Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Characteristics of Coplanar Waveguide on Sapphire for High Temperature Applications (25 to 400 degrees C)

This paper presents the characteristics of coplanar waveguide transmission lines fabricated on R-plane sapphire substrates as a function of temperature across the temperature range of 25 to 400 C. Effective permittivity and attenuation are measured on a high temperature probe station. Two techniques are used to obtain the transmission line characteristics, a Thru-Reflect-Line calibration technique that yields the propagation coefficient and resonant stubs. To a first order fit of the data, the effective permittivity and the attenuation increase linearly with temperature.

Ponchak, George E.↗

High Temperature Characteristics of Coplanar Waveguide on R-Plane Sapphire and Alumina

This paper presents the characteristics of coplanar waveguide transmission lines on R-plane sapphire and alumina over the temperature range of 25 to 400 C and the frequency range of 45 MHz to 50 GHz. A Thru-Reflect-Line calibration technique and open circuited terminated stubs are used to extract the attenuation and effective permittivity. It is shown that the effective permittivity of the transmission lines and, therefore, the relative dielectric constant of the two substrates increase linearly with temperature. The attenuation of the coplanar waveguide varies linearly with temperature through 200 C, and increases at a greater rate above 200 C.

Ponchak, George E.↗

Characteristics of Coplanar Waveguide on Sapphire for High Temperature Applications (25 to 400 C)

This paper presents the characteristics of coplanar waveguide transmission lines fabricated on R-plane sapphire substrates as a function of temperature across the temperature range of 25 to 400 C. Effective permittivity and attenuation are measured on a high temperature probe station. Two techniques are used to obtain the transmission line characteristics, a Thru-Reflect-Line calibration technique that yields the propagation coefficient and resonant stubs. To a first order fit of the data, the effective permittivity and the attenuation increase linearly with temperature

Ponchak, George E.↗

Estuarine Sediment Deposition during Wetland Restoration: A GIS and Remote Sensing Modeling Approach

Restoration of the industrial salt flats in the San Francisco Bay, California is an ongoing wetland rehabilitation project. Remote sensing maps of suspended sediment concentration, and other GIS predictor variables were used to model sediment deposition within these recently restored ponds. Suspended sediment concentrations were calibrated to reflectance values from Landsat TM 5 and ASTER using three statistical techniques -- linear regression, multivariate regression, and an Artificial Neural Network (ANN), to map suspended sediment concentrations. Multivariate and ANN regressions using ASTER proved to be the most accurate methods, yielding r2 values of 0.88 and 0.87, respectively. Predictor variables such as sediment grain size and tidal frequency were used in the Marsh Sedimentation (MARSED) model for predicting deposition rates for three years. MARSED results for a fully restored pond show a root mean square deviation (RMSD) of 66.8 mm (<1) between modeled and field observations. This model was further applied to a pond breached in November 2010 and indicated that the recently breached pond will reach equilibrium levels after 60 months of tidal inundation.

Newcomer, Michelle↗

Suomi-NPP VIIRS Solar Diffuser Stability Monitor Performance

When illuminated by the Sun, the onboard solar diffuser (SD) panel provides a known spectral radiance source to calibrate the reflective solar bands of the Visible Infrared Imaging Radiometer Suite on the Suomi-NPP satellite. The SD bidirectional reflectance distribution function (BRDF) degrades over time due to solar exposure, and this degradation is measured using the SD stability monitor (SDSM). The SDSM acts as a ratioing radiometer, comparing solar irradiance measurements off the SD panel to those from a direct Sun view. We discuss the design and operations of the SDSM, the SDSM data analysis, including improvements incorporated since launch, and present the results through 1000 days after launch. After 1000 days, the band-dependent H-factors, a quantity describing the relative degradation of the BRDF of the SD panel since launch, range from 0.716 at 412 nanometers to 0.989 at 926 nanometers. The random uncertainty of these H-factors is about 0.1 percent, which is confirmed by the similar standard deviation values computed from the residuals of quadratic exponential fits to the H-factor time trends. The SDSM detector gains have temperature sensitivity of up to about 0.36 percent per kelvin, but this does not affect the derived H-factors. An initial error in the solar vector caused a seasonal bias to the H-factors of up to 0.5 percent. The total exposure of the SD panel to UV light after 1000 orbits is equivalent to about 100 hours of direct sunlight illumination perpendicular to the SD panel surface.

Fulbright, Jon↗

Surface Roughness-Induced Spectral Degradation of Multi-Spaceborne Solar Diffusers Due to Space Radiation Exposure

Solar diffusers (SDs) have often been used as the onboard calibrators for the radiometric calibration of reflective solar band imaging sensors. After being spaceborne, the reflectance of SDs is observed to degrade with spectral dependence due to exposure to solar UV and energetic particle radiation. Long-term spectral reflectance data of SDs onboard multiple LEO imaging sensors, such as the Moderate Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua and the Visible Infrared Imaging Radiometer Suite (VIIRS) on SNPP, are analyzed. The reflectance of SDs on these three instruments degrades faster for the shorter wavelength (0.4-0.6 μm) bands than the longer wavelength bands. The Surface Roughness-induced Rayleigh Scattering (SRRS) model is applied to simulate the SD degradation on these instruments, and the growth of the surface roughness parameter of the SDs is derived. It is determined that the change of surface roughness scale length is ~tens of nanometers. To show the consistency of roughness growth rates among the SDs on Terra/Aqua MODIS and SNPP VIIRS instruments, the functional dependences of the growth rates are characterized according to the SD exposure time and the stage of surface roughness. It is also found that the flattening or reverse in the growth trend of the surface roughness for these three SDs occurred around the same interval between October 2013 and October 2015. The confirmation of the applicability of SRRS model with the long-term spectral reflectance data from three independent spaceborne SDs facilitates a better understanding of the origin and physical processes of the SD degradation.

Visible Infrared Imaging Radiometer Suite (VIIRS)↗

Bearing Anomaly for the Sentinel 6 Supplemental Calibration System

The Supplemental Calibration System (SCS) was designed to rotate an elliptical reflector for the Sentinel 6 Advanced Microwave Radiometer (AMR). By rotating the reflector, the system can perform calibrations by comparing the reflection from space to the reflection from an onboard calibration target. During the qualification testing of the SCS, a flaw was discovered that resulted in apparent brinelling of bearings that support the rotating reflector. An extensive investigation ensued to determine the root cause of the problem. Though the most likely root causes of the presumed brinelling ended up being the result of undersized bearing clamp rings and thermal mismatch, there were requirements that drove these design choices. This paper describes the design of the bearing assembly, requirements that drove the design, and documents a challenging investigation filled with ambiguous test results.

Paulsen, Gale↗

Bearing Anomaly for the Sentinel 6 Supplemental Calibration System

The Supplemental Calibration System (SCS) was designed to rotate an elliptical reflector for the Sentinel 6 Advanced Microwave Radiometer (AMR). By rotating the reflector, the system can perform calibrations by comparing the reflection from space to the reflection from an onboard calibration target. During the qualification testing of the SCS, a flaw was discovered that resulted in apparent brinelling of bearings that support the rotating reflector. An extensive investigation ensued to determine the root cause of the problem. Though the most likely root causes of the presumed brinelling ended up being the result of undersized bearing clamp rings and thermal mismatch, there were requirements that drove these design choices. This paper describes the design of the bearing assembly, requirements that drove the design, and documents a challenging investigation filled with ambiguous test results.

Paulsen, Gale↗

JPSS J2 Spectralon Performance Prelaunch

Spectralon® is a high reflectance excellent diffuser used to reflect sunlight for use as a calibrator for on-orbit and ground instruments. Radiometric calibration of the reflective bands in the 0.4 to 2.5μm wavelength range is performed by measuring the sunlight reflected from Spectralon®. Reflected sunlight is directly proportional to the Bidirectional Reflectance Distribution Function (BRDF) of the Spectralon®. On-orbit exposure to sunlight results in solarization due to solar UV and the presence of residual contamination. Spectralon® quality is checked at start of build by measuring the change in reflectance on exposing a witness sample to 100 hours Solar UV as an indication of on orbit performance. For JPSS J2, the witness samples accompanied the sensor till 30 days before launch. Measuring the reflectance change on exposure to Solar UV of the witness samples accompanying the sensor through build and test is a better indication of on orbit performance as this includes any additional contamination during the build and test phase.

spectral reflectance↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Positional Dependence of SNPP VIIRS Solar Diffuser BRDF Change Factor: An Empirical Approach

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs), primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, quantified by a numerical factor called the H-factor, is determined by the onboard SD stability monitor. Our previous study showed that the H-factor is solar angle and view direction dependent. In this study, we determine the dependence of the H-factor on the detector SD view footprint location. We fit an empirical model to the NASA Collection 1 SNPP VIIRS Level 1B (L1B) spectral reflectance difference across the detectors in an RSB over uniform Earth scenes of the Libya 4 desert and deep convective clouds. We apply the model predicted SD positional dependent H-factor to calibrate the RSBs. Under this new calibration scheme, the original unreal striping is removed from the homogeneous Libya 4 desert and the deep convective cloud images, as well as the original unreal striping from the Dunhuang desert image. The SD positional dependent H-factor has been used to calculate the SNPP VIIRS RSB radiometric correction factor for the NASA Collection 2.0 SNPP VIIRS L1B products.

SNPP VIIRS↗

Evaluation of GLAMR-Based Calibration for SI-Traceable Field Reflectance Retrievals

The reflected solar instrument that is part of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is being formulated with a goal of providing SI-traceable measurement of radiance that is an order of magnitude more accurate than the current imaging sensors. The Goddard Laser for Absolute Measurement of Radiance (GLAMR) is a key element to reaching such accuracy along with transferring the laboratory calibration to on-orbit measurements. Results from field reflectance retrievals using three separate instruments all of which have been calibrated using GLAMR are shown. The instruments include a commercial field spectrometer and a portable version of CLARREO's calibration demonstration system. The third instrument is NASA Goddard's Lidar, Hyperspectral and Thermal Imager (G-LiHT) which is an airborne system. All three were operated during a March 2013 measurement campaign at Red Lake Playa, Arizona as part of the on-orbit commissioning phase of Landsat 8. Reflectance is derived from near-coincident measurements by the three sensors for a small area of the playa. The retrieved results are SI-traceable and demonstrate the ability to transfer the GLAMR calibration to the field. Use of the G-LiHT data in the calibration of Landsat-7 and -8 sensors permits them both to be placed on the GLAMR-scale as well.

Angal, Amit↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Inflight radiometric calibration and the determination of surface reflectance

The inflight radiometric performance of AVIRIS is presented together with a comparison of methods of recovering surface spectral reflectance from the data. Performance is evaluated by comparing radiance predicted from AVIRIS with radiance generated from the LOWIRAN 6 atmospheric model and measured surface reflectance. Comparisons show apparent agreement to within a few percent between 1800 and 2450 nm. Between 600 and 1800 nm the response of AVIRIS is systematically low by as much as 70 percent, and between 400 and 600 nm it is higher than expected. These problems are traced to thermal distortions of the instrument, and to detachment during flight of optical fibers connecting foreoptics to two of four spectrometers in the instrument. Of three methods studied, an empirical one involving calibration curves constructed from field reflectance measurements returns accurate predictions of the surface reflectance independent of the actual radiometric significance of the flight data.

Conel, J. E.↗

Experimental study of wall boundary layer growth in the 10 deg half angle conical nozzle of a reflected shock tunnel

Calibration studies of shock-tunnel nozzle flow were made in both N2 and Ar for a reservoir temperature of 2000 deg K and reservoir pressures of 15, 85, and 130 atm. The results for both test gases showed that the boundary layer was turbulent and the growth nonlinear, with the thickness being greater in Ar than N2 at comparable reservoir conditions. The boundary-layer thickness decreased with increasing reservoir pressure, but only small differences occurred between the two largest reservoir pressures. Good correlations of the boundary layer and displacement thickness were obtained for both N2 and Ar in terms of Reynolds number based on a reference temperature.

Menees, G. P.↗

On-Orbit Calibration and Performance of NOAA-20 VIIRS Reflective Solar Bands

The NOAA-20 (N20) satellite was launched on November 18, 2017 carrying the second Visible Infrared Imaging Radiometer Suite (VIIRS) instrument. Immediately following the launch, the VIIRS passed a series of intensive calibration and validation tests, after which regular calibration and operation activities have continued successfully for more than three years. The production of NASA Collection 2 Level 1B (C2 L1B) for N20 VIIRS began in summer 2019. In this article, we evaluate the early mission performance of the N20 VIIRS reflective solar bands (RSB) covering the first three full years of operation. The calibrated RSB gains are calculated primarily from the onboard solar diffuser (SD) and used in generating the C2 L1B reflectance and radiance products. We also show the on-orbit performance of the instrument noise, signal-to-noise ratio (SNR), and a reflectance uncertainty assessment. Comparisons are made to the first three years of operation of the first VIIRS instrument, aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. We evaluate the long-term stability of the calibrated N20 RSB reflectance product by looking at the long-term trends of lunar observations and data from the pseudo-invariant Libya 4 desert site. The N20 RSB have had excellent early mission performance, with changes in the gain of less than 0.5% in the first three years across all detectors, stable L1B reflectance, and very stable values of detector SNR and reflectance uncertainty.

calibration↗

Spectroradiometric considerations for advanced land observing systems

Research aimed at improving the inflight absolute radiometric calibration of advanced land observing systems was initiated. Emphasis was on the satellite sensor calibration program at White Sands. Topics addressed include: absolute radiometric calibration of advanced remote sensing; atmospheric effects on reflected radiation; inflight radiometric calibration; field radiometric methods for reflectance and atmospheric measurement; and calibration of field relectance radiometers.

Slater, P. N.↗