Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Definition of air quality measurements for monitoring space shuttle launches

A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

Thorpe, R. D.↗

Air Quality Satellite Monitoring by TROPOMI on Sentinel-5P

The recently launched Sentinel satellite mission, the Sentinel-5 Precursor (Sentinel-5P), is one of the European Space Agency's (ESA) new mission family – Sentinels. The sole payload on Sentinel-5P is the TROPOspheric Monitoring Instrument (TROPOMI), a nadir-viewing 108⁰ field-of-view push-broom grating hyperspectral spectrometer, covering the wavelengths of ultraviolet-visible (270 nm - 495 nm), near infrared (675 nm - 775 nm), and shortwave infrared (2305 nm - 2385 nm). Sentinel-5P is the first of the Atmospheric Composition Sentinels, and is providing measurements of atmospheric chemistry, aerosols, and clouds at high spatial, temporal, and spectral resolution. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) supports over a thousand data collections in the focus areas of Atmospheric Composition, Water & Energy Cycles, and Climate Variability. Sentinel-5P TROPOMI Level-1B (L1B) and Level-2 (L2) products are curated at the GES DISC. Sentinel-5P data are provided by the European Union and the European Space Agency (ESA) through an agreement between ESA and NASA. Through its convenient and enhanced tools/services, such as OPeNDAP and L2 Subsetting, GES DISC offers the air quality remote sensing user community facile solutions for using complex Earth science data and applications. This presentation will demonstrate up-to-date TROPOMI products including EarthView (EV) radiance, solar irradiance, Aerosol Index, Carbon Monoxide, Total column Ozone, Nitrogen Dioxide, and cloud, as well as easy ways to access, visualize and subset TROPOMI data.

TROPOMI↗

Monitoring water quality in the lower Kansas River using remote sensing

Abstract We demonstrate how to combine remote sensing data from satellite imagery (Sentinel‐2) with in situ water quality gauging (USGS Super Gages and the Gybe hyperspectral radiometer) to create spatially dense maps of water quality parameters (chlorophyll‐a concentration, turbidity, and nitrate plus nitrite concentration) along the lower Kansas River. The water quality maps are created using locally tuned models of the target water quality parameters, and this study describes the steps used to design, calibrate, and validate the empirical correlations. Water quality parameters such as chlorophyll‐a concentration are correlated with well‐studied absorption and scattering features in the visible spectrum (roughly 400–700 nm). Nutrients (such as nitrate plus nitrite concentration) lack strong absorption features in the visible spectrum, and in those cases we describe a novel surrogate data modeling approach that identifies overlapping water parcels between the in situ gauging and the remote sensing imagery. Measurements from the overlapping water parcels yield excellent correlations () for the target water quality parameters for limited windows of time (or limited sections of river reaches). Examples are provided illustrating how the water quality maps can be used to track river inputs from ungauged sources (such as creeks), or reveal the mixing patterns at the confluences.

Tufillaro, Nicholas↗

Biological indicators for monitoring water quality of MTF canals system

Biological models, diversity indexes, were developed to predict environmental effects of NASA's Mississippi test facility (MTF) chemical operations on canal systems in the area. To predict the effects on local streams, a physical model of unpolluted streams was established. The model is fed by artesian well water free of background levels of pollutants. The species diversity and biota composition of unpolluted MTF stream was determined; resulting information will be used to form baseline data for future comparisons. Biological modeling was accomplished by adding controlled quantities or kinds of chemical pollutants and evaluating the effects of these chemicals on the biological life of the stream.

Sethi, S. L.↗

Classifying and monitoring water quality by use of satellite imagery

A technique in which LANDSAT measurements from very clear lakes are subtracted from measurements from other lakes in order to remove atmospheric and surface noise effects to obtain a residual signal dependent only on the material suspended in the water is described. This residual signal is used by the Multispectral Data Analysis System as a basis for producing color categorized imagery showing lakes by type and concentration of suspended material. Several hundred lakes in the Madison and Spooner, Wisconsin area were categorized for tannin or non-tannin waters and for the degree of algae, silt, weeds, and bottom effects.

Scherz, J. P.↗

Classifying and monitoring water quality by use of satellite imagery

A technique is developed to eliminate the atmosphere and surface noise effects on Landsat signals of water bodies by manipulating the total signal from Landsat in such a way that only the volume reflectance is left as a residual. With the Landsat signal from a lake and the known volume reflectance for its clear water it is possible to eliminate the surface and atmospheric effects and have residual signals that are indicative only of the type and concentration of the material in other lakes. Laboratory values are more precise than field values because in the field one must contend with indirect skylight and wave action which can be removed in the laboratory. The volume reflectance of distilled water or a very clear lake approaching distilled water was determined in the laboratory by the use of the Bendix radiant power measuring instrument. The Bendix multispectral data analysis system provided a color categorized image of several hundred lakes in a Wisconsin area. These lakes were categorized for tannin and nontannin waters and for the degrees of algae, silt, weeds, and bottom effects present.

Scherz, J. P.↗

Testing Evaluation of the Electrochemical Organic Content Analyzer

The breadboard electrochemical organic content analyzer was evalauted for aerospace applications. An awareness of the disadvantages of expendables in some systems resulted in an effort to investigate ways of reducing the consumption of the analyzer's electrolyte from the rate of 5.17 kg/30 days. It was found that the electrochemical organic content analyzer can result in an organic monitor in the water quality monitor having a range of 0.1 to 100 mg/1 total organic carbon for a large number of common organic solutes. In a flight version it is anticipated the analyzer would occupy .0002 cu m, weigh 1.4 kg, and require 10 W or less of power. With the optimum method of injecting electrolyte into the sample (saturation of the sample with a salt) it would expend only 0.04 kg of electrolyte during 30 days of continuous operation.

Davenport, R. J.↗

Evaluation of available analytical techniques for monitoring the quality of space station potable water

To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

Geer, Richard D.↗

Telemetry Metrics: Monitoring Data Quality in the Spacecraft Ground Data System

During the launch of Mars Odyssey, ground data system (GDS) engineers experienced a glitch in the ground data system that caused us to re-evaluate how we looked at spacecraft telemetry, particularly during the spacecraft development period and for critical spacecraft events in flight. Spacecraft telemetry told the subsystem and instrument engineers about the health and status of the spacecraft, but there was surprisingly little information about how well the ground data system was doing in getting information from the spacecraft to the engineers.The problem for the Mars Odyssey launch was with a single channel not updating as often as expected. Spacecraft engineers considered calling off the Launch but eventually decided that this particular channel did not provide information that was crucial for launch. It was only after the post launch acquisition of the Odyssey signal that ground data system engineers heard there had been a concern about the channel....

Mars↗

Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

Wallace, William T.↗

Nanowire growth for sensor arrays

A nanowire-based sensor for in-situ gas and biochemical sensing including spacecraft safety monitoring, emission monitoring, air and water quality monitoring, and fire detection are designed.

Vasquez, Richard↗