Search NASA⌕ Search

SEARCH · Search NASA

Results for “recursive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Generalized Quantum Signal Processing

Quantum signal processing (QSP) and quantum singular value transformation (QSVT) currently stand as the most efficient techniques for implementing functions of block-encoded matrices, a central task that lies at the heart of most prominent quantum algorithms. However, current QSP approaches face several challenges, such as the restrictions imposed on the family of achievable polynomials and the difficulty of calculating the required phase angles for specific transformations. In this paper, we present a generalized quantum signal processing (GQSP) approach, employing general SU(2) rotations as our signal-processing operators, rather than relying solely on rotations in a single basis. Our approach lifts all practical restrictions on the family of achievable transformations, with the sole remaining condition being that | P | ≤ 1 , a restriction necessary due to the unitary nature of quantum computation. Furthermore, GQSP provides a straightforward recursive formula for determining the rotation angles needed to construct the polynomials in cases where P and Q are known. In cases where only P is known, we provide an efficient optimization algorithm capable of identifying in under a minute of GPU time, a corresponding Q for polynomials of degree on the order of 10 7 . We further illustrate GQSP simplifies QSP-based strategies for Hamiltonian simulation, offer an optimal solution to the ϵ -approximate fractional query problem that requires O ( ( 1 / δ ) + log ( 1 / ϵ ) ) queries to perform where O ( 1 / δ ) is a proved lower bound, and introduces novel approaches for implementing bosonic operators. Moreover, we propose a novel framework for the implementation of normal matrices, demonstrating its applicability through synthesis of diagonal matrices, as well as the development of a new algorithm for convolution through synthesis of circulant matrices using only O ( d log N + log 2 N ) 1 and 2-qubit gates for a filter of lengths d . Published by the American Physical Society 2024

Motlagh, Danial↗

Study of interface reaction in a B 4 C/Cr mirror at elevated temperature using soft X-ray reflectivity

Boron carbide is a prominent material for high-brilliance synchrotron optics as it remains stable up to very high temperatures. The present study shows a significant change taking place at 550°C in the buried interface region formed between the Cr adhesive layer and the native oxide layer present on the silicon substrate. An in situ annealing study is carried out at the Indus-1 Reflectivity beamline from room temperature to 550°C (100°C steps). The studied sample is a mirror-like boron carbide thin film of 400 Å thickness deposited with an adhesive layer of 20 Å Cr on a silicon substrate. The corresponding changes in the film structure are recorded using angle-dependent soft X-ray reflectivity measurements carried out in the region of the boron K-edge after each annealing temperature. Analyses performed using the Parratt recursive formalism reveal that the top boron carbide layer remains intact but interface reactions take place in the buried Cr–SiO2 region. After 300°C the Cr layer diffuses towards the substrate. At higher temperatures of 500°C and 550°C the Cr reacts with the native oxide layer and tends to form a low-density compound of chromium oxysilicide (CrSiOx). Depth profiling of Si and Cr distributions obtained from secondary ion mass spectroscopy measurements corroborate the layer model obtained from the soft X-ray reflectivity analyses. Details of the interface reaction taking place near the substrate region of boron carbide/Cr sample are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

On Projection of Safe Operation for Grid-Following Inverters - Grid Parameter Estimation

This work investigates the projection of safe operation for grid-following inverters using a reference model. This work applies recursive-least square and model reference adaptive estimation techniques to estimate the unknown grid parameters. The estimated grid parameters are used in a dynamic reference model to project the safe operation of the inverter. This work also demonstrates that the controller nonlinearity and parameter variations can cause unsafe operations, such as unexpected instability at low power levels, namely hidden mode of instability. This instability issue in the nominal operating range may occur for given control parameters in a weak-grid condition. The dynamic reference model for PQ-controlled inverters is applied to analyze this instability issue using the estimated grid parameters. Both adaptive identification techniques can estimate the unknown parameters accurately, and the dynamic reference model can safeguard inverters from an unsafe operation, i.e., hidden instability, by examining the incoming new power setpoints before engaging them to the local controller. The findings are experimentally verified using a small-scale two-level 208 V, 5 kVA inverter feeding a 12 kW NHR 9410 power grid emulator.

Hossen, Tareq↗

Online Dynamic Mode Decomposition Based System Identification of Multi-Zone Building HVAC Systems

Many works have recently been conducted to reduce the electricity consumption of smart buildings and allow them to support various grid services. Most of these works require accurate system models for the various appliances in the building including heating, ventilation, and air conditioning (HVAC) units. In this paper, we investigate a recursive data-driven system identification strategy to construct the thermal model for a time-varying building with a multi-zone HVAC unit. The online dynamic mode decomposition (DMD)-based strategy is employed to identify the multi-zone thermal building dynamics, where a simple information update (rank-1) is selected to avoid computational complexity. The DMD-based identification strategy is validated using a real gymnasium building equipped with a 4-zone HVAC unit, and its performance is compared with that of the traditional nuclear-norm subspace identification (N2SID) strategy.

Wu, Tumin [University of Tennessee, Knoxville (UTK↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, previous synchronization analysis for heterogeneous systems requires the machines to satisfy certain proportionality property. In our approach, the effective transfer functions for each cluster can be tuned by the IBRs to satisfy such property, enabling us to apply the shaping control to systems with a wider range of heterogeneous machines.

frequency-shaping control↗

Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid

The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Superconvergence of Online Optimization for Model Predictive Control

We develop a one-Newton-step-per-horizon, online, lag-L, model predictive control (MPC) algorithm for solving discrete-time, equality-constrained, nonlinear dynamic programs. Based on recent sensitivity analysis results for the target problems class, we prove that the approach exhibits a behavior that we call superconvergence; that is, the tracking error with respect to the full horizon solution is not only stable for successive horizon shifts, but also decreases with increasing shift order to a minimum value that decays exponentially in the length of the receding horizon. The key analytical step is the decomposition of the one-step error recursion of our algorithm into algorithmic error and perturbation error. We show that the perturbation error decays exponentially with the lag between two consecutive receding horizons, while the algorithmic error, determined by Newton’s method, achieves quadratic convergence instead. Overall this approach induces our local exponential convergence result in terms of the receding horizon length for suitable values of L. In conclusion, numerical experiments validate our theoretical findings.

97 MATHEMATICS AND COMPUTING↗

Modeling and Control Using Stochastic Distribution Control Theory for Intersection Traffic Flow

In this work, we investigated stochastic distribution control theory-based traffic signal optimization to achieve a smooth and uniform flow of vehicles through signalized intersections. In this context, the static and linear dynamic stochastic distribution models were developed to express the relationship between the signal timing and the traffic queue length together with its probability density function. Two stochastic distribution control algorithms were designed to control the signal timing at intersections such that the probability density function of the traffic queue of each intersection road segment is made as narrow and as small as possible. Also, a recursive input-output traffic queue estimation model was proposed, which is data-driven and dynamic in nature, to calculate real-time traffic queue length using traffic signal timings and loop-detector data. The control algorithms were evaluated for a one-signal corridor, two-signal corridor, and 2 x 2 network of signalized intersections. MATLAB simulation examples are provided to demonstrate the use of the proposed algorithms and comparison to the existing widely-used semi-actuated control has been made. Desired results were obtained.

97 MATHEMATICS AND COMPUTING↗

Data Driven Optimization Framework for Volt-age Regulation in Distribution Systems

This letter proposes a data-driven optimization framework for voltage regulation problems to address the challenge of model inaccuracy and parameter varying. To achieve online voltage optimization, the recursive kernel regression and interior point methods are integrated. The IEEE 123-Bus system and EPRI Ckt5 feeder are selected to validate the effectiveness of the proposed data-driven optimization framework. The proposed method is also compared with a linear function based method.

Hong, Tianqi↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity of modelled passive margin stratigraphy to variations in sea level, sediment supply and subsidence

Abstract We produced a 10 Myr synthetic stratigraphic section using a forward stratigraphic model that generates marine deltaic stratigraphy over geological timescales. We recursively fit the model using a Bayesian inversion algorithm to test: (1) if it could be accurately reconstructed; (2) if the parameters used to create it could be recovered; and (3) the sensitivity of the model output to given model parameters and the attendant physical processes. The original synthetic stratigraphic section was produced with cyclical sea‐level variations of 40 and 30 m with 2.4 and 10 Myr periods respectively. Sediment was also supplied cyclically, in 2.4 and 10 Myr cycles with amplitudes of 30 and 80 tons/100 kyr, respectively, varying from a mean of 232 tons/100 kyr. Parameter values were sampled to fit the model using a Markov chain Monte Carlo algorithm, resulting in a ±5 m (1σ) variation between the experimental output and the original. Sea level varied by ±7 m (1σ) within the posterior distribution of parameters. As a result, both the 10 Myr and 2.4 Myr sea‐level cycles could be extracted from the original output. The variation in sediment supply was approximately ±38 tons/100 kyr (1σ) and, as a result, only the larger long‐term supply variations could be accurately recovered in refitting the model. The variation in thermal, flexural and total subsidence across those parameter sets is less than ±10 m (1σ). The original section experienced 150 m of total subsidence at the depocentre. Our results demonstrate the distinct and interpretable imprint of sea level and subsidence on continental margin stratigraphy can be quantified. Moreover, we conclude that sea‐level change produces a defined effect on the geometries of stratigraphic architecture, and that techniques applied for the purpose of delineating sea‐level variation from continental margin strata have a well‐founded conceptual basis.

Schmelz, William J.↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Surrogate Modeling of Nonlinear Dynamic Systems: A Comparative Study

Surrogate models play a vital role in overcoming the computational challenge in designing and analyzing nonlinear dynamic systems, especially in the presence of uncertainty. This paper presents a comparative study of different surrogate modeling techniques for nonlinear dynamic systems. Four surrogate modeling methods, namely, Gaussian process (GP) regression, a long short-term memory (LSTM) network, a convolutional neural network (CNN) with LSTM (CNN-LSTM), and a CNN with bidirectional LSTM (CNN-BLSTM), are studied and compared. All these model types can predict the future behavior of dynamic systems over long periods based on training data from relatively short periods. The multi-dimensional inputs of surrogate models are organized in a nonlinear autoregressive exogenous model (NARX) scheme to enable recursive prediction over long periods, where current predictions replace inputs from the previous time window. Three numerical examples, including one mathematical example and two nonlinear engineering analysis models, are used to compare the performance of the four surrogate modeling techniques. The results show that the GP-NARX surrogate model tends to have more stable performance than the other three deep learning (DL)-based methods for the three particular examples studied. The tuning effort of GP-NARX is also much lower than its deep learning-based counterparts.

42 ENGINEERING↗

Multilevel Spectral Coarsening for Graph Laplacian Problems with Application to Reservoir Simulation

We extend previously developed two-level coarsening procedures for graph Laplacian problems written in a mixed saddle point form to the fully recursive multilevel case. The resulting hierarchy of discretizations gives rise to a hierarchy of upscaled models, in the sense that they provide approximation in the natural norms (in the mixed setting). This property enables us to utilize them in three applications: (i) as an accurate reduced model, (ii) as a tool in multilevel Monte Carlo simulations (in application to finite volume discretizations), and (iii) for providing a sequence of nonlinear operators in a full approximation scheme for solving nonlinear pressure equations discretized by the conservative two-point flux approximation. Finally, we illustrate the potential of the proposed multilevel technique in all three applications on a number of popular benchmark problems used in reservoir simulation.

multilevel Monte Carlo↗

Fast Solution of Fully Implicit Runge--Kutta and Discontinuous Galerkin in Time for Numerical PDEs, Part I: the Linear Setting

Fully implicit Runge--Kutta (IRK) methods have many desirable properties as time integration schemes in terms of accuracy and stability, but high-order IRK methods are not commonly used in practice with numerical PDEs due to the difficulty of solving the stage equations. This paper introduces a theoretical and algorithmic preconditioning framework for solving the systems of equations that arise from IRK methods applied to linear numerical PDEs (without algebraic constraints). Additionally, this framework also naturally applies to discontinuous Galerkin discretizations in time. Under quite general assumptions on the spatial discretization that yield stable time integration, the preconditioned operator is proven to have condition number bounded by a small, order-one constant, independent of the spatial mesh and time-step size, and with only weak dependence on number of stages/polynomial order; for example, the preconditioned operator for 10th-order Gauss IRK has condition number less than two, independent of the spatial discretization and time step. The new method can be used with arbitrary existing preconditioners for backward Euler-type time-stepping schemes and is amenable to the use of three-term recursion Krylov methods when the underlying spatial discretization is symmetric. The new method is demonstrated to be effective on various high-order finite-difference and finite element discretizations of linear parabolic and hyperbolic problems, demonstrating fast, scalable solution of up to 10th-order accuracy. The new method consistently outperforms existing block preconditioning approaches, and in several cases, the new method can achieve 4th-order accuracy using Gauss integration with roughly half the number of preconditioner applications and wallclock time as required using standard diagonally IRK methods.

97 MATHEMATICS AND COMPUTING↗