Search NASA⌕ Search

SEARCH · Search NASA

Results for “shield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Radiation Shielding Optimization on Mars

Future space missions to Mars will require radiation shielding to be optimized for deep space transit and an extended stay on the surface. In deep space, increased shielding levels and material optimization will reduce the exposure from most solar particle events (SPE) but are less effective at shielding against galactic cosmic rays (GCR). On the surface, the shielding provided by the Martian atmosphere greatly reduces the exposure from most SPE, and long-term GCR exposure is a primary concern. Previous work has shown that in deep space, additional shielding of common materials such as aluminum or polyethylene does not significantly reduce the GCR exposure. In this work, it is shown that on the Martian surface, almost any amount of aluminum shielding increases exposure levels for humans. The increased exposure levels are attributed to neutron production in the shield and Martian regolith as well as the electromagnetic cascade induced in the Martian atmosphere. This result is significant for optimization of vehicle and shield designs intended for the surface of Mars.

Slaba, Tony C.↗

Composite Aerogel Multifoil Protective Shielding

New technologies are needed to survive the temperatures, radiation, and hypervelocity particles that exploration spacecraft encounter. Multilayer insulations (MLIs) have been used on many spacecraft as thermal insulation. Other materials and composites have been used as micrometeorite shielding or radiation shielding. However, no material composite has been developed and employed as a combined thermal insulation, micrometeorite, and radiation shielding. By replacing the scrims that have been used to separate the foil layers in MLIs with various aerogels, and by using a variety of different metal foils, the overall protective performance of MLIs can be greatly expanded to act as thermal insulation, radiation shielding, and hypervelocity particle shielding. Aerogels are highly porous, low-density solids that are produced by the gelation of metal alkoxides and supercritical drying. Aerogels have been flown in NASA missions as a hypervelocity particle capture medium (Stardust) and as thermal insulation (2003 MER). Composite aerogel multifoil protective shielding would be used to provide thermal insulation, while also shielding spacecraft or components from radiation and hypervelocity particle impacts. Multiple layers of foil separated by aerogel would act as a thermal barrier by preventing the transport of heat energy through the composite. The silica aerogel would act as a convective and conductive thermal barrier, while the titania powder and metal foils would absorb and reflect the radiative heat. It would also capture small hypervelocity particles, such as micrometeorites, since it would be a stuffed, multi-shock Whipple shield. The metal foil layers would slow and break up the impacting particles, while the aerogel layers would convert the kinetic energy of the particles to thermal and mechanical energy and stop the particles.

Jones, Steven M.↗

Analytical-HZETRN Model for Rapid Assessment of Active Magnetic Radiation Shielding

The use of active radiation shielding designs has the potential to reduce the radiation exposure received by astronauts on deep-space missions at a significantly lower mass penalty than designs utilizing only passive shielding. Unfortunately, the determination of the radiation exposure inside these shielded environments often involves lengthy and computationally intensive Monte Carlo analysis. In order to evaluate the large trade space of design parameters associated with a magnetic radiation shield design, an analytical model was developed for the determination of flux inside a solenoid magnetic field due to the Galactic Cosmic Radiation (GCR) radiation environment. This analytical model was then coupled with NASA's radiation transport code, HZETRN, to account for the effects of passive/structural shielding mass. The resulting model can rapidly obtain results for a given configuration and can therefore be used to analyze an entire trade space of potential variables in less time than is required for even a single Monte Carlo run. Analyzing this trade space for a solenoid magnetic shield design indicates that active shield bending powers greater than 15 Tm and passive/structural shielding thicknesses greater than 40 g/cm2 have a limited impact on reducing dose equivalent values. Also, it is shown that higher magnetic field strengths are more effective than thicker magnetic fields at reducing dose equivalent.

Washburn, S. A.↗

Analytic Ballistic Performance Model of Whipple Shields

The dual-wall Whipple shield is the shield of choice for lightweight, long-duration flight. The shield uses an initial sacrificial wall to initiate fragmentation and melt an impacting threat that expands over a void before hitting a subsequent shield wall of a critical component. The key parameters to this type of shield are the rear wall and its mass which stops the debris, as well as the minimum pressure generated under threat particle impact of the sacrificial wall and the amount of void that is available for expansion. Ensuring the minimum pressure is sufficiently high to achieve large scale fragmentation/melt of the threat particle enables the expansion of the threat and reduces the momentum flux of the debris on the rear wall. Three key factors in the minimum pressure achieved are the thickness of the sacrificial wall relative to the characteristic dimension of the impacting particle, the density and material cohesion contrast of the sacrificial wall relative to the threat particle and the impact speed. The mass of the rear wall and the sacrificial wall are desirable to minimize for launch costs and dynamic concerns making it important to have an understanding of the effects of density contrast and impact speed. In this paper a fourth key parameter is identified related to fragmentation, which corresponds to the ratio of the size of the projectile relative to the transition from brittle to ductile hole growth in the projectile. Ballistic limit equations have been developed to define the failure limits of a MMOD shield, generally in terms of projectile diameter (or mass), impact velocity, and angle. Within the range of impact velocities relevant for Earth-orbiting spacecraft, three distinct regions of penetration phenomenology have been identified for Whipple shields: center dot Low velocity: the projectile is eroded (and possibly deformed) during its passage through the bumper plate, but is not fragmented. Thus, perforation of the rear wall is by a fragment with a mass and speed equal to or less than the original impactor. center dot Intermediate (shatter) velocity: impact velocities are sufficient to induce projectile fragmentation upon impact with the bumper plate, resulting in a coarse debris cloud with large solid fragments. Increasing velocity within the shatter regime results in increased fragmentation, and eventually melting, of the projectile and bumper fragments, generating a finer and more evenly dispersed debris cloud. Failure of the rear wall is a complicated combination of modes observed at low- and hypervelocity. center dot Hypervelocity: the projectile and holed-out bumper material is completely, or nearly completely, melted and/or vaporized by the initial impact. The resultant debris cloud impacts over a dispersed area of the rear wall, loading it impulsively and inducing failure through rupture or petalling. While each of these regimes are well observed with extensive empirical methods to describe these regions, differences in impactor materials, configurations of shields and questions about the limitations of the attainable impact speeds have left questions that are difficult to answer from completely empirical methods.

Miller, J. E.↗

Open Rotor Noise Shielding by Blended-Wing-Body Aircraft

This paper presents an analysis of open rotor noise shielding by Blended Wing Body (BWB) aircraft by using model scale test data acquired in the Boeing Low Speed Aeroacoustic Facility (LSAF) with a legacy F7/A7 rotor model and a simplified BWB platform. The objective of the analysis is the understanding of the shielding features of the BWB and the method of application of the shielding data for noise studies of BWB aircraft with open rotor propulsion. By studying the directivity patterns of individual tones, it is shown that though the tonal energy distribution and the spectral content of the wind tunnel test model, and thus its total noise, may differ from those of more advanced rotor designs, the individual tones follow directivity patterns that characterize far field radiations of modern open rotors, ensuring the validity of the use of this shielding data. Thus, open rotor tonal noise shielding should be categorized into front rotor tones, aft rotor tones and interaction tones, not only because of the different directivities of the three groups of tones, but also due to the differences in their source locations and coherence features, which make the respective shielding characteristics of the three groups of tones distinctly different from each other. To reveal the parametric trends of the BWB shielding effects, results are presented with variations in frequency, far field emission angle, rotor operational condition, engine installation geometry, and local airframe features. These results prepare the way for the development of parametric models for the shielding effects in prediction tools.

Guo, Yueping↗

Accelerator shield design of KIPT neutron source facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of a neutron source facility at KIPT utilizing an electron-accelerator-driven subcritical assembly. Electron beam power is 100 kW, using 100 MeV electrons. The facility is designed to perform basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The biological shield of the accelerator building is designed to reduce the biological dose to less than 0.5-mrem/hr during operation. The main source of the biological dose is the photons and the neutrons generated by interactions of leaked electrons from the electron gun and accelerator sections with the surrounding concrete and accelerator materials. The Monte Carlo code MCNPX serves as the calculation tool for the shield design, due to its capability to transport electrons, photons, and neutrons coupled problems. The direct photon dose can be tallied by MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is less than 0.01 neutron per electron. This causes difficulties for Monte Carlo analyses and consumes tremendous computation time for tallying with acceptable statistics the neutron dose outside the shield boundary. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were developed for the study. The generated neutrons are banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron and secondary photon doses. The weight windows variance reduction technique is utilized for both neutron and photon dose calculations. Two shielding materials, i.e., heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary at less than 0.5-mrem/hr. The shield configuration and parameters of the accelerator building have been determined and are presented in this paper. (authors)

43 PARTICLE ACCELERATORS↗

Experimental and numerical study of the shielding effect of two tandem rough cylinders in flow-induce oscillation

The shielding effect of the downstream cylinder in flow induced oscillation (FIO) of two cylinders arranged in tandem is studied experimentally and numerically at Reynolds number 30,000 to 120,000. Both cylinders are in one degree-of-freedom, transverse-oscillations, and have turbulence stimulation in the form of selective surface roughness to expand FIO beyond vortex-induced vibration (VIV) into galloping. Shielding of the downstream cylinder has a negative effect on harnessing hydrokinetic energy. Further, to study its effect and mechanics, selective cases are studied both numerically and experimentally and discussed to demonstrate the shielding effect on the downstream cylinder and understand its cause. The main conclusions are: (1) The shielding effect for the downstream cylinder shows a strong relation to the damping ratio. As the damping ratio increases, the shielding effect is mitigated. Additionally, the oscillation of the rear cylinder becomes stable and shows stable frequency. (2) In the VIV region, as the stiffness and natural frequency increase, the shielding effect decreases substantially. (3) In the VIV region, the vorticity of the vortices shedding from both the upper and the lower sides of the downstream cylinder does not accumulate enough due to the attraction by the vortices shed from the upstream cylinder, thus resulting in partial suppression of the oscillation on the downstream cylinder. (4) In the galloping region, the shielding effect for the downstream cylinder depends on whether the vorticity near the downstream cylinder is strengthened by the vortices generated by the shear layers of the upstream cylinder or weakened.

42 ENGINEERING↗

Simple shielding reduces dose to the contralateral breast during prone breast cancer radiotherapy

Our goal was to design a prone breast shield for the contralateral breast and study its efficacy in decreasing scatter radiation to the contralateral breast in a prone breast phantom setup receiving radiation therapy designed for breast cancer. We constructed a prone breast phantom setup consisting of (1) A thermoplastic mask with a left-sided depression created by a water balloon for a breast shape; (2) 2 plastic bags to hold water in the thermoplastic mask depression; (3) 2000 mL of water to fill the thermoplastic mask depression to create a water-based false breast; (4) 1-cm thick bolus placed in the contralateral breast holder; (5) 2 lead (Pb) sheets, each 0.1-cm thick for blocking scatter radiation in the contralateral bolus-based false breast; (6) a prone breast board to hold the thermoplastic mask, water, bolus, and lead; (7) 9 cm solid water on top of the breast board to simulate body; (8) a diode was used to verify dose for each treatment field of the treated water-based breast; (9) metal–oxide–semiconductor-field effect transistor (MOSFET) dosimeters to measure dose to the contralateral bolus-based breast. The phantom prone breast setup was CT simulated and treatment was designed with 95% isodose line covering the treated breast. The maximum dose was 107.1%. Megavoltage (MV) port images ensured accurate setup. Measurements were done using diodes on the treated water-based breast and MOSFET dosimeters at the medial and lateral sides of the contralateral bolus-based breast without and with the Pb shield. Five treatments were done for each of the 3 data sets and recorded individually for statistical purposes. All treatments were completed with 6 MV photons at 200 cGy per treatment. The dose contributions from each of the 3 data sets including 15 treatments total without and with the prone lead shield to the medial and lateral portions of contralateral bolus-based breast were averaged individually. Unshielded dose means were 37.11 and 2.94 cGy, and shielded dose means were 12.68 and 1.54 cGy, respectively. When comparing medial and lateral portions of the contralateral bolus-based doses without and with Pb, the shield significantly reduced dose to both sides of the contralateral breast (medial p = 2.64 × 10{sup −14}, lateral p = 4.91 × 10{sup −6}). The prone 0.2-cm Pb shield significantly reduced scatter dose to the contralateral breast on the order of 2 to 3 times. Reductions may be clinically relevant for women younger than 45 years by decreasing the risk of contralateral radiation-induced breast cancer in patients receiving radiation therapy for breast cancer. This shield is simple as it would be a part of the prone breast board during treatments, but future studies are warranted for safety and efficacy clinically.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of magnetic noise from conductive shields in the 10–300 kHz frequency range

Here we present experimental and theoretical investigations of magnetic noise originating from radio-frequency (RF) conductive shields of flat geometry in the inductance-dominated impedance regime below 300 kHz. The measurement is based on a Q-factor determination of a coil that provides a sufficient sensitivity, placed at the position where the shield magnetic noise is measured. The theory is based on calculations of magnetic field and inductance of one or a few flat rings that emulate a conductive shield. The theoretical model is found to be in close agreement with experimental data. It can be used to predict the magnetic noise of a conductive shield with different thicknesses, conductivities, and temperatures at different distances for a wide range of frequencies. Although the model can be generalized for a more arbitrary shield geometry, in its presented form, it can be applied to the magnetic noise predictions when the shield surface curvature is not large. One important conclusion is that the RF conductive shield can generate the magnetic noise much lower than femtotesla, and, thus, it can be used in many precision experiments targeting minute high-frequency magnetic signals, such as detection of magnetic resonance imaging and nuclear quadrupole resonance signals and search for axion dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Optimization of a Multilayered Shield for Transportable Microreactors

The ability to easily transport microreactors is a major selling point for deploying microreactors to remote areas. However, this creates a unique shielding challenge, especially when the microreactor is being shipped after irradiation. A traditional reactor configuration utilizes a separate biological shield and pressure vessel to meet radiological shielding and pressure needs. The limited space available for transportable microreactors for both shielding and pressure vessels requires a revised assessment of separating out the biological shield and pressure vessel. To address these concerns, we examine a nuclear-grade sandwich composite (NGSC) that combines the reactor pressure vessel and biological shielding functions into a single component. Through a series of optimization problems for both transportation and operational use cases, the NGSC is able to minimize dose, minimize the vessel cost, and ensure that weight requirements are met for transportation. Initial results show that using a tungsten-tetraboride cermet in the first two layers of a six-layer NGSC provides adequate shielding for both use cases. These results show promise that an NGSC has enough overlap between operational and transportation cases to help reduce the design space for future analysis and assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer

Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A{sup 3})], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR {sup 192}Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR {sup 192}Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A{sup 3} may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extraterrestrial Regolith Derived Atmospheric Entry Heat Shields

High-mass planetary surface access is one of NASAs technical challenges involving entry, descent and landing (EDL). During the entry and descent phase, frictional interaction with the planetary atmosphere causes a heat build-up to occur on the spacecraft, which will rapidly destroy it if a heat shield is not used. However, the heat shield incurs a mass penalty because it must be launched from Earth with the spacecraft, thus consuming a lot of precious propellant. This NASA Innovative Advanced Concept (NIAC) project investigated an approach to provide heat shield protection to spacecraft after launch and prior to each EDL thus potentially realizing significant launch mass savings. Heat shields fabricated in situ can provide a thermal-protection system for spacecraft that routinely enter a planetary atmosphere. By fabricating the heat shield with space resources from materials available on moons and asteroids, it is possible to avoid launching the heat-shield mass from Earth. Regolith has extremely good insulating properties and the silicates it contains can be used in the fabrication and molding of thermal-protection materials. In this paper, we will describe three types of in situ fabrication methods for heat shields and the testing performed to determine feasibility of this approach.

Heat↗

Concepts and Tests for the Remote-Controlled Dismantling of the Biological Shield and Form work of the KNK Reactor - 13425

The compact sodium-cooled nuclear reactor facility Karlsruhe (KNK), a prototype Fast Breeder, is currently in an advanced stage of dismantling. Complete dismantling is based on 10 partial licensing steps. In the frame of the 9. decommissioning permit, which is currently ongoing, the dismantling of the biological shield is foreseen. The biological shield consists of heavy reinforced concrete with built-in steel fitments, such as form-work of the reactor tank, pipe sleeves, ventilation channels, and measuring devices. Due to the activation of the inner part of the biological shield, dismantling has to be done remote-controlled. During a comprehensive basic design phase a practical dismantling strategy was developed. Necessary equipment and tools were defined. Preliminary tests revealed that hot wire plasma cutting is the most favorable cutting technology due to the geometrical boundary conditions, the varying distance between cutter and material, and the heavy concrete behind the steel form-work. The cutting devices will be operated remotely via a carrier system with an industrial manipulator. The carrier system has expandable claws to adjust to the varying diameter of the reactor shaft during dismantling progress. For design approval of this prototype development, interaction between manipulator and hot wire plasma cutting was tested in a real configuration. For the demolition of the concrete structure, an excavator with appropriate tools, such as a hydraulic hammer, was selected. Other mechanical cutting devices, such as a grinder or rope saw, were eliminated because of concrete containing steel spheres added to increase the shielding factor of the heavy concrete. Dismantling of the biological shield will be done in a ring-wise manner due to static reasons. During the demolition process, the excavator is positioned on its tripod in three concrete recesses made prior to the dismantling of the separate concrete rings. The excavator and the manipulator carrier system will be operated alternately. Main boundary condition for all the newly designed equipment is the decommissioning housing of limited space within the reactor building containment. To allow for a continuous removal of the concrete rubble, an additional opening on the lowest level of the reactor shaft will be made. All equipment and the interaction of the tools have to be tested before use in the controlled area. Therefore a full-scale model of the biological shield will be provided in a mock-up. The tests will be performed in early 2014. The dismantling of the biological shield is scheduled for 2015. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of lump characteristics on self-shielding corrections of active neutron interrogation on fissile material in waste - 15405

Non-destructive active neutron assay techniques such as active neutron coincidence counting, differential die away analysis or the californium shuffler method rely on the interrogation of fissile nuclear materials by an external neutron source. Whether it is a spontaneous fission or (α,n) neutron source, like {sup 252}Cf or AmLi; or a fusion neutron generator, all of these techniques rely on induced secondary fission events to provide prompt or delayed neutron signals that serve as the basis for the fissile material quantification. The accuracy of these fissile mass measurements is therefore dependent on the neutron interrogation efficiencies determined for calibration reference standards and whether the measured items are comparable to the calibration condition. In such favorable conditions, it is possible to establish a reliable empirical non-linear relationship between apparent (uncorrected) and real or true fissile mass. However, in waste measurements, this is unlikely to be the case; thus a calibration approach that takes account of the neutron self-shielding effect is required. By incorporating the Self-Shielding Factor (SSF) of the calibration reference standards, a linear mass calibration factor [s{sup -1}. {sup 239}Pu{sub eq} g{sup -1}] can be found; this calibration is accurate for waste in which the fissile material is 'infinitely dilute' i.e. the waste exhibits no self-shielding; this is assumed to be representative of dispersed material. The self-shielding correction and its systematic uncertainty are then left to be treated as part of the Total Measurement Uncertainty (TMU) evaluation associated with the assay result. The derivation of the TMU contribution associated with the self-shielding effect in nuclear waste is a complex problem for which a reliable evaluation has to be performed. This is usually based on assuming 'worst case scenarios' for the distribution of material that can arise in a particular waste stream. Such an approach is conservative, but often very penalizing, especially if one considers larger lumps (those containing grams of fissile material); for such lumps, the self-shielding correction becomes very significant, potentially altering the mass of {sup 239}Pu{sub eq} by over an order of magnitude. A worst case 'nuclear safety value' may not be the most appropriate choice for building a consignment best estimate or repository sentencing value for an item. In the present work the authors describe a numerical approach to study the variability of neutron self-shielding factors associated with distributions of a wide range of lump characteristics in terms of size, shape, chemical composition, density and isotopic composition. The described novel calculation tool is capable of accurately predicting the real impact of random distribution of lumps in a waste material, and allowed to show that given reasonable, defensible, assumptions on the composition of the lumps in waste stream, the systematic error component of the DDA TMU can be significantly reduced. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The New Modular High-Energy X-ray Source Facility Shielding Design

Several new research facilities will soon be constructed as part of the creation of a new engineering complex on the campus of the University of Tennessee, Knoxville (UTK). As part of this renovation, a state of the art nuclear engineering building will be constructed. This building will include a critical experiment facility, a graphite pile, and a modular high-energy X-ray source (or accelerator facility). The proximity of these new facilities to UTK's football stadium brings heightened attention to their design and safety. An important aspect of this specific design is that shielding is required to contain the new radiation sources. The work completed will reflect the specific project planning and novel two-story facility design of the modular high-energy X-ray source. It will also provide a detailed shielding and dose analysis of the facility as a whole. The end design places an accelerator into a well-shielded room; it will then direct the x-ray beam through a collimating hole in the shielding wall into the next room. The x-ray beam is to be used as a part of a materials irradiation and imaging laboratory in the adjoining room. The design satisfies all regulatory requirements, and it will serve as the preliminary facility layout design and shielding analysis for a novel two-story modular high energy X-ray source facility. The dose rates calculated by the Monte Carlo models using the NCRP shielding thickness values are well below the dose limitations set by the State of Tennessee, which leaves room for optimization. Further work could be done to complete the optimization by reducing the shielding thickness while maintaining a dose below dose regulations by using a less conservative method for calculating the initial thicknesses. (authors)

43 PARTICLE ACCELERATORS↗

Upper mantle structure under western Saudi Arabia from Rayleigh wave tomography and the origin of Cenozoic uplift and volcanism on the Arabian Shield

The shear velocity structure of the shallow upper mantle beneath the Arabian Shield has been modeled by inverting new Rayleigh wave phase velocity measurements between 45 and 140 s together with previously published Rayleigh wave group velocity measurement between 10 and 45 s. For measuring phase velocities, we applied a modified array method that minimizes the distortion of raypaths by lateral heterogeneity. The new shear velocity model shows a broad low velocity region in the lithospheric mantle across the Shield and a low velocity region at depths {ge} 150 km localized along the Red Sea coast and Makkah-Madinah-Nafud (MMN) volcanic line. The velocity reduction in the upper mantle corresponds to a temperature anomaly of {approx}250-330 K. These finding, in particular the region of continuous low velocities along the Red Sea and MMN volcanic line, do not support interpretations for the origin of the Cenozoic plateau uplift and volcanism on the Shield invoking two separate plumes. When combined with images of the 410 and 660 km discontinuities beneath the southern part of the Arabian Shield, body wave tomographic models, a S-wave polarization analysis, and SKS splitting results, our new model supports an interpretation invoking a thermal upwelling of warm mantle rock originating in the lower mantle under Africa that crosses through the transition zone beneath Ethiopia and moves to the north and northwest under the eastern margin of the Red Sea and the Arabian Shield. In this interpretation, the difference in mean elevation between the Platform and Shield can be attributed to isostatic uplift caused by heating of the lithospheric mantle under the Shield, with significantly higher region along the Red Sea possibly resulting from a combination of lithosphere thinning and dynamic uplift.

58 GEOSCIENCES↗

Regolith Biological Shield for a Lunar Outpost from High Energy Solar Protons

Beyond Earth atmosphere, natural space radiation from Galactic Cosmic Rays and Solar Energetic Protons (SEPs) represents a significant hazard to both manned and robotic missions. For lunar settlements, protecting astronauts from SEPs is a key safety issue that needs to be addressed by identifying appropriate shielding materials. This paper investigates the interaction of SEPs with the lunar regolith, and quantifies the effectiveness of the regolith as a biological shield for a human habitat, compared to aluminum, presently the standard shielding material. Also calculated is the shielding thickness to reduce the dose in the habitat to those recommended by International Radiation Protection Committee and by NASA for operation on the international space station. The present calculations are for the most energetic solar event of February 1956, which included high energy protons up to 1000 MeV. Results show that the lunar regolith is as effective as aluminum for shielding lunar outposts. A large thickness of the regolith ({approx}30 g/cm{sup 2}) would be needed to reduce the dose in the habitat from high energy protons below the 30 days flight crew limit of 25 Rem (or 250 mSv) and significantly more shielding would be needed ({approx}150 g/cm{sup 2}) to reduce the dose down to the limit for radiation workers of 5 Rem (or 50 mSv)

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Advanced shield development for a fission surface power system for the lunar surface

A nuclear reactor power system such as the affordable fission surface power system enables a potential outpostonthemoon.Aradiation shieldmustbe included in the reactor system to reduce the otherwise excessive dose to the astronauts and other vital system components. The radiation shield is typically the most massive component of a space reactor system, and thus must be optimized to reduce mass asmuchas possible while still providing the required protection.Various shield options for an on-lander reactor system are examined for outpost distances of 400m and 1 kmfromthe reactor. Also investigated is the resulting mass savings from the use of a high performance cermet fuel. A thermal analysis is performed to determine the thermal behaviours of radiation shields using borated water. For an outpost located 1000m from the core, a tetramethylammonium borohydride shield is the lightest (5148.4 kg), followed by a trilayer shield (boron carbide–tungsten–borated water; 5832.3 kg), and finally a borated water shield (6020.7 kg). In all of the final design cases, the temperature of the borated water remains below 400 K.

42 ENGINEERING↗