At least 181 records · Page 10

Advancing Launch Readiness of the Europa Light Microscope

The search for life in our solar system relies on our ability to measure key biomarkers in situ and identify them as likely of biotic origin. One class of biomarkers that would be indicative of life is cell-like features such as the colocalization of key biochemicals, spatial organization of native UV fluorescent compounds, and polarization across membrane compartments. The Europa Lander Science Definition Team has emphasized the need for a light microscope to search for these features on Europa, and the Europa Light Microscope (ELM) has been developed to address this need. This work presents the development towards high launch readiness of ELM by demonstrating its optical resolution under brightfield illumination, deep UV fluorescence imaging of unstained living samples, and multicolor imaging of samples stained with exogenous fluorophores targeting proteins, lipids, and nucleic acids. This work also seeks to extend the capabilities of ELM by incorporating fluorescence-based assays for membrane potential as a key biomarker for living cellular material.

Pavel Erich Zivanovic Klier↗

A Dynamic Landslide Hazard Monitoring Framework for the Lower Mekong Region

The Lower Mekong region is one of the most landslide-prone areas of the world. Despite the need for dynamic characterization of landslide hazard zones within the region, it is largely understudied for several reasons. Dynamic and integrated understanding of landslide processes requires landslide inventories across the region, which have not been available previously. Computational limitations also hamper regional landslide hazard assessment, including accessing and processing remotely sensed information. Finally, open-source software and modelling packages are required to address regional landslide hazard analysis. Leveraging an open-source data-driven global Landslide Hazard Assessment for Situational Awareness model framework, this study develops a region-specific dynamic landslide hazard system leveraging satellite-based Earth observation data to assess landslide hazards across the lower Mekong region. A set of landslide inventories were prepared from high-resolution optical imagery using advanced image-processing techniques. Several static and dynamic explanatory variables (i.e., rainfall, soil moisture, slope, relief, distance to roads, distance to faults, distance to rivers) were considered during the model development phase. An extreme gradient boosting decision tree model was trained for the monsoon period of 2015–2019 and the model was evaluated with independent inventory information for the 2020 monsoon period. The model performance demonstrated considerable skill using receiver operating characteristic curve statistics, with Area Under the Curve values exceeding 0.95. The model architecture was designed to use near-real-time data, and it can be implemented in a cloud computing environment (i.e., Google Cloud Platform) for the routine assessment of landslide hazards in the Lower Mekong region. This work was developed in collaboration with scientists at the Asian Disaster Preparedness Center as part of the NASA SERVIR Program’s Mekong hub. The goal of this work is to develop a suite of tools and services on accessible open-source platforms that support and enable stakeholder communities to better assess landslide hazard and exposure at local to regional scales for decision making and planning.

Nishan Kumar Biswas↗

South Africa Ecological Conservation: Identifying and Mapping Riparian Areas in South Africa with Earth Observations

Riparian zones are thin strips of wetland that occur along the edges of rivers, lakes, and other water bodies. They provide many ecosystem and societal benefits such as stream bank stabilization, flood control, and habitat stability, making these zones very important areas to preserve and protect. Recognizing the need to accurately map these ecosystems in a cost-effective way, we partnered with the South African National Biodiversity Institute (SANBI) and the Biodiversity Survey of the Cape(BioSCape) to develop a GI methodology using Esri's ArcGIS Pro and data from Landsat 9 Operational Land Imager-2, Sentinel-2 Multispectral Instrument, and the Shuttle Radar Topography Mission to identify potential riparian zones (PRZ) and observed riparian vegetation(ORV) in the Southern Cape and the North West Province of South Africa to estimate the actual riparian vegetation (ARV) within those areas. Potential riparian ecosystems were calculated by utilizing a Topographic Wetness Index (TWI) and a water feature layer, while observed riparian vegetation were calculated by overlaying a Normalized Difference Vegetation Index (NDVI) and TWI. Actual Riparian Vegetation is determined by the overlap of ORV with PRZ and is done with conditional statements; ORV within PRZ is ARV. This method significantly improved a current riparian land cover classification since it combined high resolution optical imagery and topographic data. We anticipate such maps will be used by conservationists and practitioners interested in riparian monitoring and management.

Remote Sensing↗

Resolution of a target-tracking optical novelty filter

The resolution of a target-tracking optical novelty filter is discussed in terms of the response time of the nonlinear medium, the speed of the target, and the resolution of the input device. Optical novelty filters using a faster nonlinear medium may have a higher output resolution. This is particularly true in the case of tracking high-speed targets. The potential of implementing high-resolution optical novelty filters using photorefractive GaAs is investigated experimentally.

Liu, Duncan T. H.↗

Monocrystalline Silicon and the Meta-Shell Approach to Building X-Ray Astronomical Optics

Angular resolution and photon-collecting area are the two most important factors that determine the power of an X-ray astronomical telescope. The grazing incidence nature of X-ray optics means that even a modest photon-collecting area requires an extraordinarily large mirror area. This requirement for a large mirror area is compounded by the fact that X-ray telescopes must be launched into, and operated in, outer space, which means that the mirror must be both lightweight and thin. Meanwhile the production and integration cost of a large mirror area determines the economical feasibility of a telescope. In this paper we report on a technology development program whose objective is to meet this three-fold requirement of making astronomical X-ray optics: (1) angular resolution, (2) photon-collecting area, and (3) production cost. This technology is based on precision polishing of monocrystalline silicon for making a large number of mirror segments and on the meta-shell approach to integrate these mirror segments into a mirror assembly. The meta-shell approach takes advantage of the axial or rotational symmetry of an X-ray telescope to align and bond a large number of small, lightweight mirrors into a large mirror assembly. The most important features of this technology include: (1) potential to achieve the highest possible angular resolution dictated by optical design and diffraction; and (2) capable of implementing every conceivable optical design, such as Wolter-I, Wolter-Schwarzschild, as well as other variations to one or another aspect of a telescope. The simplicity and modular nature of the process makes it highly amenable to mass production, thereby making it possible to produce very large X-ray telescopes in a reasonable amount of time and at a reasonable cost. As of June 2017, the basic validity of this approach has been demonstrated by finite element analysis of its structural, thermal, and gravity release characteristics, and by the fabrication, alignment, bonding, and X-ray testing of mirror modules. Continued work in the coming years will raise the technical readiness of this technology for use by SMEX, MIDEX, Probe, as well as major flagship missions.

Zhang, William W.↗

Optical pulse timing resolution

This correspondence evaluates the performance of the maximum likelihood (ML) and several suboptimal arrival time estimators for optical pulses. The performance analysis of a 'sliding window' counter followed by a threshold detector is achieved by deriving an expression for the first-crossing density of the output of the counter.

Lee, G.↗

A comparison of high-resolution radio and optical data for the northeast region of the Cygnus Loop

Radio observations of the northeastern part of the Cygnus Loop obtained with the VLA at 18 cm with a resolution of 4.7 arcsec are presented and discussed. In general, the brightest radio filaments match the brightest optical filaments very well, particularly those which are bright in H-alpha. The agreement in position, morphology, and relative brightness is particularly good where all four optical species are bright. However, a few bright radio features have no bright optical counterparts. The general radio and optical structure of the region can be explained by a model in which shocked interstellar clouds form filaments due to unstable cooling and compression. The features appear to be ropelike, although it is not possible to rule out that they are irregular sheets seen edge-on. A large gradation in cooling on a scale of parsecs is evidenced by the sequence of the optical species in emission, with a corresponding increase in density generally evidenced by the continuum radio emission.

Straka, W. C.↗

A high resolution electro-optical displacement measurement system

An improved electrooptical system has been developed to sense wind tunnel model position. The original system using 25.6 mm, 1024-element linear photodiode arrays (PDAs) is being successfully used at a NASA wind tunnel but has a limited range. A new two-channel system using 61.44 mm, 4096-element PDAs has been developed to double the range of vertical and pitch measurement and increase the resolution by 60 percent. The PDAs are illuminated by expanding the beam of a single low power helium neon laser into a collimated sheet of light. An object placed in front of the two parallel PDAs produces a shadow on the array apertures which determines the object's position or size. The system has an overall precision of 12.7 microns and + or - 0.015 degrees in linear and angular measurements.

Schott, Timothy D.↗

Next Generation Astronomical X-ray Optics: High Angular Resolution, Light Weight, and Low Production Cost

X-ray astronomy depends on the availability of telescopes with high resolution and large photon collecting areas. Since x-ray observation can only be carried out above the atmosphere, these telescopes must be necessarily lightweight. Compounding the lightweight requirement is that an x-ray telescope consists of many nested concentric shells, which further require that x-ray mirrors must also be geometrically thin to achieve high packing efficiency. This double lightweight and geometrically thin requirement poses significant technical challenges in fabricating the mirrors and in integrating them into mirror assemblies. This paper reports on the approach, strategy and status of our x-ray optics development program whose objective is to meet these technical challenges at modest cost to enable future x-ray missions, including small Explorer missions in the near term, probe class missions in the medium term, and large flagship missions in the long term.

Zhang. W. W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. This paper describes a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton , and Suzaku . This program will address the three key issues in making an x-ray telescope: (I) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of mono crystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the lightweighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10- arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. In this talk I will describe a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton, and Suzaku. This program will address the three key issues in making an x-ray telescope: (1) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO-type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of monocrystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the light-weighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10-arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Electron-optic limitations on image resolution

Various approaches are considered to the solution of the electron-optical problem of designing an image tube configuration. Emphasis is placed on the method of computer design, and an illustration is given in which the technique is used in the design of an 80-mm image tube with a zoom capability of 3:1. The solutions are discussed to such problems as image distortion, magnification, and electron bundles striking the zoom electrode. Three types of an electron-optical configuration are examined for the electron-optic limitations to resolution: (1) the proximity image tube, (2) the magnetic-type image tube having uniform electric and magnetic fields, and (3) the electrostatic-type image tube such as the 80-mm zoom tube.

Engstrom, R. W.↗

Achieving Large-Scale, High-Resolution, Full Shell Replicated X-Ray Optics: Budgeting for Sources of Spatial Resolution Errors

Technology for a large-area, high-angular resolution mirror module for a future Great Observatory x-ray mission is progressing along different paths. To date, none of these are fully developed. Work at the Marshall Space Flight Center (MSFC) seeks to leverage the benefits of full shell optics while exploring the limits of using shell replication technology for optics production. Here, we provide an updated accounting of spatial-resolution-constraining error terms to give context to recent improvements in MSFC replicated optics, as well as guidance and justification for current and future directions of research. Content includes strawman error allocations for an optical system that is parametrically Lynx-like, where the replicated-optics technology stands relative to these allocations, and methodology for mapping development plans to efficiently identify the limiting factors and approaches to overcoming these.

error budget↗

High-resolution spectroscopy of the optical candidate for the X-ray transient X0331 + 53

High-resolution spectral observations of the optical candidate for the X-ray transient X0331 + 53 are presented. The data show broad hydrogen and helium emission and strong interstellar absorption corresponding to a visual extinction of about 7 mag. No photospheric absorption in the emission lines, and no radial-velocity variations greater than 0.5 km/s were found over a three-day period. It is concluded that the optical continuum does not arise at or near the primary star. As an example of the spectrographic data, a resolution profile of H-alpha emission in X0331 + 53 is provided.

Stocke, J.↗

High spectral resolution lidar to measure optical scattering properties of atmospheric aerosols. II - Calibration and data analysis

The high spectral resolution lidar (HSRL) measures optical properties of atmospheric aerosols by interferometically separating the elastic aerosol backscatter from the Doppler broadened molecular contribution. Calibration and data analysis procedures developed for the HSRL are described. Data obtained during flight evaluation testing of the HSRL system are presented with estimates of uncertainties due to instrument calibration. HSRL measurements of the aerosol scattering cross section are compared with in situ integrating nephelometer measurements.

Sroga, J. T.↗

Report of the Science Working Group: Science with a lunar optical interferometer

Resolution is the greatest constraint in observational astronomy. The Earth's atmosphere causes on optical image to blur to about 1 arcsec or greater. Interferometric techniques have been developed to overcome atmospheric limitations for both filled aperture conventional telescopes and for partially filled aperture telescopes, such as the Michelson or the radio interferometer. The Hubble Space Telescope (HST) represents the first step toward space based optical astronomy. The HST represents an immediate short term evolution of observational optical astronomy. A longer time scale of evolution is focused on and the benefits are considered to astronomy of placing an array of telescopes on the Moon at a time when a permanent base may exist there.

Source record↗