Search NASA⌕ Search

SEARCH · Search NASA

Results for “shot optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Utilization of the CW magnetrons as coherent RF sources for superconducting RF accelerators

CW magnetrons designed and optimized for industrial heaters, driven by an injection-locking signal, were suggested to power Superconducting RF (SRF) cavities. However, the CW magnetrons, which are regenerative generators, are intended to operate in self-excitation mode, so, for reliable starting they use a large regenerative gain, causing a large regenerative instability in operation. Thus, power supply ripple, even shot noise, etc., lead to multiple sidebands forming a quasi-continuous noise spectrum at the carrier frequency. Therefore, in the traditionally used mode of operation and control, such magnetrons are inapplicable for powering high Q-factor SRF cavities. A new approach to operation and control of CW magnetrons considering non-stationary processes during start-up and operation makes it possible to find a mode of almost coherent RF generation of tubes with a significant reduction in regenerative instability and noise and increased efficiency. In our work is presented substantiation for the newly developed mode with an analysis of the new approach based on experimental results. •In this article, for the first time, non-stationary, regenerative processes are considered during the start-up and operation of CW magnetrons for powering high-Q superconducting RF cavities.•An analytical study, confirmed by experiments, showed that the traditionally used modes of starting and operating CW magnetrons are not suitable for powering high-Q superconducting RF cavities.•In fact, to make CW magnetrons suitable for such cavities, the physics of starting and operating CW magnetrons must be changed. This has been demonstrated in our work.•In developing the Stimulated Coherent Generation Mode [NIM A 980 (2020) 164366], we have shown the suitability of this mode for starting and operating CW magnetrons for high-Q superconducting RF cavities.•Analytical analysis, verified experimentally, substantiates in our article the suitability of the “Mode of stimulated coherent generation” of CW magnetrons for powering high-Q superconducting cavities in pulsed and continuous modes.

43 PARTICLE ACCELERATORS↗

Achievable noise performance of spectroscopic prototype DEPFET detectors

A new generation of spectroscopic X-ray DEPFET detectors has been produced here in the course of the detector development for the Wide Field Imager (WFI) of Athena. These devices served to perform a detailed analysis of the noise composition, which was enabled by the development of appropriate test algorithms. A result of the analysis is the distinction of different components, which sum up to the total noise. In particular the contribution of shot noise, white noise and 1/f noise to the readout noise is determined as well as the signal noise caused by the generation of charge carriers. The resulting parametrization enables the adaptation and optimization of operation modes to given purposes. The studied prototype detectors included 64×64 pixels with a linear gate design and provided an excellent noise, below 1.6 e - ENC at a readout time faster than 10 μs/pixel and a temperature of -80 °C in rolling-shutter operation. This performance is enabled by an extended signal integration time. A further noise reduction is prevented by the signal noise, caused by charge carrier generation. In order to demonstrate the low noise properties of the DEPFET transistor, the measurement conditions were adapted and a noise of 0.95 e - ENC was measured at the expense of the sensor size—by operating only parts of the sensor in window mode—and dynamic range—by using the Al Kα line at about 1.49 keV for calibration.

47 OTHER INSTRUMENTATION↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS↗

Effect of Surface Self-Nanocrystallization on Diffusion Bonding Between a Titanium Alloy and a TiAl-Based Alloy

A self-nanocrystallization layer was prepared on the surface of a Ti alloy sample via shot peening to investigate its influence on the follow-up diffusion bonding between a titanium alloy and a TiAl-based alloy. The experiment results show that surface self-nanocrystallization treatment can accelerate the interface reaction between a Ti alloy and a TiAl alloy, lowering the bonding temperature of the sound joints by more than 50 K. Moreover, the thickness of the interface reaction layer plays an important role in the interfacial bonding strength. In this work, the maximum shear strength of the joint appears to have a thickness of about 1.8 μm. As a consequence, it is found that surface self-nanocrystallization treatment is helpful for optimizing the diffusion bonding process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bayesian batch optimization for molybdenum versus tungsten inertial confinement fusion double shell target design

Access to reliable, clean energy sources is a major concern for national security. Much research is focused on the “grand challenge” of producing energy via controlled fusion reactions in a laboratory setting. For fusion experiments, specifically inertial confinement fusion (ICF), to produce sufficient energy, the fusion reactions in the ICF fuel need to become self-sustaining and burn deuterium-tritium (DT) fuel efficiently. The recent record-breaking NIF ignition shot was able to achieve this goal as well as produce more energy than used to drive the experiment. This achievement brings self-sustaining fusion-based power systems closer than ever before, capable of providing humans with access to secure, renewable energy. In order to further progress toward the actualization of such power systems, more ICF experiments need to be conducted at large laser facilities such as the United States's National Ignition Facility (NIF) or France's Laser Mega-Joule. The high cost per shot and limited number of shots that are possible per year make it prohibitive to perform large numbers of experiments. As such, experimental design relies heavily on complex predictive physics simulations for high-fidelity “preshot” analysis. These multidimensional, multi-physics, high-fidelity simulations have to account for a variety of input parameters as well as modeling the extreme conditions (pressures and densities) present at ignition. Such simulations (especially in 3D) can become computationally prohibitive to turn around for each ICF experiment. In this work, we explore using Bayesian optimization with Gaussian processes (GPs) to find optimal designs for ICF double shell targets, while keeping computational costs to manageable levels. These double shell targets have an inner shell that grades from beryllium on the outer surface to the higher Z material molybdenum, as opposed to the nominally used tungsten, on the inside in order to trade off between the high performance associated with high density inner shells and capsule stability. We describe our results for “capsule-only” xRAGE simulations to study the physics between different capsule designs, inner shell materials, and potential for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

XFEL diffraction: Developing processing methods to optimize data quality

Serial crystallography, using either femtosecond X-ray pulses from free-electron laser sources or short synchrotron-radiation exposures, has the potential to reveal metalloprotein structural details while minimizing damage processes. However, deriving a self-consistent set of Bragg intensities from numerous still-crystal exposures remains a difficult problem, with optimal protocols likely to be quite different from those well established for rotation photography. Here several data processing issues unique to serial crystallography are examined. It is found that the limiting resolution differs for each shot, an effect that is likely to be due to both the sample heterogeneity and pulse-to-pulse variation in experimental conditions. Shots with lower resolution limits produce lower-quality models for predicting Bragg spot positions during the integration step. Also, still shots by their nature record only partial measurements of the Bragg intensity. An approximate model that corrects to the full-spot equivalent (with the simplifying assumption that the X-rays are monochromatic) brings the distribution of intensities closer to that expected from an ideal crystal, and improves the sharpness of anomalous difference Fourier peaks indicating metal positions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent efforts of vapour-phase strategies for EUV resist toward high- and hyper-NA extreme ultraviolet lithography

Extreme ultraviolet lithography (EUVL, λ = 13.5 nm) is critical for sub-1 nm technology nodes but remains constrained by inherent trade-offs among resolution, line-edge roughness (LER), and sensitivity. Stochastic effects originating from photon shot noise, low-energy secondary electron blur, and the random distribution of resist components further limit its advancement toward high numerical-aperture (NA, NA = 0.55) and hyper-NA (NA ≥0.75) EUVL. While the optimization of spin-on chemically amplified resists (CARs) continues, metal-oxide resists (MORs) have emerged as strong candidates for next-generation EUVL by incorporating metals with high EUV absorption coefficients, which enhances both resist sensitivity and etch resistance during pattern transfer. Besides spin-coating, recent advances in vapour-phase techniques, such as vapour-phase infiltration (VPI), chemical vapour deposition (CVD), and molecular atomic layer deposition (MALD), offer promising pathways to achieve new resist platforms, such as dry resists, that satisfy the stringent thickness and uniformity requirements of next-generation EUVL. These methods enable the direct incorporation of metal species into existing resist matrices or the formation of hybrid inorganic–organic resist platforms, thereby improving film uniformity, etch durability, and pattern fidelity while mitigating stochastic defects. This review highlights the latest advancements in vapour-phase-synthesized EUV resists, emphasizing material design, lithographic performance, and the underlying exposure mechanisms. Although still emerging, vapour-phase strategies are paving the way for an all-dry integration framework that could improve EUV patterning workflows and meet the demands of future technology nodes.

36 MATERIALS SCIENCE↗

Intense High-Contrast Femtosecond K-Shell X-Ray Source from Laser-Driven Ar Clusters

Bright Ar quasimonochromatic K-shell x ray with very little background has been generated using an Ar clustering gas jet target irradiated with a 30 fs ultrahigh-contrast laser, with a measured flux of 2.2x10{sup 11} photons/J into 4{pi}. This intense x-ray source critically depends on the laser contrast and intensity. The optimization of source output with interaction length is addressed. Simulations point to a nonlinear resonant mechanism of electron heating during the early stage of laser interaction, resulting in enhanced x-ray emission. The x-ray pulse duration is expected to be only 10 fs, opening the possibility for single-shot ultrafast keV x-ray imaging applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a novel, short pulse laser-driven neutron source

We present a full characterization of a short pulse laser-driven neutron source. Neutrons are produced by nuclear reactions of laser-driven ions deposited in a secondary target. The emission of neutrons is a superposition of an isotropic component into 4π and a forward directed, jet-like contribution, with energies ranging up to 80 MeV. A maximum flux of 4.4 × 10{sup 9} neutrons/sr has been observed and used for fast neutron radiography. On-shot characterization of the ion driver and neutron beam has been done with a variety of different diagnostics, including particle detectors, nuclear reaction, and time-of-flight methods. The results are of great value for future optimization of this novel technique and implementation in advanced applications.

07 ISOTOPE AND RADIATION SOURCES↗

Astrophysics & cosmology from line intensity mapping vs galaxy surveys

Line intensity mapping (LIM) proposes to efficiently observe distant faint galaxies and map the matter density field at high redshift. Building upon the formalism in a companion paper, we first highlight the degeneracies between cosmology and astrophysics in LIM. We discuss what can be constrained from measurements of the mean intensity and redshift-space power spectra. With a sufficient spectral resolution, the large-scale redshift-space distortions of the 2-halo term can be measured, helping to break the degeneracy between bias and mean intensity. With a higher spectral resolution, measuring the small-scale redshift-space distortions disentangles the 1-halo and shot noise terms. Additionally, cross-correlations with external galaxy catalogs or lensing surveys further break degeneracies. We derive requirements for experiments similar to SPHEREx, HETDEX, CDIM, COMAP and CONCERTO. We then revisit the question of the optimality of the LIM observables, compared to galaxy detection, for astrophysics and cosmology. We use a matched filter to compute the luminosity detection threshold for individual sources. We show that LIM contains information about galaxies too faint to detect, in the high-noise or high-confusion regimes. We quantify the sparsity and clustering bias of the detected sources and compare them to LIM, showing in which cases LIM is a better tracer of the matter density. We extend previous work by answering these questions as a function of Fourier scale, including for the first time the effect of cosmic variance, pixel-to-pixel correlations, luminosity-dependent clustering bias and redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Transformer-powered surrogates close the ICF simulation-experiment gap with extremely limited data

Abstract Recent advances in machine learning, specifically transformer architecture, have led to significant advancements in commercial domains. These powerful models have demonstrated superior capability to learn complex relationships and often generalize better to new data and problems. This paper presents a novel transformer-powered approach for enhancing prediction accuracy in multi-modal output scenarios, where sparse experimental data is supplemented with simulation data. The proposed approach integrates transformer-based architecture with a novel graph-based hyper-parameter optimization technique. The resulting system not only effectively reduces simulation bias, but also achieves superior prediction accuracy compared to the prior method. We demonstrate the efficacy of our approach on inertial confinement fusion experiments, where only 10 shots of real-world data are available, as well as synthetic versions of these experiments.

97 MATHEMATICS AND COMPUTING↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized Quantum Compilation for Near-Term Algorithms with OpenPulse

Quantum computers are traditionally operated by programmers at the granularity of a gate-based instruction set. However, the actual device-level control of a quantum computer is performed via analog pulses. Here, we introduce a compiler that exploits direct control at this microarchitectural level to achieve significant improvements for quantum programs. Unlike quantum optimal control, our approach is bootstrapped from existing gate calibrations and the resulting pulses are simple. Our techniques are applicable to any quantum computer and realizable on current devices. We validate our techniques with millions of experimental shots on IBM quantum computers, controlled via the OpenPulse control interface. For representative benchmarks, our pulse control techniques achieve both 1.6x lower error rates and 2x faster execution time, relative to standard gate-based compilation. These improvements are critical in the near-term era of quantum computing, which is bottlenecked by error rates and qubit lifetimes.

Gokhale, Pranav↗

Active meta-learning for predicting and selecting perovskite crystallization experiments

Autonomous experimentation systems use algorithms and data from prior experiments to select and perform new experiments in order to meet a specified objective. In most experimental chemistry situations, there is a limited set of prior historical data available, and acquiring new data may be expensive and time consuming, which places constraints on machine learning methods. Active learning methods prioritize new experiment selection by using machine learning model uncertainty and predicted outcomes. Meta-learning methods attempt to construct models that can learn quickly with a limited set of data for a new task. Here in this paper, we applied the model-agnostic meta-learning (MAML) model and the Probabilistic LATent model for Incorporating Priors and Uncertainty in few-Shot learning (PLATIPUS) approach, which extends MAML to active learning, to the problem of halide perovskite growth by inverse temperature crystallization. Using a dataset of 1870 reactions conducted using 19 different organoammonium lead iodide systems, we determined the optimal strategies for incorporating historical data into active and meta-learning models to predict reaction compositions that result in crystals. We then evaluated the best three algorithms (PLATIPUS and active-learning k-nearest neighbor and decision tree algorithms) with four new chemical systems in experimental laboratory tests. With a fixed budget of 20 experiments, PLATIPUS makes superior predictions of reaction outcomes compared to other active-learning algorithms and a random baseline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancement of Optical Emission and Ion Currents in a Laser Produced Silicon Plasma by Femtosecond Laser-Induced Periodic Surface Structuring

Laser-induced periodic surface structuring is a powerful technique for modifying the surface properties of solids. Using ultrashort pulses from a Ti:Sapphire laser (800 nm, 100 fs) we have fabricated nanoscale order laser-induced periodic surface structures (LIPSS) on a silicon (100) surface. The LIPSS patterns are found to be strongly dependent on the laser pulse energy, state of polarization, number of shots delivered on the target, and the ambient pressure. The role of laser wavelength is studied by using the second harmonic output (400 nm) also for fabrication. Large area (5x4 mm2) surface structuring has been carried out at atmospheric pressure after optimizing the laser parameters at 800 nm. The patterned silicon surface shows a substantial reduction in the reflection of incident light over a wide range of wavelengths, in comparison to plain silicon. Moreover, when used for laser induced breakdown spectroscopy (LIBS) experiments, enhanced optical emission and ion current have been observed from the patterned surface. This indicates that coupling of laser energy to the surface is enhanced in the case of patterned silicon. While spectral lines emitted by doubly ionized silicon have been observed from the patterned surface, the plain surface gives lines from singly ionized silicon only. A discernible enhancement has been measured in both optical (50-90%) and electrical (34%) signals from the plasma generated on the patterned surface. These results confirm that LIPSS is a versatile method for enhancing the coupling of laser energy on to irradiated solid surfaces.

ion currents, optical emission, laser produced sil↗