Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

In-Flight Flow Visualization Using Infrared Thermography

The feasibility of remote infrared thermography of aircraft surfaces during flight to visualize the extent of laminar flow on a target aircraft has been examined. In general, it was determined that such thermograms can be taken successfully using an existing airplane/thermography system (NASA Dryden's F-18 with infrared imaging pod) and that the transition pattern and, thus, the extent of laminar flow can be extracted from these thermograms. Depending on the in-flight distance between the F-18 and the target aircraft, the thermograms can have a spatial resolution of as little as 0.1 inches. The field of view provided by the present remote system is superior to that of prior stationary infrared thermography systems mounted in the fuselage or vertical tail of a subject aircraft. An additional advantage of the present experimental technique is that the target aircraft requires no or minimal modifications. An image processing procedure was developed which improves the signal-to-noise ratio of the thermograms. Problems encountered during the analog recording of the thermograms (banding of video images) made it impossible to evaluate the adequacy of the present imaging system and image processing procedure to detect transition on untreated metal surfaces. The high reflectance, high thermal difussivity, and low emittance of metal surfaces tend to degrade the images to an extent that it is very difficult to extract transition information from them. The application of a thin (0.005 inches) self-adhesive insulating film to the surface is shown to solve this problem satisfactorily. In addition to the problem of infrared based transition detection on untreated metal surfaces, future flight tests will also concentrate on the visualization of other flow phenomena such as flow separation and reattachment.

vanDam, C. P.↗

Visible-Near Infrared Imaging Spectrometer Data of Explosion Craters

In a continuing study to capture a realistic terrain applicable to studies of cratering processes and landing hazards on Mars, we have obtained new high resolution visible-near infrared images of several explosion craters at the Nevada Test Site. We used the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) to obtain images in 224 spectral bands from 0.4-2.5 microns [1]. The main craters that were imaged were Sedan, Scooter, Schooner, Buggy, and Danny Boy [2]. The 390 m diameter Sedan crater, located on Yucca Flat, is the largest and freshest explosion crater on Earth that was formed under conditions similar to hypervelocity impact cratering. As such, it is effectively pristine, having been formed in 1962 as a result of the detonation of a 104 kiloton thermonuclear device, buried at the appropriate equivalent depth of burst required to make a "simple" crater [2]. Sedan was formed in alluvium of mixed lithology [3] and subsequently studied using a variety of field-based methods. Nearby secondary craters were also formed at the time and were also imaged by AVIRIS. Adjacent to Sedan and also in alluvium is Scooter, about 90 m in diameter and formed by a high-explosive event. Schooner (240 m) and Danny Boy (80 m, Fig. 1) craters were also important targets for AVIRIS as they were excavated in hard welded tuff and basaltic andesite, respectively [3, 4]. This variation in targets will allow the study of ejecta patterns, compositional modifications due to the explosions, and the role of craters as subsurface probes.

Farr, T. G.↗

Effects of Convective Transport of Solute and Impurities on Defect-Causing Kinetics Instabilities

For in-situ studies of the formation and evolution of step patterns during the growth of protein crystals, we have designed and assembled an experimental setup based on Michelson interferometry with the surface of the growing protein crystal as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a developed solution flow of controlled direction and speed. The reference arm of the interferometer contains a liquid-crystal element that allows controlled shifts of the phase of the interferograms. We employ an image processing algorithm which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 6-8 frames per second. The device allows data collection data regarding growth over a relatively large area (approximately .3 sq. mm) in-situ and in real time during growth. The estimated dept resolution of the phase shifting interferometry is about 100 A. The lateral resolution, depending on the zoom ratio, varies between 0.3 and 0.6 micrometers. We have now collected quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, position on the facet, crystal size and temperature with the proteins ferritin, apoferritin and thaumatin. Comparisons with theory, especially with the AFM results on the molecular level processes, see below, allow tests of the rational for the effects of convective flows and, as a particular case, the lack thereof, on step bunching.

Vekilov, Peter G.↗

Semi-Supervised Eigenbasis Novelty Detection

Recent discoveries in high-time-resolution radio astronomy data have focused attention on a new class of events. Fast transients are rare pulses of radio frequency energy lasting from microseconds to seconds that might be produced by a variety of exotic astrophysical phenomena. For example, X-ray bursts, neutron stars, and active galactic nuclei are all possible sources of short-duration, transient radio signals. It is difficult to anticipate where such signals might appear, and they are most commonly discovered through analysis of high-time- resolution data that had been collected for other purposes. Transients are often faint and difficult to detect, so improved detection algorithms can directly benefit the science yield of all such commensal monitoring. A new detection algorithm learns a low-dimensional linear manifold for describing the normal data. High reconstruction error indicates a novel signal that does not match the patterns of normal data. One unsupervised portion of the manifold model adapts its representation in response to recent data. A second supervised portion of the model is made of a basis trained in advance using labeled examples of RFI; this prevents false positives due to these events. For a linear model, an orthonormalization operation is used to combine these bases prior to the anomaly detection decision. Another novel aspect of the approach lies in combining basis vectors learned in an unsupervised, online fashion from the data stream with supervised basis vectors learned in advance from known examples of false alarms. Adaptive, data-driven detection is achieved that is also informed by existing domain knowledge about signals that may be statistically anomalous, but are not interesting and should therefore be ignored. The method was evaluated using data from the Parkes Multibeam Survey. This data set was originally collected to search for pulsars, which are astronomical sources that emit radio pulses at regular periods. However, several non-pulsar anomalies have recently been discovered in this dataset, making it a compelling test case. By explicitly filtering known false alarm patterns, the approach yields significantly better performance than current transient detection methods.

Wagstaff, Kiri L.↗

The influence of the hydrologic cycle on the extent of sea ice with climatic implications

Multi-temporal satellite images, field observations, and field measurements were used to investigate the mechanisms by which sea ice melts offshore from the Mackenzie River delta. Advanced Very High Resolution Radiometer (AVHRR) satellite data recorded in 1986 were analyzed. The satellite data were geometrically corrected and radiometrically calibrated so that albedo and temperature values could be extracted. The investigation revealed that sea ice melted approximately 2 weeks earlier offshore from the Mackenzie River delta than along coasts where river discharge is minimal or non-existent. There is significant intra-delta variability in the timing and patterns of ice melt. An estimation of energy flux indicates that 30 percent more of the visible wavelength energy and 25 percent more of the near-infrared wavelength energy is absorbed by water offshore of the delta compared to coastal areas with minimal river discharge. The analysis also revealed that the removal of sea ice involves the following: over-ice-flooding along the coast offshore from river delta channels; under-ice flow of 'warm' river water; melting and calving of the fast ice; and, the formation of a bight in the pack ice edge. Two stages in the melting of sea ice were identified: (1) an early stage where heat is supplied to overflows largely by solar radiation, and (2) a later stage where heat is supplied by river discharge in addition to solar radiation. A simple thermodynamic model of the thaw process in the fast ice zone was developed and parameterized based on events recorded by the satellite images. The model treats river discharge as the source of sensible heat at the base of the ice cover. The results of a series of sensitivity tests to assess the influence of river discharge on the near shore ice are presented.

Dean, Kenneson G.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

Exploring the Limits of the Data-Model-Theory Synergy: “Hot” MW Transitions for Rovibrational IR Studies

In order to further improve the accuracy of rovibrational IR line lists generated from the “Best Theory +Reliable High-resolution Experiment” (BTRHE) strategy from 0.01-0.05 cm-1, or 300-1500 MHz, to ~10 MHz, we explore the current limits of the Data-Model-Theory synergy by examining the accuracy and consistency of existing data, then propose that “hot” bands in microwave (MW) spectra is the solution we need for future enhancements. The Ames SO2 J=0-20 rovibrational energy levels computed on the semi-empirically refined Ames-2 potential energy surface (PES) are fit to the Effective Hamiltonian (EH) model regularly used in the experimental infrared (IR) analysis for SO2 isotopologues. In the fitted EH(Ames) model, the rotational constants A/B/C and all 5 quartic centrifugal distortion constants display clear, systematic, and consistent patterns along the vibrational state energy or quanta. Such consistent patterns may facilitate the vibrational assignments for MW hot bands and extract more information from high temperature MW spectra. Some EH(Expt) analyses were carried out with the lowest order Coriolis Coupling term, C1. Their constants should not be directly compared with other EH(Expt) and EH(Ames) results. After excluding them, our  = EH(Ames)- EH(Expt) analyses for 5 isotopologues (626, 636, 646, 628 and 828) indicates some loss of accuracy and consistency starting from vibrational states as low as 22 or 1000 cm-1. Some EH parameters, e.g. K, may have relative deviations as large as 50-100% and totally lose any recognizable patterns. This simply means that current EH(Expt) models do not have the system-wide consistency we need to further refine the EH(Ames) and Ames rovibrational IR line lists. A large part of such defects are probably inherited from the limited precision of experimental line positions, i.e. 1E-3 ~ 1E-4 cm-1, or 3-30 MHz. This is confirmed in a series of truncation tests using the Ames data. Although the EH(Ames) consistency may help identify unreliable rovibrational EH(Expt) parameters, and make reliable predictions for minor isotopologues and unobserved vibrational bands, we believe only the highly accurate “hot” MW transitions can provide real enhancements for EH(Expt) accuracy and consistency. “Hot” MW spectra should play a more significant role in the future synergy of Data, Model, and Theory in the field of rovibrational IR studies.

Xinchuan Huang↗

AFM Studies of Lunar Soils and Application to the Mars 2001 Mission

The upcoming Mars 01 mission will carry an Atomic Force Microscope (AFM) as part of the Mars Environmental Compatibility Assessment (MECA) instrument. By operating in a tapping mode, the AFM is capable of sub-nanometer resolution in three dimensions and can distinguish between substances of different compositions by employing phase contrast imaging. To prepare for the Mars 01 mission, we are testing the AFM on a lunar soil to determine its ability to define particle shapes and sizes and grain-surface textures. The test materials are from the Apollo 17 soil 79221, which is a mixture of agglutinates, impact and volcanic beads, and mare and highland rock and mineral fragments. The majority of the lunar soil particles are less than 100 microns in size, comparable to the sizes estimated for martian dust. We have used the AFM to examine several different soil particles at various resolutions. The instrument has demonstrated the ability to identify parallel ridges characteristic of twinning on a 150 micron plagioclase feldspar particle. Extremely small (10-100 nanometer) adhering particles are visible on the surface of the feldspar grain, and they appear elongate with smooth surfaces. Phase contrast imaging of the nanometer particles shows several compositions to be present. When the AFM was applied to a 100 micron glass spherule, it was possible to define an extremely smooth surface; this is in clear contrast to results from a basalt fragment which exhibited a rough surface texture. Also visible on the surface of the glass spherule were chains of 100 nanometer and smaller impact melt droplets. For the '01 Mars mission, the AFM is intended to define the size and shape distributions of soil particles, in combination with the NMCA optical microscope system and images from the Robot Arm Camera (RAC). These three data sets will provide a means of assessing potentially hazardous soil and dust properties. The study that we have conducted on the lunar soils now suggests that the NMCA experiment will be able to define grain transport and weathering processes. For example, it should be possible to determine if Martian grains have been subjected to aeolian or water transport, volcanic activity, impact melting processes, in-situ weathering, and a host of other processes. Additionally, textural maturity could be assessed (via freshness and form of fracture patterns and grain shapes). Thus, the AFM has the potential to shed new light on Martian surface processes by adding the submicroscopic dimension to planetary investigations.

Weitz, C. M.↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

A petabyte size electronic library using the N-Gram memory engine

A model library containing petabytes of data is proposed by Triada, Ltd., Ann Arbor, Michigan. The library uses the newly patented N-Gram Memory Engine (Neurex), for storage, compression, and retrieval. Neurex splits data into two parts: a hierarchical network of associative memories that store 'information' from data and a permutation operator that preserves sequence. Neurex is expected to offer four advantages in mass storage systems. Neurex representations are dense, fully reversible, hence less expensive to store. Neurex becomes exponentially more stable with increasing data flow; thus its contents and the inverting algorithm may be mass produced for low cost distribution. Only a small permutation operator would be recalled from the library to recover data. Neurex may be enhanced to recall patterns using a partial pattern. Neurex nodes are measures of their pattern. Researchers might use nodes in statistical models to avoid costly sorting and counting procedures. Neurex subsumes a theory of learning and memory that the author believes extends information theory. Its first axiom is a symmetry principle: learning creates memory and memory evidences learning. The theory treats an information store that evolves from a null state to stationarity. A Neurex extracts information data without a priori knowledge; i.e., unlike neural networks, neither feedback nor training is required. The model consists of an energetically conservative field of uniformly distributed events with variable spatial and temporal scale, and an observer walking randomly through this field. A bank of band limited transducers (an 'eye'), each transducer in a bank being tuned to a sub-band, outputs signals upon registering events. Output signals are 'observed' by another transducer bank (a mid-brain), except the band limit of the second bank is narrower than the band limit of the first bank. The banks are arrayed as n 'levels' or 'time domains, td.' The banks are the hierarchical network (a cortex) and transducers are (associative) memories. A model Neurex was built and studied. Data were 50 MB to 10 GB samples of text, data base, and images: black/white, grey scale, and high resolution in several spectral bands. Memories at td, S(m(sub td)), were plotted against outputs of memories at td-1. S(m(sub td)) was Boltzman distributed, and memory frequencies exhibited self-organized criticality (SOC); i.e., 'l/f(sup beta)' after long exposures to data. Whereas output signals from level n may be encoded with B(sub output) = O(-log(2)f(sup beta)) bits, and input data encoded with B(sub input) = O((S(td)/S(td-1))(sup n)), B(sup output)/B(sub input) is much less than 1 always, the Neurex determines a canonical code for data and it is a lossless data compressor. Further tests are underway to confirm these results with more data types and larger samples.

Bugajski, Joseph M.↗

Bioinspired Engineering of Exploration Systems (BEES) - its Impact on Future Missions

This paper describes an overview of our "Bioinspired Engineering of Exploration Systems for Mars" ( "BEES for Mars") project. The BEES approach distills selected biologically inspired strategies utilizing motion cues/optic flow, bioinspired pattern recognition, biological visual and neural control systems, bioinspired sensing and communication techniques, and birds of prey inspired search and track algorithmic systems. Unique capabilities so enabled, provide potential solutions to future autonomous robotic space and planetary mission applications. With the first series of tests performed in September 2003, August 2004 and September 2004, we have demonstrated the BEES technologies at the El Mirage Dry Lakebed site in the Mojave Desert using Delta Wing experimental prototypes. We call these test flyers the "BEES flyer", since we are developing them as dedicated test platform for the newly developed bioinspired sensors, processors and algorithmic strategies. The Delta Wing offers a robust airframe that can sustain high G launches and offers ease of compact stowability and packaging along with scaling to small size and low ReynOld's number performance for a potential Mars deployment. Our approach to developing light weight, low power autonomous flight systems using concepts distilled from biology promises to enable new applications, of dual use to NASA and DoD needs. Small in size (0.5 -5 Kg) BEES Flyers are demonstrating capabilities for autonomous flight and sensor operability in Mars analog conditions. The BEES project team spans JPL, NASA Ames, Australian National University (ANU), Brigham Young University(BYU), DC Berkeiey, Analogic Computers Inc. and other institutions. The highlights from our recent flight demonstrations exhibiting new Mission enabling capabilities are described. Further, this paper describes two classes of potential new missions for Mars exploration: (1) the long range exploration missions, and (2) observation missions, for real time imaging of critical ephemeral phenomena, that can be enabled by use of BEES flyers. For example, such flyers can serve as a powerful black-box for critical descent and landing data and enablers for improved science missions complementing and supplementing the existing assets like landers and rovers by providing valuable exploration and quick extended low-altitude aerial coverage of the sites of interest by imaging them and distributing instruments to them. Imaging done by orbiters allows broad surface coverage at limited spatial resolution. Low altitude air-borne exploration of Mars offers a means for imaging large areas, perhaps up to several hundred kilometers, quickly and efficiently, providing a close-up birds-eye view of the planetary terrain and close-up approach to constrained difficult areas like canyons and craters. A novel approach to low-mass yet highly capable flyers is enabled by small aircraft equipped using sensors and processors and algorithms developed using BEES technology. This project is focused towards showing the direct impact of blending the best of artificial intelligence attributes and bioinspiration to create a leap beyond existing capability for our future Missions.

navigation↗

Geoscience Laser Altimeter System (GLAS) for the ICESat Mission

The Geoscience Laser Altimeter System (GLAS) is a new generation lidar and is the primary science payload for NASA's ICESat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical distribution of clouds and aerosols on a global scale. GLAS will be integrated onto a small spacecraft built by Ball Aerospace, and will be launched into a polar orbit with a 590-630 km altitude at an inclination of 94 degrees. ICESat is is currently planned to launch in winter 2002/03 and GLAS is designed to operate continuously in space for a minimum of 3 years. GLAS will measure the vertical distance from orbit to the Earth's surface with pulses from a ND:YAG laser at a 40 Hz rate. Each 6 nsec wide 1064 nm laser pulse is used to produce a single range measurement. On the surface, the laser footprints have 66 m diameter and approx. 170 m center-center spacings. The GLAS receiver uses a I m diameter telescope to detect laser backscatter and a Si APD to detect the 1064 nm signals. The detector's output is sampled by a digital ranging receiver, which records each transmitted pulse and surface echo waveform with 1 nsec (15 cm) resolution. Each echo pulse is digitized and is reported to ground with a record length of from 200 to 544 samples, depending on the spacecraft's location . The GLAS location and epoch times are measured by a precision GPS receiver carried on the ICESat spacecraft. Initial processing of the echo waveforms within GLAS permits discrimination between cloud and surface echoes for selecting appropriate waveform samples. This selection is guided by an on-board DEM which is used to set the boundaries for the echo pulse search algorithm. Subsequent ground-based echo pulse analysis, along with GPS-based clock frequency estimates, permit final determination of the range to the surface, degree of pulse spreading, and vertical distribution of any vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when measuring over tilted surfaces, such as near the boundaries of ice sheets. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid angle to better than 10 urad is needed. GLAS uses a stellar reference system (SRS) to measure the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). GLAS will also measure the vertical distributions of clouds and aerosols by recording the vertical profiles of laser pulse backscatter at both 1064 and 532 nm. The 1064 rim measurements use the Si APD detector and will be used to measure the height and echo pulse shape from thicker clouds. The lidar receiver at 532 nm uses a narrow bandwidth etalon filter and highly sensitive photon counting detectors. The 532 nm backscatter profiles will be used to measure the vertical extent of thinner clouds and the atmospheric boundary layer. The GLAS instrument component development is complete and the instrument is undergoing final testing and qualification at NASA-Goddard. The GLAS "as-built" characteristics and its expected measurement performance will be discussed.

Abshire, James B.↗

Differences in Pre and Post Vascular Patterning of Retinas from ISS Crew Members and HDT Subjects by VESGEN Analysis

Accelerated research by NASA [1] has investigated the significant risks for visual and ocular impairments Spaceflight Associated Neuro-Ocular Syndrome /Visual Impairment/Intracranial Pressure (SANS/VIIP) incurred by microgravity spaceflight, especially long-duration missions. Our study investigates the role of blood vessels in the incidence and etiology of SANS/VIIP within the retinas of Astronaut crewmembers pre-and post-flight to the International Space Station (ISS) by NASA's VESsel GENeration Analysis (VESGEN). The response of retinal vessels in crewmembers to microgravity was compared to that of retinal vessels to Head-Down Tilt (HDT) in subjects undergoing 70-Day Bed Rest. The study tests the proposed hypothesis that cephalad fluid shifts missions, resulting in ocular and visual impairments, are necessarily mediated in part by retinal blood vessels, and are therefore accompanied by significant remodeling of retinal vasculature.Vascular patterns in the retinas of crew members and HDTBR subjects extracted from 30° infrared (IR) Heidelberg Spectralis® images collected pre/postflight and pre/post HDTBR, respectively, were analyzed by VESGEN (patent pending). a mature, automated software developed as a research discovery tool for progressive vascular diseases in the retina and other tissues [2]. The weighted, multi-parametric VESGEN analysis generates maps of branching arterial and venous trees and quantification by parameters such as the fractal dimension (Df, a modern measure of vascular space-filling capacity), vessel diameters, and densities of vessel length and number classified into specific branching generations by vascular physiological branching rules [2,3]. The retrospective study approved by NASA’s Institutional Review Board included six HDT subjects (NASA Flight Analogs Research Unit [FARU] Campaign 11; for example, [4]) and eight ISS crewmembers monitored by routine occupational surveillance who provided their study consents to NASA’s Lifetime Surveillance of Astronaut Health (LSAH). For the initial blinded VESGEN phase, ophthalmic retinal images were masked as to subject identity and pre- and post-status. In the second unblinded phase, VESGEN results were analyzed according to the pre- and post-status of left and right retinas matched to each subject. To complete our study, vascular results will be subjected to NASA biostatistical analysis and correlated with other ophthalmic and medical findings. Preliminary results for changes in the pre- to post-status of vascular patterning in the retinas of crewmembers and HDT subjects are strikingly opposite. By Df and other vascular branching measures, the space-filling capacity of arterial and venous trees decreased in a substantial subset of crewmembers (11/16 retinas). In contrast, vascular densities increased in a substantial subset of HDT subjects by the same parameters (6/10 retinas, currently excluding one anomalous subject). To conclude the study, biostatistical and medical analyses will be of critical importance for investigating the validity of these vascular findings. Vascular densities appeared to decrease in the retinas of crewmembers following ISS Missions, and increase in subjects after HDT. The vascular increases and decreases most likely derive primarily from limits of resolution to the ophthalmic imaging that does not capture the smallest vessels, rather than from vessel growth or atrophy. Differences in arterial and venous response to cephalad fluid shifts induced by ISS and HDT may have resulted from a long-duration conditioning phenomenon (for example, 6-month ISS missions compared to 70-day HDT), or the presence of gravity in HDT compared to microgravity onboard the ISS. To conclude our study, the biostatistical and medical analyses will be of critical importance for investigating the validity and significance of the VESGEN findings.

Murray, M. C.↗

Evaluation of the 7-km GEOS-5 Nature Run

This report documents an evaluation by the Global Modeling and Assimilation Office (GMAO) of a two-year 7-km-resolution non-hydrostatic global mesoscale simulation produced with the Goddard Earth Observing System (GEOS-5) atmospheric general circulation model. The simulation was produced as a Nature Run for conducting observing system simulation experiments (OSSEs). Generation of the GEOS-5 Nature Run (G5NR) was motivated in part by the desire of the OSSE community for an improved high-resolution sequel to an existing Nature Run produced by the European Centre for Medium-Range Weather Forecasts (ECMWF), which has served the community for several years. The intended use of the G5NR in this context is for generating simulated observations to test proposed observing system designs regarding new instruments and their deployments. Because NASA's interest in OSSEs extends beyond traditional weather forecasting applications, the G5NR includes, in addition to standard meteorological components, a suite of aerosol types and several trace gas concentrations, with emissions downscaled to 10 km using ancillary information such as power plant location, population density and night-light information. The evaluation exercise described here involved more than twenty-five GMAO scientists investigating various aspects of the G5NR performance, including time mean temperature and wind fields, energy spectra, precipitation and the hydrological cycle, the representation of waves, tropical cyclones and midlatitude storms, land and ocean surface characteristics, the representation and forcing effects of clouds and radiation, dynamics of the stratosphere and mesosphere, and the representation of aerosols and trace gases. Comparisons are made with observational data sets when possible, as well as with reanalyses and other long model simulations. The evaluation is broad in scope, as it is meant to assess the overall realism of basic aspects of the G5NR deemed relevant to the conduct of OSSEs. However, because of the relatively short record and other practical considerations, these comparisons cannot provide a definitive, statistically sound assessment of all model deficiencies, or guarantee the G5NR's suitability for all OSSE applications. Differences between the observed and simulated behavior also must be judged in the context of basic internal atmospheric variability which can introduce variations that are not necessarily controlled by the prescribed sea surface temperatures used in generating the G5NR. The results show that the G5NR performs well as measured by the majority of metrics applied in this evaluation. Particular benefits derived from the 7-km resolution of G5NR include realistic representations of extreme weather events in both the tropics and extratropics including tropical cyclones, Nor'easters and mesoscale convective complexes; improved representation of the diurnal cycle of precipitation over land; well-resolved surface-atmosphere interactions such as katabatic wind flows over Antarctica and Greenland; and resolution of orographically generated gravity waves that propagate into the upper atmosphere and influence the large scale circulation. Obvious deficiencies in the G5NR include a "splitting" of the inter-tropical convergence zone, which leads to a weaker-than-observed Hadley circulation and related deficiencies in the depiction of stationary wave patterns. Also, while the G5NR captures global cloud features and radiative effects well in general, close comparison with observations reveals higher-than-observed cloud brightness, likely due to an overabundance of cloud condensate; less distinct cloud minima in subtropical subsidence zones, consistent with a weak Hadley circualtion; and too few near-coastal marine stratocumulus clouds.

GEOS-5↗

The composite classification problem in optical information processing

Optical pattern recognition allows objects to be recognized from their images and permits their positional parameters to be estimated accurately in real time. The guiding principle behind optical pattern recognition is that a lens focusing a beam of coherent light modulated with an image produces the two-dimensinal Fourier transform of that image. When the resulting output is further transformed by the matched filter corresponding to the original image, one obtains the autocorrelation function of the original image, which has a peak at the origin. Such a device is called an optical correlator and may be used to recognize the locate the image for which it is designed. (From a practical perspective, an approximation to the matched filter must be used since the spatial light modulator (SLM) on which the filter is implemented usually does not allow one to independently control both the magnitude and phase of the filter.) Generally, one is not just concerned with recognizing a single image but is interested in recognizing a variety of rotated and scaled views of a particular image. In order to recognize these different views using an optical correlator, one may select a subset of these views (whose elements are called training images) and then use a composite filter that is designed to produce a correlation peak for each training image. Presumably, these peaks should be sharp and easily distinguishable from the surrounding correlation plane values. In this report we consider two areas of research regarding composite optical correlators. First, we consider the question of how best to choose the training images that are used to design the composite filter. With regard to quantity, the number of training images should be large enough to adequately represent all possible views of the targeted object yet small enough to ensure that the resolution of the filter is not exhausted. As for the images themselves, they should be distinct enough to avoid numerical difficulties yet similar enough to avoid gaps in which certain views of the target will be unrecognized. One method that we introduce to study this problem is called probing and involves the creation of the artificial imagery. The second problem we consider involves the clasification of the composite filter's correlation plane data. In particular, we would like to determine not only whether or not we are viewing a training image, but, in the former case, we would like to determine which training image is being viewed. This second problem is investigated using traditional M-ary hypothesis testing techniques.

Hall, Eric B.↗

Investigation of Magmatic Activities on Early Mars Using Igneous Mineral Chemistry in Gale Crater, Mars

One objective of rover missions is exploring the geological context of the surroundings. Over the years, igneous petrology and sedimentology have been disconnected, the first investigating magmatic processes and volcanic activities, and the second seeking environmental conditions in the past and assessing the habitability of the planet. Although different, one is related to the other: igneous rocks are altered and broken down, leading to the formation of sedimentary rocks, which can in turn be used to back out the nature of their magmatic source. The Curiosity rover that landed in the 3.7 Gyr old impact crater Gale is traveling through sedimentary rocks. About fifty float rocks have been observed, and several of them with ambiguous texture and composition have been classified as igneous or sedimentary depending on studies such as Jake_M. The composition of several unambiguous igneous rocks has been analyzed [4- 6] but their heterogeneity at a larger instrumental (measurement size < 2 cm) scale prevents the measurement of a bulk composition as performed on Earth. An original approach avoiding these two last issues is to consider igneous mineral chemistry analyzed within igneous and sedimentary rocks to assess magmatic processes that could have formed them. Most Curiosity data are used to explore ancient environmental conditions, and a significant number of compositional analyses are under-explored for constraining magmatic activities. We will present how we can make use of sedimentary data for investigating igneous processes in the vicinity of Gale crater. Geological Context: We focus on the first 750 martian days, corresponding to measurements in a coherent lacustrine sedimentary unit called Bradbury, because all sedimentary rocks were sourced from the same watershed and appear to have a consistent source with minimal alteration [2-3]. Igneous detrital minerals including feldspar and pyroxene, are observed in sedimentary rocks. Monte Carlo models showed that minimal cation loss is observed based on the composition of all Bradbury rocks, implying negligible weathering [3]. Although clay minerals are detected in few rocks [7], chemical compositions of rocks can be explained by a mixture of primary igneous minerals [3]. Variation of composition within Bradbury rocks can be explained by mineral sorting and one distinct source component. While a common magmatic source is suggested, Bradbury sediments likely come from several volcanic eruptions from a single magmatic chamber [9- 10]. The occurrence of alkali minerals like sanidine and K-rich rocks throughout Bradbury supports the presence of a potassic component, likely trachytic, while plagioclase and a mafic composition suggest a basaltic component [8-9]. Instruments: Mineral chemistry can be estimated by three instruments onboard Curiosity. The CheMin instrument enables detection of mineral assemblages using X-ray diffraction (XRD). Using Rietveld refinement, each mineral is identified according to their 1D XRD pattern [11]. Note that distinction between pyroxene minerals is challenging with the CheMin instrument due to overlapping peaks on XRD patterns and low angular resolution of the instrument [12]. Then, using least square regression and optimization algorithms based on unit-cell parameters, mineral chemistry has been estimated by [11]. Plagioclase composition has been estimated using the NaAlSi3O8- CaAl2Si2O8 system and alkali feldspar is based on the NaAlSi3O8-KAlSi3O8 system (stars in Fig.1). Two mudstone samples (John Klein and Cumberland) and one sandstone sample (Windjana) were analyzed by CheMin at Yellowknife Bay and Kimberley, respectively. Figure 1. Ternary diagrams of feldspars (top) and pyroxene (bottom) quadrilateral. Stars correspond to CheMin composition and the gray patches to ChemCam composition. The colored dots are the composition of feldspar and pyroxene that crystallized during fractional crystallization at FMQ+1 of a melt extracted at distinct melting degree during the adiabatic ascent of a primitive mantle composition, without any water (left panels) and with 0.5 wt.% of water (right panels) at distinct pressure. The ChemCam instrument enables the analysis of the chemical compositions of rocks at hundreds of micrometer scale (350-550 μm) using laser induced breakdown spectroscopy (LIBS), which may provide the composition of minerals when they are larger than the beam spot (>550 μm) [13]. Within >5000 LIBS points, we performed a typical stoichiometric filtering allowing us to distinguish 56 feldspar and 10 pyroxene mineral compositions (grey patches in Fig. 1). Finally, the Alpha Particle X-ray Spectrometer (APXS) analyzes the composition of rocks with a 1.6 cm diameter spot size. Monte Carlo mass balance modeling allowed [3] to decipher a feldspar range varying between An30 and An40 (Fig. 1). Discussion: Although there could be a more complex history and other ways to form the whole compositional range of igneous minerals analyzed within the Bradbury formation, we are presenting here simple magmatic pathways commonly occurring on Earth using the thermodynamical softwares pMELTS and rhyoliteMELTS [14]. The objective is to find reasonable igneous processes that produce minerals that parallel the compositions of feldspar and pyroxene analyzed by the Curiosity rover. As commonly observed for mid-ocean ridge basalts, the adiabatic ascent of a primitive mantle composition [15] partially melting at 2 GPa has been modeled, followed by the extraction of a liquid at distinct degrees of partial melting, which undergoes fractional crystallization at an oxygen fugacity +1 log unit above the fayalite-magnetite-quartz (FMQ) buffer within the crust (0.02-0.4 GPa) with H2O = 0- 0.5 wt. %. These latter conditions correspond to those recorded within igneous clasts from the Noachian martian breccia NWA 7034 and paired and within Gale igneous rocks (colored dots in Fig. 1) [16-17]. To check the reliability of these 2-step models, we also tested fractional crystallization at similar conditions (FMQ+1; P=0.02-0.4 GPa; H2O = 0-0.5 wt. %) of starting compositions corresponding to that of magmas with distinct melting degrees obtained from isobaric experiments at 2 GPa [18]. Mineral compositions obtained from both models are similar. As shown on Fig. 1, the whole range of observed feldspar compositions cannot be reproduced by fractionation of one magma only. Indeed, while alkali feldspar and Na-plagioclase likely crystallized from fractional crystallization of a low-degree melt (here <15%), plagioclase and pyroxene can only be formed by fractional crystallization of a higher degree melt (here >19%). The corresponding liquid descent lines are broadly in agreement with compositions estimated by ChemCam corresponding to float igneous rocks (Fig. 2) [4-6]. Figure 2. Silica versus alkali content. Lines show the liquid lines of descent from magmas with distinct degrees of melting. Gray patches represents the composition of Gale igneous rocks [4-6]. Trachytic to rhyolitic magmas crystallize alkali feldspar, and andesite to dacite magmas likely form plagioclase. Therefore, at least two starting magmas at distinct melting degrees, which could easily come from a single mantle source, are necessary to explain the whole compositional range of feldspar and pyroxene analyzed within Bradbury rocks. Conclusion: Because rocks from the Bradbury formation are likely originating from the same magmatic source with minimal weathering as supported by several studies using different approaches, igneous mineral chemistry analyzed by CheMin and ChemCam allows us to back out reasonable magmatic pathways that could have crystallized them. Fractional crystallization of at least two starting magmas originating from distinct melting degrees of a single mantle source can explain the whole range of feldspar and pyroxene composition. Both alkaline and sub-alkaline liquids can be produced, with compositions corresponding to those of the igneous rocks analyzed by ChemCam within the Bradbury formation, highlighting the complexity of Mars magmatism.

Payre, V.↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗