Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Reversible oxygen intercalation in hexagonal Y 0.7 Tb 0.3 MnO 3+δ : toward oxygen production by temperature-swing absorption in air

The oxygen storage capacity, structure and thermodynamic stability were studied for hexagonal Y 0.7 Tb 0.3 MnO 3+δ in oxygen and air to assess its applicability for oxygen separation from air by a temperature-swing adsorption process. We show that large amounts of oxygen excess can be reversibly incorporated into and extracted from small particle-size samples of Y 0.7 Tb 0.3 MnO 3+δ prepared by sol–gel synthesis for fixed oxygen partial pressures. The hyperstoichiometric material, with δ ≥ 0.45 prepared in oxygen or high-pressure oxygen atmospheres, assumes a new hexagonal structure with interstitial oxygen defects near the nominally five coordinated Mn site as determined by neutron diffraction and supported by scanning and transmission electron microscopy. Thermogravimetric measurements demonstrate reversible intercalation of oxygen in a pure O 2 atmosphere at around 300 °C, but more importantly, also in air over a remarkably narrow temperature range of ~20 °C, albeit producing smaller oxygen amounts δ ≤ 0.25. Comparison of samples' properties obtained by the sol–gel and solid-state synthesis methods confirms enhanced oxygen storage capacity and oxygen exchange kinetics for the small particle-size samples which exhibit larger specific surface areas. Sequential temperature-swing absorption and long-term annealing experiments demonstrate the high practical potential of Y 0.7 Tb 0.3 MnO 3 compounds for the industrial production of oxygen enriched gases by utilization of waste heat at 250–350 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

Structure of amorphous GeSe{sub 9} by neutron diffraction and first-principles molecular dynamics: Impact of trajectory sampling and size effects

The structure of glassy GeSe{sub 9} was investigated by combining neutron diffraction with density-functional-theory-based first-principles molecular dynamics. In the simulations, three different models of N = 260 atoms were prepared by sampling three independent temporal trajectories, and the glass structures were found to be substantially different from those obtained for models in which smaller numbers of atoms or more rapid quench rates were employed. In particular, the overall network structure is based on Se{sub n} chains that are cross-linked by Ge(Se{sub 4}){sub 1/2} tetrahedra, where the latter are predominantly corner as opposed to edge sharing. The occurrence of a substantial proportion of Ge–Se–Se connections does not support a model in which the material is phase separated into Se-rich and GeSe{sub 2}-rich domains. The appearance of a first-sharp diffraction peak in the Bhatia-Thornton concentration-concentration partial structure factor does, however, indicate a non-uniform distribution of the Ge-centered structural motifs on an intermediate length scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methane Leaks from Natural Gas Systems Follow Extreme Distributions

Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4 ) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ~15,000 measurements from 18 prior studies, we show that all available natural gas leakage datasets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used lognormal model distributions, we show that lognormal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of datasets to increase sample size is not recommended due to apparent deviation between sampled populations. Finally, understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.

03 NATURAL GAS↗

Bayesian estimation of Karhunen–Loève expansions; A random subspace approach

One of the most widely-used statistical procedures for dimensionality reduction of high dimensional random fields is Principal Component Analysis (PCA), which is based on the Karhunen-Lo eve expansion (KLE) of a stochastic process with finite variance. The KLE is analogous to a Fourier series expansion for a random process, where the goal is to find an orthogonal transformation for the data such that the projection of the data onto this orthogonal subspace is optimal in the L 2 sense, i.e, which minimizes the mean square error. In practice, this orthogonal transformation is determined by performing an SVD (Singular Value Decomposition) on the sample covariance matrix or on the data matrix itself. Sampling error is typically ignored when quantifying the principal components, or, equivalently, basis functions of the KLE. Furthermore, it is exacerbated when the sample size is much smaller than the dimension of the random field. In this paper, we introduce a Bayesian KLE procedure, allowing one to obtain a probabilistic model on the principal components, which can account for inaccuracies due to limited sample size. The probabilistic model is built via Bayesian inference, from which the posterior becomes the matrix Bingham density over the space of orthonormal matrices. We use a modified Gibbs sampling procedure to sample on this space and then build a probabilistic Karhunen-Lo eve expansions over random subspaces to obtain a set of low-dimensional surrogates of the stochastic process. We illustrate this probabilistic procedure with a finite dimensional stochastic process inspired by Brownian motion.

97 MATHEMATICS AND COMPUTING↗

Salvaging Data Records with Missing Data: Data Imputation using the Multivariate t Distribution

When doing multivariate data analysis, one commonobstacle is the presence of incomplete observations, i.e., observationsfor which one or more key fields are blank. Missing datais often countered by deleting entire observations that containmissing data. The negative effects of deleting entire observationsare multiple: deleting observations reduces sample size andcan also result in biased inferences even if data is missing atrandom. In addition, knowledge contained within incompleteobservations is knowledge lost when they are deleted– and theeffort spent collecting that knowledge is effort wasted. Data imputationmethods, or methods of statistically “filling-in” missingdata, can help combat small sample sizes by using the existinginformation in partially complete observations with the end goalof producing less biased and higher confidence inferences. Whena sample from a multivariate normal population is only partiallycomplete, and the missing data meets appropriate assumptions(missing at random), robust data imputation of the missing datacan be implemented with monotone data augmentation (MDA)using the multivariate t distribution.Missing data imputation is applied to data from the NASA InstrumentCost Model (NICM) using the MDA algorithm underthe assumption of having a multivariate t distribution with fixeddegrees of freedom. A sensitivity analysis to the degrees offreedom parameter is presented to demonstrate robustness ofthe multivariate t distribution when dealing with small samplesas compared to the multivariate normal distribution.

DiNicola, Michael↗

Nested Neutron Microfocusing Optics on SNAP

The high source intensity of the Spallation Neutron Source (SNS), together with efficient detectors and large detector solid angles, now makes possible neutron experiments with much smaller sample volumes than previously were practical. Nested Kirkpatrick–Baez supermirror optics provide a promising and efficient way to further decrease the useable neutron sample size by focusing polychromatic neutrons into microbeams. Because the optics are nondispersive, they are ideal for spallation sources and for polychromatic and wide bandpass experiments on reactor sources. Theoretical calculations indicate that nested mirrors can preserve source brilliance at the sample for small beams and for modest divergences that are appropriate for diffraction experiments. Although the flux intercepted by a sample can be similar with standard beam-guided approaches, the signal-to-background is much improved with small beams on small samples. Here we describe the design, calibration and performance of a nested neutron mirror pair for the Spallation Neutrons At Pressure (SNAP) beamline at the SNS. High-pressure neutron diffraction is but one example of a large class of neutron experiments that will benefit from spatially-resolved microdiffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A GRAVITATIONAL REDSHIFT DETERMINATION OF THE MEAN MASS OF WHITE DWARFS: DBA AND DB STARS

We measure apparent velocities (v{sub app}) of absorption lines for 36 white dwarfs (WDs) with helium-dominated atmospheres-16 DBAs and 20 DBs-using optical spectra taken for the European Southern Observatory SN Ia progenitor survey. We find a difference of 6.9 {+-} 6.9 km s{sup -1} in the average apparent velocity of the H{alpha} lines versus that of the He I 5876 A lines for our DBAs. This is a measure of the blueshift of this He line due to pressure effects. By using this as a correction, we extend the gravitational redshift method employed by Falcon et al. to use the apparent velocity of the He I 5876 A line and conduct the first gravitational redshift investigation of a group of WDs without visible hydrogen lines. We use biweight estimators to find an average apparent velocity, (v{sub app}){sub BI}, (and hence average gravitational redshift, (v{sub g}){sub BI}) for our WDs; from that we derive an average mass, (M){sub BI}. For the DBAs, we find (v{sub app}){sub BI} = 40.8 {+-} 4.7 km s{sup -1} and derive (M){sub BI} = 0.71{sup +0.04}{sub -0.05} M{sub Sun }. Though different from (v{sub app}) of DAs (32.57 km s{sup -1}) at the 91% confidence level and suggestive of a larger DBA mean mass than that for normal DAs derived using the same method (0.647{sup +0.013}{sub -0.014} M{sub Sun }; Falcon et al.), we do not claim this as a stringent detection. Rather, we emphasize that the difference between (v{sub app}){sub BI} of the DBAs and (v{sub app}) of normal DAs is no larger than 9.2 km s{sup -1}, at the 95% confidence level; this corresponds to roughly 0.10 M{sub Sun }. For the DBs, we find (v {sup He}{sub app}){sub BI} = 42.9 {+-} 8.49 km s{sup -1} after applying the blueshift correction and determine (M){sub BI} = 0.74{sup +0.08}{sub -0.09} M{sub Sun }. The difference between (v{sup He}{sub app}){sub BI} of the DBs and (v{sub app}) of DAs is {<=}11.5 km s{sup -1} ({approx}0.12 M{sub Sun }), at the 95% confidence level. The gravitational redshift method indicates much larger mean masses than the spectroscopic determinations of the same sample by Voss et al. Given the small sample sizes, it is possible that systematic uncertainties are skewing our results due to the potential of kinematic substructures that may not average out. We estimate this to be unlikely, but a larger sample size is necessary to rule out these systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-AB-BRA-04: Quantitative Radiomics: Sensitivity of PET Textural Features to Image Acquisition and Reconstruction Parameters Implies the Need for Standards

Purpose: Despite increased use of heterogeneity metrics for PET imaging, standards for metrics such as textural features have yet to be developed. We evaluated the quantitative variability caused by image acquisition and reconstruction parameters on PET textural features. Methods: PET images of the NEMA IQ phantom were simulated with realistic image acquisition noise. 35 features based on intensity histograms (IH), co-occurrence matrices (COM), neighborhood-difference matrices (NDM), and zone-size matrices (ZSM) were evaluated within lesions (13, 17, 22, 28, 33 mm diameter). Variability in metrics across 50 independent images was evaluated as percent difference from mean for three phantom girths (850, 1030, 1200 mm) and two OSEM reconstructions (2 iterations, 28 subsets, 5 mm FWHM filtration vs 6 iterations, 28 subsets, 8.6 mm FWHM filtration). Also, patient sample size to detect a clinical effect of 30% with Bonferroni-corrected α=0.001 and 95% power was estimated. Results: As a class, NDM features demonstrated greatest sensitivity in means (5–50% difference for medium girth and reconstruction comparisons and 10–100% for large girth comparisons). Some IH features (standard deviation, energy, entropy) had variability below 10% for all sensitivity studies, while others (kurtosis, skewness) had variability above 30%. COM and ZSM features had complex sensitivities; correlation, energy, entropy (COM) and zone percentage, short-zone emphasis, zone-size non-uniformity (ZSM) had variability less than 5% while other metrics had differences up to 30%. Trends were similar for sample size estimation; for example, coarseness, contrast, and strength required 12, 38, and 52 patients to detect a 30% effect for the small girth case but 38, 88, and 128 patients in the large girth case. Conclusion: The sensitivity of PET textural features to image acquisition and reconstruction parameters is large and feature-dependent. Standards are needed to ensure that prospective trials which incorporate textural features are properly designed to detect clinical endpoints. Supported by NIH grants R01 CA169072, U01 CA148131, NCI Contract (SAIC-Frederick) 24XS036-004, and a research contract from GE Healthcare.

60 APPLIED LIFE SCIENCES↗

The Relationship Between Gelatin Sponge Preparation Methods and the Incidence of Intrauterine Synechia Following Uterine Artery Embolization for Postpartum Hemorrhage

Purpose: To evaluate the relationship between gelatin sponge preparation methods and the incidence of intrauterine synechia following uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: In a retrospective monocentric study, we used data from 20 consecutive UAE procedures (19 patients) for PPH, performed in 2007–2016, in which gelatin sponge had been used. The gelatin sponge was processed either into a slurry by pumping it back and forth about 10 times through two syringes connected to a three-way stopcock or into pledgets using a scalpel and small scissors to obtain pieces approximately 2 × 2 × 2 mm in size. Patient information was obtained from medical records, and the data were compared between patients treated with the slurry (n = 7) or pledgets (n = 13) forms. Due to the lack of follow-up data and hysterectomy after UAE, the sample size was 6 and 12 because 1 patient with 2 procedures was excluded. Results: The rate of intrauterine synechia was significantly higher in the slurry group (5/6, 83.3%) than that in the pledgets group (0/12, 0%; P < 0.001). In contrast, there were no significant differences in population characteristics, such as the incidence of placenta accreta, non-placental diseases, and severity of shock (DIC score, shock index, or blood loss) between the groups. Conclusions: Although non-randomization and small sample size were the two main limitations, our observations suggest that UAE using gelatin sponge slurry may be associated with a high incidence of intrauterine synechia compared to UAE using pledgets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies

Because natural gas emits less carbon than other fossil fuels, it holds promise as a green energy transition fuel. However, the overall carbon footprint of natural gas is significantly elevated by methane emissions that occur during its production and transmission (Cusworth et al. 2022). Methane “super-emitters,” while comprising only about 1% of sites, are responsible for the majority of oil- and gas-sourced methane emissions, making their detection and mitigation critical in reducing the climate impact of natural gas and in meeting national and global sustainability goals (Sherwin et al. 2024). Yet, despite advancements in detection, significant uncertainties remain regarding the size, frequency, and duration distributions of methane emissions (e.g., Frankenberg et al. 2016, Cusworth et al. 2022, Chen, Sherwin et al. 2022, Conrad et al. 2023, Johnson et al. 2023, Sherwin et al. 2024) underscoring the need for comprehensive emissions inventories segmented by basin across the US. Airborne surveys are well-suited for collecting data to build these comprehensive, basin-level inventories because they allow for extensive spatial coverage, and have the spatial resolution, and the sensitivity to pinpoint individual methane sources. As remote sensing technologies enable rapid basin-scale surveys, it is imperative to establish scientifically and statistically robust standards to generate reliable and actionable emissions inventories. Recent work has shown that differences in airborne sampling strategies, detection technologies, and analysis can lead to large differences between survey conclusions if not correctly accounted for (Chen et al. 2024). This elevates the importance of incorporating proper sampling and analysis techniques when designing a methane emissions monitoring campaign to produce accurate results and facilitate cross-study comparisons. In this paper, we describe a survey strategy designed using the latest conclusions from the literature to align results from different aerial surveys. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions. We present results from a Department of Energy-funded project that deployed this survey strategy in two understudied oil and gas- producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma.

03 NATURAL GAS↗

Type Ibn Supernovae Show Photometric Homogeneity and Spectral Diversity at Maximum Light

Type Ibn supernovae (SNe) are a small yet intriguing class of explosions whose spectra are characterized by low-velocity helium emission lines with little to no evidence for hydrogen. The prevailing theory has been that these are the core-collapse explosions of very massive stars embedded in helium-rich circumstellar material (CSM). We report optical observations of six new SNe Ibn: PTF11rfh, PTF12ldy, iPTF14aki, iPTF15ul, SN 2015G, and iPTF15akq. This brings the sample size of such objects in the literature to 22. We also report new data, including a near-infrared spectrum, on the Type Ibn SN 2015U. In order to characterize the class as a whole, we analyze the photometric and spectroscopic properties of the full Type Ibn sample. We find that, despite the expectation that CSM interaction would generate a heterogeneous set of light curves, as seen in SNe IIn, most Type Ibn light curves are quite similar in shape, declining at rates around 0.1 mag day{sup −1} during the first month after maximum light, with a few significant exceptions. Early spectra of SNe Ibn come in at least two varieties, one that shows narrow P Cygni lines and another dominated by broader emission lines, both around maximum light, which may be an indication of differences in the state of the progenitor system at the time of explosion. Alternatively, the spectral diversity could arise from viewing-angle effects or merely from a lack of early spectroscopic coverage. Together, the relative light curve homogeneity and narrow spectral features suggest that the CSM consists of a spatially confined shell of helium surrounded by a less dense extended wind.

79 ASTRONOMY AND ASTROPHYSICS↗

A Multi-Armed Bayesian Ordinal Outcome Utility-Based Sequential Trial with a Pairwise Null Clustering Prior

A multi-armed trial based on ordinal outcomes is proposed that leverages a flexible non-proportional odds cumulative logit model and numerical utility scores for each outcome to determine treatment optimality. This trial design uses a Bayesian clustering prior on the treatment effects that encourages the pairwise null hypothesis of no differences between treatments. A group sequential design is proposed to determine which treatments are clinically different with an adaptive decision boundary that becomes more aggressive as the sample size or clinical significance grows, or the number of active treatments decreases. A simulation study is conducted for 3 and 5 treatment arms, which shows that the design has superior operating characteristics (family wise error rate, generalized power, average sample size) compared to utility designs that do not allow clustering, a frequentist proportional odds model, or a permutation test based on empirical mean utilities.

97 MATHEMATICS AND COMPUTING↗

Robust Period Estimation Using Mutual Information for Multiband Light Curves in the Synoptic Survey Era

The Large Synoptic Survey Telescope (LSST) will produce an unprecedented amount of light curves using six optical bands. Robust and efficient methods that can aggregate data from multidimensional sparsely sampled time-series are needed. Here, we present a new method for light curve period estimation based on quadratic mutual information (QMI). The presented method does not assume a particular model for the light curve nor its underlying probability density and it is robust to non-Gaussian noise and outliers. By combining the QMI from several bands the true period can be estimated even when no single-band QMI yields the period. Period recovery performance as a function of average magnitude and sample size is measured using 30,000 synthetic multiband light curves of RR Lyrae and Cepheid variables generated by the LSST Operations and Catalog simulators. The results show that aggregating information from several bands is highly beneficial in LSST sparsely sampled time-series, obtaining an absolute increase in period recovery rate up to 50%. We also show that the QMI is more robust to noise and light curve length (sample size) than the multiband generalizations of the Lomb–Scargle and AoV periodograms, recovering the true period in 10%–30% more cases than its competitors. A python package with efficient Cython implementations of the QMI and other methods is provided.

79 ASTRONOMY AND ASTROPHYSICS↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

WHERE ARE THE LOW-MASS POPULATION III STARS?

We study the number and the distribution of low-mass Population III (Pop III) stars in the Milky Way. In our numerical model, hierarchical formation of dark matter minihalos and Milky-Way-sized halos are followed by a high-resolution cosmological simulation. We model the Pop III formation in H{sub 2} cooling minihalos without metal under UV radiation of the Lyman–Werner bands. Assuming a Kroupa initial mass function (IMF) from 0.15 to 1.0 M {sub ⊙} for low-mass Pop III stars, as a working hypothesis, we try to constrain the theoretical models in reverse by current and future observations. We find that the survivors tend to concentrate on the center of halo and subhalos. We also evaluate the observability of Pop III survivors in the Milky Way and dwarf galaxies, and constraints on the number of Pop III survivors per minihalo. The higher latitude fields require lower sample sizes because of the high number density of stars in the galactic disk, the required sample sizes are comparable in the high- and middle-latitude fields by photometrically selecting low-metallicity stars with optimized narrow-band filters, and the required number of dwarf galaxies to find one Pop III survivor is less than 10 at <100 kpc for the tip of red giant stars. Provided that available observations have not detected any survivors, the formation models of low-mass Pop III stars with more than 10 stars per minihalo are already excluded. Furthermore, we discuss the way to constrain the IMF of Pop III stars at a high mass range of ≳10 M {sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-212: Influence of the Modulation Index On Daily Quality Assurance in Rapid Arc Treatments

Purpose: At our Institute some measured parameters for daily quality assurance (DQA) of dynamic arc therapy plans showed an unexpected behavior, therefore an investigation of the influence of the magnitude of modulation was conducted. Methods: In our clinical practice all DQAs of dynamic arc therapy plans are measured and analyzed prior to treatments using commercial software. For this study these plans were additionally exported to our in-house software written in MATLAB.The developed software extracted the leaf position, gantry angle, cumulative meterset weight of each control point (CP) and the total number of Monitor Units (MU) of each arc. Based on this information we calculated the leaf travel distance, irradiated segment area, number of MUs and dose rate for each CP. These data allowed us to calculate the modulation indexes (MI) of the plans, applying five different definitions of MI. The results were then correlated to the results of our DQA measurements.To validate the software, additional plans of known MIs were created and analyzed. For confirmation, the calculated parameters were compared to the segmented treatment table (STT) coming from the treatment planning system. Results: All calculated CP-parameters matched the STT by 99% or better. For linac 1, the comparison of the MI evaluation and the DQA results showed a slight tendency: 91.3% failed DQA plans had a MI lower than the average value. For this definition we consider that the lower the MI the higher the modulation. The results of the linac 2 present no significant relevance due to the low sample sizes for each DQA software. Conclusion: Available data and given definitions of the modulation index do not bring conclusive results; one cannot find a clear and distinct correlation with the failure of the DQA. The ongoing analysis with an increased sample size might lead to another conclusion.

07 ISOTOPE AND RADIATION SOURCES↗

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Drug and Alcohol (D&A) Testing

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Alcohol and Drug Testing Ivan R. Thomas Idaho National Laboratory The random sampling with replacement of Human Reliability Program (HRP) participants for alcohol and drug testing can have the disadvantage that some participants are selected multiple times while others might not be chosen during an annual testing period. To alleviate this inefficiency, an “hourglass” sampling scheme has been developed at the Idaho National Laboratory for the random selection of HRP participants. With this scheme, all HRP participants are placed in a primary population at the beginning of the calendar year, and throughout the year, sequential random samples (generally of a fixed sample size) are drawn without replacement until the population is emptied. Thus, each participant is guaranteed to be tested at least once annually; but due to the random selection, the time of the initial test is unknown. After initial testing, the participants drawn from the primary population are transferred to a secondary population for potential retesting. Each time that the primary population is sampled, the secondary population is likewise sampled, but the sampling is with replacement. Thus, while the primary population decreases at a constant rate, the secondary population increases at the same rate through the accrual and retention of previously-tested participants, hence the hourglass concept. The replacement sampling of participants from the secondary population is through an increasing sample size (a fixed percentage of those currently in the population). Thus, once in the secondary population, each participant has a constant probability of being reselected, but the number of annual reselections is less than would be realized through traditional replacement sampling from a single population. Furthermore, the objective of maintaining suspense on the part of the HRP participant is retained, that is, all participants, whether or not initially picked from the primary population or reselected from the secondary population, always anticipate a future selection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗