Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Transverse photoresistivity from photothermal current deflection in metal films

Quantum geometry in centrosymmetric systems has motivated the search for photocurrent responses beyond second order. In particular, electric field-induced nonlinear responses may also enable intrinsic polarization-sensitive optical detectors. Despite numerous efforts, clear methods are still needed to remove experimental artifacts, separating intrinsic from extrinsic effects, and disentangling linear responses from their higher-order counterparts. Here, we provide a systematic study of fabrication and measurement techniques to remove external artifacts in photoelectronic responses. This reveals a previously hidden photothermoelectric response in the transverse photoresistivity of symmetric thin films of simple metals. We identify its origin in thermal gradients producing current deflection and determine the device design and measurement parameters to minimize extrinsic effects that arise in photoinduced electronic responses.

Bolometric effect↗

Investigating the ultraviolet photodissociation of bromocyclopropane with ultrafast electron diffraction

We have studied the photodissociation of gas-phase bromocyclopropane by 200 nm wavelength ultraviolet radiation using ultrafast electron diffraction. Bromocyclopropane is a prototypical molecule in the study of organobromides, a class of molecules that have a significant impact on atmospheric ozone depletion through their photochemistry. Here, previous studies have revealed two possible reaction pathways for the photodissociation of bromine from bromocyclopropane; either the C–Br bond dissociates, leaving behind a cyclopropyl ring, or there is a concerted opening of the cyclopropyl ring along with the C–Br bond dissociation. In this work, both our experimental and simulation results indicate that the majority of the UV-photoexcited BCP molecules (88% ± 11% in the experiment) follow the first reaction pathway, in which the cyclopropyl ring remains closed after homolytic C–Br bond cleavage. This direct bond dissociation occurs within the experimental time resolution of 270 fs. In order to differentiate between the possible reaction end-products, both of which have diffraction signals dominated by the bromine atom, a new analysis method has been employed, which is more sensitive to the structure of the end-products.

Atmospheric chemistry↗

An extensible perturbed parameter ensemble for the Community Atmosphere Model version 6

This paper documents the methodology and preliminary results from a perturbed parameter ensemble (PPE) technique, where multiple parameters are varied simultaneously and the parameter values are determined with Latin hypercube sampling. This is done with the Community Atmosphere Model version 6 (CAM6), the atmospheric component of the Community Earth System Model version 2 (CESM2). We apply the PPE method to CESM2–CAM6 to understand climate sensitivity to atmospheric physics parameters. The initial simulations vary 45 parameters in the microphysics, convection, turbulence and aerosol schemes with 263 ensemble members. These atmospheric parameters are typically the most uncertain in many climate models. Control simulations and targeted simulations to understand climate forcing due to aerosols and fast climate feedbacks are analyzed. The use of various emulators is explored in the multi-dimensional space mapping input parameters to output metrics. Parameter impacts on various model outputs, such as radiation, cloud and aerosol properties, are evaluated. Machine learning is also used to probe optimal parameter values against observations. Our findings show that PPE is a valuable tool for climate uncertainty analysis. Furthermore, by varying many parameters simultaneously, we find that many different combinations of parameter values can produce results consistent with observations, and thus careful analysis of tuning is important. The CESM2–CAM6 PPE is publicly available and extensible to other configurations to address questions of other model processes in the atmosphere and other model components (e.g., coupling to the land surface).

54 ENVIRONMENTAL SCIENCES↗

Dressed-State Hamiltonian Engineering in a Strongly Interacting Solid-State Spin Ensemble

In quantum science applications, ranging from many-body physics to quantum metrology, dipolar interactions in spin ensembles are often controlled via Floquet engineering. However, this technique typically reduces the interaction strength between spins and effectively weakens the coupling to a target sensing field, limiting the metrological sensitivity. In this Letter, we develop and demonstrate an alternative method that directly tunes the native dipolar interaction in an ensemble of nitrogen-vacancy (NV) centers in diamond, thereby overcoming these limitations inherent to Floquet engineering. Our approach utilizes dressed-state qubit encoding under a bias magnetic field applied perpendicular to the crystal lattice orientation. This method leads to a 3.2× enhancement of the dimensionless coherence parameter JT 2 compared to state-of-the-art Floquet engineering and a 2.6× (8.3 dB) enhanced sensitivity in ac magnetometry. Furthermore, our results provide a powerful Hamiltonian engineering tool for future studies with NV ensembles and other interacting higher-spin (S > $\frac{1}{2}$) systems.

Quantum control↗

Data-driven high-dimensional statistical inference with generative models

Crucial to many measurements at the LHC is the use of correlated multi-dimensional information to distinguish rare processes from large backgrounds, which is complicated by the poor modeling of many of the crucial backgrounds in Monte Carlo simulations. In this work, we introduce HI-SIGMA, a method to perform unbinned high-dimensional statistical inference with data-driven background distributions. In contradistinction to many applications of Simulation Based Inference in High Energy Physics, HI-SIGMA relies on generative ML models, rather than classifiers, to learn the signal and background distributions in the high-dimensional space. These ML models allow for interpretable inference while also incorporating model errors and other sources of systematic uncertainties. We showcase this methodology on a simplified version of a di-Higgs measurement in the bbγγ final state, where the di-photon resonance allows for background interpolation from sidebands into the signal region. We demonstrate that HI-SIGMA provides improved sensitivity as compared to standard classifier-based methods, and that systematic uncertainties can be straightforwardly incorporated by extending methods which have been used for histogram based analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Dynamic Boundary Microgrids Under Privatization Considerations

Microgrids have physical, electrical, and logical (data, network, and ownership) boundaries. To power unserved customer loads during an outage, microgrids can extend the traditional operational boundaries. This can become complex when considering microgrid-to-microgrid (M2M) interactions where sensitive information such as competitive microgrid operational data is not shared. This work proposes an optimization method coordinated between microgrid controllers and distribution management systems that limits data sharing. The method involves a competitive bidding strategy that maximizes unserved load coverage while minimizing resource utilization and sensitive operational data sharing among entities. The work is validated on a two-microgrid system with photovoltaic and energy storage systems and curves of load derived from real world residential buildings datasets. Results show that the proposed method, when applied for three distinct use cases of energy storage sufficiency to cover the predefined boundary and/or the expanded boundary, can successfully select and bid the available load coverage.

Starke, Michael [ORNL] (ORCID:0000000221211195)↗

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography↗

Revisiting a minimally destructive analytic approach for determining electrochemical kinetic parameters: Measuring aluminum corrosion across a wide pH range based on the Butler-Volmer equation

Here, this study revisits the three-point sampling of the simplified Butler-Volmer equation to address the limitations of strong potentiodynamic polarization, which can introduce irreversible damage and uncertainty in corrosion analysis. The method extracts electrochemical kinetic parameters while minimizing polarization effects, evaluates noise sensitivity relative to overpotential, and accounts for errors from signal noise, OCP drift, ohmic resistance, and mass-transfer constraints. Verified against the Tafel extrapolation method for aluminum corrosion across a wide pH range, this low-polarization approach enables accurate evaluations with specific error estimates, offering a robust alternative to linear polarization resistance methods that assume constant Tafel slopes.

36 MATERIALS SCIENCE↗

Where do the fish go in winter? A year of observing seasonal changes in Sequim Bay’s nearshore fish community

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments. eDNA offers a non-invasive, cost-effective, and scalable way to detect aquatic species. It is appealing in environments where traditional methods are limited by access or visibility, especially in complex or sensitive habitats such as tidal channels and other marine energy sites. Before eDNA can be fully relied upon, we must verify its accuracy against established methods, like underwater photography. In this study, we collected eDNA samples and concurrently deployed a 360-degree camera near the floating dock of PNNL-Sequim in the tidal channel of Sequim Bay once a month for twelve consecutive months. During deployments, the camera remained on the seafloor for several hours overlapping slack tide and captured time-lapse photographs at ten second intervals. Counts and identifications of fish species observed in the images were used to calculate monthly Shannon diversity and Pielou evenness indices. These values were compared across the months using a Kruskal-Wallis test paired with a Conover-Iman post-hoc test. Cliff’s Delta was also calculated to quantify the effect size of the monthly differences. No fish were observed from December through April, likely due to seasonal behavior changes within the local fish community. Fish returned to the shoreline in May, with the greatest diversity and evenness recorded in September. These findings reveal substantial seasonal variation in nearshore fish communities. Many monthly comparisons were found to contain statistically significant differences within the diversity and evenness, and even more were found to have large effect sizes, signifying large ecological changes throughout the seasons. The absence of fish observed during the winter months is a key outcome of this survey that will hopefully be reflected in the eDNA results still to come, which would help validate the eDNA approach.

59 BASIC BIOLOGICAL SCIENCES↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

A Sensitive Electrochemical Cholinesterase-Inhibiting Biosensor for Organophosphorus Pesticides Based on Ti 3 C 2 TX MXene Quantum Dots

Organophosphorus pesticides (OPs) pose significant environmental and health risks due to their widespread use and toxicity, primarily by inhibiting acetylcholinesterase. Traditional detection methods are often slow and costly, highlighting the urgent need for advanced, sensitive, and accessible technologies. This study developed a highly sensitive electrochemical cholinesterase-inhibiting biosensor for OP pesticides, utilizing Ti 3 C 2 T x MXene Quantum Dots (MQDs), which was synthesized via a hydrothermal method. The biosensor’s performance was characterized using electrochemical impedance spectroscopy, differential pulse voltammetry (DPV), and cyclic voltammetry. DPV proved to be the optimal technique, exhibiting an ultralow detection limit of 1 × 10 −17 M and a wide linear range (10 −14 –10 −8 M) for chlorpyrifos (a model OP) with an estimated inhibition constant of 62 nM. The biosensor demonstrated high selectivity for OPs (chlorpyrifos, acephate, glyphosate) over a non-target pyrethroid (permethrin), confirmed by distinct electrochemical signatures and compared to in vitro cholinergic activity assays in bean beetle homogenates. The enhanced performance is attributed to the high surface-to-volume ratio, quantum confinement effects, and superior conductivity of the MQDs, as well as the robust enzyme immobilization facilitated by glutaraldehyde cross-linking and a chitosan matrix. This work presents a promising platform for rapid, sensitive, and selective detection of OP pesticides, with potential applications in environmental monitoring and public health protection.

Chemistry↗

Benchmarking Concentration and Extraction Methods for Wastewater-Based Surveillance of Eight Human Respiratory Viruses: Implications for Rapid Application to Novel Pathogens

To provide early warning and support a rapid response to a novel virus through wastewater surveillance, it would be ideal to understand in advance which concentration and extraction methods are likely to be effective for dPCR-based methods, depending on virus characteristics. In this study, we spiked raw wastewater samples with eight human respiratory viruses and processed them with four methods that concentrate and/or extract nucleic acids from both liquid and solid fractions (Promega, Nanotrap, and InnovaPrep) or only the solid fraction of wastewater (Solids). Our findings provide encouraging evidence that all four methods combined with dPCR could detect an emerging virus in wastewater, although they differed in sensitivity. The pattern of recovery efficiency for adenoviruses, coronaviruses, and influenza A viruses was consistent across methods, with Promega producing higher median recovery efficiencies, while distinct patterns were observed for coxsackieviruses. We also normalized the concentration data with two endogenous fecal indicators, PMMoV and Carjivirus (formerly crAssphage). We found that normalization could reduce method-associated differences if the indicator exhibited a recovery pattern similar to that of the target virus. These findings can guide the selection of concentration and extraction methods for wastewater monitoring based on the properties of target viruses, thus enhancing pandemic preparedness.

Biological and medical sciences↗

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Weakly supervised anomaly detection for resonant new physics in the dijet final state using proton-proton collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

An anomaly detection search for narrow-width resonances beyond the Standard Model that decay into a pair of jets is presented. The search is based on 139 fb −1 of proton-proton collisions at $\sqrt{s}$ = 13 TeV recorded during 2015–2018 with the ATLAS detector at the Large Hadron Collider. The analysis is optimized without a particular signal model and aims to be sensitive to a broad range of new physics. It uses two different machine learning strategies to estimate the background in different signal regions. In each region, a weakly supervised classifier is trained to distinguish this background model from data. The analysis focuses on events with high transverse momentum jets reconstructed as large-radius jets. The mass and substructure of these jets are used as inputs to the classifiers. After a classifier-based selection, the distribution of the invariant mass of the two jets is used to search for potential local excesses. The model-independent results of both the anomaly detection methods show no signs of significant local excesses. In addition to model-independent results, a representative set of signal models is injected into the data, and the sensitivity of the methods to these scenarios is reported.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗

Non-nuclear Component Signatures for Warhead Dismantlement Confirmation

The verification of warhead dismantlement is expected to be an important component in future arms reduction treaties. Historic approaches developed with future arms control treaty verification in mind often involve intrusive measurements, process monitoring, and/or inspector presence to provide confidence that an authentic warhead has been dismantled. This work explores the possibility of reducing the negative impacts of these invasive approaches while also delivering a method that is more likely to provide non-sensitive data that can be shared with not only other nuclear weapons states but also non-nuclear weapons states partners. This work explores a novel approach for verifying dispositioned non-nuclear weapon components, providing confidence post-dismantlement that a treaty accountable item that was dismantled was in fact a treaty-relevant nuclear weapon system as declared. This method provides an alternative to intrusive inspection processes in nuclear weapons production environments, which would require significant changes to the host’s operational behaviors. It achieves this by identifying intrinsic neutron-induced signatures of non-nuclear components to determine their authenticity and estimate the duration they were exposed within a nuclear weapons system using technologies that are already in use for other national security applications. Intrinsic radiation effects studies are already a part of the stockpile aging and surveillance evaluations. However, none of these technologies and approaches have been previously considered for verification applications of non-nuclear component disposition. In this report, we introduce modeling studies that have been used to identify the most promising candidate parts and materials with signatures that are measurable and actionable. These models have been validated with laboratory measurements of signatures induced by the exposure of candidate materials to neutrons over a range of times. Predictive modeling then demonstrates the methodology for estimating exposure times and/or limits. Laboratory measurements of authentic non-nuclear parts from a dismantled warhead demonstrate the feasibility of employing these signature measurements. And finally, a concept of operations (CONOPS) for the potential use of this methodology is presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗