Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Two-electron photoionization of ground-state lithium

We apply the convergent close-coupling (CCC) formalism to single-photon two-electron ionization of the lithium atom in its ground state. We treat this reaction as single-electron photon absorption followed by inelastic scattering of the photoelectron on a heliumlike Li{sup +} ion. The latter scattering process can be described accurately within the CCC formalism. We obtain integrated cross sections of single photoionization leading to the ground and various excited states of the Li{sup +} ion as well as double photoionization extending continuously from the threshold to the asymptotic limit of infinite photon energy. Comparison with available experimental and theoretical data validates the CCC model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dissociation dynamics of the water dication following one-photon double ionization. II. Experiment

We demonstrate here the use of cold target recoil ion momentum spectroscopy to perform state-selective measurements of the dissociative channels following single-photon double-ionization of ${\mathrm{H}}_{2}\mathrm{O}$. The two dominant dissociation channels observed lead to two-body (${\mathrm{OH}}^{+}+{\mathrm{H}}^{+}+2{e}^{{-}}$) and three-body ($2{\mathrm{H}}^{+}+\mathrm{O}+2{e}^{{-}}$) ionic fragmentation channels. In the two-body case we observe the presence of an autoionization process with a double-differential cross section that is similar to the single-photon double-ionization of helium well above threshold. In the three-body case, momentum and energy correlation maps in conjunction with new classical trajectory calculations in the companion theory paper by Z. L. Streeter et al. [Phys. Rev. A 98, 053429 (2018)] lead to the determination of the eight populated dication states and their associated fragmentation geometry. For the latter case, state-specific relative cross sections, median kinetic energy releases, and median angles between asymptotic proton momenta are presented. This benchmark-level experiment demonstrates that, in principle, state-selective fixed-frame triple-differential cross sections can be measured for some dication states of the water molecule.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-I-79: Effect of Number of Pinholes in Onboard Robotic Multi-Pinhole SPECT System

Purpose: To study the effect of number of pinholes for a novel Single Photon Emission Computed Tomography (SPECT) system for onboard molecular and functional imaging. Methods: Comparison studies were performed using simulation for the 49-pinhole SPECT system and a series of reductions in number of pinholes. Trajectories about the breast of a supine patient were considered. Minimum distances, radii of rotation (RORs), were determined by requirements to fully view the region of interest (ROI) and to avoid collision between the detector and the patient. Reductions in RORs translate into improvements in sensitivity. Starting from the 49-pinhole system, pinholes were removed pod by pod. The furthest two end pods in the Sup-Inf direction were removed first for their higher likelihood of alleviating the collision avoidance criteria. After iterating through different combinations of pinhole pods, and selecting three combinations, the corresponding RORs were used to analytically calculate sensitivities. Results: Based on the Methods procedure, 3 combination of pods removal were identified: 1) Superior peripheral pod 2) Inferior peripheral pod 3) both pods. RORs were reduced at only one multi-pinhole stop. Analytic calculation showed that sensitivities were reduced from 0.032 for the 49-pinhole system to 0.028 for 42-pinhole and to 0.023 for 39-pinhole system respectively. The sensitivity per pinhole detector was approximately the same for all three cases. Conclusion: For the trajectories considered, only minimal improvements in RORs were identified by removing pinhole pods. Consequently, sensitivities decreased in proportion to the number of pinholes. Studies of other anatomical sites are needed to determine if in some cases sensitivity per pinhole can be improved by removing some pinholes. PHS/NIH/NCI grant R21-CA156390-01A1.

60 APPLIED LIFE SCIENCES↗

Process Dependent Sivers Function and Implication for Single Spin Asymmetry in Inclusive Hadron Production

We study the single transverse spin asymmetries in the single inclusive particle production within the framework of the generalized parton model (GPM). By carefully analyzing the initial- and final-state interactions, we include the process-dependence of the Sivers functions into the GPM formalism. The modified GPM formalism has a close connection with the collinear twist-3 approach. Within the new formalism, we make predictions for inclusive {pi}{sup 0} and direct photon productions at RHIC energies. We find the predictions are opposite to those in the conventional GPM approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooperative spontaneous emission of N atoms: Many-body eigenstates, the effect of virtual Lamb shift processes, and analogy with radiation of N classical oscillators

We consider collective emission of a single photon from a cloud of N two-level atoms (one excited, N-1 ground state). For a dense cloud the problem is reduced to finding eigenfunctions and eigenvalues of an integral equation. We discuss an exact analytical solution of this many-atom problem for a spherically symmetric atomic cloud. Some eigenstates decay much faster then the single atom decay rate, while the others undergo very slow decay. We show that virtual processes yield a small effect on the evolution of rapidly decaying states. However, they change the long time dynamics from exponential decay into a power-law behavior which can be observed experimentally. For trapped states virtual processes are much more important yielding additional decay channels which results in a slow decay of the otherwise trapped states. We also show that quantum mechanical treatment of spontaneous emission of weakly excited atomic ensemble is analogous to emission of N classical harmonic oscillators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Introduction to Multiphoton Ionization and Study of Ionization Rate of Hydrogen Atom

From a semiclassical point of view, we discuss the problem of nonlinear interaction between electromagnetic radiation and atoms. The time-dependent Schroedinger equation for single electron systems is solved using perturbative technique to obtain transition probability. We also discuss higher order perturbation used in multiple processes where two or more quanta are emitted instead of a single photon. The approach is based on the assumption that the perturbation is small. From the transition probability ionization rate and absorption, the cross-section of hydrogen atoms is calculated. Variation in photon energy and field strength is analyzed. Variation of cross-section with photon energy is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other methods of dose calculation usually applied in the clinic.

60 APPLIED LIFE SCIENCES↗

Determination of the Goos-Hanchen shift in dielectric waveguides via photo emission electron microscopy in the visible spectrum

Photoemission Electron Microscopy (PEEM) is a versatile tool that relies on the photoelectric effect to produce high-resolution images. Pulse lasers allow for multi-photon PEEM where multiple photons are required excite a single electron. This non-linear process can directly image the near field region of electromagnetic fields in materials. We use this ability here to analyze wave propagation in a linear dielectric waveguide with wavelengths of 410nm and 780nm. The propagation constant of the waveguide can be extracted from the interference pattern created by the coupled and incident light and shows distinct polarization dependence. Furthermore, the electromagnetic field interaction at the boundaries can then be deduced which is essential to understand power flow in wave guiding structures. These results match well with simulations using finite element techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Multiple-Event, Single-Photon Counting Imaging Sensor

The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

Zheng, Xinyu↗

Efficient excitation of a two-level atom by a single photon in a propagating mode

State mapping between atoms and photons, and photon-photon interactions play an important role in scalable quantum information processing. We consider the interaction of a two-level atom with a quantized propagating pulse in free space and study the probability P{sub e}(t) of finding the atom in the excited state at any time t. This probability is expected to depend on (i) the quantum state of the pulse field and (ii) the overlap between the pulse and the dipole pattern of the atomic spontaneous emission. We show that the second effect is captured by a single parameter {Lambda}(set-membership sign)[0,8{pi}/3], obtained by weighting the dipole pattern with the numerical aperture. Then, P{sub e}(t) can be obtained by solving time-dependent Heisenberg-Langevin equations. We provide detailed solutions for both single-photon Fock state and coherent states and for various temporal shapes of the pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CMS results on exclusive and diffractive production

We present recent CMS measurements of diffractive and exclusive processes, using data collected at 7 TeV at the LHC. Measurements of soft single- and double-diffractive cross sections are presented, as well as measurements of photon-induced processes including studies of exclusive WW production via photon-photon exchange.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Selection of abstracts from the scientific sessions of The Society Of Nuclear Medicine and Molecular Imaging annual meeting Anaheim CA

This mini-review highlights cardiovascular studies that were presented during the Society of Nuclear Medicine and Molecular Imaging (SNMMI) 2019 annual meeting in Anaheim, California. The aim is to provide the readers insight to noteworthy studies related to the fields of nuclear cardiology presented during the conference. Although cardiovascular applications of positron emission tomography (PET) and single-photon emission computed tomography (SPECT) are not the primary focus of the SNMMI, several scientific teams working in this field presented their latest findings in Anaheim. While this review is directed to the benefit of those who were not able to attend the annual meeting, we believe that a general overview may also be useful for those who did attend as it is often difficult to get exposure to all the high-quality abstracts presented at this large conference.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measuring Intermolecular Excited State Geometry for Favorable Singlet Fission in Tetracene

Singlet fission (SF) is the process of converting an excited singlet to a pair of excited triplets. Harvesting two charges from a single photon has the potential to increase photovoltaic device efficiencies. Acenes, such as tetracene and pentacene, are model molecules for studying SF. Despite SF being an endoergic process for tetracene and exoergic for pentacene, both acenes exhibit near unity SF quantum efficiencies, raising questions about how tetracene can overcome the energy barrier. Here, we use recently developed instrumentation to measure inelastic neutron scattering (INS) while optically exciting the model molecules using two different excitation energies. The spectroscopic results reveal intermolecular structural relaxation due to the presence of a triplet excited state. Here, the structural dynamics of the combined excited state molecule and surrounding tetracene molecules are further studied using time-dependent density functional theory (TD-DFT), which shows that the singlet and triplet levels shift due to the excited state geometry, reducing the uphill energy barrier for SF to within kT.

36 MATERIALS SCIENCE↗

Photon-stimulated production of electron-positron pairs in an electric field

The rate of e{sup +}e{sup -} pair creation by external electric field in the presence of an incident photon beam is calculated for the photon energy far below the threshold, {omega}<<m, and the field strength small as compared to the critical one, eE<<m{sup 2}. We find the pair production rate using a recently developed method based on calculation of the process in a thermal bath with subsequent identification of the contribution of single-photon states. We demonstrate that a nontrivial dependence on the ratio of the small parameters, {omega}m/(eE), emerges in this approach from an essentially (semi)classical calculation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral control of nonclassical light pulses using an integrated thin-film lithium niobate modulator

Abstract Manipulating the frequency and bandwidth of nonclassical light is essential for implementing frequency-encoded/multiplexed quantum computation, communication, and networking protocols, and for bridging spectral mismatch among various quantum systems. However, quantum spectral control requires a strong nonlinearity mediated by light, microwave, or acoustics, which is challenging to realize with high efficiency, low noise, and on an integrated chip. Here, we demonstrate both frequency shifting and bandwidth compression of heralded single-photon pulses using an integrated thin-film lithium niobate (TFLN) phase modulator. We achieve record-high electro-optic frequency shearing of telecom single photons over terahertz range (±641 GHz or ±5.2 nm), enabling high visibility quantum interference between frequency-nondegenerate photon pairs. We further operate the modulator as a time lens and demonstrate over eighteen-fold (6.55 nm to 0.35 nm) bandwidth compression of single photons. Our results showcase the viability and promise of on-chip quantum spectral control for scalable photonic quantum information processing.

Optics↗

Leveraging lifetime information to perform real-time 3D single-particle tracking in noisy environments

A microscopy platform that leverages the arrival time of individual photons to enable 3D single-particle tracking of fast-moving (translational diffusion coefficient of ≃ 3.3 µm 2 /s) particles in high-background environments is reported here. It combines a hardware-based time-gating module, which enables the rate of photon processing to be as high as 100 MHz, with a two-photon excited 3D single-particle tracking confocal microscope to enable high sample penetration depth. Proof-of-principle experiments where single quantum dots are tracked in solutions containing dye-stained cellulose are shown, with tracking performance markedly improved using the hardware-based time-gating module. Furthermore, such a microscope design is anticipated to be of use to a variety of communities who wish to track single-particles in cellular environments, which commonly have high fluorescence and scattering background.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPECT imaging with resolution recovery

Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗