Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tank 27 Solids Disturbance Testing Using M-Star for the Impact of CSMP Usage on Blend Tank Mixing Effectiveness

Savannah River Mission Completion (SRMC) plans to operate Tank 27as a blend tank for future waste disposal operations. It is desirable to avoid additional worker exposure by using the planned commercial submersible mixing pump (CSMP) installations in Risers B2 and B4 to function as the blend pumps for prolonged blend tank operations. The purpose of this task is to evaluate the impacts to mixing across a range of pump installation heights from 1 to 201 inches above the tank floor. The CSMPs shall maintain adequate blending within a 24 hour maximum timeframe and an adequate nozzle discharge velocity as outlined in U-ESR-G-00030, using the specifications of the planned CSMPs listed in PO SRRA149971 and M-DS-G-00081. Specifications include: maximum pump diameter of D=22.5 in., dual nozzles placed tangentially opposed with nominal inside diameter of 2 in., total flow range (both nozzles combined) of 500 to 1950 GPM and maximum RPM of 1800. Tank 27 is expected to have a fill height maximum of 360". This analysis began by using results from the 2010 testing and applying them to the Tank 27 design to calculate a mixing time as a function of pump flow rate. These results were modified to account for the higher liquid level in Tank 27. Once the liquid level was increased to 360 inches, the results were modified to account for a higher viscosity in Tank 27 than in the testing. Once the viscosity was increased, the effect of changing pump elevation was applied to calculations of the mixing time in Tank 27. Finally, the uncertainty from the testing was included in the analysis to recommend a blend time as a function of pump flow rate and elevation. The conclusion from this study is that the particles in tank 27 will be suspended at both the 600 and 900 gpm flow rates. Only particles above 90 micron will not be suspended in significant amounts when the flow rate is 600 gpm. At 900 gpm even 100 micron particles were thoroughly suspended in the tank. From the series of simulations it has been concluded that it will not be possible to mix tank 27 at the proposed fluid flow rates and not suspend the solid particles at the bottom of the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Survival estimates across five life stages of redfin ( Perca fluviatilis ) exposed to simulated pumped-storage hydropower stressors

The global prevalence of pumped-storage hydropower (PSH) is expected to grow exponentially as countries transition to renewable energy sources. Compared to conventional hydropower, little is currently known regarding PSH impacts on aquatic biota. This study estimated the survival of five life stages (egg, two larval stages, juvenile and adult) of redfin (European) perch (Perca fluviatilis) following passage through a PSH facility during the pumping phase. This was achieved by simulating the individual stressors expected to occur during passage through a 2000-MW PSH facility using laboratory-simulated (shear strain and extreme compression) and modelling (blade strike, BS) approaches. Our results indicate that redfin could survive the shear, pressure and BS stressors expected within the PSH facility, but impacts varied among life stages. Juvenile survival was >70% across all shear strain rates, while the survival of eggs and larvae declined markedly as strain rate increased. All life stages had high survival when exposed to rapid compression and BS. The high survival of redfin to the stressors tested suggests the PSH facility could facilitate the passage of redfin during the pumping phase from the lower to the higher elevation reservoir. This outcome would be welcomed in situations where the species is native, but could have adverse implications for the conservation of native biota where the species is considered a pest.

59 BASIC BIOLOGICAL SCIENCES↗

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Stimulation Pressure and Circulation Data April, 2024

This dataset consists of all of the pressure pumping data for Utah FORGE Well16A78-32 fracturing stages, Well 16B78-32 fracturing stages, and a 9-hour circulation test which took place after all of the frac plugs were drilled out. Fracturing in the wells took place in stages from April 3rd to April 17th, while the circulation test occurred on April 27th, 2024. Data is in excel files, with ReadMe files for each of the .zip folders that detail what data is available. Also attached here is wellhead pressure data from Pason that is referred to in the ReadMe files.

15 GEOTHERMAL ENERGY↗

Benchmark Modeling and Simulation of the FFTF LOFWOS Test #13 Using SAM

The Fast Flux Test Facility (FFTF) was a 400 MW thermal powered, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. In July 1986, a series of unprotected Loss of Flow Without Scram (LOFWOS) transients were performed in FFTF as part of the Passive Safety Testing (PST) program. The LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors left off, has been chosen as a benchmark case by IAEA to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of sodium fast reactor passive safety in an IAEA Coordinated Research Project (CRP), launched in October 2018. The System Analysis Module (SAM) is an advanced and modern system analysis tool under development at Argonne National Laboratory for advanced non-LWR safety analysis. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. To participate the IAEA CRP and enhance the SAM validation base for advanced reactor transient safety analysis, benchmark simulations of the FFTF LOFWOS Test #13 are performed using the SAM code. In this first phase of the validation effort, the thermal-hydraulic behavior of the reactor system is the focus and the reactor kinetics is not considered in the SAM FFTF model. Instead, the results of Argonne’s neutronics calculations are directly used, including the power shape of the active core region and the power history during the transient. The simulation results of FFTF at steady state agreed well with the measured data from the test. During the transient, reasonably good agreement were also obtained. Future work to improve the model will focus on introducing the reactivity predictions into the model, as well as better understanding or resolving the current discrepancies with the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of a multi-kW, large-aperture gas-cooled Faraday rotator

We characterize a large-aperture gas-cooled Faraday rotator (FR) designed to mitigate stress-induced depolarization in high-energy, high-power laser systems. The rotator, based on ceramic TGG, was tested using a 150 mW probe beam at 1047 nm and a pump beam at 1070 nm. Compensating for the birefringence induced by the surrogate depolarization plate at 3.3 kW of effective pump power, the rotator reduces the spatially in-homogeneous depolarized light containing linear, circular, and elliptical polarization states to nearly linear with approximately 0.8% (or −21 dB) of residual depolarized energy. The FR demonstrated effective depolarization compensation across its 58×58 mm 2 aperture.

47 OTHER INSTRUMENTATION↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Smart technologies enable homes to be efficient and interactive with the grid

Oak Ridge National Laboratory researchers compare two different approaches to test how advanced, energy-efficient building technologies such as smart thermostats, heat pump water heaters, and advanced heat pump HVAC (heating, ventilation and air conditioning) can be optimized within a home and connected at a neighborhood-scale load to a community microgrid in the Alabama Power Smart Neighborhood located in Hoover. Working with Southern Company and Alabama Power, ORNL researchers are pioneering that future where smart homes and smart neighborhoods can benefit both homeowners and utilities, by reducing energy consumption by 44% and peak demand by 34%.This project is one of two neighborhoods in the U.S Department of Energy’s (DOE’s) Connected Neighborhood project, supported by Building Technologies Office , where ORNL researchers leverages DOE investment in micro-grids and responsive, flexible building loads research to improve grid reliability – a goal of DOE’s Grid-interactive Efficient Buildings (GEB) Initiative. Researchers control the neighborhood and microgrid to enable utilities achieve their desired load and cost profiles while ensuring the comfort of homeowners in the Smart Neighborhood. This transactive control approach maximizes the utilization of technical resources of the microgrid and controllable loads, while reducing costs for both the homeowners and Alabama Power. These tests partially seek to determine a more precise range of tolerance with respect to occupant comfort as researchers work to facilitate customer acceptance and perception of new building technologies that enable energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

HTS Dipole Magnet Model for the Persistent Current Operation

Recent advances in the fabrication of high-temperature superconducting (HTS) coils allow the design of superconducting accelerator magnets that work in a persistent current mode. Many various, rather low-field magnets in particle accelerators operate in the DC current mode. Fermilab designed, fabricated, and tested an HTS dipole magnet model that has 20-mm air gap and a magnetic field up to 0.5 T. The magnet has a primary copper coil that for a short period pumps the energy in the short-circuited secondary HTS coil. Here, the current paper presents the design, fabrication, and testing of this magnet at liquid-nitrogen temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗