Search NASA⌕ Search

SEARCH · Search NASA

Results for “recirculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 deg is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.

Tedder, Sarah A.↗

Investigations of Multiple Swirl-Venturi Fuel Injector Concepts: Recent Experimental Optical Measurement Results for 1-Point, 7-Point, and 9-Point Configurations

This paper presents results obtained during testing in optically-accessible, JP8-fueled, flame tube combustors using swirl-venturi lean direct injection (LDI) research hardware. The baseline LDI geometry has 9 fuel/air mixers arranged in a 3 x 3 array within a square chamber. 2-D results from this 9-element array are compared to results obtained in a cylindrical combustor using a 7-element array and a single element. In each case, the baseline element size remains the same. The effect of air swirler angle, and element arrangement on the presence of a central recirculation zone are presented. Only the highest swirl number air swirler produced a central recirculation zone for the single element swirl-venturi LDI and the 9-element LDI, but that same swirler did not produce a central recirculation zone for the 7-element LDI, possibly because of strong interactions due to element spacing within the array.

gas turbine combustion↗

Characterizing the Vertical Processes of Ozone in Colorado's Front Range Using the GSFC Ozone Dial

Although characterizing the interactions of ozone throughout the entire troposphere are important for health and climate processes, there is a lack of routine measurements of vertical profiles within the United States. In order to monitor this lower ozone more effectively, the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center TROPospheric OZone DIfferential Absorption Lidar (GSFC TROPOZDIAL) has been developed and validated within the Tropospheric Ozone Lidar Network (TOLNet). Two scientifically interesting ozone episodes are presented that were observed during the 2014 Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER AQ) campaign at Ft. Collins,Colorado.The first case study, occurring between 22-23 July 2014, indicates enhanced concentrations of ozone at Ft. Collins during nighttime hours, which was due to the complex recirculation of ozone within the foothills of the Rocky Mountain region. Although quantifying the ozone increase a loft during recirculation episodes has been historically difficult, results indicate that an increase of 20 -30 ppbv of ozone at the Ft. Collins site has been attributed to this recirculation. The second case, occurring between Aug 4-8th 2014, characterizes a dynamical exchange of ozone between the stratosphere and the troposphere. This case, along with seasonal model parameters from previous years, is used to estimate the stratospheric contribution to the Rocky Mountain region. Results suggest that a large amount of stratospheric air is residing in the troposphere in the summertime near Ft. Collins, CO. The results also indicate that warmer tropopauses are correlated with an increase in stratospheric air below the tropopause in the Rocky Mountain Region.

Sullivan, John T.↗

Laminar to Turbulence Transition in Boundary Layers due to Tripping Devices

Direct numerical simulations (DNS)and linear stability analysis were performed to identify the mechanisms by which two-and three-dimensional trips promote early transition in subsonic boundary layers over a flat plate. Investigations were conducted for two boundary layer transition trip configurations: one is a two-dimensional rectangular-shaped rod and the other is a three-dimensional zigzag tape. Reynolds numbers based on the trip heights are 683 and 300 for the two-and three-dimensional trips, respectively. Simulations with the two-dimensional trip showed that the flow separates at the top of the trip and forms a long recirculation zone downstream. However, the flow remains steady in the simulation without any external disturbances. Linear stability analysis showed that the inflectional profile in the recirculation zone is strongly unstable to frequencies in the range of 100-300 Hz. Simulations with the external disturbances forced at the frequency of 200 Hz showed that disturbances grow strongly inside the recirculation zone as observed in the Klebanoff1 experiment.

Transition↗

Laminar to Turbulence Transition in Boundary Layers due to Tripping Devices

Direct numerical simulations (DNS)and linear stability analyses were performed to identify the mechanisms by whichtwo-and three-dimensional trips promote early transition in subsonic boundary layers over a flat plate. Investigations were conducted for threeboundary-layer transition trip configurations:a two-dimensional smooth hump,a two-dimensional rectangular-shapedrod and a three-dimensional zig-zagtape. The smooth hump was used by Park et al.1in the linear and nonlinear parabolized stability (PSE) computations. Reynolds numbersbased on the tripheights are 710, 683,and 300 for the two-and three-dimensional trips, respectively. Simulations withthe smooth hump showed that the flow becomes stable upstream and strongly unstable downstream of the hump. Simulations with the two-dimensional rectangular trip showed that the flow separates at the top of the trip and forms a long recirculation zonedownstream. However, the flow remains steady in the simulation without any external disturbances. Linear stability analysis showed that the inflectional profile in the recirculation zone is strongly unstable to frequencies in the range of 100-300 Hz. Simulations with the external disturbances forced at the frequency of 200 Hz showed that disturbances grow strongly inside the recirculation zone as observed in the Klebanoff2 experiment. Three-dimensional simulations with secondary disturbances of fundamental, subharmonic, and oblique types produced turbulent flows shortlydownstream. The three-dimensional zig-zag trip with a small roughness Reynolds number lead to early breakdown to a turbulent flow.

Stability↗

Advanced deep sea diving equipment

Design requirements are generated for a deep sea heavy duty diving system to equip salvage divers with equipment and tools that permit work of the same quality and in times approaching that done on the surface. The system consists of a helmet, a recirculator for removing carbon dioxide, and the diver's dress. The diver controls the inlet flow by the recirculatory control valve and is able to change closed cycle operation to open cycle if malfunction occurs. Proper function of the scrubber in the recirculator minimizes temperature and humidity effects as it filters the returning air.

Danesi, W. A.↗

Experimental Study of Isothermal Wake-Flow Characteristics of Various Flame-Holder Shapes

An investigation of the isothermal wake-flow characteristics of several flame-holder shapes was carried out in a 4- by 4-inch flow chamber. The effects of flame-holder-shape changes on the characteristics of the Karman vortices and thus on the recirculation zones to which experimenters have related the combustion process were obtained for several flame holders. The results may furnish a basis of correlation, of combustion efficiency and stability for similarly shaped flame holders in combustion studies. Values of the spacing ratio-(ratio of lateral spacing to longitudinal spacing of vortices] obtained for the various shapes approximated the theoretical value of 0.36 given by the Karman stability analysis. Variations in vortex strength of more than 200 percent and in frequency of more than 60 percent were accomplished by varying flame-holder shape. A maximum increase in the recirculation parameter of 56 percent over that for a conventional V-gutter was also obtained. Varying flameholder shape and size enables the designer to select many schedules of variations in vortex strength and frequency- not obtainable by changing size only and may make it possible to approach theoretical maximum vortex strength for any given frequency.

Younger, G. G.↗

Flow characteristics of various swirl-can module designs

Flow measurements were performed on each of six swirl-can combustor module designs under simulated combustor operating conditions to find the design which exhibited a small recirculation zone, intense air mixing, and good fuel distribution in its wake. Conditions that are favorable for producing low oxides of nitrogen emissions and high combustion efficiency were investigated. The recirculation zone, the turbulence intensity and the fuel distribution pattern are obtained in the wake region of the center module of a three module array. The most promising swirl-can module design incorporates two air swirlers which discharge air in opposite directions (contraswirl), mixes the fuel and air upstream of the inner swirler, and has a flow area blockage of 64.3% for the three module array.

Mularz, E. J.↗

Advanced water iodinating system

Potable water stores aboard manned spacecraft must remain sterile. Suitable sterilization techniques are needed to prevent microbial growth. The development of an advanced water iodinating system for possible application to the shuttle orbiter and other advanced spacecraft, is considered. The AWIS provides a means of automatically dispensing iodine and controlling iodination levels in potable water stores. In a recirculation mode test, simulating application of the AWIS to a water management system of a long term six man capacity space mission, noniodinated feed water flowing at 32.2 cu cm min was iodinated to 5 + or - ppm concentrations after it was mixed with previously iodinated water recirculating through a potable water storage tank. Also, the AWIS was used to successfully demonstrate its capability to maintain potable water at a desired I2 concentration level while circulating through the water storage tank, but without the addition of noniodinated water.

Davenport, R. J.↗

Turbulent atmospheric flow over a backward-facing step

The phenomenon of atmospheric shear layer separation over a man-made structure such as a building (modeled as a backward-facing step) has been analyzed theoretically by (1) solving the two-dimensional equations of motion in the two variables, stream function and vorticity, and by (2) employing an approximate integral technique. Boundary conditions for the undisturbed flow are that of the turbulent atmospheric shear flow over a rough terrain. In the first approach a two-equation model of turbulence was used. In the second approach an approximate technique was utilized in an attempt to describe the details of the flow in the recirculation zone behind the step. The results predict velocity profiles in sufficient detail that the presence of the corner eddy in the region of negative surface pressure gradient is evident. The magnitude of the reversed flow velocity in the recirculation eddy has been found to agree with that found from experiments. Also, a surface eddy viscosity distribution has been an outgrowth of the method which realistically follows the magnitude of the surface pressure gradient distribution as found experimentally.

Kaul, U. K.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

Two-dimensional computer code for design assessment of SRM aft closure environment

A general interpolants method for constructing numerical analogs of the partial differential equations of continuum mechanics and which combines the best features of both finite element and finite difference methods was used in a two dimensional axisymmetric analysis of the space shuttle solid motor aft closure region flowfield. The numerical technique used is discussed as well as the results of the analysis. A steady state solution for the submerged nozzle nose region indicates the development of an area gas flow recirculation near the propellant burning surface boundary and in the region of the underside of the nozzle nose. This recirculation region remains spatially fixed for successive iterations (greater than 800) of the solution.

Freeman, J. A.↗

An experimental map of the internal structure of a vortex breakdown

The flow field of an 'axisymmetric' vortex breakdown has been mapped using a laser-Doppler anemometer. The interior of the recirculation zone is dominated by energetic, non-axisymmetric, low frequency periodic fluctuations. Spectra for a number of points inside this zone, as well as time-averaged swirl and axial velocity profiles both inside and outside the recirculation zone, have been obtained. The time-averaged streamlines in the interior show an unexpected two-celled structure attributed to the action of the fluctuations. Although the present experiment deals with one particular breakdown, flow-visualization studies indicate that the case examined is typical of the 'axisymmetric' form of breakdown over a range of flow conditions.

Faler, J. H.↗

Effects of flameholder blockage on emissions and performance of lean premixed-prevaporized combustors

Results from a parametric study are presented. Tests were on conducted at inlet air pressure of 300,000 and 500,000 pascals, inlet air temperatures of 600K, 700K and 800K, reference velocites from 20 to 35 meters per second, and equivalent ratios from the lean stability limit to 0.7 using Jet A fuel. The tests were conducted in a closed duct test facility. Results from the test support the theory that flameholder blockage is one of the major determinants of the size and shape of the recirculation zone. The test data show that higher blockage with its larger recirculation zone provides more residence time which leads to more NOx formation.

Duerr, R. A.↗

Lean combustion limits of a confined premixed-prevaporized propane jet

An experimental study was carried out to determine the effects of jet velocity and confinement on lean premixed-prevaporized propane/air blowout limits. The combustor consisted of a single hole flameholder within a quartz liner. Five flameholder plates and two quartz liners were used. Lean stability limits were mapped for confined propane jet in cylindrical combustor. Three zones of flame stability were observed depending on the liner and jet Reynolds number and the combustor geometry. At low Reynolds number the combustor was jet stabilized. As the Reynolds number was increased the combustor became either recirculation zone stabilized, or for small recirculation zone step sizes, the combustor was wall stabilized. The factors affecting stability seem to be the Reynolds numbers of the liner and inlet jet along with the flameholder step size. Stability was achieved at both laminar and turbulent conditions.

Huck, K. L.↗

Space transportation system solid rocket booster thrust vector control system

The Solid Rocket Booster, Thrust Vector Control (TVC) system was designed in accordance with the following requirements: self-contained power supply, fail-safe operation, 20 flight uses after exposure to seawater landings, optimized cost, and component interchangeability. Trade studies were performed which led to the selection of a recirculating hydraulic system powered by Auxiliary Power Units (APU) which drive the hydraulic actuators and gimbal the solid rocket motor nozzle. Other approaches for the system design were studied in arriving at the recirculating hydraulic system powered by an APU. These systems must withstand the imposed environment and be usable for a minimum of 20 Space Transportation System flights with a minimum of refurbishment. The TVC system has completed the major portion of qualification and verification tests and is prepared to be cleared for the first Shuttle flight (STS-1). Substantiation data will include analytical and test data.

Verble, A. J., Jr.↗

Lightweight cryogenic vessel

Thin cooling jacket of recirculating liquid nitrogen is contained by relatively thin walls. Nitrogen is maintained at slight positive pressure, unlike full atmospheric pressure of conventional Dewar design, eliminating need for evacuated insulating spaces and heavy-walled shells. Besides cryogenic applications, design keeps liquids hot when recirculating liquid hotter than nitrogen is used.

Lewis, J. C.↗

Engine bleed air reduction in DC-10

An 0.8 percent fuel savings was achieved by a reduction in engine bleed air through the use of cabin air recirculation. The recirculation system was evaluated in revenue service on a DC-10. The cabin remained comfortable with reductions in cabin fresh air (engine bleed air) as much as 50 percent. Flight test verified the predicted fuel saving of 0.8 percent.

Newman, W. H.↗