Search NASA⌕ Search

SEARCH · Search NASA

Results for “retina”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Polarization Perception Device

A polarization perception device comprises a base and a polarizing filter having opposite broad sides and a centerline perpendicular thereto. The filter is mounted on the base for relative rotation and with a major portion of the area of the filter substantially unobstructed on either side. A motor on the base automatically moves the filter angularly about its centerline at a speed slow enough to permit changes in light transmission by virtue of such movement to be perceived as light-dark pulses by a human observer, but fast enough so that the light phase of each such pulse occurs prior to fading of the light phase image of the preceding pulse from the observer's retina. In addition to an observer viewing a scene in real time through the filter while it is so angularly moved, or instead of such observation, the scene can be photographed, filmed or taped by a camera whose lens is positioned behind the filter.

Whitehead, Victor S.↗

Development of the Circadian Timing System in Rat Pups Exposed to Microgravity during Gestation

Ten pregnant Sprague Dawley rat dams were exposed to spaceflight aboard the Space Shuttle (STS-70) for gestational days 11-20 (G 11-20; FILT group). Control dams were maintained in either a flight-like (FIDS group) or vivarium cage environment (VIV group) on earth. All dams had ad lib access to food and water and were exposed to a light-dark cycle consisting of 12 hours of light (- 30 lux) followed by 12 hours of darkness. The dams were closely monitored from G 22 until parturition. All pups were cross-fostered at birth; each foster dam had a litter of 10 pups. Pups remained with their foster dam until post-natal day 21 (PN 21). Pup body mass was measured twice weekly. At PN14 FILT pups had a smaller body mass than did the VIV pups (p < 0.01). Circadian rhythms of body temperature and activity of pups from two FILT dams (n = 8), two FIDS dams (n = 9) and two VIV dams (n = 7) were studied starting from age PN 21. All pups had circadian rhythms of temperature and activity at this age. There were no significant differences in rhythms between groups that could be attributed to microgravity exposure. We also examined the development of neural structures involved in circadian rhythmicity: the retina, the intergeniculate leaflet (IGL) and the circadian pacemaker, the suprachiasmatic nucleus (SCN). There were small differences between the flight and control groups at very early stages of development (G 20 and PN3) which indicated that the development of both the SCN and the IGL. These results indicate that exposure to the microgravity environment of spaceflight during this embryonic development period does not affect the development of the circadian rhythms of body temperature and activity, but may affect the early development of the neural structures involved in circadian timing.

Fuller, Charles A.↗

Context-Specific Adaptation of Gravity-Dependent Vestibular Reflex Responses

Stabilization of the eyes and head during body movements is important for maintaining balance and keeping the images of objects stationary on our retinas. Impairment of this ability can lead to disorientation and reduced performance in sensorimotor tasks such as piloting of spacecraft. In the absence of a normal earth gravity field, the dynamics of head stabilization, and the interpretation of vestibular signals that sense gravity and linear acceleration, are subject to change. Transitions between different gravitoinertial force environments - as during different phases of space flight - provide an extreme test of the adaptive mechanisms that maintain these reflexive abilities. It is vitally important to determine human adaptive capabilities in such a circumstance, so that we can know to what extent the sensorimotor skills acquired in one gravity environment will transfer to others. Our work lays the foundation for understanding these capabilities, and for determining how we can aid the processes of adaptation and readaptation. An integrated set of experiments addresses this issue. We use the general approach of adapting some type of reflexive eye movement (saccades, the angular vestibulo-ocular reflex (AVOR), the linear vestibulo-ocular reflex (LVOR)), or the vestibulo-collic reflex (VCR), to a particular change in gain or phase in one condition of gravitoiner-tial force, and adapting to a different gain or phase (or asking for no change) in a second gravitoinertial force condition, and then seeing if the gravitoinertial force itself - the context cue - can recall the previously learned adapted responses. The majority of the experiments in the laboratory use the direction of vertical gaze or the direction of gravity (head tilt) as the context cue. This allows us to study context-specificity in a ground-based setting. One set of experiments, to be performed in parabolic flight, specifically uses the magnitude of gravitoinertial force as a context cue. This is a much better analog of the situation encountered in space flight. Various experiments investigate the behavioral properties, neurophysiological basis, and anatomical substrate of context-specific learning mechanisms. We use otolith (gravity) signals as the contextual cue for switching between adapted states of the saccadic system, the angular and linear vestibulo-ocular reflexes, and the VCR. (By LVOR we mean the oculomotor response - horizontal, vertical, and torsional - to linear translation of the head and body.) We are studying the effect of context on adaptation of saccade gain, phase and gain of the AVOR and LVOR, on ocular counterrolling (OCR) in response to static head tilt, and on head/neck reflexes (VCR) in response to rotation in different orientations. Such research is particularly germane to potential problems of postural and oculomotor control upon exposure to different gravitational environments.

Shelhamer, Mark J.↗

[Research Award providing funds for a tracking video camera]

The award provided funds for a tracking video camera. The camera has been installed and the system calibrated. It has enabled us to follow in real time the tracks of individual wood ants (Formica rufa) within a 3m square arena as they navigate singly in-doors guided by visual cues. To date we have been using the system on two projects. The first is an analysis of the navigational strategies that ants use when guided by an extended landmark (a low wall) to a feeding site. After a brief training period, ants are able to keep a defined distance and angle from the wall, using their memory of the wall's height on the retina as a controlling parameter. By training with walls of one height and length and testing with walls of different heights and lengths, we can show that ants adjust their distance from the wall so as to keep the wall at the height that they learned during training. Thus, their distance from the base of a tall wall is further than it is from the training wall, and the distance is shorter when the wall is low. The stopping point of the trajectory is defined precisely by the angle that the far end of the wall makes with the trajectory. Thus, ants walk further if the wall is extended in length and not so far if the wall is shortened. These experiments represent the first case in which the controlling parameters of an extended trajectory can be defined with some certainty. It raises many questions for future research that we are now pursuing.

Collett, Thomas↗

Dynamic Light Scattering of Diabetic Vitreopathy

Diabetes induces pathology throughout the body via nonenzymatic glycation of proteins. Vitreous, which is replete with type 11 collagen, undergoes significant changes in diabetes. The resultant diabetic vitreopathy plays an important role in diabetic retinopathy. Detecting these molecular changes could provide insight into diabetic eye disease as well as molecular effects elsewhere in the body. Human eyes were obtained at autopsy and studied in the fresh, unfixed state. Sclera, choroid, and retina were dissected off the vitreous for dark-field slit microscopy and dynamic light scattering (DLS). For the former, the entire vitreous was exposed. For the latter, only a window at the equator was dissected in some specimens, and the anterior segment was removed leaving the posterior lens capsule intact in others. DLS was performed to determine particle sizes at multiple sites 0.5 mm apart, spanning the globe at the equator (window dissections) and along the antero-posterior axis. Dark-field slit microscopy in diabetic subjects detected findings typical of age-related vitreous degeneration, but at much younger ages than nondiabetic controls. Noninvasive DLS measurements found a greater heterogeneity and larger particle sizes in vitreous of subjects with diabetes as compared to age-matched controls. DLS can detect and quantify the early molecular effects that cause vitreous collagen fibrils to cross-link and aggregate. This could provide valuable insight into ocular and systemic effects of hyperglycemia, because the molecular changes in diabetic vitreopathy could serve as an index of such effects throughout the body. In addition to the diagnostic implications, this methodology could provide a rapid, reproducible way to monitor the response to therapy with novel agents intended to prevent the complications of diabetes on a molecular level.

Sebag, J.↗

STS-53 Launch and Landing

Footage of various stages of the STS-53 Discovery launch is shown, including shots of the crew at breakfast, getting suited up, and departing to board the Orbiter. The launch is seen from many vantage points, as is the landing. On-orbit activities show the crew performing several medical experiments, such as taking a picture of the retina and measuring the pressure on the eyeball. One crewmember demonstrates how to use the rowing machine in an antigravity environment.

Source record↗

Effects of Body Orientation and Retinal Image Pitch on the Perception of Gravity-Referenced Eye Level (GREL)

It has been asserted that the pitch orientation of a visual array and of an observer's body jointly determine the perception of GREL. The current study formally tests this assertion over an extended range with multiple combinations of visual and body pitch orientations. Ten subjects were individually secured in a Circolectric bed surrounded by a room (pitchroom) with walls that could be pitched at various angles with respect to gravity. The bed and the walls of the room were independently adjusted to each of five positions relative to gravitational vertical: -15, -7.5, 0, +7.5, and +15 degrees, yielding 25 combinations of body x room pitch angles, and retinal image pitch (RIP) conditions ranging from -30 to +30 degrees. Each subject set a target to apparent GREL while viewing it against a background of two electroluminescent strips on the outer edges of the far wall of the room. As determined by ANOVA, the orientation of the room, and its interaction with that of the observer, significantly altered GREL (p less than 0.01). Regression analysis showed that GREL was best described as a linear summation of the weighted independent contributions from a body-referenced mechanism (B) and a visual mechanism given by the orientation of the background array on the retina (RIP). The equation for this relationship is: GREL = .74 (B) +.64 (RIP) - 1.42; r-squared = .994.

Cohen, Malcolm M.↗

Effects of Orientation on Recognition of Facial Affect

The ability to discriminate facial features is often degraded when the orientation of the face and/or the observer is altered. Previous studies have shown that gross distortions of facial features can go unrecognized when the image of the face is inverted, as exemplified by the 'Margaret Thatcher' effect. This study examines how quickly erect and supine observers can distinguish between smiling and frowning faces that are presented at various orientations. The effects of orientation are of particular interest in space, where astronauts frequently view one another in orientations other than the upright. Sixteen observers viewed individual facial images of six people on a computer screen; on a given trial, the image was either smiling or frowning. Each image was viewed when it was erect and when it was rotated (rolled) by 45 degrees, 90 degrees, 135 degrees, 180 degrees, 225 degrees and 270 degrees about the line of sight. The observers were required to respond as rapidly and accurately as possible to identify if the face presented was smiling or frowning. Measures of reaction time were obtained when the observers were both upright and supine. Analyses of variance revealed that mean reaction time, which increased with stimulus rotation (F=18.54, df 7/15, p (is less than) 0.001), was 22% longer when the faces were inverted than when they were erect, but that the orientation of the observer had no significant effect on reaction time (F=1.07, df 1/15, p (is greater than) .30). These data strongly suggest that the orientation of the image of a face on the observer's retina, but not its orientation with respect to gravity, is important in identifying the expression on the face.

Cohen, M. M.↗

Pursuit Eye Movements

When viewing objects, primates use a combination of saccadic and pursuit eye movements to stabilize the retinal image of the object of regard within the high-acuity region near the fovea. Although these movements involve widespread regions of the nervous system, they mix seamlessly in normal behavior. Saccades are discrete movements that quickly direct the eyes toward a visual target, thereby translating the image of the target from an eccentric retinal location to the fovea. In contrast, pursuit is a continuous movement that slowly rotates the eyes to compensate for the motion of the visual target, minimizing the blur that can compromise visual acuity. While other mammalian species can generate smooth optokinetic eye movements - which track the motion of the entire visual surround - only primates can smoothly pursue a single small element within a complex visual scene, regardless of the motion elsewhere on the retina. This ability likely reflects the greater ability of primates to segment the visual scene, to identify individual visual objects, and to select a target of interest.

Krauzlis, Rich↗

Image Processor

Texas Instruments Programmable Remapper is a research tool used to determine how to best utilize the part of a patient's visual field still usable by mapping onto his field of vision with manipulated imagery. It is an offshoot of a NASA program for speeding up, improving the accuracy of pattern recognition in video imagery. The Remapper enables an image to be "pushed around" so more of it falls into the functional portions in the retina of a low vision person. It works at video rates, and researchers hope to significantly reduce its size and cost, creating a wearable prosthesis for visually impaired people.

Source record↗

Eyeglass Filters

Biomedical Optical Company of America's suntiger lenses eliminate more than 99% of harmful light wavelengths. NASA derived lenses make scenes more vivid in color and also increase the wearer's visual acuity. Distant objects, even on hazy days, appear crisp and clear; mountains seem closer, glare is greatly reduced, clouds stand out. Daytime use protects the retina from bleaching in bright light, thus improving night vision. Filtering helps prevent a variety of eye disorders, in particular cataracts and age related macular degeneration.

Source record↗

Ocular Screening System

Used to detect eye problems in children through analysis of retinal reflexes, the system incorporates image processing techniques. VISISCREEN's photorefractor is basically a 35 millimeter camera with a telephoto lens and an electronic flash. By making a color photograph, the system can test the human eye for refractive error and obstruction in the cornea or lens. Ocular alignment problems are detected by imaging both eyes simultaneously. Electronic flash sends light into the eyes and the light is reflected from the retina back to the camera lens. Photorefractor analyzes the retinal reflexes generated by the subject's response to the flash and produces an image of the subject's eyes in which the pupils are variously colored. The nature of a defect, where such exists, is identifiable by atrained observer's visual examination.

Source record↗

Arteriosclerosis Detection

The Veterans Administration Hospital used computer image-processing techniques to detect arteriosclerosis. Originally developed by Goddard Space Flight Center engineers to enhance spacecraft pictures, this device replaced the previous testing for this disease which was extremely painful and time consuming. With this instrument, computer detected edges are shown along with an estimate of location of pre-arteriosclerosis vessel wall. The difference between the two represents the relative amount of disease in the blood vessel. Instrumentation will be expanded again in 1976 to analyze the coronary arteries and the blood vessels of the retina.

Source record↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Retinal ganglion cell projections to the hamster suprachiasmatic nucleus, intergeniculate leaflet, and visual midbrain: bifurcation and melanopsin immunoreactivity

The circadian clock in the suprachiasmatic nucleus (SCN) receives direct retinal input via the retinohypothalamic tract (RHT), and the retinal ganglion cells contributing to this projection may be specialized with respect to direct regulation of the circadian clock. However, some ganglion cells forming the RHT bifurcate, sending axon collaterals to the intergeniculate leaflet (IGL) through which light has secondary access to the circadian clock. The present studies provide a more extensive examination of ganglion cell bifurcation and evaluate whether ganglion cells projecting to several subcortical visual nuclei contain melanopsin, a putative ganglion cell photopigment. The results showed that retinal ganglion cells projecting to the SCN send collaterals to the IGL, olivary pretectal nucleus, and superior colliculus, among other places. Melanopsin-immunoreactive (IR) ganglion cells are present in the hamster retina, and some of these cells project to the SCN, IGL, olivary pretectal nucleus, or superior colliculus. Triple-label analysis showed that melanopsin-IR cells bifurcate and project bilaterally to each SCN, but not to the other visual nuclei evaluated. The melanopsin-IR cells have photoreceptive characteristics optimal for circadian rhythm regulation. However, the presence of moderately widespread bifurcation among ganglion cells projecting to the SCN, and projection by melanopsin-IR cells to locations distinct from the SCN and without known rhythm function, suggest that this ganglion cell type is generalized, rather than specialized, with respect to the conveyance of photic information to the brain. Copyright 2003 Wiley-Liss, Inc.

NASA Discipline Neuroscience↗

Three-dimensional ocular kinematics during eccentric rotations: evidence for functional rather than mechanical constraints

Previous studies have reported that the translational vestibuloocular reflex (TVOR) follows a three-dimensional (3D) kinematic behavior that is more similar to visually guided eye movements, like pursuit, rather than the rotational VOR (RVOR). Accordingly, TVOR rotation axes tilted with eye position toward an eye-fixed reference frame rather than staying relatively fixed in the head like in the RVOR. This difference arises because, contrary to the RVOR where peripheral image stability is functionally important, the TVOR like pursuit and saccades cares to stabilize images on the fovea. During most natural head and body movements, both VORs are simultaneously activated. In the present study, we have investigated in rhesus monkeys the 3D kinematics of the combined VOR during yaw rotation about eccentric axes. The experiments were motivated by and quantitatively compared with the predictions of two distinct hypotheses. According to the first (fixed-rule) hypothesis, an eye-position-dependent torsion is computed downstream of a site for RVOR/TVOR convergence, and the combined VOR axis would tilt through an angle that is proportional to gaze angle and independent of the relative RVOR/TVOR contributions to the total eye movement. This hypothesis would be consistent with the recently postulated mechanical constraints imposed by extraocular muscle pulleys. According to the second (image-stabilization) hypothesis, an eye-position-dependent torsion is computed separately for the RVOR and the TVOR components, implying a processing that takes place upstream of a site for RVOR/TVOR convergence. The latter hypothesis is based on the functional requirement that the 3D kinematics of the combined VOR should be governed by the need to keep images stable on the fovea with slip on the peripheral retina being dependent on the different functional goals of the two VORs. In contrast to the fixed-rule hypothesis, the data demonstrated a variable eye-position-dependent torsion for the combined VOR that was different for synergistic versus antagonistic RVOR/TVOR interactions. Furthermore, not only were the eye-velocity tilt slopes of the combined VOR as much as 10 times larger than what would be expected based on extraocular muscle pulley location, but also eye velocity during antagonistic RVOR/TVOR combinations often tilted opposite to gaze. These results are qualitatively and quantitatively consistent with the image-stabilization hypothesis, suggesting that the eye-position-dependent torsion is computed separately for the RVOR and the TVOR and that the 3D kinematics of the combined VOR are dependent on functional rather than mechanical constraints.

Non-NASA Center↗

Motor scaling by viewing distance of early visual motion signals during smooth pursuit

The geometry of gaze stabilization during head translation requires eye movements to scale proportionally to the inverse of target distance. Such a scaling has indeed been demonstrated to exist for the translational vestibuloocular reflex (TVOR), as well as optic flow-selective translational visuomotor reflexes (e.g., ocular following, OFR). The similarities in this scaling by a neural estimate of target distance for both the TVOR and the OFR have been interpreted to suggest that the two reflexes share common premotor processing. Because the neural substrates of OFR are partly shared by those for the generation of pursuit eye movements, we wanted to know if the site of gain modulation for TVOR and OFR is also part of a major pathway for pursuit. Thus, in the present studies, we investigated in rhesus monkeys whether initial eye velocity and acceleration during the open-loop portion of step ramp pursuit scales with target distance. Specifically, with visual motion identical on the retina during tracking at different distances (12, 24, and 60 cm), we compared the first 80 ms of horizontal pursuit. We report that initial eye velocity and acceleration exhibits either no or a very small dependence on vergence angle that is at least an order of magnitude less than the corresponding dependence of the TVOR and OFR. The results suggest that the neural substrates for motor scaling by target distance remain largely distinct from the main pathway for pursuit.

Non-NASA Center↗

Unilateral optic nerve transection alters light response of suprachiasmatic nucleus and intergeniculate leaflet

The suprachiasmatic nucleus (SCN), the circadian pacemaker, receives photic input directly from the retina to synchronize the pacemaker to the environment. Additionally, the intergeniculate leaflet (IGL), which innervates the SCN, is known to modulate the retinal photic input to the SCN. To further understand the role of the IGL in mediating the photic input to the SCN, this study examined the effects of unilateral optic nerve transection (UONx) on the photic response of the SCN and IGL in adult and neonatal hamsters. UONx led to an overall reduction in light-induced c-Fos expression in the SCN and IGL. The c-Fos expression was greater in the SCN ipsilateral to the remaining eye, despite a symmetrically bilateral retinohypothalamic tract projection as revealed by intraocular injection of horseradish peroxidase. In contrast, UONx led to a greater c-Fos expression in the contralateral IGL. The contralateral IGL of UONx animals also revealed more neuropeptide Y-immunoreactive neurons, while the ipsilateral SCN of these animals exhibited a denser neuropeptide Y terminal field. The neonates with UONx showed a similar pattern with a slight compensation of the photic-induced c-Fos in the SCN. This study suggests that the IGL may have an ipsilateral inhibitory effect in mediating retinal photic input to the SCN.

Non-NASA Center↗