Modeling filtered building effluent stack sampling points for qualification criteria
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not provided.
Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.
Novel disruption prevention solutions spanning a range of control regimes are being developed and tested on DIII-D to enable ITER success. First, a new real-time control algorithm has been developed and tested for regulating nearness to stability limits and maintaining safety-margins. Its first application has been for reliable prevention of vertical displacement events (VDEs) by adjusting plasma elongation (κ) and the inner-gap between the plasma and inner-wall in response to real- time open-loop VDE growth rate (γ) estimators. VDEs were robustly prevented up to average open-loop growth rates of 800 rad/s with initial tunings, with only applying shape modification when near safety limits. Second, the disruption risk during fast, emergency shutdown after large tearing and locked modes can be significantly improved by transitioning to a limited topology during shutdown. More than 50% of emergency limited shutdowns after locked modes reach a final normalized current I_N < 0.3 before terminating, scaling to the 3 MA ITER requirement. Furthermore, this is in contrast to diverted shutdowns, the majority of which disrupt at I_N > 0.8. Despite improvements, these results highlight the critical importance of early prevention. Third, a novel emergency shut down method has been developed which excites instabilities to form a warm, helical core post-thermal quench. The current quench extends to ~100ms and avoids VDEs and runaway electron generation. Novel real-time machine learning disruption prediction has been integrated with the DIII-D proximity controller, and a real- time compatible multi-mode MHD spectroscopy technique has been developed. Results presented here were enabled by a focused effort, the Disruption Free Protocol, in DIII-D’s 2019-20 campaign to complement disruption prevention experiments with a large piggy-back program. In addition to testing novel techniques, it is estimated to have helped avoid 32 potential disruptions in piggyback operations with rapid, early shutdowns after large rotating n=1 or locked modes.
Not Available
A joint European Canadian Chinese development of a supercritical water-cooled small modular reactor (SCW-SMR) technology is in progress since September 2020 in the framework of a Horizon 2020 project called ECC-SMART. As a main purpose of the project, proper estimates of energy deposition and its spatial distribution are prerequisites for the accurate analysis of safety related parameters of the SCW-SMR concept under development. A supercritical water reactor fuel computational benchmark model, provided by Canadian Nuclear Laboratories, was applied for detailed comparison of different energy deposition calculation options available in the Serpent 2 Monte Carlo code. The effect of energy deposition options on the normalization of the results as well as on the spatial distribution of the energy deposition are discussed. Consistent energy deposition calculation methods are presented between three Monte Carlo codes, viz., Serpent 2, MCNP6 and OpenMC. Although resource-intensive, the use of the coupled neutron-photon transport mode of Serpent 2 is recommended for accurate spatial and quantitative characterization of energy deposition in the SCW-SMR fuel assemblies, accounting for both neutron and photon heating of all the materials. (authors)
Explore the source record for details and available documents.
The Proton Power Upgrade project at Oak Ridge National Lab’s Spallation Neutron Source (SNS PPU) currently being constructed will double the proton beam power from 1.4 to 2.8 MW by adding 7 additional cryomodules, each contains four six-cell high beta (\beta = 0.81) superconducting radio frequency cavities. The cavities were built by Research Instruments, Germany, with all the cavity processing done at the vendor site, including electropolishing as the final active chemistry step. All 28 cavities needed for 7 cryomodules were delivered to Jefferson Lab, ready to be tested. The cryogenic RF qualifications and helium vessel welding were done at Jefferson Lab. The performance largely exceed the requirements, and greatly exceeded the performance of the original SNS cavity production series. Here, we present the summary of RF test on production cavities to this date.
High-beta (HB) and low-beta (LB) 650 MHz cryomodules are key components of the Proton Improvement Plan II (PIP-II) project. In this contribution we present the results of several 5-cell HB650 cavities that have been processed and tested with the purpose of qualifying them for the prototype cryomodule assembly, which will take place later this year. We also present the first results obtained in LB650 single-cell cavities process optimization. Taking advantage of their very similar geometry, we are also analyzing the effect of different surface treatments in FRIB’s 5-cell medium-beta 644MHz cavities. Cavities processed with N-doping and mid-T baking showed very promising results in term of both Q-factors and accelerating gradient for these low-beta structures.
Design of the high beta 650 MHz prototype cryomodule for PIP-II is currently undergoing at Fermilab. The cryomodule includes six 5-cell elliptical SRF cavities with accelerating voltage up to 20 MV and low heat dissipation (Q₀ > 3.3 · 10^{z}EhNZeHn). Characterization of performance of fully integrated jacketed cavities with high power coupler and tuner is crucial for the project. Such a characterization of jacketed cavity requires a horizontal test cryostat. The Fermilab Spoke Test Cryostat (STC) has been upgraded to accommodate testing of 650 MHz cavities. Commissioning of upgraded STC has been reported at SRF’19 conference. In this paper we present results of testing of the prototype HB650 cavity in upgraded STC facility. We characterize cavity performance and qualify it for the prototype HB650 cryomodule assembly.
Acceptance testing of the LCLS-II-HE production cavities is approximately 65% complete. In this report, we present details of the test results, including summaries of the quench fields, intrinsic quality factors, and experience with field emission. We also offer an outlook on the remaining tests to be performed.
The purpose of the deflagration-to-detonation test is to demonstrate that an IHE material will not undergo deflagration-to-detonation transition (DDT) under stockpile relevant conditions of scale, confinement, and material condition. Inherent in this test design is the assumption that ignition does occur, with onset of deflagration. The test design will incorporate large margins and replicates to account for the stochastic nature of DDT events.
This DOE Fossil Energy project, FEAA117, addressed materials issues relevant to qualifying and deploying a Ni-base alloy for a new application in an advanced ultra-supercritical coal-fired boiler. The goal was the deployment of Haynes International alloy Haynes® 282® for applications in superheaters, reheaters, and steam delivery pipes, by completing base metal, cross-weld and all-weld metal mechanical testing needed for an ASME Boiler and Pressure Vessel Code Case and the associated microstructural analyses needed for assurance of boiler-relevant lifetimes. The alloy also is of interest for other applications including supercritical CO₂ power generation cycles. Tensile testing was completed from 20°-927°C on the three base metal alloy 282 heats, two sets of cross-weld specimens and all weld metal specimens. A total of 148 creep tests with over 565,000 h of cumulative testing was completed on base metal, cross-weld and all weld metal specimens. This project was performed with cost share from Haynes International.
Through this project, we sought to gather a body of customer data that either proved or disproved our assumption that metrics other than FICO can and should be used to qualify customers for community solar. Using customer data on income, FICO scores, and utility/rent/cell phone repayment history, we developed an alternative metric in order to test in the market at a small scale whether new qualifying metrics could open the shared solar market up to millions of additional households. We demonstrate that the EnergyScore is both more accurate in qualifying customers that will not default, and more inclusive in qualifying low to moderate income households. We are now in the process of utilizing the EnergyScore in a number of pilot projects, building a robust dataset of customer churn and default, and subsequently disseminating this data to more traditional and larger scale financiers and solar developer partners to change the way potential customers are qualified.
Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).
When Solstice began working in the community solar industry, it quickly became clear that there was a wide disparity along race and class lines in terms of what kind of household traditional solar offerings benefited. Solstice is an organization that aligns itself to the principles of a Just Transition, or the concept that a transition to a green economy should benefit and prioritize historically marginalized groups of people. Given that low-income communities are disproportionately burdened by our current polluting fossil fuel economy, Solstice set out to investigate the root causes of the exclusion of low to moderate income (LMI) households in the community solar market. As we worked more and more with financiers, developers, and LMI households, we recognized that significant barriers to entry in a developer-owned project were credit threshold requirements. A FICO score of 750 and higher discriminates against LMI households that are not financially stable enough to take on multiple lines of credit (or who may not have been deemed credit worthy enough to access a line of credit) yet who may have been reliable utility customers. As Solstice began looking further into preliminary data and speaking to community-based organizations (CBOs) that serve LMI households, we found our hypothesis to be worth investigating; there was indeed a subset of LMI households with poor FICO scores (or no FICO score at all) that had perfect bill payment history. Though initially Solstice was intent on gathering a body of data to prove or disprove this hypothesis, we were also concerned that all this proof of a financially stable and reliable customer was not being incorporated into FICO, and wondered if such a score would be possible. After preliminary research into the existence of alternative scores, Solstice realized that many mission-driven lending institutions rely on alternative metrics that are formulated for their specific industry. However, we also realized that community solar did not have an alternative credit underwriting mechanism, though there was great need from solar financiers for one. We anticipated that the creation of an EnergyScore would contribute to financiers’ need to qualify more people, as these entities are desperately looking for ways to lower the cost of customer acquisition. FICO turns away nearly 50% of potential customers (according to our own acquisition experience), and much of the community solar industry is realizing that FICO is not the perfect qualifying mechanism. Additionally, with a grounding in energy justice, just transitions, and climate justice, Solstice recognizes the need for a solution that addresses a more urgent need for LMI households to access renewable energy savings and relieve energy burdens. With funding from the Department of Energy, we gathered the data necessary to build the EnergyScore, reached out to mission-driven developers willing to test the metric, and secured several demonstration projects to pilot the EnergyScore. After acquiring customers for these demo projects using the EnergyScore, we will be continuously collecting customer payment behavior data. Though it goes beyond the scope of this project, we plan to disseminate this de-identified data with the wider community solar industry, which includes not only financiers and developers, but other mission-driven nonprofits, solar cooperatives, community-based organizations, environmental justice activists, and academics. While we intend to disprove the notion that LMI households cannot be included in projects without acutely increasing the risk to project finances, we also hope the data can be used to negotiate better pricing of systems and terms of ownership for community groups seeking to build inclusive projects.