Multi purpose display panel

The multi purpose panel (MPP) project was undertaken to demonstrate the feasibility of producing a control signal which could be time shared among several subsystems and which would permit rapid and inexpensive modification of control panel functions. It is intended to bridge the gap between Multifunction Display Systems, which offer excellent display flexibility but present man-machine interface problems, and dedicated control panels, which offer no flexibility. A control panel was developed with programmable displays located near enough to control and display components to provide an acceptable man-machine interface.

Source record↗

Teleoperated position control of a PUMA robot

A laboratory distributed computer control teleoperator system is developed to support NASA's future space telerobotic operation. This teleoperator system uses a universal force-reflecting hand controller in the local iste as the operator's input device. In the remote site, a PUMA controller recieves the Cartesian position commands and implements PID control laws to position the PUMA robot. The local site uses two microprocessors while the remote site uses three. The processors communicate with each other through shared memory. The PUMA robot controller was interfaced through custom made electronics to bypass VAL. The development status of this teleoperator system is reported. The execution time of each processor is analyzed, and the overall system throughput rate is reported. Methods to improve the efficiency and performance are discussed.

Austin, Edmund↗

Goldstone high power radiation control

The airspace near Goldstone is shared by many users in carrying out their respective missions. Coordination of Goldstone high power transmitter radiation activity with mutual airspace users near Goldstone is an effective method to prevent aircraft from being exposed to radiation levels greater than 10 mW/sq cm, to allow Goldstone to transmit high power levels for planetary radar experiments and to provide the necessary information to both civil and military aircraft users to enable them to perform their necessary activities.

Gaudian, B. A.↗

Control of Rate-Bounded Hybrid Systems with Liveness Specifications

In the present paper we examine the control problem for a class of composite hybrid machines (CHMs) that consist of concurrent operation (employing synchronous composition) of elementary hybrid machines (EHMs), that allows both signal sharing and event synchronization. A controller can then be coupled with the plant by means of synchronous composition. We confine our attention to controllers that interact with the system only through event synchronization. We present an initial investigation of synthesis of liveness controllers for hybrid machines. To this end we define open hybrid machines as systems that can interact with the environment through event synchronization and can be therefor be "driven" to their marked configuration by user (controller). Liveness specifications must be associated with timing constraints. We may require that for a specified time limit, every run reach a marked configuration within that time limit. Alternatively, a more relaxed specification may be that, for some (unspecified) global time bound, every run of the system reach a marked configuration within that time bound. Finally, the least restrictive liveness requirement is that every run reach a marked configuration within a finite time limit (but we do not insist on the existence of a global time bound for all runs).

Heymann, Michael↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung↗

Shuttle avionics system

The avionics system of the Space Shuttle is designed in a fail operational/fail safe architecture. The guidance, navigation and control system is implemented, through the onboard Orbiter digital computers. Guidance, navigation and control sensors are triplex, while the flight control effectors are mechanized either in load sharing or quad structure. Two sets of basic flight instruments and controls are provided along with electronic interfaces to allow for multiple selection of input destination and display source selection. Communications, tracking and instrumentation subsystems are mechanized as a dual hardware design for key operational elements. The data processing system allows for quad, triplex, dual or single computer operation. The power distribution subsystem provides a triple bus system with appropriate tie elements. A functional description is given of the computer system, the data bus, the mass memory unit, the multiplexer/demultiplexer and the CRT display system.

Gardiner, R. A.↗

Ultra-Compact Motor Controller

This invention is an electronically commutated brushless motor controller that incorporates Hall-array sensing in a small, 42-gram package that provides 4096 absolute counts per motor revolution position sensing. The unit is the size of a miniature hockey puck, and is a 44-pin male connector that provides many I/O channels, including CANbus, RS-232 communications, general-purpose analog and digital I/O (GPIO), analog and digital Hall inputs, DC power input (18-90 VDC, 0-l0 A), three-phase motor outputs, and a strain gauge amplifier. This controller replaces air cooling with conduction cooling via a high-thermal-conductivity epoxy casting. A secondary advantage of the relatively good heat conductivity that comes with ultra-small size is that temperature differences within the controller become smaller, so that it is easier to measure the hottest temperature in the controller with fewer temperature sensors, or even one temperature sensor. Another size-sensitive design feature is in the approach to electrical noise immunity. At a very small size, where conduction paths are much shorter than in conventional designs, the ground becomes essentially isopotential, and so certain (space-consuming) electrical noise control components become unnecessary, which helps make small size possible. One winding-current sensor, applied to all of the windings in fast sequence, is smaller and wastes less power than the two or more sensors conventionally used to sense and control winding currents. An unexpected benefit of using only one current sensor is that it actually improves the precision of current control by using the "same" sensors to read each of the three phases. Folding the encoder directly into the controller electronics eliminates a great deal of redundant electronics, packaging, connectors, and hook-up wiring. The reduction of wires and connectors subtracts substantial bulk and eliminates their role in behaving as EMI (electro-magnetic interference) antennas. A shared knowledge by each motor controller of the state of all the motors in the system at 500 Hz also allows parallel processing of higher-level kinematic matrix calculations.

Townsend, William T.↗

Initial Performance Results on IBM POWER6

The POWER5+ processor has a faster memory bus than that of the previous generation POWER5 processor (533 MHz vs. 400 MHz), but the measured per-core memory bandwidth of the latter is better than that of the former (5.7 GB/s vs. 4.3 GB/s). The reason for this is that in the POWER5+, the two cores on the chip share the L2 cache, L3 cache and memory bus. The memory controller is also on the chip and is shared by the two cores. This serializes the path to memory. For consistently good performance on a wide range of applications, the performance of the processor, the memory subsystem, and the interconnects (both latency and bandwidth) should be balanced. Recognizing this, IBM has designed the Power6 processor so as to avoid the bottlenecks due to the L2 cache, memory controller and buffer chips of the POWER5+. Unlike the POWER5+, each core in the POWER6 has its own L2 cache (4 MB - double that of the Power5+), memory controller and buffer chips. Each core in the POWER6 runs at 4.7 GHz instead of 1.9 GHz in POWER5+. In this paper, we evaluate the performance of a dual-core Power6 based IBM p6-570 system, and we compare its performance with that of a dual-core Power5+ based IBM p575+ system. In this evaluation, we have used the High- Performance Computing Challenge (HPCC) benchmarks, NAS Parallel Benchmarks (NPB), and four real-world applications--three from computational fluid dynamics and one from climate modeling.

Saini, Subbash↗

Ramp Traffic Console (RTC) and Ramp Manager Traffic Console (RMTC) User Manual

This document serves as a user manual for the ATD-2 Ramp Traffic Console (RTC) (version 5.11) utilized by the Ramp Control Tower. It describes the elements of the RTC interface and provides step-by-step instructions for using the tool. RTC provides live flight information, including, flight state and location, departure/arrival schedules, gate conflicts, Traffic Management Initiative (TMI) restrictions, and gate advisories to support Surface Time-Based Metering (STBM). RTC facilitates information sharing with the Air Traffic Control (ATC) Tower. This document also provides instructions for use of the Ramp Manager Traffic Console (RMTC) for Ramp Manager functions, such as managing the priority flight list and setting the ramp status. The RTC/RMTC ramp tools are components of the NASA Airspace Technology Demonstration 2 (ATD-2) sub-project.

Deborah Lee Bakowski↗

Method and apparatus for hybrid position/force control of multi-arm cooperating robots

Two or more robotic arms having end effectors rigidly attached to an object to be moved are disclosed. A hybrid position/force control system is provided for driving each of the robotic arms. The object to be moved is represented as having a total mass that consists of the actual mass of the object to be moved plus the mass of the moveable arms that are rigidly attached to the moveable object. The arms are driven in a positive way by the hybrid control system to assure that each arm shares in the position/force applied to the object. The burden of actuation is shared by each arm in a non-conflicting way as the arm independently control the position of, and force upon, a designated point on the object.

Hayati, Samad A.↗

A Vision of the Future Air Traffic Control System

The air transportation system is on the verge of gridlock, with delays and cancelled flights this summer reaching all time highs. As demand for air transportation continues to increase, the capacity needed to accommodate the growth in traffic is falling farther and farther behind. Moreover, it has become increasingly apparent that the present system cannot be scaled up to provide the capacity increases needed to meet demand over the next 25 years. NASA, working with the Federal Aviation Administration and industry, is pursuing a major research program to develop air traffic management technologies that have the ultimate goal of doubling capacity while increasing safety and efficiency. This seminar will describe how the current system operates, what its limitations are and why a revolutionary "shift in paradigm" is needed to overcome fundamental limitations in capacity and safety. For the near term, NASA has developed a portfolio of software tools for air traffic controllers, called the Center-TRACON Automation System (CTAS), that provides modest gains in capacity and efficiency while staying within the current paradigm. The outline of a concept for the long term, with a deployment date of 2015 at the earliest, has recently been formulated and presented by NASA to a select group of industry and government stakeholders. Automated decision making software, combined with an Internet in the sky that enables sharing of information and distributes control between the cockpit and the ground, is key to this concept. However, its most revolutionary feature is a fundamental change in the roles and responsibilities assigned to air traffic controllers.

Erzberger, Heinz↗

Digital Motion Imagery, Interoperability Challenges for Space Operations

With advances in available bandwidth from spacecraft and between terrestrial control centers, digital motion imagery and video is becoming more practical as a data gathering tool for science and engineering, as well as for sharing missions with the public. The digital motion imagery and video industry has done a good job of creating standards for compression, distribution, and physical interfaces. Compressed data streams can easily be transmitted or distributed over radio frequency, internet protocol, and other data networks. All of these standards, however, can make sharing video between spacecraft and terrestrial control centers a frustrating and complicated task when different standards and protocols are used by different agencies. This paper will explore the challenges presented by the abundance of motion imagery and video standards, interfaces and protocols with suggestions for common formats that could simplify interoperability between spacecraft and ground support systems. Real-world examples from the International Space Station will be examined. The paper will also discuss recent trends in the development of new video compression algorithms, as well likely expanded use of Delay (or Disruption) Tolerant Networking nodes.

Grubbs, Rodney↗

Fade Mitigation Techniques at Ka-Band

Rain fading is the dominant propagation impairment affecting Ka-band satellite links and rain fade mitigation is a key element in the design of Ka-band satellite networks. Some of the common fade mitigation techniques include: power control, diversity, adaptive coding, and resource sharing. The Advanced Communications Technology Satellite (ACTS) provides an excellent opportunity to develop and test Ka-band rain impairment amelioration techniques. Up-link power control and diversity are discussed in this paper.

Dissanayake, Asoka↗

Advanced Electric Distribution, Switching, and Conversion Technology for Power Control

The Electrical Power Control Unit currently under development by Sundstrand Aerospace for use on the Fluids Combustion Facility of the International Space Station is the precursor of modular power distribution and conversion concepts for future spacecraft and aircraft applications. This unit combines modular current-limiting flexible remote power controllers and paralleled power converters into one package. Each unit includes three 1-kW, current-limiting power converter modules designed for a variable-ratio load sharing capability. The flexible remote power controllers can be used in parallel to match load requirements and can be programmed for an initial ON or OFF state on powerup. The unit contains an integral cold plate. The modularity and hybridization of the Electrical Power Control Unit sets the course for future spacecraft electrical power systems, both large and small. In such systems, the basic hybridized converter and flexible remote power controller building blocks could be configured to match power distribution and conversion capabilities to load requirements. In addition, the flexible remote power controllers could be configured in assemblies to feed multiple individual loads and could be used in parallel to meet the specific current requirements of each of those loads. Ultimately, the Electrical Power Control Unit design concept could evolve to a common switch module hybrid, or family of hybrids, for both converter and switchgear applications. By assembling hybrids of a common current rating and voltage class in parallel, researchers could readily adapt these units for multiple applications. The Electrical Power Control Unit concept has the potential to be scaled to larger and smaller ratings for both small and large spacecraft and for aircraft where high-power density, remote power controllers or power converters are required and a common replacement part is desired for multiples of a base current rating.

Soltis, James V.↗

Controlling Distributed Planning

A system of software implements an extended version of an approach, denoted shared activity coordination (SHAC), to the interleaving of planning and the exchange of plan information among organizations devoted to different missions that normally communicate infrequently except that they need to collaborate on joint activities and/or the use of shared resources. SHAC enables the planning and scheduling systems of the organizations to coordinate by resolving conflicts while optimizing local planning solutions. The present software provides a framework for modeling and executing communication protocols for SHAC. Shared activities are represented in each interacting planning system to establish consensus on joint activities or to inform the other systems of consumption of a common resource or a change in a shared state. The representations of shared activities are extended to include information on (1) the role(s) of each participant, (2) permissions (defined as specifications of which participant controls what aspects of shared activities and scheduling thereof), and (3) constraints on the parameters of shared activities. Also defined in the software are protocols for changing roles, permissions, and constraints during the course of coordination and execution.

Clement, Bradley↗

Nocturnal lowering of thresholds for sweating and vasodilation

The effect of the time of day on the relation of the heat-dissipating responses (sweating and vasodilation) to esophageal and mean skin temperatures was investigated. These parameters were measured in six subjects exercised at 60-70% of maximal aerobic power in a 25 deg C ambient. Results indicate that a circadian rhythm in the thresholds for sweating and vasodilation can account for much of the rhythm of internal body temperature. The circadian rhythm in the operation of the thermoregulatory system seems to be expressed through a reference point shared by vasomotor and sudomotor controls.

Wenger, C. B.↗

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗