Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample analyses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Dark Energy Survey 5-yr photometrically classified type Ia supernovae without host-galaxy redshifts

ABSTRACT Current and future Type Ia Supernova (SN Ia) surveys will need to adopt new approaches to classifying SNe and obtaining their redshifts without spectra if they wish to reach their full potential. We present here a novel approach that uses only photometry to identify SNe Ia in the 5-yr Dark Energy Survey (DES) data set using the SuperNNova classifier. Our approach, which does not rely on any information from the SN host-galaxy, recovers SNe Ia that might otherwise be lost due to a lack of an identifiable host. We select $2{,}298$ high-quality SNe Ia from the DES 5-yr data set an almost complete sample of detected SNe Ia. More than 700 of these have no spectroscopic host redshift and are potentially new SNIa compared to the DES-SN5YR cosmology analysis. To analyse these SNe Ia, we derive their redshifts and properties using only their light curves with a modified version of the SALT2 light-curve fitter. Compared to other DES SN Ia samples with spectroscopic redshifts, our new sample has in average higher redshift, bluer and broader light curves, and fainter host-galaxies. Future surveys such as LSST will also face an additional challenge, the scarcity of spectroscopic resources for follow-up. When applying our novel method to DES data, we reduce the need for follow-up by a factor of four and three for host-galaxy and live SN, respectively, compared to earlier approaches. Our novel method thus leads to better optimization of spectroscopic resources for follow-up.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning in the Context of Laser-Induced Breakdown Spectroscopy

The integration of machine learning (ML) with Laser-Induced Breakdown Spectroscopy (LIBS) has revolutionized the analytical capabilities of LIBS. The combi-nation of both methods enables more accurate and efficient data analysis. While LIBS itself is a powerful technique for elemental analysis, the vast amount of spectral data it generates can be hard to interpret. Machine learning addresses these challenges by leveraging algorithms that can learn from data, identify patterns, and make predictions without explicit programming for the interpretation of each specific task. In LIBS application, ML techniques are used to enhance various analytical processes. For example, ML algorithms can classify materials based on their spectral fingerprints, predict the concentration of elements in a sample, and identify underlying patterns within complex datasets. Here, this application improves the precision of LIBS analyses while significantly reducing the time required for data processing and interpretation. In this chapter, the fundamental concepts of ML will be discussed first. Following this, the process of data splitting and the importance of feature selection will be examined. Several machine learning methods will then be closely examined, exploring how each can benefit LIBS analysis and highlighting their respective advantages and shortcomings. This structured approach will provide a comprehensive understanding of the integration of ML in the context of LIBS analysis.

47 OTHER INSTRUMENTATION↗

Contributions of major tau kinase activation and phospho-tau accumulation to cortical and hippocampal tangle formation and cognition in older adults

Aberrant activation of tau kinases (tauK) has been proposed as a major step in tau hyperphosphorylation and misfolding, and subsequent formation of neurofibrillary tangles (NFT) in Alzheimer's disease (AD). However, evidence of tauK hyperactivation in actual AD brains is scarce and inconsistent, and their role in age-related cognitive decline remains undocumented. We evaluated activated/inhibited species of CDK5/p35/p25, GSK3a/ß, and ERK1/2 as well as ten tau/phospho-tau (ptau) peptides (mapping Ser 202 , Thr 217 , Ser 262 , Ser 305 , and Ser 404 phospho-residues) by Western blot or selected reaction monitoring proteomics, respectively, in postmortem dorsolateral prefrontal cortex (DLPFC) and hippocampal samples of 150 participants from the Rush Memory and Aging Project (MAP). Regression models and mediation analyses assessed the contributions of these variables to tau phosphorylation, NFT deposition and antemortem cognitive status of MAP participants. Surprisingly, greater p25 and p35 (indices for CDK5 activation) and lower pSer 21/9 -GSK3a/ß (inhibited species) immunodensities were associated with lower ptau peptide amounts. Individuals with higher p25 cortical densities displayed better cognitive outcomes, particularly working memory. Statistical mediation analyses indicated that the beneficial effect of CDK5/p25 on cognition was mediated by lower densities of phospho-Thr 217 -tau and NFT deposition in DLPFC, and also identified Thr 217 and Ser 262 as the ptau sites with greatest influence in both NFT accumulation and cognitive impairment. The present data suggest that tau hyperphosphorylation, tangle deposition, and the subsequent cognitive impairment do not rely on aberrant activation of major tauKs. Additionally, novel evidence was provided for the beneficial contribution of cortical CDK5/p25 to the maintenance of working memory.

60 APPLIED LIFE SCIENCES↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

Deep Learning Reconstruction of Daily Soil CO 2 Efflux Reveals Biogeochemical Insights and Reduces Annual Estimate Uncertainty Despite Limited Daily Predictability

Soil CO 2 efflux is commonly measured monthly or seasonally, leaving daily dynamics poorly resolved and contributing to global estimation uncertainty. We trained a single Long Short-Term Memory (LSTM) model to predict daily soil CO 2 efflux across 82 globally distributed sites in COSORE, with 0.2%–46.9% daily data coverage from 2003 to 2020. Despite using far fewer sites than are typically used to train a single deep learning model, with observations biased toward temperate mesic sites, the LSTM model performed well at approximately one-third of sites, reconstructed nearly 2 decades of daily efflux, and outperformed commonly used approaches for estimating daily efflux when applied to the same data set. Performance was weakest at pronounced peaks and troughs and at non-temperate sites with <1.5 years of observations and irregular data patterns. Nevertheless, annual efflux from reconstructed daily data had <40% error even at underperforming sites, substantially improving estimates derived from monthly and seasonal sampling (maximum errors of 95% and 136%, respectively). Temperature sensitivity (Q 10 ) estimated from reconstructed daily predictions closely matched estimates from daily observations, whereas Q 10 values derived from monthly or seasonal observations deviated substantially, suggesting that coarse temporal sampling may contribute to uncertainty in reported Q 10 values. Consistent daily reconstructions further enabled trend analyses for well-performing, predominantly temperate sites and showed increasing soil CO 2 efflux at most sites from 2003 to 2020, with more variable summer trends. Despite limitations, these results demonstrate the potential of LSTM models to reconstruct daily soil CO 2 efflux and reduce estimation uncertainties from sparse observations.

Smykalov, Valerie [Pennsylvania State University, ↗

Joint modelling of astrophysical systematics for cosmology with LSST cosmic shear

ABSTRACT We present a novel framework for jointly modelling the weak lensing source galaxy redshift distribution and the intrinsic alignment (IA) of galaxies through a shared luminosity function (LF). In the context of a Rubin Observatory’s Legacy Survey of Space and Time (LSST) Year 1 and Year 10 cosmic shear analysis, we show that our novel approach produces cosmological parameter constraints which are comparable to standard methods, while offering more physical insight into IA and selection effects. We clarify the relationship between individual parameters of a Schechter LF and the redshift distribution of a magnitude-limited sample, showing the consequences of marginalizing over these parameters when modelling IAs in standard cosmic shear analyses. We explore the impact of the shape of the LF on the cosmic shear data vector, and we outline the potential of this method to naturally model selection functions in redshift distribution estimation. Although this work focuses on LSST cosmic shear, the proposed joint modelling framework is broadly applicable to weak lensing surveys.

Šarčević, Nikolina (ORCID:0000000173016415)↗

National User Resource for Biological Accelerator Mass Spectrometry

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

Hot Hydrogen Exposure of U x Zr 1-x C y Nuclear Fuel: The Influence of Composition and Density

Refractory carbide nuclear fuel has been one of the most promising fuel candidates for space nuclear propulsion due to its high melting point, temperature stability, and compatibility in a hot hydrogen environment. In this study, U x Zr 1-x C y fuel was produced by means of a carbothermic reduction process in different UC compositions including 5,10, 20, and 30 at.% UC in the fuel compound. The powder feedstock was consolidated via direct current sintering with densities up to 97% of the theoretical density. The samples with different U x Zr 1-x C y compositions were exposed to hot hydrogen at 2600 K for a cumulative time of 300 min. The samples were characterized by SEM, XRD, density, and measured for mass losses. The high-density samples displayed improved performance in hot hydrogen by minimizing porous sites and reducing areas of direct contact with hydrogen gas, leading to reduced mass losses. Variations in sample density proved to induce large changes in mass loss rates, increasing them up to 90%. The compositions with higher UC content reported the largest mass losses in the study. The loss of uranium occurred primarily at the surfaces exposed to the hot hydrogen where changes in the lattice constant confirmed losses exceeding 50% of the initial UC content in higher compositions, specifically to U 0.3 Zr 0.7 C y . XRD analyses revealed the presence of UH 3 in U 0.3 Zr 0.7 C y suggesting that metallic uranium formed inside the sample as a product of carbon losses. High-density U x Zr x-1 C y fuel with UC concentrations at or below 20 at.% UC exhibited stability and negligible density changes in a high temperature hydrogen environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Improving NOvA&#x27;s Sterile Neutrino Search with the Booster Neutrino Beam

The NOvA experiment’s most recent search for eV-scale sterile neutrinos is systematically limited in the region of parameter space where $\Delta m^2_{41} \gtrsim 1~\mathrm{eV}^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies; improving sensitivity here is high-priority. When added directly into the fit, additional data samples which are subject to orthogonal systematic uncertainties act as in-situ constraints, breaking the degeneracy between systematic uncertainties and sterile-induced oscillations. The NOvA experiment consists of two functionally identical detectors, 14.6 mrad off-axis of the NuMI beam, with the Near Detector (Far Detector) 1 km (810 km) from the beam source. The Near Detector’s position on-site at Fermilab means that it is also able to observe neutrinos from a second neutrino beam, the BNB, 160 mrad off-axis. NOvA has been taking BNB data since 2015, but has not yet analysed these data. The BNB and NuMI are subject to different beam-related uncertainties, allowing us to leverage this sample as an in-situ constraint. This poster will present the current status, preliminary simulations, and potential additional uses of this unique experimental setup

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A joint analysis of 3D clustering and galaxy × CMB-lensing cross-correlations with DESI DR1 galaxies

The spectroscopic data from DESI Data Release 1 (DR1) galaxies enables the analysis of 3D clustering by fitting galaxy power spectra and reconstructed correlation functions in redshift space. Given low measurements of the amplitude of structure from cosmic shear at z ∼ 1, redshift space distortions (RSD) + Baryon Acoustic Oscillation (BAO) signals from DESI galaxies combined with weak lensing can break degeneracies and provide a tight alternative constraint on the z ∼ 1 amplitude of structure. In this paper we perform joint analyses that combine full-shape + post-reconstruction information from the DESI DR1 BGS and LRG samples along with angular cross-correlations with Planck PR4 and ACT DR6 CMB lensing maps. We show that adding galaxy-lensing cross-correlations tightens clustering amplitude constraints, improving σ 8 uncertainties by 30% over RSD+BAO alone. We also include angular galaxy-galaxy and galaxy-lensing spectra using photometric samples from the DESI Legacy Survey to further improve constraints. Our headline results are σ 8 = 0.803 ± 0.017, Ω m = 0.3037 ± 0.0069, and S 8 = 0.808 ± 0.017. Given DESI's preference for higher σ 8 compared to lower values from BOSS, we perform a catalog-level comparison of LRG samples from both surveys. We test sensitivity to dark energy assumptions by relaxing our ΛCDM prior and allowing for evolving dark energy via the w 0 - w a parameterization. We find our S 8 constraints to be relatively unchanged despite a 3.5σ tension with the cosmological constant model when combining with the Union3 supernova likelihood. Finally we test general relativity (GR) by allowing the gravitational slip parameter (γ) to vary, and find γ = 1.17 ± 0.11 in mild (∼ 1.5σ) tension with the GR value of 1.0.

cosmological parameters from LSS↗

Whole metagenome sequencing and 16S rRNA gene amplicon analyses reveal the complex microbiome responsible for the success of enhanced in-situ reductive dechlorination (ERD) of a tetrachloroethene-contaminated Superfund site

The North Railroad Avenue Plume (NRAP) Superfund site in New Mexico, USA exemplifies successful chlorinated solvent bioremediation. NRAP was the result of leakage from a dry-cleaning that operated for 37 years. The presence of tetrachloroethene biodegradation byproducts, organohalide respiring genera (OHRG), and reductive dehalogenase (rdh) genes detected in groundwater samples indicated that enhanced reductive dechlorination (ERD) was the remedy of choice. This was achieved through biostimulation by mixing emulsified vegetable oil into the contaminated aquifer. This report combines metagenomic techniques with site monitoring metadata to reveal new details of ERD. DNA extracts from groundwater samples collected prior to and at four, 23 and 39 months after remedy implementation were subjected to whole metagenome sequencing (WMS) and 16S rRNA gene amplicon (16S) analyses. The response of the indigenous NRAP microbiome to ERD protocols is consistent with results obtained from microcosms, dechlorinating consortia, and observations at other contaminated sites. WMS detects three times as many phyla and six times as many genera as 16S. Both techniques reveal abundance changes in Dehalococcoides and Dehalobacter that reflect organohalide form and availability. Methane was not detected before biostimulation but appeared afterwards, corresponding to an increase in methanogenic Archaea. Assembly of WMS reads produced scaffolds containing rdh genes from Dehalococcoides, Dehalobacter, Dehalogenimonas, Desulfocarbo, and Desulfobacula. Anaerobic and aerobic cometabolic organohalide degrading microbes that increase in abundance include methanogenic Archaea, methanotrophs, Dechloromonas, and Xanthobacter, some of which contain hydrolytic dehalogenase genes. Aerobic cometabolism may be supported by oxygen gradients existing in aquifer microenvironments or by microbes that produce O 2 via microbial dismutation. The NRAP model for successful ERD is consistent with the established pathway and identifies new taxa and processes that support this syntrophic process. This project explores the potential of metagenomic tools (MGT) as the next advancement in bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating cosmological biases using photometric redshifts for Type Ia Supernova cosmology with the Dark Energy Survey Supernova Program

Cosmological analyses with Type Ia Supernovae (SNe Ia) have traditionally been reliant on spectroscopy for both classifying the type of supernova and obtaining reliable redshifts to measure the distance–redshift relation. While obtaining a host-galaxy spectroscopic redshift for most SNe is feasible for small-area transient surveys, it will be too resource intensive for upcoming large-area surveys such as the Vera Rubin Observatory Legacy Survey of Space and Time, which will observe on the order of millions of SNe. Here, we use data from the Dark Energy Survey (DES) to address this problem with photometric redshifts (photo-z) inferred directly from the SN light curve in combination with Gaussian and full p(z) priors from host-galaxy photo-z estimates. Using the DES 5-yr photometrically classified SN sample, we consider several photo-z algorithms as host-galaxy photo-z priors, including the Self-Organizing Map redshifts (SOMPZ), Bayesian Photometric Redshifts (BPZ), and Directional-Neighbourhood Fitting (DNF) redshift estimates employed in the DES 3 × 2 point analyses. With detailed catalogue-level simulations of the DES 5-yr sample, we find that the simulated w can be recovered within ±0.02 when using SN+SOMPZ or DNF prior photo-z, smaller than the average statistical uncertainty for these samples of 0.03. With data, we obtain biases in w consistent with simulations within ~1σ for three of the five photo-z variants. We further evaluate how photo-z systematics interplay with photometric classification and find classification introduces a subdominant systematic component. This work lays the foundation for next-generation fully photometric SNe Ia cosmological analyses.

(cosmology:) dark energy↗

Visualizing the Internal Nanocrystallinity of Calcite Due to Nonclassical Crystallization by 3D Coherent X–Ray Diffraction Imaging

The internal crystallinity of calcite is investigated for samples synthesized using two approaches: precipitation from solution and the ammonium carbonate diffusion method. Scanning electron microscopy (SEM) analyses reveal that the calcite products precipitated using both approaches have a well–defined rhombohedron shape, consistent with the euhedral crystal habit of the mineral. The internal structure of these calcite crystals is characterized using Bragg coherent diffraction imaging (BCDI) to determine the 3D electron density and the atomic displacement field. BCDI reconstructions for crystals synthesized using the ammonium carbonate diffusion approach have the expected euhedral shape, with internal strain fields and few internal defects. In contrast, the crystals synthesized by precipitation from solution have very complex external shapes and defective internal structures, presenting null electron density regions and pronounced displacement field distributions. These heterogeneities are interpreted as multiple crystalline domains, created by a nonclassical crystallization mechanism, where smaller nanoparticles coalescence into the final euhedral particles. The combined use of SEM, X–ray diffraction (XRD), and BCDI allows for structurally differentiating calcite crystals grown with different approaches, opening new opportunities to understand how grain boundaries and internal defects alter calcite reactivity.

36 MATERIALS SCIENCE↗

Observation of D → a 0 ( 980 ) π in the decays D 0 → π + π − η and D + → π + π 0 η

We report the first amplitude analyses of the decays D 0 → π + π − η and D + → π + π 0 η using a data sample taken with the BESIII detector at the center-of-mass energy of 3773 MeV, corresponding to an integrated luminosity of 7.9 fb − 1 . The contribution from the process D 0 ( + ) → a 0 ( 980 ) + π − ( 0 ) is significantly larger than the D 0 ( + ) → a 0 ( 980 ) − ( 0 ) π + contribution. The ratios B ( D 0 → a 0 ( 980 ) + π − ) / B ( D 0 → a 0 ( 980 ) − π + ) and B ( D + → a 0 ( 980 ) + π 0 ) / B ( D + → a 0 ( 980 ) 0 π + ) are measured to be 7.5 − 0.8 stat + 2.5 ± 1.7 syst and 2.6 ± 0.6 stat ± 0.3 syst , respectively. The measured D 0 ratio disagrees with the theoretical predictions by orders of magnitudes, thus implying a substantial contribution from final-state interactions. Published by the American Physical Society 2024

Ablikim, M.↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗