Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fiberoptics technology and its application to propulsion control systems

Current work on optical sensors and optically controlled actuators for use in air-breathing engine control systems is reviewed with particular reference to the design and operation of several new fiber-optic devices. These include a tachometer, a rotary position encoder, a Fabry-Perot interferometer and a rare-earth sensor for measuring engine gas temperatures, a high-temperature photoswitch designed for the range -55 to 260 C, and optical cables and connectors. The advantages of optics over conventional wire systems used for sensing and actuator control are briefly discussed.

Baumbick, R. J.↗

Silicon MINP solar cells

The MINP solar cell concept refers to a cell structure designed to be a base region dominated device. Thus, it is desirable that recombination losses are reduced to the point that they occur only in the base region. The most unique feature of the MINP cell design is that a tunneling contact is utilized for the metallic contact on the front surface. The areas under the collector grid and bus bar are passivated by a thin oxide of tunneling thickness. Efforts must also be taken to minimize recombination at the surface between grid lines, at the junction periphery and within the emitter. Results of both theoretical and experimental studies of silicon MINP cells are given. Performance calculations are described which give expected efficiencies as a function of base resistivity and junction depth. Fabrication and characterization of cells are discussed which are based on 0.2 ohm-cm substrates, diffused emitters on the order of 0.15 to 0.20 microns deep, and with Mg MIS collector grids. A total area AM 1 efficiency of 16.8% was achieved. Detailed analyses of photocurrent and current loss mechanisms are presented and utilized to discuss future directions of research. Finally, results reported by other workers are discussed.

Olsen, L. C.↗

Mechanical control of airplanes

Before undertaking a detailed description of an automatic-control mechanism, I will state briefly the fundamental conditions for such devices. These are: 1) it must be sensitive at one or more reference values; 2) it must stop the angular motions of the airplane not produced by the pilot; and 3) it must be possible to switch it off and on by a simple hand lever.

AUTOMATIC PILOTS - BOYKOW↗

Ultrasonic Apparatus and Technique to Measure Changes in Intracranial Pressure

Changes in intracranial pressure can be measured dynamically and non-invasively by monitoring one or more cerebrospinal fluid pulsatile components. Pulsatile components such as systolic and diastolic blood pressures are partially transferred to the cerebrospinal fluid by way of blood vessels contained in the surrounding brain tissue and membrane. As intracranial pressure varies these cerebrospinal fluid pulsatile components also vary. Thus, intracranial pressure can be dynamically measured. Furthermore, use of acoustics allows the measurement to be completely non-invasive. In the preferred embodiment, phase comparison of a reflected acoustic signal to a reference signal using a constant frequency pulsed phase-locked-loop ultrasonic device allows the pulsatile components to be monitored. Calibrating the device by inducing a known change in intracranial pressure allows conversion to changes in intracranial pressure.

William T Yost↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities

Emrich, William J. Jr.↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Phase II Upgrade Activities

To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities. Keywords: Nuclear Thermal Propulsion, Simulator

Emrich, William J.↗

Initial Operation and Shakedown of the Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Prototypical fuel elements mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission in addition to being exposed to flowing hydrogen. Recent upgrades to NTREES now allow power levels 24 times greater than those achievable in the previous facility configuration. This higher power operation will allow near prototypical power densities and flows to finally be achieved in most prototypical fuel elements.

Emrich, William J., Jr.↗

Flexible manufacturing for photonics device assembly

The assembly of photonics devices such as laser diodes, optical modulators, and opto-electronics multi-chip modules (OEMCM), usually requires the placement of micron size devices such as laser diodes, and sub-micron precision attachment between optical fibers and diodes or waveguide modulators (usually referred to as pigtailing). This is a very labor intensive process. Studies done by the opto-electronics (OE) industry have shown that 95 percent of the cost of a pigtailed photonic device is due to the use of manual alignment and bonding techniques, which is the current practice in industry. At Lawrence Livermore National Laboratory, we are working to reduce the cost of packaging OE devices through the use of automation. Our efforts are concentrated on several areas that are directly related to an automated process. This paper will focus on our progress in two of those areas, in particular, an automated fiber pigtailing machine and silicon micro-technology compatible with an automated process.

Lu, Shin-Yee↗

Summary of the NASA Semi-Span High-Lift Common Research Model Wind Tunnel Test at the QinetiQ 5-Metre Low-Speed Facility

A summary and selected results from experimental testing of the NASA 10% scale semi-span High-Lift Common Research Model (CRM-HL) at the QinetiQ 5m (5mWT) pressurized low-speed wind tunnel are presented. There were many objectives of this test, the primary being to define a set of reference configurations for dissemination and use within the CRM-HL ecosystem, one in the landing configuration and one in the takeoff configuration. A database of force, moment, pressure and surface flow visualization data was collected to support several objectives: aerodynamic sensitivity to high-lift device positioning, Reynolds number effects on configuration selection, isolation of the effects of various components of the reference configuration e.g. landing gear, nacelle, horizontal tail, etc., and limited repeatability data for uncertainty quantification assessment. Some results were compared to limited data collected at the NASA Langley Research Center 14x22 wind tunnel to assess half-model effects and facility differences. Half-model effects were further studied with use of floor blowing to change boundary layer profile and assess effects on model aerodynamics. Flow visualization data were gathered with fluorescent mini-tufts and UV oil. Finally, test time was spend working on the development of new Particle Image Velocimetry (PIV) and Model Deformation Measurement (MDM) capabilities at the 5mWT facility.

Ashley Evans↗

Two-axis leveling detector system

Electro-mechanical device for measuring tilt angles in order to establish level base without optical reference is described. Angular displacement is detected by movement of bubble in conducting fluid containing electrode network. Electrical signal causes compensation for small movements in horizontal and vertical planes.

Weiner, L.↗

Temperature reference for microwave radiometer calibration

New temperature reference avoids need to physically remove antenna and replace it with calibrating termination. Device is piece of porous microwave absorber fitted with cap of nonporous plastic foam. Absorbent material is soaked with cryogen. Procedure ensures that temperature at which microwaves are absorbed is exactly that of cryogen.

Love, A. W.↗

Real-time Adaptive Control Using Neural Generalized Predictive Control

The objective of this paper is to demonstrate the feasibility of a Nonlinear Generalized Predictive Control algorithm by showing real-time adaptive control on a plant with relatively fast time-constants. Generalized Predictive Control has classically been used in process control where linear control laws were formulated for plants with relatively slow time-constants. The plant of interest for this paper is a magnetic levitation device that is nonlinear and open-loop unstable. In this application, the reference model of the plant is a neural network that has an embedded nominal linear model in the network weights. The control based on the linear model provides initial stability at the beginning of network training. In using a neural network the control laws are nonlinear and online adaptation of the model is possible to capture unmodeled or time-varying dynamics. Newton-Raphson is the minimization algorithm. Newton-Raphson requires the calculation of the Hessian, but even with this computational expense the low iteration rate make this a viable algorithm for real-time control.

Haley, Pam↗

System for In-Situ Detection of Plant Exposure to Trichloroethylene (TCE)

A system detects a plant's exposure to trichloroethylene (TCE) through plant leaf imaging. White light impinging upon a plant's leaf interacts therewith to produce interacted light. A detector is positioned to detect at least one spectral band of the interacted light. A processor coupled to the detector performs comparisons between photonic energy of the interacted light at the one or more spectral bands thereof and reference data defining spectral responses indicative of leaf exposure to TCE. An output device coupled to the processor provides indications of the comparisons.

Lewis, Mark D.↗

Irradiation with molecular hydrogen as an accelerated total dose hardness assurance test method for bipolar linear circuits

High dose rate irradiation with hydrogen stress is proposed as an accelerated total dose test method for bipolar linear circuits. The method is validated across process and circuit technologies with five parts that are commonly used in space: a comparator (LM193 from National Semi-conductor), a voltage regulator (HSYE-117 RH from Intersil), a voltage reference (LT1019 from Linear Technology), a JFET input op amp (OP42 from Analog Devices) and a temperature transducer (AD590 from Analog Devices). The testing technique could rapidly establish an upper bound to the low dose rate response of parts in space and help with the part selection process in the design phase of a mission. The technology dependence and the viability of this technique are qualitatively explored using a physical model describing the dose rate response and the effect of hydrogen in bipolar technologies. The model uses four core processes: 1) space charge effects, 2) free electron/hole pair recombination, hole-hydrogen defect reactions in the oxides and 4) proton depassivation of dangling bonds at the Si/SiO2 interface. Radiation hardness assurance implications are discussed.

Pease, Ron↗

Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars

The Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2024 Academic Innovation Challenge features a project titled “Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars”. The project calls for the development of prototype IDEIs “that could be used for implementing integrated system health management for Crew Health and Performance (CHP) required for crew living on Mars for extended periods of time”. Thus, the deliverable for the project is not only a prototype exercise device, but also an ontology that provides insight into the best ways to exercise on Mars. To that end, we on the BLiSS team, supported by advisors from industry and academia, set out to ideate an exercise ontology and demonstrate its effectiveness through a functional prototype. To achieve the stakeholders’ requests, the device must operate semi-autonomously, must be an analog for an extant exercise device on Earth, and must provide quantitative information about the exercise and the device’s own state of health. Here, we define “semi-autonomous” as referring to the fact that while the system should be as autonomous as possible, there are some processes that the system cannot fulfill on its own. These include, but are not limited to, user identification, physical exercise reconfiguration, and wearable sensor placement.

llyana Smith↗

Calibrating a 3-Axis Accelerometer Instrument with a Less Accurate Calibration Device Part 1: Mathematical Methodology

A three-axis accelerometer instrument (3xAI) can provide the angular attitude of a 3D object using the gravity vector (g) as the sole reference. Calibrating such an instrument requires placing it at known (to some accuracy plus uncertainty) angular articulations with respect to g. This paper will show a potential process for calibrating a 3xAI by using a 2-axis rotary system (calibration device) to provide these articulations. Any calibration device (CD) with such capacity will contain internal misalignments. These misalignments, even if made relatively small or approximated to zero in the kinematics model (KM), can be detrimental to the calibration of the instrument when high measurement accuracy is required. This is especially true if the selected set of articulations chosen for calibration do not include their symmetrical counterpoints (a point where the misalignment has equal magnitude but is opposite in direction to a point chosen). The consequence of not including the combination, point and counterpoint, for any misalignment involved in the calibration, results in a biased instrument. This paper will demonstrate a calibration of the instrument using symbolic math resulting in a closed-form solution of the instrument coefficients. The main objective is to show the impact of all the CD misalignments to the instrument coefficients. This process is the basis for a more sophisticated method (shown in a future paper) for obtaining the instrument coefficients while simultaneously obtaining an estimate of the calibration device internal misalignments.

Angle↗

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗