Conditional Tree Reduction in the ADAPT Framework

Probabilistic Risk Assessment (PRA) uses fault tree/event tree analysis to evaluate the environmental impacts of nuclear power plants due to internal or external initiating events. In a fault tree, basic failure events are assembled using primarily And/Or logic to determine the combinations of failures that lead to failure of the system as a whole. An event tree is forward-facing, and begins with a single initiating event. From there the analysis considers what event may occur next, and branches out among the possible configurations of occurrence and non-occurrence of that event. This branching continues until end states are reached. End states may include a safe and stable configuration of the plant, or any number of differing failure states. Both fault and event trees require basic event probabilities as inputs to provide insight on the likelihood of different outcomes. PRA has been applied to nuclear power plants as an analysis tool since the 1975 Reactor Safety Study. In a traditional PRA, the order of events is prescribed by the analyst and each event is typically a binary aleatory uncertainty: occurrence or non-occurrence. Discrete dynamic event tree (DDET) analysis eliminates this subjectivity in ordering of events by using the output of a dynamic system model (simulator) to inform the branching. Branching conditions are triggered by the existence of a relevant plant state in the code, and therefore only occur as physically appropriate. The DDET approach also allows consideration of both epistemic and aleatory uncertainties on a phenomenologically and stochastically consistent platform. A DDET may be orders of magnitude larger than a traditional event tree for the same initiating event, as more of the uncertainty space is likely to be explored and the tree does not require manual assembly. Because of the size, manual inspection of the entire DDET is often infeasible. This problem may be approached from the front by reducing the number of sampled branching values or by online pruning of the tree, thus reducing the total number of branches. Utilizing post-processing techniques to draw actionable insights via clustering has also been proposed. One post-processing tool to reduce the DDET according to user-defined rules has been recently implemented in the Analysis of Dynamic Accident Progression Trees (ADAPT) DDET driver code. The tool creates a 'slice' of the DDET comprised of the set of branches that meet a set of user-input rules, for immediate visualization or for further calculations conditional on the rules being met. This extension is expected to ease analysis of the results of large and complex DDETs, leading to greater applicability of DDETs in PRA. It should be emphasized that this tool is a visualization aide and does not impact the theoretical basis of the DDET approach. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantitative 3-D Elemental Mapping by LA-ICP-MS of a Basaltic Clast from the Hanford 300 Area, Washington, USA

Laser ablation with inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to measure elemental concentrations at the 100 {micro}m scale in a 3-dimensional manner in a basalt sample collected from the Hanford 300 Area in south-central Washington State. A modified calibration method was developed to quantify the LA-ICP-MS signal response using a constant-sum mass fraction of eight major elements; the method produced reasonable concentration measurements for both major and trace elements when compared to a standard basalt sample with known concentrations. 3-dimensional maps (stacked 2-D contour layers, each measuring 2100 {micro}m x 2100 {micro}m) show relatively uniform concentration with depth for intrinsic elements such as Si, Na, and Sr. However, U and Cu accumulation were observed near the rock surface, consistent with the site's release history of these pollutants. U and Cu show substantial heterogeneity in their concentration distributions in horizontal slices, while the intrinsic elements are essentially uniformly distributed. From measured U concentrations of this work and reported mass fractions, cobbles and gravels were estimated to contain from 0.6% to 7.5% of the contaminant U, implicating the coarse fraction as a long-term release source.

58 GEOSCIENCES↗

Towards scanning nanostructure X-ray microscopy

This article demonstrates spatial mapping of the local and nanoscale structure of thin film objects using spatially resolved pair distribution function (PDF) analysis of synchrotron X-ray diffraction data. This is exemplified in a lab-on-chip combinatorial array of sample spots containing catalytically interesting nanoparticles deposited from liquid precursors using an ink-jet liquid-handling system. A software implementation is presented of the whole protocol, including an approach for automated data acquisition and analysis using the atomic PDF method. The protocol software can handle semi-automated data reduction, normalization and modeling, with user-defined recipes generating a comprehensive collection of metadata and analysis results. By slicing the collection using included functions, it is possible to build images of different contrast features chosen by the user, giving insights into different aspects of the local structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗

SU-F-J-184: Proton Computed Tomography Using 1D Silicon Diode Array

Purpose: Proton radiography and proton computed tomography (PCT) can be used to measure proton stopping power directly. However, practical and cost effective proton imaging detectors are not widely available. In this study, the authors investigated the feasibility of proton imaging using a silicon diode array. Methods: A one-dimensional silicon-diode detector array (1DSDA) was aligned with the central axis (CAX) of the proton beam. Polymethyl methacrylate (PMMA) slabs were used to find the correspondence between the water equivalent thickness (WET) and 1DSDA channel number. 2D proton radiographs (PR) were obtained by translation and rotation of a phantom relative to CAX while the proton nozzle and 1DSDA were kept stationary. A PCT image of one slice of the phantom was reconstructed using filtered backprojection. Results: PR and PCT images of the PMMA cube were successfully acquired using the 1DSDA. The WET of the phantom was measured using PR data with an accuracy of 4.2% or better. Structures down to 1 mm in size could be resolved. Reconstruction of a PCT image showed very good agreement with simulation. Limitations in spatial resolution are attributed to limited spatial sampling, beam collimation, and proton scatter. Conclusion: The results demonstrate the feasibility of using silicon diode arrays for proton imaging. Such a device can potentially offer fast image acquisition, high spatial and energy resolution for PR and PCT.

60 APPLIED LIFE SCIENCES↗

Application of External-Cavity Quantum Cascade Infrared Lasers to Nanosecond Time-Resolved Infrared Spectroscopy of Condensed-Phase Samples Following Pulse Radiolysis

Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of DeltaOD <1 x 10(-3) has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890-2084 cm(-1), and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO(2) reduction catalyst, [Re(I)(bpy)(CO)(3)(CH(3)CN)](+), in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the nu(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Earth mover’s distance as a measure of CP violation

We introduce a new unbinned two sample test statistic sensitive to CP violation utilizing the optimal transport plan associated with the Wasserstein (earth mover’s) distance. The efficacy of the test statistic is shown via two examples of CP asymmetric distributions with varying sample sizes: the Dalitz distributions of B 0 → K + π – π 0 and of D 0 → π + π – π 0 decays. The windowed version of the Wasserstein distance test statistic is shown to have comparable sensitivity to CP violation as the commonly used energy test statistic, but also retains information about the localized distributions of CP asymmetry over the Dalitz plot. For large statistic datasets we introduce two modified Wasserstein distance based test statistics — the binned and the sliced Wasserstein distance statistics, which show comparable sensitivity to CP violation, but improved computing time and memory scalings. Finally, general extensions and applications of the introduced statistics are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

Fast Tomography: A Study Of Image Quality

We present tomographic slices of fast X-ray computed microtomography, focusing on one hand on the comparison of scans with identical scan time but varying experimental settings, on the other hand on comparing scans with total scan times that are two orders of magnitude apart. We show that streaks in the Fourier-space of the transformed images appear when the number of projections is reduced. These streaks exhibit spacing by the same angle as the one that is covered by the sample during the exposure time of one projection. Further a method for the estimation of information loss in fast scans is presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive center determination for effective suppression of ring artifacts in tomography images

Ring artifacts on tomogram slices hinder image interpretation. They are caused by minor variation in the response from individual elements in a two dimensional (2D) X-ray detector. Polar space decreases the suppression complexity by transforming the rings on the tomogram slice to linear stripes. However, it requires that the center of rings lie at the origin of polar transformation. If this is not the case, all methods employing polar space become ineffective. We developed a method based on Gaussian localization of the ring center in Hough parameter space to assign the origin for the polar transformation. Thus, obtained linear stripes can be effectively suppressed by already existing methods. This effectively suppresses ring artifacts in the data from a variety of experimental setups, sample types and also handles tomograms that are previously cropped. This approach functions automatically, avoids the need for assumptions and preserves fine details, all critical for synchrotron based nanometer resolution tomography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

MULTILEVEL MONTE CARLO (MLMC) SIMULATIONS: PERFORMANCE RESULTS FOR SPE10 (XY SLICES)

In this report we first describe a generic multilevel Monte Carlo method and then illustrate its superior performance over a traditional single-level Monte Carlo method for second order elliptic PDEs corresponding to two-dimensional layers in (x, y)-direction of the Tenth SPE Comparative Solution project (SPE 10) which gives high-contrast permeability coefficients. The SPE10 data set is used as a coarse level in the Monte Carlo method and the respective permeability coefficient k (provided in the SPE10 dataset) is used as a mean in the simulation. The actual coefficients are drawn based on a KL-expansion assuming that the log-mean is perturbed by a log-normal distributed samples.

97 MATHEMATICS AND COMPUTING↗

R and DE Robotic Sensor Intern Team: Sensor Suite Software and User Interface

The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. A postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans with one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 5) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. During alignment, local features are used to recognize points within the walls that are especially unique and noticeable (salient) based on their deviation from the expected surface of the wall. These are used as landmarks to register the clouds, which also informs precise localization of the base at each scan point. After registration, clouds are 'painted' with RGB data from the spherical cameras, as shown below. The painted clouds provide a 3D, colorized model of the environment which improves the realism of the experience for the user. Painting also labels high-resolution color imagery from the 3D cameras with depth values. Following sensor fusion, individual walls and cylindrical duct surfaces are segmented from the scene for individual analysis using a Random Sample Consensus algorithm. This algorithm allows segmentation of planar walls and cylindrical ducts. Once individual walls are identified, each point within the wall can be compared to its neighbors and the wall overall in order to detect local areas with damaged concrete. Automatic rebar detection is also performed using the contrast in Lidar return intensity between iron and concrete. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges in spatial metabolomics and proteomics for functional tissue unit and single-cell resolution

While transcriptomics is the most broadly applied technology for global spatial and single cell measurements in healthy and diseased tissues. Transcripts are often used as a proxy for protein and even metabolite measurements, but it has become commonly accepted that extrapolating this kind of information is a poor proxy and not a substitute for direct measurement. Within the last decade advanced developments of mass spectrometry-based assays have made these direct measurements not only possible, but routine. Where mass spectrometry has become an enabling technology, and various methods can now detect hundreds of metabolites and thousands of proteins from samples. Not only can this be performed within bulk measurements, but much effort has been directed into translating these measurements to single cells and tissues at cellular resolution. The information obtained from mass spectrometry is now able to trace metabolic events and decipher feedback loops across anatomical regions, connecting genetic and metabolic networks that define phenotypes. Herein, we will broadly overview developments in the field over the past decade, leading into several case studies which highlight the direct measurement of metabolites, proteins, and proteoforms from thinly sliced tissues. Much of this work is feasible due to multidisciplinary team science, and we offer brief perspective on paths forward and the challenges that persist with adoption and application of spatial omics.

59 BASIC BIOLOGICAL SCIENCES↗

Alpha-Quartz Plastic Strength Investigation Via Diffraction Experiments on Novaculite Using A D-Dia and Elastic Plastic Self- Consistent Interpretation [Thesis}

X-Ray Tomography. Porosity is commonly measured using mercury injection (MI) or water immersion porosimeter (WIP). Both MI and WIP utilize pressure to fill open voids with mercury or water respectively. A measure of the volume change of the sample is then used to estimate the percentage of open voids. However, for the purpose of rheological study it is important to get an accurate measure of open and closed voids. X-ray tomography has been selected as it offers a three-dimensional view into the sample that can quantify all pores limited only by the voxel size which is in the micron range for this study. Radiographs for tomography were collected at the Material Science and Technology Division at Los Alamos National Lab using the Carl Zeiss Xradio 520 instrument and Scout-and-Scan version 16.1 operating software. Two samples were imaged, the starting material and the deformed sample SiO2_65. 3001 radiographs were taken of the starting material with a 6 second exposure time using a 4x objective lens. The x-ray beam was set to 60 kilovoltage peak (kVp) and 5 watts. 1901 radiographs were taken of SiO2_65 with a 25 second exposure time using a 10x objective lens. The x-ray beam was set to 80 kVp and 7 watts. Radiograph files were analyzed by Brian Patterson using Avizo. Void and inclusion volumes were output by voxel sized (1.03 μm) slices, used to calculate a total percentage volume for the starting material.

36 MATERIALS SCIENCE↗

Using multimodal X-ray computed tomography to advance 3D petrography: A non-destructive investigation of olivine inside a carbonaceous chondrite

Rocks form in three dimensions through time and studying them provides information from inside dynamic systems we cannot otherwise observe. Yet how we typically access the interior of the rocks themselves to gain that information may limit our understanding and influence how we reconstruct the processes that formed them. Here, we demonstrate combined non-destructive 3D X-ray imaging techniques that produce quantitative densitometric and crystallographic maps of entire individual grains inside a rock. Olivine grains throughout a sample of the carbonaceous chondrite Northwest Africa (NWA) 11346 were each characterized by size, shape, composition, zoning intensity, and crystallographic orientation. The addition of 3D crystallographic mapping to calibrated 3D densitometric analysis—used to calculate chemical composition—demonstrates a fully non-destructive petrographic method and provides unique insight. For instance, in our case, using crystallographic data to delineate individual grains and then measuring the 3D size, shape, and composition of each distinguishes variably reset relict grains from those later crystallized after a melting event. Intersection in a 2D slice could not have led to this interpretation because the integration of three-dimensional size, rounding, composition, location, and crystallographic orientation measured from each grain forms the key patterns. Multimodal laboratory X-ray imaging has strong potential to advance 3D petrography.

36 MATERIALS SCIENCE↗

Machine learning for disruption warnings on Alcator C-Mod, DIII-D, and EAST

In this paper, we report on disruption prediction using a shallow machinelearning method known as Random Forests, trained on large databases containingonly plasma parameters that are available in real-time on Alcator C-Mod, DIII-D, and EAST. The database for each tokamak contains parameters sampled ~10 6 times throughout ~10 4 discharges (disruptive and non-disruptive) over the last 4years of operation. It is found that a number of parameters (e.g.P rad /P input ,l i ,n/n G ,B n=1 /B 0 ) exhibit changes in aggregate as a disruption is approached on one ormore of these tokamaks. However, for each machine, the most useful parameters,as well as the details of their precursor behaviors, are markedly different. When the prediction problem is framed using a binary classification scheme to discriminate between time slices "close to disruption" and "far from disruption," it is found that the prediction algorithms differ substantially in performance among the three machines ona time slice-by-time slice basis, but have similar disruption detection rates (~80-90%) on a shot-by-shot basis after appropriate optimisation. This could have important implications for disruption prediction and avoidance on ITER, for which developmentof a training database of disruptions may be infeasible. The algorithm's output is interpretable using a method that identifies the most strongly contributing inputsignals, which may have implications for avoiding disruptive scenarios. Lastly, to further support its real-time capability, successful applications in inter-shot and real-time environments on EAST and DIII-D are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Through-Thickness Microstructure Characterization in a Centrifugally Cast Austenitic Stainless Steel Nuclear Reactor Primary Loop Pipe Using Time-of-Flight Neutron Diffraction

The US code of Federal Regulations mandates regular inspection of centrifugally cast austenitic stainless steel pipe, commonly used in primary cooling loops in light-water nuclear power plants. These pipes typically have a wall thickness of ~8 cm. Unfortunately, inspection using conventional ultrasonic techniques is not reliable as the microstructure strongly attenuates ultrasonic waves. Work is ongoing to simulate the behavior of acoustic waves in this microstructure and ultimately develop an acoustic inspection method for reactor inspections. In order to account for elastic anisotropy in the material, the texture in the steel was measured as a function of radial distance though the pipe wall. Experiments were conducted on two 10 × 12.7 × 80 mm radial sections of a cast pipe using neutron diffraction scans of 2 mm slices using the HIPPO time-of-flight neutron diffractometer at the Los Alamos Neutron Science Center (LANSCE, Los Alamos, NM, USA). Strong textures dominated by a small number of austenite grains with their (100) direction aligned in the radial direction of the pipe were observed. ODF analysis indicated that up to 70% of the probed volume was occupied by just three single-grain orientations, consistent with grain sizes of almost 1 cm. Texture and phase fraction of both ferrite and austenite phases were measured along the length of the samples. These results will inform the development of a more robust diagnostic tool for regular inspection of this material.

42 ENGINEERING↗