Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

Impedance studies of Ni/Cd and Ni/H cells using the cell case as reference electrode

Many impedance studies were carried out on Ni electrodes and Ni/Cd and Ni/H batteries. In order for impedance to become a diagnostic tool, accurate and reproducible measurements must be made, and some way of separating the contributions of the individual electrodes must be found. Using the PAR and the Solartron impedance equipment, studies have found that consistent measurements can be made if the cells or electrodes are equilibrated at the voltage of interest. In the charged state, equilibration times required are short, on the order of a few hours or less, but the equilibration time required becomes progessively longer as the voltage is lowered. The cell case can be used as a reference electrode during impedance measurements. The voltage of the case with respect to the electrodes is unimportant provided that it does not change appreciably during the course of the measurement. Measurements were made with several uncycled Ni/Cd cells, one from a lot which was known to have faulty Cd electrodes and another from a lot which showed excellent cycle life and presumably had good Cd electrodes. The impedances of the Ni electrodes vs. the case were similar, while the impedance of the poor Cd electrodes vs. the case. A 50 AH Ni/H cell was also investigated. After subtraction of the ohmic resistances, the sums of the impedances of the individual electrodes were very close to the impedance of the total cell. This indicates that the method is valid for examining the characteristics of the individual electrodes in situ.

Reid, Margaret A.↗

Phase-Modulation Gas-Correlation Spectroscopy

Electro-optic phase-modulation gas-correlation spectroscopy demonstrated in laboratory tests promising candidate technique for remote sensing of gases, temperatures, and wind velocities in atmosphere. In technique radiation emitted by sample atmosphere passed through electro-optic phase modulator, and modulated and unmodulated versions of spectrum alternately passed through reference absorption cell containing gas to be detected. Radiation emerging from reference cell band-pass filtered and detected. Correlation signal is difference in intensity between phase-modulated and unmodulated detected signals.

Rider, David M.↗

Interchange for Joint Research Entitled: Measurement of Stable Nitrogen and Sulfur Isotopes

Viking measurements of the Martian atmosphere indicate a value of N-15/N-14 which is markedly greater than that found in Earth's atmosphere. These isotopic measurements provide a powerful diagnostic tool which may be used to derive valuable information regarding the past history of Mars and they have been used to place important constraints on the evolution of Mars' atmosphere. Initial partial pressures of nitrogen, outgassing rates, and integrated deposition of nitrogen into minerals have been calculated from this important atmospheric data (McElroy et al., 1976 and 1977; Fox and Dalgarno, 1983). The greater precision obtained in laser spectrometer isotopic measurements compared to the Viking data will greatly improve these calculated values. It has also been proposed that the N-15/N-14 value in Mars' atmosphere has increased monotonically over time (McElroy et al., 1977; Fox and Dalgarno, 1983; Wallis, 1989) owing to preferential escape of atmospheric 14N to space. Nitrogen isotopic ratios might be used to identify relatively ancient crustal rocks (R. Mancinelli, personal communication), and perhaps determine relative aces of surface samples. As a first step in successfully measuring nitrogen isotopes optically we have demonstrated the measurement of 15NI14N to a precision of 0.1% (See Figures 1-4) using a tunable diode laser and an available gas (N-,O) with spectral lines in the 2188 cm-1 region. The sample and reference gas cells contained gases of identical isotopic composition so that the 15NI14N absorption ratio determined from the sample cell, when divided by the 15NI14N absorption ratio determined from the reference cell, should yield an ideal value of unity. The average measured value of this "ratio of ratios" was 0.9983 with a standard deviation (20 values) of 0.0010. This corresponds to a precision of 0.1% (1 per mil) for nitrogen isotopes, a value sufficiently precise to provide important isotopic data of interest to exobiologists. The precision presently attainable in gases is sufficient to permit the instrument to be used in the measurement of isotopic ratios of interest to exobiologists as well as geologists and planetary scientists.

Becker, Joseph F.↗

Silicon MINP solar cells

The MINP solar cell concept refers to a cell structure designed to be a base region dominated device. Thus, it is desirable that recombination losses are reduced to the point that they occur only in the base region. The most unique feature of the MINP cell design is that a tunneling contact is utilized for the metallic contact on the front surface. The areas under the collector grid and bus bar are passivated by a thin oxide of tunneling thickness. Efforts must also be taken to minimize recombination at the surface between grid lines, at the junction periphery and within the emitter. Results of both theoretical and experimental studies of silicon MINP cells are given. Performance calculations are described which give expected efficiencies as a function of base resistivity and junction depth. Fabrication and characterization of cells are discussed which are based on 0.2 ohm-cm substrates, diffused emitters on the order of 0.15 to 0.20 microns deep, and with Mg MIS collector grids. A total area AM 1 efficiency of 16.8% was achieved. Detailed analyses of photocurrent and current loss mechanisms are presented and utilized to discuss future directions of research. Finally, results reported by other workers are discussed.

Olsen, L. C.↗

Optical, structural, and chemical properties of flash evaporated In{sub 2}S{sub 3} buffer layer for Cu(In,Ga)Se{sub 2} solar cells

In{sub 2}S{sub 3} layers were deposited by flash evaporation technique with varying flash rates. The optical constants of layers based on Tauc-Lorentz model dielectric function were extracted from spectroscopic ellipsometry measurements. X-ray photoelectron spectroscopic investigation revealed the presence of oxygen impurity in as-deposited and air-annealed layers with traces of Na inclusion in the layer grown at high flash rate. The enhancement in crystalline arrangement of as-deposited layer after air annealing was confirmed by Raman spectroscopy. Rutherford backscattering measurements revealed the growth of off-stoichiometric layers at all flash rates. An analytical layer growth model has been proposed supporting the results obtained by various layer characterization techniques. The solar cells were prepared with flash evaporated In{sub 2}S{sub 3} buffer layers and their performances were compared with CdS reference solar cell. A significant gain in short-circuit current was obtained after air annealing of the complete device at 200 deg. C for 20 min. A maximum conversion efficiency of 12.6% was delivered by a high flash rate In{sub 2}S{sub 3} buffered cell with open-circuit voltage close to that of CdS reference cell. The improvement in device performance after air annealing treatment is explained by thermally enhanced Cu and oxygen diffusion from Cu(In,Ga)Se{sub 2} and i-ZnO to In{sub 2}S{sub 3} layer, respectively.

36 MATERIALS SCIENCE↗

Impedance studies of Ni/Cd and Ni/H2 cells using the cell case as a reference electrode

Impedance measurements have been made on several Ni/Cd and Ni/H2 flightweight cells using the case as a reference electrode. For these measurements the voltage of the case with respect to the anode or cathode is unimportant provided that it remains stable during the measurement of the impedance. In the cells measured so far, the voltages of the cell cases with respect to the individual electrodes differ from cell to cell even at the same overall cell voltage, but they remains stable with time. The measurements can thus be used to separate the cell impedance into the contributions of each electrode, allowing improved diagnosis of cell problems.

Reid, Margaret A.↗

Impedance studies of nickel/cadmium and nickel/hydrogen cells using the cell case as a reference electrode

Impedance measurements have been made on several Ni/Cd and Ni/H2 flight-weight cells using the case as a reference electrode. For these measurements, the voltage of the case with respect to the anode or cathode is unimportant provided that it remains stable during the measurement of the impedance. In the cells measured so far, the voltage of the cell cases with respect to the individual electrodes differ from cell to cell, even at the same overall cell voltage, but they remain stable with time. The measurements can thus be used to separate the cell impedance into the contributions of each electrode, allowing improved diagnosis of cell problems.

Reid, Margaret A.↗

Impact of dopant-induced optoelectronic tails on open-circuit voltage in arsenic-doped Cd(Se)Te solar cells

Fluctuations refer to inhomogeneity in the distribution of donors and acceptors at the nanometer scale and occur in many compound solar cell materials such as Cu(In,Ga)Se 2 , Cu 2 ZnSn(S,Se) 4 , and CdSe x Te 1-x . In this work, numerical simulations show that these fluctuations produce not only electrostatic potential variation, but also, local changes in the carrier density and effective bandgap. For a CdSe x Te 1-x absorber doped with arsenic, simulations and cathodoluminescence data within single grains demonstrate how donor and acceptor densities—consistent with capacitance-voltage and secondary-ion mass-spectrometry data—produce tails in photoluminescence, quantum efficiency, and absorption measurements. Using multiple theoretical approaches, we demonstrate that the fluctuations can hinder expected performance gains from increased carrier density, and we describe the significant open-circuit voltage deficit observed in the CdSe x Te 1-x :As solar technology. Our results demonstrate that it is critical to characterize and reduce carrier compensation to realize a higher efficiency.

14 SOLAR ENERGY↗

Results of the 1995 JPL balloon flight solar cell calibration program

The Jet Propulsion Laboratory (JPL) solar cell calibration program was conceived to produce reference standards for the purpose of accurately setting solar simulator intensities. The concept was to fly solar cells on a high-altitude balloon, to measure their output at altitudes near 120,000 ft (36.6 km), to recover the cells, and to use them as reference standards. The procedure is simple. The reference cell is placed in the simulator beam, and the beam intensity is adjusted until the reference cell reads the same as it read on the balloon. As long as the reference cell has the same spectral response as the cells or panels to be measured, this is a very accurate method of setting the intensity. But as solar cell technology changes, the spectral response of the solar cells changes also, and reference standards using the new technology must be built and calibrated. Until the summer of 1985, there had always been a question as to how much the atmosphere above the balloon modified the solar spectrum. If the modification was significant, the reference cells might not have the required accuracy. Solar cells made in recent years have increasingly higher blue responses, and if the atmosphere has any effect at all, it would be expected to modify the calibration of these newer blue cells much more so than for cells made in the past. JPL has been flying calibration standards on high-altitude balloons since 1963 and continues to organize a calibration balloon flight at least once a year. The 1995 flight was the 48th flight in this series. The 1995 flight incorporated 46 solar cell modules from 7 different participants. The payload included Si, amorphous Si, GaAs, GaAs/Ge, dual junction cells, top and bottom sections of dual junction cells, and a triple junction cell. A new data acquisition system was built for the balloon flights and flown for the first time on the 1995 flight. This system allows the measurement of current-voltage (I-V) curves for 20 modules in addition to measurement of modules with fixed loads as had been done in the past.

Anspaugh, B. E.↗

Analysis of SOFCs Using Reference Electrodes

Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

30 DIRECT ENERGY CONVERSION↗

Fast Charging of Li-Ion Cells: Part I. Using Li/Cu Reference Electrodes to Probe Individual Electrode Potentials

Increasing the charge rate of Li-ion cells over 1–2C (full charge in 30–60 min) would be highly desirable, but high currents flowing through the active materials push these cells to their endurance limits. In this article, we aim to understand how such high-current regimes affect electrochemical properties of the cells. Formation of Li metal deposits is a recognized hazard of high-rate charging, as Li plating can overtake lithium intercalation in the negative electrode. Here we demonstrate how microprobe Li/Cu reference electrodes can be used to characterize the graphite anode and layered oxide (NCM523) cathode during constant-current (≤ 6C) voltage-limited (4.39 V) charging of Li-ion cells. These reference electrodes are used to monitor the onset of Li plating conditions in situ during cell charging. As the current increases over 3C, the anode potentials decrease below -40 mV causing lithium nucleation. Surprisingly, this nucleation (at least, initially) does not result in capacity fade or a higher anode impedance even in strongly polarized cells, so it appears that the nascent Li nuclei are isolated from electrolyte by the pre-existing solid electrolyte interphase. Our study shows that microprobe reference electrodes are an important diagnostic tool to characterize full-cell behavior in the high-current regimes.

25 ENERGY STORAGE↗

Cell Wall Ultrastructure of Stem Wood, Roots, and Needles of a Conifer Varies in Response to Moisture Availability

The composition, integrity, and architecture of the macromolecular matrix of cell walls, collectively referred to as cell wall ultrastructure, exhibits variation across species and organs and among cell types within organs. Indirect approaches have suggested that modifications to cell wall ultrastructure occur in response to abiotic stress; however, modifications have not been directly observed. Glycome profiling was used to study cell wall ultrastructure by examining variation in composition and extractability of non-cellulosic glycans in cell walls of stem wood, roots, and needles of loblolly pine saplings exposed to high and low soil moisture. Soil moisture influenced physiological processes and the overall composition and extractability of cell wall components differed as a function of soil moisture treatments. The strongest response of cell wall ultrastructure to soil moisture was increased extractability of pectic backbone epitopes in the low soil moisture treatment. The higher abundance of these pectic backbone epitopes in the oxalate extract indicate that the loosening of cell wall pectic components could be associated with the release of pectic signals as a stress response. The increased extractability of pectic backbone epitopes in response to low soil moisture availability was more pronounced in stem wood than in roots or needles. Additional responses to low soil moisture availability were observed in lignin associated carbohydrates released in chlorite extracts of stem wood, including an increased abundance of pectic arabinogalactan epitopes. Overall, these results indicate that cell walls of loblolly pine organs undergo changes in their ultrastructural composition and extractability as a response to soil moisture availability and that cell walls of the stem wood are more responsive to low soil moisture availability compared to cell walls of roots and needles. In conclusion, to our knowledge, this is the first direct evidence, delineated by glycomic analyses, that abiotic stress affects cell wall ultrastructure. This study is also unique in that glycome profiling of pine needles has never before been reported.

54 ENVIRONMENTAL SCIENCES↗

Comparable Senescence Induction in Three-dimensional Human Cartilage Model by Exposure to Therapeutic Doses of X-rays or C-ions

Purpose: Particle therapy using carbon ions (C-ions) has been successfully used in the treatment of tumors resistant to conventional radiation therapy. However, the potential side effects to healthy cartilage exposed to lower linear energy transfer (LET) ions in the beam track before the tumor have not been evaluated. The aim of the present study was to assess the extent of damage after C-ion irradiation in a 3-dimensional (3D) cartilage model close to human homeostasis. Methods and Materials: Primary human articular chondrocytes from a healthy donor were cultured in a collagen scaffold to construct a physioxic 3D cartilage model. A 2-dimensional (2D) culture was used as a reference. The cells were irradiated with a single dose of a monoenergetic C-ion beam with a LET of approximatively 30 keV/μm. This LET corresponds to the entrance channel of C-ions in the shallow healthy tissues before the spread-out Bragg peak (∼100 keV/μm) during hadron therapy protocols. The same dose of X-rays was used as a reference. Survival, cell death, and senescence assays were performed. Results: As expected, in the 2D culture, C-ions were more efficient than X-rays in reducing cell survival with a relative biological effectiveness of 2.6. This correlated with stronger radiation-induced senescence (two-fold) but not with higher cell death induction. This differential effect was not reflected in the 3D culture. Both ionizing radiation types induced a comparable rate of senescence induction in the 3D model. Conclusions: The greater biological effectiveness of C-ions compared with low LET radiation when evaluated in treatment planning systems might be misevaluated using 2D culture experiments. Radiation-induced senescence is an important factor of potential cartilage attrition. The present data should encourage the scientific community to use relevant models and beams to improve the use of charged particles with better safety for patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Magnetite Nanoparticles and Quantum Dots on the Expression of Reference Genes in Peripheral Blood Cells

We studied the influence of magnetite nanoparticles (FeO•Fe{sub 2}O{sub 3}) and quantum dots (CdSe/ZnS coated with mercaptopropionic acid) on the expression of 5 common reference genes (BA, B2M, PPIA, UBC, and YWHAZ) in peripheral blood cells from 20 volunteers by reverse transcription PCR method. The stability of the expression of reference genes varied depending of the cells type and chemical structure of nanoparticles. The level of YWHAZ mRNA after exposure by nanoparticles demonstrated highest stability in lymphocytes, neutrophils, and monocytes. Stability of YWHAZ expression was confirmed by Western blotting. Our findings suggest that YWHAZ is the most suitable as the reference gene.

60 APPLIED LIFE SCIENCES↗

Device for monitoring cell voltage

A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

47 OTHER INSTRUMENTATION↗

The Effect of Electrolyte Composition on Lithium Plating During Low Temperature Charging of Li-Ion Cells

In the present work, a number of additives have been investigated for their effect on the charge characteristics of cells containing low temperature, high ester content electrolytes (1.0 M LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC) + methyl propionate (MP) 20:20:60 vol % + X additive). These experimental three-electrode cells are composed of graphite anodes, LiNiCoAlO2 cathodes, and a lithium metal reference electrode. Cells were first subjected to electrochemical characterization at various temperatures, consisting of performing Electrochemical Impedance Spectroscopy (EIS), linear micropolarization and Tafel polarization measurement to determine the kinetic parameters for both the anodes and cathodes. Following electrochemical characterization, the cells were subjected to charging at decreasing temperatures using C/5 rates to 4.10V, with a constant potential C/50 current taper. Analysis of the C/20 discharge following the charge at low temperature revealed either the presence or absence of a high voltage plateau during the initial stages of the discharge. This plateau has been linked to the presence of lithium metal on the anode previously and was used as a measure for the extent of lithium plating in the cell. Differential analysis (dV/dQ) was applied as well to more clearly visualize the position of the high voltage plateau and use the peak position (x-axis) in the dV/dQ plot as a gauge for the amount of plating which took place in the cell on the prior charge. Most additives investigated increased the resistance of the anode and decreased the resistance of the cathode, thereby leading to an overall increase in plating observed at low temperature. One additive, LiFSI, was found to be beneficial during low temperature charging, however studies of electrode kinetics from the cell containing LiFSI did not reveal significant improvements compared to the baseline.

Jones, John-Paul↗