Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulation facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fast and flexible control of beam longitudinal phase space for high-repetition-rate x-ray free-electron lasers

The wide-ranging requirements for the photon properties from multiple beamlines in superconducting based free-electron lasers (FELs) demand more challenging beam manipulation techniques. Shot-by-shot control of electron beam bunch length and peak current at high repetition rate up to megahertz is highly desired. In this paper, we present a comprehensive study of a method based on a 2-m-long normal conducting radio-frequency cavity to achieve fast and flexible control of beam compression and realize the full potential of the facility, including theoretical analysis, beam dynamics simulations, and conceptual cavity design for the Linac Coherent Light Source II and its high-energy upgrade. We illustrate the physical mechanism of the chirping cavity on the control of the final beam compression and propose methods to lower the requirements for the cavity parameters. The application of this method will allow tailored photon properties of individual beamlines to optimize their performance and drastically improve the multiplexing capabilities of a high-repetition rate FEL facility.

42 ENGINEERING↗

Finding a common ground for RCM experiments. Part B: Benchmark study on ethanol ignition

Rapid compression machines (RCMs) are widely used to investigate gas phase reaction kinetics of various kind of fuels at application relevant conditions. In principle, the operation of an RCM is based on the idea of compressing a homogenous pre-mixed fuel-air mixture by a piston. Usually creviced pistons ensure a homogenous adiabatic core in the center of the reaction chamber which permits the assumption of an isentropic relation between the measured pressure and gas temperature. Despite the ideal core gas compression, non-ideal effects such as heat loss, differences in the compression behavior, and ultimately non-standardized design and operation of rapid compression machines lead to different experimental results in different facilities at nominally the same end of compression conditions. In this study ignition delay times of ethanol are investigated at four different conditions in five independent RCMs. As expected, the raw results of the different facilities indeed show notable differences at the same end of compression conditions. However, according to the adiabatic core hypothesis the agreement between kinetic simulations and experiments should be consistent for all facilities provided that the facility effects are correctly accounted for. To elaborate upon this hypothesis, a kinetic mechanism is optimized to reflect the experimental results of all facilities. In the end, the optimized mechanism predicts all experimental data within the expected uncertainty. This confirms the reliability of RCM experiments for kinetic investigations and the validity of the effective volume approach in simulating RCM data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wrought FeCrAl alloy (C26M) cladding behavior and burst under simulated loss-of-coolant accident conditions

Cladding burst experiments for FeCrAl cladding were performed in the Severe Accident Test Station facility at Oak Ridge National Laboratory. These experiments were simulated using the BISON fuel performance code to better understand the cladding plastic behavior and failure under simulated loss-of-coolant accident conditions. 3D cladding surface boundary conditions were generated using composite axial and azimuthal profiles from experiment thermocouple data. To improve the simulation analysis capabilities in BISON for cladding burst behavior, new thermal creep, plasticity, and failure stress models specific to C26M, a wrought FeCrAl alloy, were developed and implemented. Initial cladding burst results indicated a general underprediction in the failure temperature of the six cladding burst simulations versus the observed failure temperatures. Close investigation of the experiment timing versus the underlying tensile test data revealed that, compared with the tensile specimens, the cladding tubes did not experience the same long holding time at high temperatures. New tensile tests were performed at high temperatures using a temperature ramp similar to the simulated loss-of-coolant accident experiments. These new tensile curves showed an approximately 80% increase in the ultimate tensile strength of the C26M alloy, indicating that a holding time of 10 min at 700 °C and 800 °C allows annealing to change the material microstructure. Using the updated tensile properties, the burst temperatures and stresses from the simulations showed remarkable agreement with the experimental results. This study was then extended by varying the initial pressure to highlight the burst temperature difference between standard Zircaloy-4 and C26M cladding under equivalent conditions. The results show that C26M has a burst temperature that is approximately 70–130 K greater than that of Zircaloy-4. In conclusion, these modeling predictions can be further improved by collecting high-temperature tensile data for C26M beyond the temperature ranges used in this work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laboratory and field studies of ice-nucleating particles from open-lot livestock facilities in Texas

Abstract. In this work, an abundance of ice-nucleating particles (INPs) from livestock facilities was studied through laboratory measurements from cloud-simulation chamber experiments and field investigation in the Texas Panhandle. Surface materials from two livestock facilities, one in the Texas Panhandle and another from McGregor, Texas, were selected as dust proxies for laboratory analyses. These two samples possessed different chemical and biological properties. A combination of aerosol interaction and dynamics in the atmosphere (AIDA) measurements and offline ice spectrometry was used to assess the immersion freezing mode ice nucleation ability and efficiency of these proxy samples at temperatures above −29 ∘C. A dynamic filter processing chamber was also used to complement the freezing efficiencies of submicron and supermicron particles collected from the AIDA chamber. For the field survey, periodic ambient particle sampling took place at four commercial livestock facilities from July 2017 to July 2019. INP concentrations of collected particles were measured using an offline freezing test system, and the data were acquired for temperatures between −5 and −25 ∘C. Our AIDA laboratory results showed that the freezing spectra of two livestock dust proxies exhibited higher freezing efficiency than previously studied soil dust samples at temperatures below −25 ∘C. Despite their differences in composition, the freezing efficiencies of both proxy livestock dust samples were comparable to each other. Our dynamic filter processing chamber results showed on average approximately 50 % supermicron size dominance in the INPs of both dust proxies. Thus, our laboratory findings suggest the importance of particle size in immersion freezing for these samples and that the size might be a more important factor for immersion freezing of livestock dust than the composition. From a 3-year field survey, we measured a high concentration of ambient INPs of 1171.6 ± 691.6 L−1 (average ± standard error) at −25 ∘C for aerosol particles collected at the downwind edges of livestock facilities. An obvious seasonal variation in INP concentration, peaking in summer, was observed, with the maximum at the same temperature exceeding 10 000 L−1 on 23 July 2018. The observed high INP concentrations suggest that a livestock facility is a substantial source of INPs. The INP concentration values from our field survey showed a strong correlation with measured particulate matter mass concentration, which supports the importance of size in ice nucleation of particles from livestock facilities.

58 GEOSCIENCES↗

Detailed simulations of the first deuterium-tritium-filled double shell implosions on the National Ignition Facility

The first indirectly driven, liquid DT-filled double shell inertial confinement fusion (ICF) implosions have recently been successfully performed on the National Ignition Facility (NIF). Double shells are a class of alternative designs that use a low-Z outer shell to compress a foam cushion that accelerates a high-Z inner shell to efficiently compress a liquid DT core. Double shells are challenging to fabricate, field, and model. Important engineering features enabling double shell fabrication include a fill-tube penetrating all shells and a carefully designed and very narrow (few μm) step-joint in the ablator. Due to the higher density materials involved, high Atwood number instabilities are also important at many material interfaces. In this paper, numerical simulations of double shell implosions using the Los Alamos National Laboratory multi-physics radiation-hydrodynamics code xRAGE will be discussed. An extensive effort has been under way for several years to develop the code capabilities for ICF simulations in a common modeling framework to allow ease of simulation setup and standardization of the computational methodology. This paper will present a wide range of simulation results capturing, quantifying, and comparing the impact of all these degradation mechanisms on implosion performance. Brief comparisons with recent experimental results and suggestions for future improvements will also be discussed. Our results suggest that capsule surface roughness and the step-joint gap have the largest impact on implosion performance. Initial experimental data may suggest that the sensitivity to the step-joint gap could provide the dominant explanation for DT-filled double shell experiments that have been fielded on NIF thus far.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation

A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstrated in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which constitutes the core content of the metrics and diagnostics package in section 2, and a user's guide documenting the workflow/structure of the version 1.0 codes, and including step-by-step instruction for running the package in section 3.

54 ENVIRONMENTAL SCIENCES↗

Edge and scrape-off layer modeling for a Fusion Nuclear Science Facility with tungsten walls; a summary report for 2019-21

This report summarizes model development and simulations for the edge/scrape-off layer (SOL) region of a Fusion Nuclear Science Facility (FNSF) as part of the DOE Fusion Energy Systems Studies project. An overview of the FNSF device is given in Ref. 1. Our earlier related modeling of FNSF in the 2015-16 timeframe is reported in Ref. 2, and similar work on the ARIES ACT-1 tokamak device is described in Ref. 3. During 2017-18, we contributed to the analysis of a liquid lithium wall for FNSF [4].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory-Scale Melter Systems for Simulated and Real AP-107 Tank Waste - 20483

The Hanford Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. At the WTP, the tank waste will be combined with glass-forming and modifying additives to form an aqueous and solid mixture called melter feed, which will then be vitrified in joule-heated melters. A small-scale melter system, the continuous laboratory-scale melter (CLSM), is designed to operate with a continuous feeding process while periodically pouring glass product and collecting off-gas. Two CLSMs were constructed: one in a non-radioactive environment for processing waste simulants and another in a fume hood capable of handling radioactive material for processing actual Hanford tank waste. The waste sample received for vitrification in the CLSM was from Hanford tank 241-AP-107. Approximately 12 liters of melter-feed slurry was vitrified into 7 kilograms of glass product over the course of 10 hours of charging to the CLSM. The partitioning of technetium-99 in the product streams was used to calculate the technetium-99 recovery and help determine when the vitrification process had reached a steady state. The average single-pass retention of technetium-99 in the glass product was then calculated for the processing of AP-107 waste in the CLSM system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Expanding Activity Allocation Models to Daily Activities: Tracking Simulated Agent Trips to Exercise Locations in Clarksville, TN

Exercise facilities have been proven to have numerous physical, mental, and psychological benefits, yet exercise facilities are still inaccessible to a large portion of the population. This study serves to explore the accessibility of fitness centres through geographical, demographic, and temporal lenses through an expansion of the UrbanPop framework that seeks to allocate simulated agents to fitness centres in the Clarksville metro to explore the effects of travel distances on different demographics throughout the week. Findings indicate that senior and retired demographics consistently travel longer distances to exercise in the larger Clarksville area, likely due to tendencies to live further from the center of the metropolitan area. Furthermore, all demographics tend to travel further distances to exercise on the weekends rather than the weekdays, indicating that travel distance can affect likelihood of agents to travel, especially on weekdays when many agents are in the workforce or participating in schooling.

99 GENERAL AND MISCELLANEOUS↗

Tool for Developing Integrated Strategies for Decontamination and Waste Management - 20291

Management of waste from chemical, biological, and radiological incidents is complicated by the fact that decontamination decisions have a profound impact on the characteristics of resulting waste streams. Wide-area biological and radiological incidents could produce massive quantities of waste that may need to be treated on-site and sent for subsequent disposal as non-contaminated materials, or else be directly disposed of as contaminated materials. The EPA has developed the Waste Estimation Support Tool (WEST) for characterizing and quantifying biological and radiological waste that may be generated from decontamination efforts. This paper focuses on the WEST's uses for radiological incidents. WEST combines Geographic Information System (GIS)-based analysis of externally-supplied plume data, infrastructure databases derived from the Federal Emergency Management Agency's (FEMA's) Hazus tool [1], and satellite imagery surface recognition algorithms to combine the composition and square footage of the buildings in the plume with estimates of the materials between the buildings in the plume. The resulting GIS data files are then imported into a Microsoft Access database application, where they are combined with information about the nature and concentration of contaminants, and then subjected to decontamination strategies for different contaminated surfaces. The tool provides estimates of the type and quantities of potential wastes resulting from simulated decontamination and/or demolition activities and includes estimates of the remaining contamination levels including residual contamination contained within each waste stream. Estimates are presented at several levels of detail, allowing users to obtain needed data at the desired resolution. These include estimates for the total affected area, estimates by contamination zone, estimates by decontamination method(s), and estimates by building type (occupancy classification). EPA is currently developing the next version of WEST which will include several substantial enhancements. The most significant improvement for the next version of WEST will include the ability for users to develop contamination scenarios and waste estimates based on previously developed, readily available, and geographically specific infrastructure data. Instead of using WEST's default infrastructure data based on FEMA's Hazus tool, users will be able to import their own building data specific to the geographically affected area. This capability may substantially decrease uncertainties in the resulting waste estimates because the results will be based on actual building data (numbers of each type, square footage, building height, etc.). Two other significant enhancements will be the ability to generate waste estimates for vehicles and biomass. In addition to building debris and building decontamination waste, vehicles and biomass will likely constitute a significant percentage of the total waste which may result from wide area contamination events. This presentation will present the most recent version of WEST, which includes such considerations as affected biomass (e.g., trees), vehicles, and the ability to replace the default Hazus infrastructure databases with custom infrastructure databases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer Based Hydrogen Production Facility

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at NREL's Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN↗

Computational Risk Analysis of Propane Releases in Maintenance Facilities

Liquefied petroleum gas (LPG) is a viable, cleaner alternative to traditional diesel fuel used in busses and other heavy-duty vehicles and could play a role in helping the US meet its lower emission goals. While the LPG industry has focused efforts on developing vehicles and fueling infrastructure, we must also establish safe parameters for maintenance facilities which are servicing LPG fueled vehicles. Current safety standards aid in the design of maintenance facilities, but additional quantitative analysis is needed to prove safeguards are adequate and suggest improvements where needed. In this report we aim to quantify the amount of flammable mass associated with propane releases from vehicle mounted fuel vessels within enclosed garages. Furthermore, we seek to qualify harm mitigation with variable ventilations and facility layout. To accomplish this we leverage validated computational resources at Sandia National Laboratories to simulate various release scenarios representative of real world vehicles and maintenance facilities. Flow solvers are used to predict the dynamics of fuel systems as well as the evolution of propane during release events. From our simulated results we observe that both inflow and outflow ventilation locations play a critical role in reducing flammable cloud size and potential overpressure values during a possible combustion event.

03 NATURAL GAS↗

NREL Stratus - Enabling Workflows to Fuse Data Streams, Modeling, Simulation, and Machine Learning

Integrating cloud services into advanced computing facilities provides significant new capabilities over focusing solely on traditional high performance computing (HPC) workloads. This brings complementary capabilities as well as enabling new focused roles for HPC. They are especially potent for workflows that fuse data streams, modeling and simulation ('modsim') and machine learning. A key challenge to adopting a hybrid edge-cloud-HPC model is to align optimal capability, data, and user intent on the right resources for each step in a workflow.?The NREL Stratus service provides a basis for this: Stratus layers capabilities needed to make?cloud services accessible to a lab-based scientific community on commercial offerings, and; currently supports upwards of 200 projects ranging from IOT integration to traditional modeling and simulation. This provides a real-world inventory of scientific workflow elements. A growing knowledge base enables placing these elements appropriately between the edge, cloud, and traditional HPC. This paper outlines a vision via reference architecture and the application of that architecture in a typical workflow highlighting multiple components: sensor data intake, cleaning and transforming (edge/cloud suitable); generation of synthetic data through modsim, computationally heavy ML training and hyperparameter optimization (HPC suitable), and; inference and deployment (cloud ideal). Every step in such a workflow involves a cost-benefit analysis regarding the data movement, computational efficiency, availability, latency, and resource capabilities. The reference architecture and examples outlined allow for understanding new opportunities in the context of emerging workflows that combine IOT, cloud, and HPC to bolster scientific productivity.

AI↗

Tailoring Interfaces in Solid-State Batteries Using Interfacial Thermochemistry and Band Alignment

Solid-state lithium ion batteries have enhanced thermal stability compared to batteries using liquid electrolytes. Although their practical implementation is limited by undesired side reactions between the electrode and electrolyte, different modification strategies have been proposed to stabilize these reactive interfaces. These approaches have been primarily based upon bulk materials properties, however, which may not necessarily be representative of the chemistry at the solid/solid interface. In this work, first principles calculations and X-ray scattering experiments are used to elucidate molecular-level reactivity and develop design principles for tailored interfaces based on surface and interfacial properties. Because of its well-known instability, the interface between the Li metal anode and the lithium lanthanum titanate (LLTO) solid electrolyte is applied as a model system. Density functional theory calculations are used to describe bulk, surface, and interfacial thermochemistry of the Li/LLTO system, and interfacial reconstruction is probed using ab initio molecular dynamics. These simulations of the Li/LLTO interface demonstrate facile decomposition concomitant with reduction of Ti 4+ ions. Based on further insights from computational analysis of the surface band edge positions, La 2 O 3 is proposed as an interlayer coating and is shown to provide an energetic barrier for interfacial charge transfer and decomposition reactions from X-ray reflectivity measurements and theoretical calculations. The findings in this work suggest that design strategies based on surface and interfacial properties can be used to kinetically stabilize electrode/electrolyte interfaces in solid-state batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization Methodology of Polar Direct-Drive Illumination for the National Ignition Facility

Improved laser illumination uniformity drives shocks and implosions to create more extreme high energy density environments. Predominantly, the geometry of experiments that can be performed is dictated by the layout of beams at laser facilities, limiting inter-facility and multiscale investigations. This Letter presents the first automated, algorithmic approach for generating illumination configurations for high energy density experiments. The method is demonstrated in comparison to a polar direct drive solid target experiment at the National Ignition Facility. The new illumination configuration is simulated to create greater than ×3 higher peak pressure and almost ×2 higher density by maintaining better shock uniformity. Furthermore, the optimization process is performed with reduced computational expense and isotropic plasma profiles, while accounting for the impact of cross-beam energy transfer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ensemble Simulations on Leadership Computing Systems

Scientific productivity can be enhanced through workflow management tools, relieving large High Performance Computing (HPC) system users from the tedious tasks of scheduling and designing the complex computational execution of scientific applications. This paper presents a study on the usage of ensemble workflow tools to accelerate science using the Summit and Frontier supercomputing systems. The research aims to connect science domain simulations using Oak Ridge Leadership Computing Facility (OLCF) supercomputing platforms with ensemble workflow methods in order to accelerate HPC-enabled discovery and boost scientific impact. We present the coupling, porting and optimization of Radical-Cybertools on three applications: Chroma, NAMD and LAMMPS. The tools augment traditional HPC monolithic runs with a pilot scheduler. Lessons-learned are discussed for physics, biology and materials science applications. We discuss intrinsic limitations of coupling and porting ensemble workflow tools to applications that run on large HPC systems. The origins of technical challenges and their solutions developed during the implementation process are discussed. Data management strategies, OLCF’s policies for ensembles, and natively supported workflow tools are also summarized.

Georgiadou, Antigoni [ORNL] (ORCID:000000020977631↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗