Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Real-time machine-learning-driven control system of a deformable mirror for achieving aberration-free X-ray wavefronts

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror’s response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

47 OTHER INSTRUMENTATION↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Thermally Activated Circularly Polarized Photoluminescence in a 2D Hybrid Perovskite with Giant Spin Splitting

Circularly polarized light generation and detection are critical for future spin-based technologies that inter-convert circularly polarized photons and electron spins. However, detailed mechanisms in such spin-photon interfaces are often either poorly understood or operate at cryogenic temperatures since typically small energies separating spin-split electronic bands facilitate thermally driven spin depolarization. Recently, several 2D hybrid perovskites with polar achiral cations were theoretically demonstrated to exhibit conduction and valence band spin-splitting energies greatly exceeding room-temperature thermal energy, suggesting their utility as spin-photon interfaces with practical operating temperatures. Here, a strong "spin memory" effect is reported in such a polar achiral layered perovskite that enables large room-temperature circularly polarized emission anisotropy following excitation with circularly polarized light. The polarization anisotropy depends strongly on temperature (thermally activated), excitation energy, and crystal orientation with respect to the excitation source. Temperature-dependent photoconductance measurements reveal similar thermally activated carrier generation. These observations suggest a mechanism whereby giant in-plane splitting of single-particle levels protects spin-polarization of photogenerated electrons and holes before recombination. Although polarized light emission is explored in greater detail in chiral perovskites, these results reveal that even without chirality, large spin memory in polar achiral perovskites can enable spin-photon interfaces that operate at elevated temperatures.

14 SOLAR ENERGY↗

Quantum Electrodynamics Coupled-Cluster at Scale: High-Performance Implementation for Complex Systems

Coupled-cluster theory (CC) is a highly accurate and versatile method for simulating complex interactions within quantum systems. The extension of CC theory to model mixed electron-photon processes with quantum electrodynamics (QED) has improved our capability to predict cavity-modified chemistry, a field where photons are used as cost-effective and eco-friendly alternatives to catalyze/inhibit chemical reactions. However, calculations with CC methods, even without incorporating QED effects, are often prohibitively expensive. Simulations of larger systems require scalable infrastructures that exist for traditional CC methods but not for QED-CC methods. As such, we present a GPU-enabled, high-performance, open-source implementation of the quantum electrodynamics coupled-cluster method with single and double excitations (QED-CCSD) within the ExaChem quantum chemistry software package. ExaChem relies on the Tensor Algebra for Many-body Methods (TAMM) infrastructure: a parallel heterogeneous tensor library designed to achieve scalable performance on modern heterogeneous supercomputing platforms. Furthermore, we discuss theoretical foundations, algorithmic details, and numerical benchmarks to showcase the larger systems that ExaChem can simulate and how the integration of photonic degrees-of-freedom alters their ground-state properties.

Basis sets↗

High-Quality Factor Microwave Resonators using Rhenium

Coplanar waveguide resonators are a perfect tool to evaluate the losses induced by defects and interfaces in superconducting devices. Even if niobium is the most used superconductor for resonators and qubits, its native oxide at the metal-air (MA) interface limits the device results. Tantalum has recently significantly improved qubit performances due to a thinner and less disordered oxide layer compared to Nb. To further improve the MA interface, we used rhenium, a superconducting material with 1.7 K critical temperature resistant to oxidation: it forms an oxide layer thinner than 1 nm. In this study, we will present a thorough investigation of rhenium CPW resonator measurements with internal quality factors at the single photon level exceeding 2 million. The devices have been fabricated on a sapphire substrate while the processing parameters have been varying and optimized. The measurements have been performed as a function of power and temperature to disentangle different sources of losses, such as two-level systems (TLS) and quasi-particles. A peculiar TLS temperature dependence has been measured and analyzed. In this work, we also vary the participation ratio of the devices to extract the losses introduced by the involved interfaces with higher fidelity and precision. We carried on a deep material characterization effort to link the results to the differences in the fabrication steps, and we will present material characterization measurements performed via AFM, ToF-SIMS, XPS, and TEM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theory of x-ray photon correlation spectroscopy for multiscale flows

Complex multiscale flows associated with instabilities and turbulence are commonly induced under high-energy density (HED) conditions, but accurate measurement of their transport properties has been challenging. X-ray photon correlation spectroscopy (XPCS) with coherent x-ray sources can, in principle, probe material dynamics to infer transport properties using time autocorrelation of density fluctuations. Here we develop a theoretical framework for utilizing XPCS to study material diffusivity in multiscale flows. We extend single-scale shear flow theories to broadband flows using a multiscale analysis that captures shear and diffusion dynamics. Our theory is validated with simulated XPCS for Brownian particles advected in multiscale flows. We demonstrate the versatility of the method over several orders of magnitude in timescale using sequential-pulse XPCS, single-pulse x-ray speckle visibility spectroscopy (XSVS), and double-pulse XSVS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attosecond delays in X-ray molecular ionization

The photoelectric effect is not truly instantaneous, but exhibits attosecond delays that can reveal complex molecular dynamics. Sub-femtosecond duration light pulses provide the requisite tools to resolve the dynamics of photoionization. Accordingly, the past decade has produced a large volume of work on photoionization delays following single photon absorption of an extreme ultraviolet (XUV) photon. However, the measurement of time-resolved core-level photoionization remained out of reach. The required x-ray photon energies needed for core-level photoionization were not available with attosecond tabletop sources. We have now measured the x-ray photoemission delay of core-level electrons, and here report unexpectedly large delays, ranging up to 700 attoseconds in NO near the oxygen K-shell threshold. These measurements exploit attosecond soft x-ray pulses from a free-electron laser (XFEL) to scan across the entire region near the K-shell threshold. Furthermore, we find the delay spectrum is richly modulated, suggesting several contributions including transient trapping of the photoelectron due to shape resonances, collisions with the Auger-Meitner electron that is emitted in the rapid non-radiative relaxation of the molecule, and multi-electron scattering effects. Finally, the results demonstrate how x-ray attosecond experiments, supported by comprehensive theoretical modelling, can unravel the complex correlated dynamics of core-level photoionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

Mid-infrared spectroscopy with a broadly tunable thin-film lithium niobate optical parametric oscillator

Mid-infrared spectroscopy, an important technique for sensing molecules, has encountered barriers from sources either limited in tuning range or excessively bulky for widespread use. We present a compact, efficient, and broadly tunable optical parametric oscillator surmounting these challenges. Leveraging dispersion-engineered thin-film lithium niobate-on-sapphire photonics and a singly resonant cavity allows broad, controlled tuning over an octave from 1.5–3.3 µm. The device generates >25mW of mid-infrared light at 3.2 µm with 15% conversion efficiency. The ability to precisely control the device’s mid-infrared emission enables spectroscopy of methane and ammonia, demonstrating our approach’s relevance for sensing. Our work signifies an important advance in nonlinear photonics miniaturization, bringing practical field applications of high-speed, broadband mid-infrared spectroscopy closer to reality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and Detection Limit of Spectroscopic-Grade Perovskite CsPbBr 3 Crystal for Hard X-Ray Detection

We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.

36 MATERIALS SCIENCE↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Multifunctional Superconducting Nanowire Quantum Sensors

Superconducting nanowire single-photon detectors (SNSPDs) offer high-quantum-efficiency and low-dark-count-rate single-photon detection. In a growing number of cases, large magnetic fields are being incorporated into quantum microscopes, nanophotonic devices, and sensors for nuclear and high-energy physics that rely on SNSPDs, but superconducting devices generally perform poorly in large magnetic fields. Here, we demonstrate robust performance of amorphous SNSPDs in magnetic fields of up to ±6 T with a negligible dark-count rate and unchanged quantum efficiency at typical bias currents. Critically, we also show that the SNSPD can be used as a magnetometer with a sensitivity of better than 100μT/√Hz and as a thermometer with a sensitivity of 20μK/√Hz at 1 K. Thus, a single-photon detector integrated into a quantum device can be used as a multifunctional quantum sensor capable of describing the temperature and magnetic field on chip simply by varying the bias current to change the operating modality from single-photon detection to thermometry or magnetometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ab initio evaluation of the electronic and optical properties of V B C B defect in wurtzite boron nitride as promising single-photon emitter

Single-photon emitters (SPEs) in the near-infrared (NIR) range with sharp and intense zero-phonon lines (ZPLs) of emission are critical for quantum communications. Certain local defects in wide-bandgap semiconductors create isolated occupied and unoccupied states within the bandgap of the host semiconductor and thus exhibit sharp ZPLs of emission. We designed and studied a defect in the wurtzite boron nitride as a potential SPE. It consists of a boron vacancy and a carbon atom substituting another boron atom (V B C B defect). The density of states is obtained within the GW method to identify favorable local defect states that may dominate optical transitions. The dielectric function and oscillator strength of the V B C B defect are obtained using the Bethe-Salpeter equation method to identify the optical excitations of the V B C B defect, from which we conclude that the defect could be a source of NIR emission with a narrow bright ZPL peak, thus an efficient SPE.

36 MATERIALS SCIENCE↗

Ultrabroad-band x-ray source using a picosecond, laser-driven plasma accelerator

An ultrabroad-band x-ray source, with photon energies from 10 keV to >1 MeV, based on a picosecond laser-driven plasma accelerator, is characterized and used to radiograph high-energy-density-science relevant targets. The measured yield of 10 12 photons/shot is reaching the necessary photon yields to radiograph, in a single shot, high areal density objects and matter under extreme conditions. By focusing a short laser pulse (120 J, 1 ps) into a gas jet, a < 100 mrad electron beam with energies up to 350 MeV and up to 70 nC of charge was produced by a combination of laser self-modulation instability and direct laser acceleration. A foil placed at the exit of the gas jet is used to convert part of the electron beam energy into x rays through inverse bremsstrahlung and/or inverse Compton scattering, generating a bright, broad-band, high-photon-energy beam. This beam is used to radiograph a gold half hohlraum with a high-density sphere inside with relevant characteristics for high-energy-density science and inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗