Search NASASearch

SEARCH · Search NASA

Results for “quantum correlations in quantum information”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,795 records · Page 10

Interaction of magnetic fields with spinons in a fractionalized state

The 4d-electron trimer lattice Ba₄Nb₁₋ₓRu₃₊ₓO₁₂ exhibits either a quantum spin liquid (QSL) or a heavy-fermion strange metal (HFSM) phase, depending on Nb content. In the QSL state, itinerant spinons act as effective heat carriers, enhancing thermal conductivity. Strikingly, applying a magnetic field up to 14 T causes an abrupt, up-to-5000% increase in heat capacity below 150 mK, disrupting the linear temperature dependence typical of both phases. Meanwhile, AC susceptibility and electrical resistivity remain nearly unchanged, while thermal conductivity drops by up to 40% below 4 K. These results suggest spinons, despite being charge-neutral, are highly sensitive to magnetic fields at low temperatures. We propose that the magnetic field could induce Anderson localization of spinons, creating emergent non-magnetic two-level systems responsible for the Schottky-like anomaly in heat capacity. These findings point to a previously unexplored regime of spinon dynamics, potentially governed by field-induced localization and distinct from conventional magnetic or transport signatures.

Condensed-matter physics

Manufacturing Research in Support of Saturn V

Research achievements applicable to the production of Saturn V components a r e described in this report. Leakage at the mechanical connections in high-pressure lines has been minimized or eliminated through the use of precisely flared tubes. Flaring to close tolerance is done with a n orbital flaring adapter, and the forming operation is precisely controlled with an electronic control console. A technique of “aging” or heat-treatment hardening of aluminum materials has been used to form cylindrical-tank segments and double-contoured gore segments precisely, and to remove weld distortions). The control of weld porosity has been improved as a result of research which demonstrated the close correlation between electrical energy input per inch of weld and weld porosity and metallurgical quality. Based on this information, the gas metallic arc method has been used successfully for two-pass welding, and thinner gage aluminum has been welded (LOX tunnel to fuel bulkhead) with an MSFC designed gas metallic arc unit.

COMPOSITE MATERIAL

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen

Twist Engineering of Anisotropic Excitonic and Optical Properties of a Two-Dimensional Magnetic Semiconductor

Two-dimensional (2D) van der Waals (vdW) magnetic semiconductors are a new class of quantum materials for studying the emergent physics of excitons and spins in the 2D limit. Twist engineering provides a powerful tool to manipulate the fundamental properties of 2D vdW materials. Here, in this work, we show that twist engineering of the anisotropic ferromagnetic monolayer semiconductor CrSBr leads to bilayer magnetic semiconductors with continuously tunable magnetic moment, dielectric anisotropy, exciton energy, and linear dichroism. We furthermore provide a model for exciton energy in the media with tunable anisotropy. These results advance fundamental studies of 2D vdW materials and open doors to applications to nano-optics, twistronics, and spintronics.

36 MATERIALS SCIENCE

Intrinsic even-odd thickness-driven anomalous Hall effect in epitaxial MnBi2⁢Te4 thin films

We demonstrate precise control of magnetism in MnBi2⁢Te4 thin films through careful synthesis by molecular beam epitaxy, achieving minimal defects and accurate layer thickness control. By optimizing Mn-Bi-Te ratios and growth temperatures, we minimize detrimental self-doping effects and accurately target integer-layer films. X-ray diffraction and reflectivity provide quantitative measures of film quality and thickness. When these macroscale probes of structure and thickness are integrated with magnetotransport measurements, a striking even-odd layer dependence of the anomalous Hall effect is revealed. Odd-layer films exhibit a large hysteresis up to the Néel temperature (∼25K), consistent with noncompensated antiferromagnetism, while even-layer films show minimal response, as expected for an antiferromagnet. The sign of the anomalous Hall effect exhibits a sign reversal for intrinsic magnetism versus magnetism associated with defects. This work identifies critical factors for inducing pure, noncompensated ferromagnetism and reveals the characteristics of the intrinsic anomalous Hall effect in MnBi2⁢Te4, which together is a step toward realizing the zero-field quantum anomalous Hall effect in topological materials.

Mallick, Deb [ORNL] (ORCID:000900005806411X)

Microgravity Game Changers: Recent Accomplishments of Microgravity Assisted Materials Experiments on the ISS

This paper discusses important new materials, devices and technology produced in low-Earth orbit (LEO) that have been developed with funding from NASA’s In Space Production Applications (InSPA) Portfolio. In coordination with the International Space Station (ISS) National Laboratory, InSPA supports innovative small businesses and other research & development organizations to develop microgravity-assisted applications that make significant impacts in a wide variety of industries on Earth. These technology development efforts are using the microgravity of orbital space to overcome gravity-induced defects on Earth to create high-value products for terrestrial markets in the areas of semiconductors, pharmaceuticals, and communications. Through 24/7/365 operation on ISS for 25 years, coupled with commercial space transportation and services to, in, and from orbit, the microgravity environment has enabled pioneering science and significant commercial applications, including novel medical advances. World-leading researchers, innovators, and space payload developers provide compelling evidence through demonstrations on the ISS that materials processing in microgravity improves outcomes for a wide range of materials and products at all levels of the organization of matter, from quantum entities such as Bose-Einstein condensates, to crystals, alloys, composites, thin films, and photonics, to stem cells, medical diagnoses, medical treatments, and medical devices for humans. As of 2026, numerous examples proved by demonstration on ISS show the potential of these technologies in various fields. In this paper, a summary of four important experiments is presented.

microgravity medical devices

Contrasting structural reversibility and magnetic correlations in isostructural honeycomb magnets CrCl3 and 𝛼−RuCl3

We report a comparative neutron single crystal diffraction study of the structural and magnetic properties of layered halides CrCl3 and 𝛼−RuCl3. They host a honeycomb arrangement of transition metal ions with distinct electronic configurations and undergo a first-order structural transition between high-temperature 𝐶⁢2/𝑚 and low-temperature 𝑅⁢‾‾‾3. Both compounds show a step-like change in the 𝑐-lattice parameter across the structure transition. In contrast, the in-plane lattice response is quite different: 𝛼−RuCl3 exhibits an abrupt hysteretic change across the transition accompanied by progressive crystalline degradation upon thermal cycling, whereas CrCl3 shows a smooth in-plane lattice evolution and remains structurally robust. Magnetically, CrCl3 orders into an A-type antiferromagnetic structure at 𝑇𝑁=14 K and exhibits pronounced diffuse magnetic scattering extending up to about 40 K. 𝛼−RuCl3 shows no observable magnetic diffuse scattering above its zigzag antiferromagnetic ordering temperature 𝑇𝑁=7.6 K. These results suggest that the contrasting structural responses arise from an interplay between interlayer sliding energetics, stacking-strain coupling, and elastic accommodation of the stacking transition. The distinct chemical bonding and electronic configurations of the two compounds provide a microscopic basis for their different lattice responses to the structure transition and magnetic correlations.

Morgan, Zachary [ORNL] (ORCID:0000000243625911)

Correlating Impacts of Injected Fuels on Carbon Emissions in Blast Furnace with Computational Fluid Dynamics Modeling

A major challenge for steelmaking is the reduction of CO 2 emissions. In this regard, the blast furnace (BF) is critical due to the high associated CO 2 levels. This investigation assesses the impact of tuyere‐injected fuels on BF CO 2 emissions. Specifically, computational fluid dynamics results obtained previously at Purdue University Northwest are analyzed to obtain CO 2 emissions when natural gas (NG), syngas, hydrogen, or hydrogen/NG are injected. CO 2 emissions are compared with those produced when 95 kg of NG/thm is injected. Among these scenarios, the largest CO 2 reduction occurs when 102 kg of syngas/thm (COG feedstock #1) is injected at 973 K, reducing CO 2 by 190.6 kg thm −1 . The largest CO 2 reduction obtained with NG occurs when 130 kg thm −1 is injected at 600 K, reducing emissions by 65 kg thm −1 . H 2 injection also reduces CO 2 , but requires careful adjusting to reach stable operation. For instance, injecting 35 kg of H 2 /thm reduces CO 2 by 52 kg thm −1 . Increasing gaseous injection rates can significantly reduce CO 2 emissions, with fuel preheating providing an addendum, but high injection rates can lead to unstable operation. Furthermore, results show a correlation between CO 2 emissions and average temperature of shaft region for multiple fuels and injection conditions.

Metallurgy & Metallurgical Engineering

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Correlated Ion Transport Governed by Dynamic Local Structure in High Concentration and Localized High Concentration Electrolytes

Understanding the dynamics of cluster formation and network percolation provides the mechanistic link between microscopic solvation structure and transport in concentrated electrolytes, including localized high-concentration electrolytes (LHCEs). Although recent studies have shown LHCEs to form micelle-like aggregates at specific compositions, a quantitative understanding of how solvation structures and transport properties depend on salt–solvent–diluent ratios remains limited. Here, we integrate molecular dynamics with Onsager transport analyses to chart the evolution of solvation microstructure and associated ionic transport in LiFSI/DMC/TTE, achieving good agreement with experimental conductivities across composition. We show that micelle formation arises from a dynamic instability of the cation–anion network, and that network percolation is the primary determinant of conductivity. Two compositional thresholds emerge: A critical network concentration (CNC) and a critical micelle concentration (CMC) that delineate transitions from extended percolating networks to micelle-like clusters and then to fragments. These structural transitions rationalize the nonintuitive conductivity decrease at intermediate dilution despite monotonically decreasing viscosity and provide composition-level design rules for LHCEs.

Mohanakrishnan, Rohith Srinivaas [University of Ca

Photophysical and Time‐resolved Infrared Properties of Long‐Lived Rhenium(I) 4,5‐Diazafluorene Tricarbonyl Chromophores

This report investigates the synthesis, structural characterization, fundamental molecular photophysics, electrochemistry, UV-Vis spectroelectrochemistry, and time-resolved infrared spectroscopic properties of eight [fac-Re(dafR)(CO) 3 L] 0/+ complexes, where R=ethyl [(dedaf); 1, 3, 5, 7] or H [(dafH); 2, 4, 6, 8] and L=Cl− (1, 2), imidazole [(Im); 3, 4], 4-ethylpyridine [(4-Etpy); 5, 6], or pyridine [(py); 7, 8]. Universally, 1–8 yield higher energy photoluminescence (PL) emission bands and higher PL quantum yields (up to 53 %) than the classic 2,2’-bipyridine (bpy) and 1,10-phenanthroline (phen) ligated Re(I) tricarbonyl complexes. The excited state lifetimes of 1–8 lie between those corresponding to the bpy and phen derivatives, ranging from 120 and 1300 ns at room temperature. Combinations of reductive UV-Vis spectroelectrochemistry, transient absorption spectroscopy, and time-resolved infrared spectroscopy consistently assigned the lowest excited states in 1–8 being of metal-to-ligand charge transfer (MLCT) character. These new ReI MLCT chromophores follow classic energy gap law behavior and possess the characteristics necessary for serving as valuable photosensitizers suitable to energize excited state electron and energy transfer photochemistry.

Charge transfer

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

inviscid theory

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

Anion-dependent phase behavior of methylimidazolium-based ionic liquids mixed with water: Correlation between local molecular structure and mesoscale behaviors

The mesoscopic phase behavior of decylmethylimidazolium (C 10 mim) ionic liquids (ILs) bearing three monovalent anions—thiocyanate (SCN − ), nitrate (NO 3 − ), and chloride (Cl − )—mixed with water at relatively high IL contents (50–95 wt%) was investigated. Small-angle and wide-angle X-ray scattering (SAXS/WAXS) were employed to follow the evolution of both local and mesoscale structures across this composition range. In the absence of water, C 10 mimSCN and C 10 mimCl behaved as disordered liquids, whereas C 10 mimNO 3 spontaneously formed a hexagonally ordered cylindrical mesophase and displayed a sticky-solid macroscopic appearance. Upon addition of water, C 10 mimSCN remained a viscous liquid and only weakly ordered lamellar domains were observed. This limited ordering is attributed to the lack of hydrogen bonding and weak interaction energy between SCN − anions and C 10 mim + cations. In contrast, the trigonal-planar NO 3 − and point-like Cl − anions promoted the formation of well-defined hexagonal mesophases up to 35–45 wt% water. The formation of hydrogen bonding of the two anions with imidazolium ring protons likely enabled the creation of compact ion clusters that effectively exclude water molecules from the immediate vicinity of the IL aggregates. These findings demonstrate that the interaction energy between ion pairs dictate IL-water interactions and therefore control the transition from disordered liquids to ordered mesophases in IL/water mixtures with high IL contents. In conclusion, the combined SAXS/WAXS analysis reveals a correlation between local intermolecular structure and the emergence of mesoscopic order, providing a systematic framework for tailoring mesoscale structures in alkylimidazolium-based IL/water systems.

36 MATERIALS SCIENCE