Correlation of airloads on a two-bladed helicopter rotor

Airloads measured on a two-bladed helicopter rotor in flight, from the Tip Aerodynamic and Acoustic Test, are compared with calculations from a comprehensive helicopter analysis (CAMRAD/JA), and the pressures compared with calculations from a full-potential rotor code (FPR). The flight test results cover an advance ratio range from 0.19 to 0.38. The lowest speed case is characterized by the presence of significant blade-vortex interactions. Good correlation of peak-to-peak vortex-induced loads and the corresponding pressures is obtained. The results of the correlation for this two-bladed rotor are substantially similar to the results for three- and four-bladed rotors, concerning the tip vortex core size for best correlation, calculation of the peak-to-peak loads on the retreating side, and calculation of vortex-induced loads on inboard radial stations.

Hernandez, Francisco↗

Simulation and dynamic performance of a 20-kHz spacecraft power system

A candidate 20-kHz spacecraft power system which includes a series-parallel combination of four Mapham inverters connected to several types of loads is described. A computer simulation of the power system is used to illustrate its steady-state and dynamic performance on an end-to-end basis. Comparisons with measured data are made. It is shown that significant distortion of the 20-kHz bus voltage can occur due to the switching of the load converters. This distortion can be reduced by including a shunt-connected parallel resonant filter on the 20-kHz side of the load converter. It is also shown that the distortion can be reduced by using a pulse-density-modulated switching strategy.

Wasynczuk, O.↗

Development of a Thermo-Electric Cooler Simulation Routine for the Wide Field Camera 3 Thermal Model

A SINDA subroutine has been developed to predict the power generated by a Thermo-Electric Cooler (TEC). A TEC can be described analytically by relations between four parameters: cold side temperature, hot side temperature, parasitic heat load, and electrical power. The subroutine requires the user to input the hot side and cold side temperatures, the corresponding parasitic heat load, and coefficients describing the vendor performance curves. The subroutine then utilizes an iterative solution scheme and vendor TEC performance curves for specific hardware to determine the current (and consequently the TEC power) that satisfies these requirements. This paper provides an in-depth discussion of the algorithm employed in the subroutine, implementation of the subroutine in the HST Wide Field Camera 3 thermal model, and the evaluation of the subroutine performance against actual test/correlation data.

Peabody, Hume↗

Maglev crude oil pipeline

This maglev crude oil pipeline consists of two conduits guiding an endless stream of long containers. One conduit carries loaded containers and the other empty returns. The containers are levitated by permanent magnets in repulsion and propelled by stationary linear induction motors. The containers are linked to each other in a manner that allows them, while in continuous motion, to be folded into side by side position at loading and unloading points. This folding causes a speed reduction in proportion to the ratio of container diameter to container length. While in side by side position, containers are opened at their ends to be filled or emptied. Container size and speed are elected to produce a desired carrying capacity.

Knolle, Ernst G.↗

A Domain Decomposition Parallelization of the Fast Marching Method

In this paper, the first domain decomposition parallelization of the Fast Marching Method for level sets has been presented. Parallel speedup has been demonstrated in both the optimal and non-optimal domain decomposition case. The parallel performance of the proposed method is strongly dependent on load balancing separately the number of nodes on each side of the interface. A load imbalance of nodes on either side of the domain leads to an increase in communication and rollback operations. Furthermore, the amount of inter-domain communication can be reduced by aligning the inter-domain boundaries with the interface normal vectors. In the case of optimal load balancing and aligned inter-domain boundaries, the proposed parallel FMM algorithm is highly efficient, reaching efficiency factors of up to 0.98. Future work will focus on the extension of the proposed parallel algorithm to higher order accuracy. Also, to further enhance parallel performance, the coupling of the domain decomposition parallelization to the G(sub 0)-based parallelization will be investigated.

Herrmann, M.↗

An Investigation of Passive and Semi-Active Tuned Mass Dampers for a Tension Leg Platform Floating Offshore Wind Turbine in ULS Conditions

Offshore Wind Turbines (OWTs) are subjected to complex external loadings caused by combined wind and wave sources. The application of structural damping control techniques to OWTs using Tuned Mass Dampers (TMDs) has shown to be effective in reducing the integrated system loads and accelerations. In this work, the impact of passive and semi-active (S-A) TMD’s applied to both fixed-bottom (monopile) and floating (tension leg platform) OWTs are evaluated under the Fatigue Limit State (FLS) and Ultimate Limit State (ULS). Different S-A control logics like ON/OFF state damping based on the ground hook (GH) control policy are implemented, and the frequency response of each algorithm is investigated. It is shown that the performance of each algorithm varies according to the load conditions such as FLS (normal operation) and ULS (idling state). Fully-coupled time domain simulations are conducted through the developed simulation tool for structural control integrated into the high-fidelity wind turbine design code, FASTv8. Compared to the passive TMD, it is shown that a S-A TMD results in higher load reductions, as well as, smaller strokes under both FLS and ULS conditions. In FLS analysis, the S-A TMD using Displacement Based Ground Hook (DB-GH) control is capable of reducing the fore-aft and side-to-side damage equivalent loads for the monopile substructure by approximately 12 % and 64 %, respectively. The ultimate loads at the tower base for the floating substructure (TLP) are also reduced by 9% with S-A TMD followed by Inverse Velocity Based Ground Hook control (IVB-GH). The dynamic characteristics and practical feasibility of a magnetorheological (MR) damper (for S-A control) are also evaluated.

17 WIND ENERGY↗

Gear tooth stress measurements of two helicopter planetary stages

Two versions of the planetary reduction stages from U.S. Army OH-58 helicopter main rotor transmissions were tested at NASA Lewis. One sequential and one nonsequential planetary were tested. Sun gear and ring gear teeth strains were measured, and stresses were calculated from the strains. The alternating stress at the fillet of both the loaded and unloaded sides of the teeth and at the root of the sun gear teeth are reported. Typical stress variations as the gear tooth moves through mesh are illustrated. At the tooth root location of the thin rimmed sun gear, a significant stress was produced by a phenomenon other than the passing of a planet gear. The load variation among the planets was studied. Each planet produced its own distinctive load distribution on the ring and sun gears. The load variation was less for a three planet, nonsequential design as compared to that of a four planet, sequential design. The reported results enhance the data base for gear stress levels and provide data for the validation of analytical methods.

Krantz, Timothy L.↗

Design and implementation of coupled thermomechanical failure experiments.

Coupled thermal-mechanical experiments with well-defined, controlled boundary conditions were designed through an iterative process involving a team of experimentalists, material modelers and computational analysts. First the basic experimental premise was selected: an axisymmetric tubular specimen mechanically loaded by internal pressurization and thermally loaded asymmetrically by side radiant heating. Then several integrated experimental-analytical steps were taken to determine the experimental details. The boundary conditions were mostly thermally driven and were chosen so they could be modeled accurately; the experimental fixtures were designed to ensure that the boundary conditions were met. Preliminary, uncoupled analyses were used to size the specimen diameter, height and thickness with experimental consideration of maximum pressure loads and fixture design. Iterations of analyses and experiments were used to efficiently determine heating parameters including lamp and heating shroud design, set off distance between the lamps and shroud and between the shroud and specimen, obtainable ramp rates, and the number and spatial placement of thermocouples. The design process and the experimental implementation of the final coupled thermomechanical failure experiment design will be presented.

42 ENGINEERING↗

Fundamental damper power calculation of the 56MHz SRF cavity for RHIC

At each injection period during RHIC's operation, the beam's frequency sweeps across a wide range, and some of its harmonics will cross the frequency of the 56MHz SRF cavity. To avoid excitation of the cavity at these times, we designed a fundamental damper for the quarter-wave resonator to damp the cavity heavily. The power extracted by the fundamental damper should correspond to the power handling ability of the system at all stages. In this paper, we discuss the power output from the fundamental damper when it is fully extracted, inserted, and any intermediate point. A Fundamental Damper (FD) will greatly reduce the cavity's Q factor to {approx}300 during the acceleration phase of the beam. However, when the beam is at store and the FD is removed, the cavity is excited by both the yellow and the blue beams at 2 x 0.3A to attain the required 2MV voltage across its gap. The cavity then is operated to increase the luminosity of the RHIC experiments. Table 1 lists the parameters of the FD. Figure 1 shows the configuration of the FD fully inserted into the 56MHz SRF cavity; this complete insertion is defined as the start location (0cm) of FD simulation, an assumption we make throughout this paper. The power consumed by the cavity while maintaining the beam's energy and its orbit is compensated by the 28MHz accelerating cavities in the storage ring. The power dissipation of the external load is dynamic with respect to the position of the FD during its extraction. As a function of the external Q and the EM field in the cavity, the power should peak with the FD at a certain vertical location. Our calculation of the power extracted is detailed in the following sections. Figure 2 plots the frequency change in the cavity, and the external Q against the changes in position of the FD. The location of the FD is selected carefully such that the frequency will approach the designed working point from the lower side only. The loaded Q of the cavity is 223 when the FD is fully inserted. The simulation was carried out with Microwave Studio 2010.

43 PARTICLE ACCELERATORS↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Polarization loss correction derived from hydrogen local-resistance measurement in low Pt-loaded polymer-electrolyte fuel cells

The reduction of platinum-loading on the cathode side of polymer-electrolyte fuel cells leads to a poorly understood increase in mass-transport resistance (MTR) at high current densities. This local resistance was measured using a facile hydrogen-pump technique with dilute active gases for membrane-electrode assemblies with catalyst layers of varying platinum-loading (0.03-0.40 mgPt/cm²). Furthermore, polarization curves in H 2 /air were measured and corrected for the overpotential caused by the increased MTR for low loadings on the air side due to the reduced concentration of reactant gas at the catalyst surface. The difference in performance after correction for all resistances including the MTR is minor, suggesting its origin to be diffusive in nature, and proving the meaningfulness of the facile hydrogen-pump technique for the characterization of the cathode catalyst layer under defined operation conditions.

30 DIRECT ENERGY CONVERSION↗

First-principles study of hydrogen storage on Ti-decorated B{sub 2}C sheet

The hydrogen storage capacity of Ti decorated B{sub 2}C sheet has been investigated by first-principles plane-wave calculation. It is revealed that a single Ti atom adsorbed on the B{sub 2}C sheet can strongly bind up to four hydrogen molecules. The adsorption energy is in the range of -0.36--0.82 eV/H{sub 2}, which is suitable for ambient temperature hydrogen storage. Considering the fact that Ti can be loaded on both sides of B{sub 2}C sheet, corresponding gravimetric storage capacity of Ti/B{sub 2}C system was also calculated and it can reach to about 7.0 wt%, exceeding the minimum requirement of 6.0 wt% for applications. - Graphical abstract: We investigated the hydrogen storage capacity of Ti decorated B{sub 2}C sheet. The most favorable adsorption geometries for every number of hydrogen molecules on Ti/B{sub 2}C complex are given in the figure. Highlights: Black-Right-Pointing-Pointer Ti decorated B{sub 2}C sheet serve as hydrogen storage medium. Black-Right-Pointing-Pointer A single Ti atom adsorbed on the B{sub 2}C sheet can strongly bind up to four hydrogen molecules. Black-Right-Pointing-Pointer The adsorption energy is in moderate range of -0.36--0.82 eV/H{sub 2}.

36 MATERIALS SCIENCE↗

Online distributed price-based control of DR resources with competitive guarantees

Demand response (DR) of building HVAC load can provide crucial demand-side flexibility for the future smart grid. Compared to direct load control, price-based control can respect the customers’ autonomy and privacy. However, it is challenging for price-based control to attain provable performance guarantees under future uncertainty. In this paper, we propose a framework for a utility to perform price-based control of flexible building load within the utility’s service area, in order to attain competitive performance guarantees in terms of controlling the system peak demand under future uncertainty. By adopting a two-step approach, our online price-based control solution can attain a provable competitive ratio for all possible realizations within a given uncertainty set. Simulation experiments demonstrate that, with a robustification procedure, our solution can perform well not only for worst-case inputs, but also for average-case inputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of pressure waves

Two parameters, side on overpressure and side on impulse loads, and their application to the determination of structural damage to buildings and vehicles in the vicinity of an explosion are investigated. Special consideration was given to what constitutes damage and what level of damage is acceptable. Solutions were sorted through the examination of glass breakage, curve fit to bomb damage, overturning of marginal structures (buses, trucks, mobile homes) subject to toppling, and initiation of yielding in either beam or plate structural components. Three different empirical pressure versus impulse diagrams were presented - the first is for minor structural damage involving wrenched joints and partitions, the second is for major damage structural damage with load bearing members at least partially destroyed, and the third is for 50% to 75% of the building demolished. General guidelines were obtained from the results when the accurate structural details are unknown.

Source record↗

Improved Apparatus for Testing Monoball Bearings

A desk-sized apparatus for testing monoball bearings and their lubricants offers advantages, relative to prior such apparatuses, of (1) a greater degree of automation and (2) capability of operation under wider and more realistic ranges of test conditions. The ranges of attainable test conditions include load from 100 to greater h than 50,000 lb (445 to greater than 2.22 x 10(exp 5) N), resisting torque up to 30,000 lb-in. (approximately equal to 3,390 N-m), oscillating rotation through an angle as large as 280 degrees, and oscillation frequency from 0 to 6 Hz. With addition of some components and without major modification of the apparatus, it is also possible to perform tests under environmental conditions that include temperature from -320 to 1,000 F (-196 to +538 C), relative humidity from 0 to 100 percent, and either air at ambient pressure, high vacuum, or an atmosphere of monatomic oxygen. In the apparatus (see Figure 1), a monoball bearing specimen is driven in oscillating rotation by a hydraulic rotary actuator through a series of shafts, one of which incorporates a torque meter and one of which is a flexible coupling. The torque meter measures the resisting torque; the flexible coupling accommodates misalignment, wear, and compression of the specimen and ensures equal loading on opposite sides of the monoball. Not shown in the figure is an angular-position sensor that is used for measuring the angle of rotation of the shafts.

Hall, Phillip B.↗

Effects of bearing deadbands on bearing loads and rotor stability

The Jeffcott model of a turbopump which was modified by adding deadband (clearance) effects along with fluid seal forces are currently understood. Equations of motion for the model were written in polar coordinates, and a constant side force was added to the model to account for the likely misalignment between bearings and seals. The force models and system equations of motion are described as well as limit cycle, and stability analyses. Studies of systems with rotor imbalance and with or without side effects were studied for three types of motion. Results show that: (1) deadband does not affect stability-in-the-large; (2) stability-in-the small is enhanced by deadband and side force; (3) bearings loads are highest for motion with synchronous or nonsynchronous periodic enclosing origin; (4) side force acting in concert with deadband effects may either increase or decrease bearing loads; and (5) bearing loads in a stable pump are determined primarily by rotor imbalance and side forces.

Glaese, J. R.↗

Real-time sensor measurements to evaluate impacts of load cycling on high-temperature fire-side corrosion in a PC boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Survey of U.S. Ancillary Services Markets

In addition to providing energy to end-consumers, power system operators are also responsible for ensuring system reliability. To this end, power markets maintain an array of ancillary services to ensure that it is always possible to balance the supply and demand for energy in real-time. A subset of these ancillary services are commonly procured through market-based mechanisms: namely, Regulation, Spinning, and Non-spinning Reserves. Regulation Reserves are maintained to respond to supply/demand imbalances over short time frames, typically on the order of several seconds to one minute. Resources that provide Regulation Reserves adjust their generation or load levels in response to automatic generation control (AGC) signals provided by the system operator. Contingency reserves are maintained to provide additional generation capacity in the event that load increases substantially or supply side resources reduce their output or are taken offline. The reserves are typically segmented into two categories, 1) Spinning or Synchronized Reserves that are provided by generation units that are actively generating and have the ability to increase or decrease their output, 2) Non-spinning or Non-synchronized Reserves that are provided by generation resources that are not actively generating, but are able to start up and provide generation within a specified timeframe. Contingency reserves typically have response times on the order of ten to 30 minutes and can also be provided by demand-side resources that are capable of reducing their load. There are seven distinct power markets in the United States, each operated by a Regional Transmission Operator (RTO) or Independent System Operator (ISO) that operates the transmission system in its territory, operates markets for energy and ancillary services, and maintains system reliability. Each power market offers its own set of ancillary services, and precise definitions, requirements, and market mechanisms differ between markets. Despite the differences between markets, both in terms of services offered and system requirements, some broad trends generally apply. Regulation Reserves typically have the highest market prices, followed by Spinning Reserves and Non-spinning Reserves. Prices for Regulation Reserves have been the highest in the PJM market, since it opened in October 2012. This is partially because PJM experienced large price spikes during the period of extreme weather conditions in early 2014. ERCOT has traditionally had the highest prices for Spinning Reserves (called Responsive Reserves in ERCOT), including several periods of sustained high prices between 2010 and 2012. This can be explained in part by the relatively high penetration of variable wind resources and a similarly high requirement relative to peak load. ERCOT has also traditionally had the highest price for Non-spinning Reserves, followed by the NYISO East region. Both have experienced several periods of prolonged high prices since their inception, an occurrence that has not been regularly seen in other markets. In ISO-NE and PJM for example, the market clearing price for Non-spinning Reserves is typically $0/MWh more than 95% of the time. Market volume (in terms of the average amount of capacity of each service that is provided to a system) typically follows the reverse order of prices, as systems maintain the most Non-spinning Reserves capacity followed by Spinning Reserves and Regulation Reserves. PJM generally has the largest market for Regulation Reserves both in terms of capacity. The size of most Regulation Reserves markets in terms of capacity stay relatively constant year-to-year, as this is dictated largely by system requirements. PJM also generally has the largest Spinning Reserves market in terms of capacity. SPP, MISO, ISO-NE and SPP (beginning in 2014) all have Spinning Reserve markets with similar average capacity levels. When combined, the markets for Non-spinning and Operating reserves in ISO-NE have a comparable capacity to the market for Primary Reserves 1 in PJM. SPP, MISO, and CAISO all have smaller markets for their respective Non-spinning Reserves products that are roughly the same size as each other in terms of capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗