scenario. Chemical energy provides on demand power. Cogeneration technologies offer numerous benefits in meeting the growing energy demand while lowering the impact on environment. Utilization of waste heat from prime movers in conjunction with energy efficient heat pumps and renewable photovoltaics is an attractive approach. Efficient utilization of available resources to support current and future building energy needs targeting grid resiliency, energy and environmental security via co-generation approaches is the focus of this study. A detailed techno-environmental analysis of hybrid system configurations consisting of conventional and emerging technologies utilizing natural gas, electric grid, and renewable power resources along with heat recovery systems and heat pump technologies are analyzed and presented. The key objective is to present integrated system configurations and thermodynamic analysis of various co-generation systems suitable for providing building energy. Design solutions targeting low carbon footprint and high energy efficiency are presented.

Cheekatamarla, Praveen↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

Efficient diode-side-pumped Nd:YVO{sub 4} slab laser in different generation regimes

A diode-side-pumped Nd:YVO{sub 4} slab laser with the grazing-incidence bounce geometry of the cavity is studied experimentally. Upon continuous pumping different lasing regimes are realised, namely, cw, passive and active Q-switching and passive mode-locking. The resonator parameters are optimised to achieve the maximum cw output power ({approx}17 W) and high-quality beam (M{sup 2} {approx} 1.3). (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient combining of ion pumps and getter-palladium thin films

Nonevaporable getters (NEGs) have been extensively studied in the last several years for their sorption properties toward many gases. In particular, an innovative alloy as a thin film by magnetron sputtering was developed and characterized at the European Organization for Nuclear Research. It is composed of Ti-Zr-V and protected by an overlayer of palladium (Pd), according to a technology for which the authors got the licence. NEG-Pd thin films used in combination with ion getter pumps is a simple, easy way to handle pumping devices for ultrahigh and extremely high vacuum applications. To show how to apply this coating technology to the internal surface of different types of ion pumps, the authors carried out several tests on pumps of various shapes, sizes (in terms of nominal pumping speed), and types (diode, noble diode, and triode). Special care was taken during the thermal cycle of baking and activation of the pumps to preserve the internal film from sources of contamination and/or from the sputtering of the titanium cathodes of the pump. Some important remarks will be made about the most appropriate conditions of pressure and temperature. The performance of the NEG-Pd-coated ion pumps was evaluated in terms of ultimate pressure and hydrogen pumping speed. The contribution of the thin film is particularly relevant for the pumping of this gas, due to its high sticking factor on palladium and the great sorption capacity of the underlying getter. Finally, the possibility of further improvement by substituting palladium with other Pd-based alloys will also be evaluated.

36 MATERIALS SCIENCE↗

High-efficiency Commercial Cold Climate Heat Pump

United Technologies Research Center (UTRC) proposed in 2012 to design, develop and demonstrate an air-source 10TR high-efficiency commercial cold climate heat pump (CCCHP). The proposed heat pump would be scalable beyond 40TR, cost effective with a simple payback of < 3 years upon commercialization and would reduce annual electricity use for building space heating in cold climates by at least 20%. This would represent an annual savings of $2.3 billion and a 20% displacement of total greenhouse gases generated upon full commercialization. The primary objective was to develop a highly integrated system that shall meet or exceed DOE capacity and efficiency targets at key conditions and is scalable, cost-effective and simple relative to the state-of-the-art. Specifically, the goal of the project was to design, develop and demonstrate a CCCHP that exceeds DOE capacity degradation requirements at +17F and -13F conditions (0 and <15% degradation vs. 10 and 25% DOE requirements, respectively) while meeting or exceeding DOE capacity and system efficiency requirements at all other conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient lasing in diode-pumped Yb{sup 3+}:CaF{sub 2}-SrF{sub 2} solid-solution single crystals

Single crystals of solid solutions of a high optical quality are grown in the concentration vicinity of the saddle point of the ternary CaF{sub 2}-SrF{sub 2}-YbF{sub 3} system. Efficient lasing with a small Stokes shift (at 1025 nm) was obtained in 980-nm diode-pumped single crystals. The total lasing efficiency (with respect to the absorbed average pump power) was 59% and the slope efficiency was 83%. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

36 MATERIALS SCIENCE↗