Search NASA⌕ Search

SEARCH · Search NASA

Results for “reduced temperature trends”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigating Tropical Versus Extratropical Influences on the Southern Hemisphere Tropical Edge in the Unified Model

Abstract Since the late 1970s, observations have shown a widening of the tropical Hadley cell (HC) circulation. State‐of‐the‐art climate models reproduce the general trend along with a projected continuous expansion. Discrepancies in expansion rates of observation‐ and model‐based studies have been attributed to differences in applied methods, natural variability and model shortcomings. Furthermore, the driving influence of tropical or extratropical processes on these changes is not well understood. All of this highlights the dynamical mechanisms and the region of origin controlling the tropical width are still insufficiently understood. Here we examine the influence of systematic model biases of the atmosphere‐only Unified Model (UM) onto the simulation of the Southern Hemisphere (SH) tropical edge. We utilize nudged experiments with prescribed sea surface temperatures, where potential temperature and horizontal winds are relaxed back to ERA‐Interim reanalysis for a 20‐year period in selected regions. Correcting model biases in the tropics and extratropics separately allows us to dissect the dominant remote impacts of present model errors onto the SH tropical edge simulation. The experiments are applied to established tropical width metrics ranging from near‐surface to upper‐level metrics capturing the poleward flank of the HC. We find both regions work remotely to reduce errors in the UM fields and location of the tropical edge. Surprisingly, correcting the extratropical biases, south of 45°S, more consistently improves the tropical width across the metrics and seasons than nudging the tropics (10°N–10°S). These findings demonstrate the substantial role of extratropical influences in locating the SH tropical edge.

54 ENVIRONMENTAL SCIENCES↗

Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series: Supporting Data

This dataset consists of soil temperature time series that were used to estimate soil thermal diffusivity and its uncertainty trough the probabilistic modelling approach developed and presented in the article named "Probabilistic estimation of depth-resolved profiles of soil thermal diffusivity from temperature time series" and published in Earth Surface Dynamics. There are two compressed (.zip) files that contains synthetic (Synthetic_soiltemp_Teller.zip) and field (Field_soiltemp_Teller.zip) data. There is one MATLAB file that requires MATLAB to execute but any text editor can open it. The Synthetic_soiltemp_Teller.zip file includes 5 comma-delimited data files (.csv) each of which contains soil temperature time series generated through forward modeling (i.e., heat-conduction process in a heterogeneous medium using an explicit finite difference method) to mimic various types of temperature gradients, trend and fluctuations. These synthetic soil temperatures were used to investigate the impact of different environmental conditions on the uncertainty of thermal diffusivity estimates. The Field_soiltemp_Teller.zip file contains 28 comma-delimited data files (.csv) out of which (a) 27 files includes soil temperature time series recorded from 27 temperature probes located in a site along Teller Road about 40 km northwest of Nome, Alaska (64.72°N, 165.94°W), (b) one includes the name and coordinates of the 27 probes. These field soil temperatures were used to infer soil thermal diffusivity at numerous locations and depths in a discontinuous permafrost environment, and to evaluate the links between the estimated soil thermal diffusivity values and soil physical properties. The comma-delimited data files (.csv) of the synthetic and field soil temperature time series includes date and time (UTC) in the first column and soil temperature from 5 cm below the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors) in the other columns. The measurements were acquired every 15 minutes. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Intermediate-Term Thermal Aging Effect Evaluation for Grade 92 and 316L at The LWR Relevant Temperature

Life extension of the existing nuclear reactors imposes accumulated damages, such as higher fluences and longer period of corrosion, to structural materials, which would result in significant challenges to the traditional reactor materials such as type 304 and 316 stainless steels. Advanced alloys with superior radiation resistance will increase safety margins, design flexibility, and economics for not only the life extension of the existing fleet but also new builds with advanced reactor designs. The Electric Power Research Institute (EPRI) teamed up with Department of Energy (DOE) on the Advanced Radiation Resistant Materials (ARRM) program, aiming to develop and test degradation resistant alloys from current commercial alloy specifications by 2021 to a new advanced alloy with superior degradation resistance in light water reactor (LWR)-relevant environments by 2024. Based on a comprehensive microstructure and property screening performed in Phase-1 of the ARRM program, a total of five alloys, together with 316L and X-750 as references, were down-selected for Phase-2 neutron irradiation studies. Because thermal aging could exert a synergistic effect on neutron irradiation due to the low neutron damage rate on the order of 10 –7 displacements per atom per second (dpa/s), Grade 92 (one of the five down-selected alloys) and two heats of 316L were selected in this task to study the effect of aging at 350°C for 12.5–12.7 kh on microstructure and mechanical properties. The aging time is approximately corresponding to 5 dpa neutron irradiation, which can be served as a reference for the 5-dpa-irradiated samples of the alloys to help understand the independent neutron damage influence on microstructure and mechanical properties. Optical microscopy and scanning electron microscopy were used for microstructural characterization. Hardness, tensile, Charpy impact toughness, and fracture toughness in the ductile regime of the aged samples were examined. The aging of Grade 92 led to the formation of many Laves phase in sizes of ~100–200 nm and resulted in some reduction in hardness and yield/ultimate tensile strength with some increases in uniform and total plastic elongations, which may have helped the enhancement of Charpy impact toughness, e.g., ~4 J increase in upper-shelf energy and 20.5°C reduction in ductile-brittle transition temperature compared with the unaged condition. The fracture toughness of the aged Grade 92 showed decent toughness of ~303 MPa√m (K Jq ) with ~87 tearing modulus at 22°C, which reduced to ~241 MPa√m (~20% reduction) with ~75 tearing modulus at 300°C. The two heats of 316L are differentiated by their amounts of δ-ferrite, i.e., ~1 vol% in heat T1103 and ~4 vol% in heat N5B8. The two heats of 316L were subjected to 15% cold work (CW) as this condition is often used in nuclear reactors to help trapping radiation-induced defects and thus postpone the steady state swelling stage. The aging did not result in any noticeable microstructure changes, except for possible segregations at grain boundaries that need to be further investigated. The aging resulted in slight reduction in hardness of 316L-T1103 and slight increase in hardness of 316L-N5B8, which is consistent with their tensile testing results. The 15%CW might have introduced some inhomogeneity, resulting in large standard deviations in hardness, which were reduced after the aging. The aged 316L followed the same trend as the unaged condition for the strength and elongation results from the tensile testing. Minimum elongations appeared within ~300–600°C, above which the elongations seem to increase. Unlike the negligible or minor changes in microstructure, hardness and tensile results of the two heats of 316L, their fracture toughness showed noticeable difference. The aged 316L-T1103 showed good toughness of ~350 MPa√m with ~80 tearing modulus at 22°C, which reduced to ~271 MPa√m (~23% reduction) with ~83 tearing modulus at 300°C. In contrast, the aged 316L-N5B8 showed lower toughness of ~244 MPa√m with ~53 tearing modulus at 22°C, which reduced to ~180 MPa√m (~26% reduction) with ~31 tearing modulus at 300°C. The preliminary results indicate that the presence of high volume of δ-ferrite would noticeable impair fracture toughness although it may not influence hardness and tensile properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surrogate Model Integration with MOOSE XFEM for Creep Crack Growth

Ferritic-martensitic steels are key structural materials for advanced reactors but experience time-dependent deformation and damage under prolonged high temperature and irradiation, leading to creep-driven crack initiation and growth. High-fidelity models—crystal plasticity with irradiation mechanisms, phase-field for microstructural evolution, and continuum-damage viscoplasticity—capture the underlying physics but are too computationally intensive for broad design-space exploration and uncertainty quantification. This milestone advances a scalable alternative by integrating a microstructure-sensitive surrogate creep model into the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element framework and extending it to fracture via the extended finite element method (XFEM). The surrogate model, developed with collaborators at Sandia and Los Alamos National Laboratories, maps relevant microstructural descriptors to the viscoplastic response of HT9. We embed this surrogate within a coupled deformation-damage workflow in MOOSE/XFEM to simulate creep-driven crack initiation and propagation. Implementation enhancements include updates to the material interface, a plastic correction phase involving microstructure evolution, and fracture criteria to ensure numerical robustness and compatibility with the surrogate structure. Demonstrations on canonical creep benchmarks spanning uniaxial and multiaxial states show that the surrogate reproduces key trends of high-fidelity models while substantially reducing computational cost. The resulting capability bridges physics fidelity and performance, providing a practical path to a predictive, microstructure-aware assessment of creep and fracture in reactor materials.

36 - MATERIALS SCIENCE↗

Volatile aldehyde emissions from “sub-ohm” vaping devices

"Sub-ohm" atomizers with reduced resistance can deliver more power than conventional electronic cigarettes. Typical battery outputs are 100 watts or more. These devices are particularly popular among young users, and can be a significant source of volatile carbonyls in the indoor environment. Emissions from next-generation sub-ohm vaping products were characterized by determining e-liquid consumption and volatile aldehydes emissions for several combinations of popular high-power configurations. Tests explored the effect of dilution air flow (air vent opening), puffing volume, and coil assembly configuration. The mass of liquid consumed per puff increased as the puff volume increased from 50 to 100 mL, then remained relatively constant for larger puff volumes up to 500 mL. This is likely due to mass transfer limitations at the wick and coil assembly, which reduced the vaporization rate at higher puff volumes. Carbonyl emission rates were systematically evaluated using a 0.15 Ω dual coil atomizer as a function of the puffing volume and dilution air flow, adjusted by setting the air vents to either 100% (fully open), 50%, 25%, or 0% (closed). The highest formaldehyde emissions were observed for the lowest puff volume (50 mL) when the vents 31 were closed (48 ng mg-1), opened at 25% (39 ng mg -1 ) and at 50% (32 ng mg -1 ).. By contrast, 50-mL puffs with 100% open vents, and puff volumes >100 mL for any vent aperture, generated formaldehyde yields of 20 ng mg -1 or lower, suggesting that a significant cooling effect resulted in limited carbonyl formation. Considering the effect of the coil resistance when operated at a voltage of 3.8 V, the amount of liquid evaporated per puff decreased as the resistance increased, in the order of 0.15 Ω > 0.25 Ω > 0.6 Ω consistent with decreasing aerosol temperatures measured at the mouthpiece. Three different configurations of 0.15 Ω coils (dual, quadruple and octuple) were evaluated, observing significant variability. No clear trend was found between carbonyl emission rates and coil resistance or configuration, with highest emissions corresponding to a 0.25 Ω dual coil atomizer. Carbonyl emission rates were compared with those determined using the same methodology for conventional e-cigarettes (lower power tank systems), observing overall lower yields for the sub-ohm devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flame dynamics and kinetic coupling of ammonia and dimethyl-ether in non-premixed cool and warm flames at elevated pressure

Developing advanced low-temperature combustion engines with ammonia-biofuel blends requires a comprehensive understanding of low-temperature flame dynamics and kinetic interactions between ammonia and oxygenated fuels at elevated pressures. This work aims to study the dynamics and kinetics of non-premixed Dimethyl Ether (DME)/Ammonia (NH 3 ) cool and warm flames, and their reignition to hot flames. A counterflow burner is employed to establish DME/NH 3 cool/warm flames at pressures up to 5 atm. The extinction limits of cool flame and the reignition limits of warm flame to hot flame are measured by varying NH 3 concentrations and compared to simulations to quantitatively examine the effects on DME/NH 3 flames. It is found that NH 3 inhibits low-temperature DME oxidation and results in lower cool flame extinction limits. Warm flames in the presence of NH 3 are observed for the first time, revealing a non-monotonic effect of NH 3 addition: a small amount of NH 3 presence enhances warm flame chemistry and promotes reignition to hot flames, while a high NH 3 concentration weakens the warm flame. This trend is further explained by 0-D PSR kinetic simulations and 1-D S-curve flame dynamic calculations. Three flame transition regimes between cool flames (CF), warm flames (WF), and hot flames (HF) by different levels of NH 3 additions at a specific strain rate are identified, namely WFHF reignition, WF-CF transition, and WF extinction. Reaction sensitivity analyses of OH at low temperatures show that NH3 inhibits DME oxidation through OH consumption via H-abstraction and the kinetic couplings of RO 2 /NH 2 , RO 2 /NO x , R/NO x , and O 2 QOOH/NO x further suppress the low-temperature branching. At intermediate-temperatures, NH 2 /NO x /HO 2 coupling promotes warm flames via the pathway NH 2 → H 2 NO → HNO → NO by converting O 2 → HO 2 → OH. At even higher NH₃ concentrations, radical termination reactions of NH 2 + NO/NO 2 and excessive OH consumption via H-abstraction inhibit the flame. The insights into the kinetic coupling between NH 3 and low-temperature chemistry at elevated pressure and its impact on the dynamics of cool-warm-hot flame transitions will contribute to advancing combustion technologies with reduced emissions and improved energy-efficiency.

42 ENGINEERING↗

Decoupling plasma, catalyst, and gaseous mechanisms for non-oxidative methane conversion

Direct non-oxidative methane (CH 4 ) conversion to value-added hydrogen (H 2 ) and C 2 products remains hindered by fundamental catalytic scaling constraints and rapid surface deactivation at elevated temperatures. Plasma-enabled catalysis offers a promising route to overcome the thermodynamic and kinetic barriers of direct non-oxidative methane upgrading at mild conditions, yet control over C–C product selectivity and catalyst stability remains elusive. Here, we establish a unified mechanistic framework including Langmuir–Hinshelwood (L–H) and Langmuir–Rideal (L–R) mechanisms that disentangles the roles of plasma excitation (including vibrationally activated species and radicals), surface temperature (T sur ), and catalyst binding energy in steering CH 4 conversion to H 2 and C 2 hydrocarbons. Through a combination of density functional theory (DFT) informed microkinetic modeling, in situ and ex situ surface characterization, and product quantification under dielectric barrier discharge conditions, we show that vibrationally excited CH 4 lowers activation barriers selectively for dissociative chemisorption, enabling surface activation across a wide range of transition metal catalysts at low thermal energy input. We find that once CH 4 is dissociatively chemisorbed, the branching between C 2 H 2 , C 2 H 4 , and C 2 H 6 is governed by surface properties (carbon binding energy, T sur , etc), regardless of plasma excitation. The DFT informed microkinetic model decouples the effects of molecular activation from surface properties and indentifies operating windows that maximize target yields while suppressing carbon accumulation and subsequent catalytic inactivation. Experiments on polycrystalline Cu/Al 2 O 3 , Ni/Al 2 O 3 , and Pt/Al 2 O 3 validate these predictions, revealing catalyst-dependent branching toward ethane or ethylene and distinct deactivation profiles. We unify these trends into a generalized three-dimensional plasma-thermal-catalytic design space, from which reduced descriptors such as T vib /T sur in the limit of vibrationally excited L–H pathways emerge as predictive metrics. These results enable rational tuning of methane conversion pathways and unlock selective C 2 formation using earth-abundant metals under mild plasma conditions.

catalyst inactivation↗

High-Throughput Ion Irradiation and Microstructural Characterization of Multi-Principal-Element Alloys

Multi-principal-element alloys (MPEAs) have garnered interest in the nuclear community for their apparent resistance to microstructural damage under irradiation. While both experimentation and simulation have demonstrated reduced hardening and void swelling in MPEAs, the relationship between composition and irradiation response is still poorly understood since a rich experimental database for MPEAs does not yet exist. In this work, to accelerate the generation of experimental irradiation-response data for MPEAs, high-throughput synthesis, irradiation, and characterization techniques have been employed. Specifically, additive manufacturing has been used to produce arrays of various MPEAs (1-cm2 coupons), which have been subsequently irradiated using 4-MeV Ni2+ ions to a peak damage of 200 dpa at 500 °C. Hardening and void swelling have been assessed using nanoindentation and trenching via plasma focused ion beam (PFIB), respectively. Trends in the experimental data relating hardening and void swelling behavior to composition have been analyzed using different machine learning approaches.

36 MATERIALS SCIENCE↗

Heat pulse propagation and anomalous electron heat transport measurements on the optimized stellarator W7-X

The optimized stellarator Wendelstein 7-X (W7-X) is designed to have an approximately quasi-isodynamic magnetic configuration with reduced neoclassical transport in comparison to a classical stellarator, and turbulent transport is expected to be a significant source of anomalous heat transport across the plasma minor radius. The ion temperature gradient driven mode and the trapped electron mode (TEM) are thought to be responsible for the ion-scale turbulence in W7-X plasmas with volume averaged pressure below 1%. In this work, the electron temperature gradient driven turbulence is shown to be a good candidate for the explanation of the observed electron heat flux, in the inner plasma region where the density gradient is weak (in the outer region, a relatively stronger density gradient would drive additional TEM turbulence). Further, the experimental electron heat transport measured during electron cyclotron resonant heating power and plasma density scans is compared to neoclassical predictions, and the stiffness in the electron heat transport measured during transient transport experiments is presented in three common magnetic configurations of W7-X. In low-(β) plasma discharges, the stiffness in the electron heat flux, quantified by the ratio of the heat pulse to power balance diffusivity, ${\chi }_{\mathrm{e}}^{\mathrm{H}\mathrm{P}}/{\chi }_{\mathrm{e}}^{\mathrm{P}\mathrm{B}}$, is measured to be less than 2, and trend downwards with increasing collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preshaping clear glass at low temperatures

Advances in available glass chemistries and glass processing methods have accompanied and enabled some of the biggest technology revolutions, from the development and mass production of light bulbs to low-loss fiber optics and durable smartphone touchscreens. An emerging generation of low-temperature processing technologies aims to continue this important trend and make a broader array of glass components mass producible. In the issue, Mader et al. (1) describe one such innovation in glass processing—the use of low-temperature injection molding to preshape silica particle–filled composites that can later be transformed into transparent fused silica glass objects. Traditionally, transparent glass objects are manufactured in high volume from molten or softened glass, which is floated, drawn, blown, cast, or blow-molded to a desired shape (see the figure, top). The glass composition and processing technique dictate the working temperature, which is usually quite high (near 1000°C) and often restricts the choice of compatible equipment or limits the choice of glass composition. Because geometry-specific capital investment is required for production, drastic or frequent component design changes or small batches may be cost prohibitive. Alternatively, transparent glass components can also be shaped at ambient temperature from solid glass by a series of subtractive processes, including cutting or multiple stages of grinding, followed by slower processing steps, such as polishing or etching. This approach is somewhat less amenable to mass production, and certain geometries containing tool-inaccessible regions cannot be fabricated in this way. Several emerging glass-shaping technologies aim to reduce the required manufacturing temperatures and still provide access to a broader range of glass compositions and component geometries (see the figure). These approaches use a three-step process. First, a desired shape is preformed at low temperature from a glass-forming, organic-inorganic composite. Next, the preform is dried, and organic materials used to bind particles are removed. Finally, the preform is heated (sintered) well below the glass-melting temperature to densify to transparent glass. Although the second and third steps do occur at increased temperatures, only standard, geometry-agnostic driers and furnaces are required. This strategy builds on the well-studied sol-gel approach to forming monolithic glass, where silica network–forming chemical solutions are poured into molds, slowly dried, and condensed into dense glass without melting (2). In a departure from the sol-gel process, these new technologies use solvents, cross-linkers, and polymers to formulate organic-inorganic composites tuned for compatibility with a particular shaping process, with formats ranging from photocurable liquids to shear-thickening pastes to solids. The composite inorganic loadings are also typically higher than those in the pure sol-gel approach, which drastically reduces shrinkage in comparison.

36 MATERIALS SCIENCE↗

SHOCK TUBE IGNITION STUDIES OF RENEWABLE DIESEL FUELS FOR MEDIUM AND HEAVY-DUTY TRANSPORTATION

Currently extensive research on alternative fuels is being conducted due to their increasing demand to reduce greenhouse emissions. One renewable fuel studied in this work is dimethyl ether (DME) blended with propane(C3H8) as a potential mixture for heavy-duty engines used in semi-trucks. The blend has the potential to drastically reduce particulate and greenhouse gas emissions compared to a conventional diesel engine operating under similar conditions. To develop the use of mixture, one must conduct detailed conceptual and simulation studies before progressing to detail studies in CFD, engine modifications, and live testing. For simulations, accurate high-fidelity chemical kinetic models are necessary. However, the validity of the chemical kinetic mechanism for operating conditions of a heavy-duty mixing-controlled compression (MCCI) engine was widely unknown until recent work presented here and published. In this work, we studied the ignition of DME and propane blends in a shock tube under MCCI engine conditions. Ignition delay time (IDT) gathered behind the reflected shock for DME-propane mixtures for heavy-duty compression ignition (CI) engine parameters. Testing was conducted for undiluted varieties spanning from temperatures of 700 to 1100 K at pressures ranging from 55 to 84 bar for various blends (100% CH3OCH3, 100% C3H8, 60% CH3OCH3/ 40% C3H8) of DME and propane were combusted in synthetic air (21% O2/ 79% N2). Several experiments were conducted at higher pressures (90-120 bar) to improve the model performance and accuracy. The ignition delay times (IDTs) were compared to recent mechanisms, including Aramco3.0, NUIG, and Dames et al. A common trend among the mechanisms was overpredicted experimental IDTs. Further studies were conducted by a sensitivity analysis using the Dames et al. model, and critical reactions sensitive to IDTs of DME-propane mixture near 60 bar are outlined. Chemical analysis was conducted on the NTC region to explain chemical kinetics which is critical for developing MCCI heavy duty engines.

Mohammed, Zuhayr Pasha↗

Pyrolysis of bio-derived dioxolane fuels: A ReaxFF molecular dynamics study

Alkyl-substituted 1,3-dioxolanes, including 4,5-dimethyl-2-pentan-3-yl-1,3-dioxolane (Fuel 1), 4,5-dimethyl-2-pentyl-1,3-dioxolane (Fuel 2), and 2-(heptan-3-yl)-4,5-dimethyl-1,3-dioxolane (Fuel 3), have been recently suggested as potential biodiesels. In this paper, we investigate the initial pyrolysis of the alkyl-substituted 1,3-dioxolanes at high temperatures using ReaxFF molecular dynamics (MD) simulations. We analyze the decomposition rate, reaction mechanism, and product distribution in the pyrolysis of the three alkyl 1,3-dioxlanes. The three fuels primarily decompose to 4,5-dimethyl-1,3-dioxolane radical and hydrocarbons derived from the alkyl side-chains. The further decomposition of 4,5-dimethyl-1,3-dioxolane radical primarily leads to 2-C 4 H 8 and CO 2 within a few decomposition steps. The hydrocarbon product distribution is significantly affected by the molecular structure of the alkyl side-chain, which would have a strong influence on the sooting tendency of these fuels. The ReaxFF simulations predict that the order of sooting tendency would be Fuel 3 > Fuel 1 > Fuel 2, which agrees with the measured sooting tendency trend. Based on the pyrolysis mechanism identified by ReaxFF, we propose a new alkyl dioxolane, 4-hexyl-5-methyl-1,3-dioxolane (Fuel 4), which might produce even less soot, by modifying the molecular structure of Fuel 2. Our ReaxFF simulation shows that Fuel 4 produce much less C 4 H 8 , an effective non-aromatic soot precursor, than Fuel 2. Moreover, more carbon atoms are bonded to each oxygen atom in Fuel 4 than Fuel 2, which would help reduce soot yield by removing more carbon atoms from the soot-producing pool of species. The major decomposition pathways identified in this work can be used to develop chemical kinetic models for 1,3-dioxolane based compounds, as biodiesel components, applicable to combustion engine simulations. We also demonstrate that the chemical kinetic insight offered by ReaxFF simulations can be used to design new fuel molecules with more desired properties.

09 BIOMASS FUELS↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

The Interplay Between Climate and Urban Expansion on Building Energy Demand in Morocco

Understanding building energy demand is critical for addressing climate uncertainty challenges and ensuring sustainable urban growth. This study develops a building energy demand (BED) model to explore how climate variation and urban expansion affect residential and commercial space heating and cooling demands in Morocco for three scenarios, namely, 2005, 2018, and 2018 + 1.5 °C. The results show that coastal cities have lower heating and cooling needs due to the oceanic influence, while interior cities require significantly higher heating demand per-unit-floorspace. Between 2005 and 2018, urban growth increased total heating and cooling demand by 218.8 GWh, particularly in northern and coastal regions, despite per-unit-floorspace reductions in milder climates and improved building efficiency in 2018. Residential heating remains the dominant energy use, though commercial demand is significant in urban centers. Under the 2018 + 1.5 °C hypothetical scenario, heating demand across Morocco declines by 335.8 GWh compared to 2018, with urban areas amplifying this trend. Meanwhile, cooling demand increases slightly by 44.4 GWh, with major cities experiencing relative increases of up to 50%. These findings highlight a trade-off where reduced winter heating needs are partly offset by increased summer cooling demands in densely urbanized areas. In conclusion, the study identifies key urban hotspots for targeted interventions, emphasizing the need for energy-efficient building designs, climate-adaptive urban planning, and resilient energy management strategies to sustainably address shifting seasonal energy patterns.

Morocco↗

Deactivation trends of Pd/SSZ-13 under the simultaneous presence of NO, CO, hydrocarbons and water for passive NO x adsorption

Pd-functionalized chabazite (Pd/SSZ-13) was evaluated for passive NO x adsorption (PNA) using low temperature combustion with diesel (LTC-D) reaction feed of the “United States Driving Research and Innovation for Vehicle efficiency and Energy sustainability” (U.S.DRIVE) protocol. Notably as per the protocol conditions, 12% O 2 + 6% CO 2 + 6% H 2 O was flown in all cases. NO-uptake studies in the presence of the LTC-D feed showed a systematic decline with (NO:Pd)molar changing from 0.5 to 0.4 after 10 trials. Control experiments showed more pronounced decline for NO + CO case, with appreciable intial (NO:Pd)molar value of 0.4 yet comparable-to-the-LTC-D-feed decline after 8 trials. CO-induced particle formation and larger extent of particle sintering was also evident from TEM analysis. Other controls did not exhibit trial-dependent deactivation as(NO:Pd)molar values were constant, at 0.3, 0.2, 0.5 and 0.2 for the NO, NO+H 2 , NO + unsaturated hydrocarbon (C 2 H 4 , C 3 H 6 ) and NO + saturated HC (C 3 H 8 , C 10 H 22 ) feeds respectively. In addition to these quantitative differences, desorption behaviors are qualitatively different. While only one major desorption event is observed for the full LTC-D, NO+ CO and NO+ unsaturated HC-controls, desorption occurs in two distinct stages for NO, NO + saturated HCs and initial-NO+H 2 trials. This arises due to inherent differences in Pd sites while exposed to these chemically distinct feeds. Furthermore, presence of reducing agents such as CO and unsaturated HCs in the feed result in almost complete elimination of lower, sub-200 °C desorption peak. The higher temperature desorption peaks, at > 300 °C is associated with NO strongly bound to ionic Pd sites and are prevalent under reducing conditions. Using DRIFTS also, three complexes leading to PNA are assigned, [O = N–Pd 2 +(OH)–Z], [O = N–Pd 2 +(Z2)] and [O = N–Pd 2 +(H 2 O)y–Z] with the latter being clearly observed upon water exposure. Pd/SSZ-13 showed higher hydrocarbon trapping than the SSZ-13 counterpart.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of 18 O Exchange on Neutron Emission Rates of Aging 238 PuO 2 LWRHUs

The Lightweight Radioisotope Heater Unit (LWRHU) provides about 1 Watt of thermal power to critical electrical and mechanical systems in the extreme temperatures of space, maintaining the operating temperature of the spacecraft’s scientific and general operating equipment. Los Alamos National Laboratory (LANL) designed and tested the LWRHU in the 1970s through early 1980s. The first production campaign at LANL was in the early 1980s in support of the Galileo mission in which over 100 LWRHUs were manufactured. In the mid-1990s, almost 200 LWRHUs were manufactured in support of the Cassini mission. After the primary Cassini manufacturing campaign, the Department of Energy (DOE) approved the fabrication of more than 10 additional LWRHUs as spares in 1998. The LWRHU assembly contains the following components: a fuel pellet, a vented capsule, a pyrolytic graphite insulator, and a fine-weave pierced fabric (FWPF) graphite aeroshell. The fuel pellet is a hot-pressed 238 PuO 2 cylindrical pellet that is sintered to create a ceramic pellet. The pellet is encapsulated in a platinum-rhodium encapsulation. The welded fueled clad is placed inside a pyrolytic graphite thermal insulation to protect the fuel from the heat produced in reentry events. The exterior layer of the LWRHU assembly is the FWPF aeroshell. Before sintering, PuO 2 granules are heated in a furnace at temperatures greater than or equal to 700°C under an enriched 16 O atmosphere in order to reduce trace quantities of 18 O. Because 18 O undergoes an (α,n) reaction, 18 O needs to be removed as much as possible to meet radiation emission requirements set by the Jet Propulsion Laboratory (JPL) and the National Aeronautics and Space Administration (NASA), as well as other agencies. The relative abundances of the oxygen isotopes are indicated by neutron emission rate (NER) measurements. LWRHUs are vented with a sintered platinum frit vent (George 1986). During extraterrestrial operation, the vent in the cladding allows helium from the decay of plutonium to escape and relieves pressure from the system while preventing the solids from escaping (Rinehart 1996, Tate 1982 & 1985). This vent is protected during manufacture by a platinum-30 rhodium cover. The capsule vent is activated by milling a 0.025-inch diameter hole through the protective cover to a nominal depth of 0.015 inches, generally immediately before the LWRHU is loaded into the aeroshell (George 1986). Prior to long-term storage, LWRHUs are vented and thus potentially allow infiltration of 18 O from the ambient atmosphere. Although NER decreases with age due to the reduction in emitted alpha particles, it might be expected that NER reduction is mitigated by the exchange of 18 O. However, this is not necessarily the case and no trend was observed relating NER to age other than the natural decay of 238 Pu (Mulford 2021). The most probable and dominant factor for determining specific NER was manufacturing discrepancies between individual units. It is important to understand the lack of observed 16 O- 18 O exchange and to compare LWRHU pellets as much as possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗