Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral filter design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multi-slit spectrograph and H alpha Doppler system

Description of the design and operation of a multiple-entrance-slit spectrograph, built for time-lapse photography of the spectra of flares and other transient solar phenomena. This spectrograph employs narrow-band filters to limit the wavelength range of the spectrograph to a few angstroms centered at H-alpha or other spectral lines. A polarizing beamsplitter, prior to the slits, provides a prefiltered second solar image to a narrow band H-alpha Doppler filter for simultaneous photography in the wings of the H-alpha line. The spectrograph and the H-alpha Doppler system constitute a flexible instrument in which components may be substituted to achieve different passband widths, image scales, dispersions, and corresponding numbers and spacings of adjacent spectra at a selected wavelength.

Martin, S. F.↗

CIMATS - A correlation interferometer for the measurement of atmospheric trace species

A multigas correlation interferometer, based on the previously developed and tested COPE instrument, has been designed and fabricated and is presently undergoing laboratory testing. The CIMATS instrument has the capability to remotely measure densities of selected gaseous atmospheric species in the spectral range 2 to 2.5 and 4 to 10 microns. The sensor has been designed for both nadir viewing and earth limb viewing. As presently configured the sensor is capable of measuring ammonia, nitrous oxide, and carbon monoxide in the nonthermal infrared spectral region and carbon monoxide and sulfur dioxide in the thermal infrared. Other gaseous species can be measured by inclusion of additional narrow band filters.

Goldstein, H. W.↗

Performance analysis of a filtered wide field-of-view radiometer for earth radiation budget measurements

The proposed Earth Radiation Budget Satellite System (ERBSS) of the 1980's will include a wide field-of-view (WFOV) fixed axes earth radiator discriminator consisting of a shortwave channel and a total (unfiltered) channel. The broadband spectral isolation required for the shortwave channel is achieved by use of a hemispherical fused silica (Suprasil W) dome filter placed in front of a wire wound thermopile radiation detector. A description is presented of the thermal response of the single-fused silica dome filter in the ERBSS WFOV shortwave channel conceptual design and the impact of that response on the channel measurement. Results from design definition and performance analysis studies are included. Problems associated with achieving the desired levels of confidence in a high accuracy filtered, WFOV radiometer are discussed. Design approaches, ground calibration, and data reduction techniques which minimize measurement uncertainties are explained.

Cooper, J. E.↗

X ray, extreme and far ultraviolet optical thin films for space applications

Far and extreme ultraviolet optical thin film filters find many uses in space astronomy, space astrophysics, and space aeronomy. Spacebased spectrographs are used for studying emission and absorption features of the earth, planets, sun, stars, and the interstellar medium. Most of these spectrographs use transmission or reflection filters. This requirement has prompted a search for selective filtering coatings with high throughput in the FUV and EUV spectral region. Important progress toward the development of thin film filters with improved efficiency and stability has been made in recent years. The goal for this field is the minimization of absorption to get high throughput and enhancement of wavelength selection. The Optical Aeronomy Laboratory (OAL) at the University of Alabama in Huntsville has recently developed the technology to determine optical constants of bulk and film materials for wavelengths extending from x-rays (0.1 nm) to the FUV (200 nm), and several materials have been identified that were used for designs of various optical devices which previously have been restricted to space application in the visible and near infrared. A new design concept called the Pi-multilayer was introduced and applied to the design of optical coatings for wavelengths extending from x-rays to the FUV. Section 3 of this report explains the Pi-multilayer approach and demonstrates its application for the design and fabrication of the FUV coatings. Two layer Pi-stacks have been utilized for the design of reflection filters in the EUV wavelength range from 70 - 100 nm. In order to eliminate losses due to the low reflection of the imaging optics and increase throughput and out-of-band rejection of the EUV instrumentation we introduced a self-filtering camera concept. In the FUV region, MgF2 and LiF crystals are known to be birefringent. Transmission polarizers and quarterwave retarders made of MgF2 or LiF crystals are commercially available but the performances are poor. New techniques for the design of the EUV and FUV polarizers and quarterwave retarders are described in Section 5. X- and gamma-ray detectors rely on a measurement of the electron which is effected when a ray interacts with matter. The design of an x- and gamma-ray telescope to operate in a particular region of the spectrum is, therefore, largely dictated by the mechanism through which the rays interact. Energy selection and the focusing of the incident high energy rays can be achieved with spectrally selective high reflective multilayers. The design and spectral performance of narrowband reflective x-ray Pi-multilayers are presented in section 6.

Zukic, Muamer↗

Intelligent Optical Systems Using Adaptive Optics

Until recently, the phrase adaptive optics generally conjured images of large deformable mirrors being integrated into telescopes to compensate for atmospheric turbulence. However, the development of smaller, cheaper devices has sparked interest for other aerospace and commercial applications. Variable focal length lenses, liquid crystal spatial light modulators, tunable filters, phase compensators, polarization compensation, and deformable mirrors are becoming increasingly useful for other imaging applications including guidance navigation and control (GNC), coronagraphs, foveated imaging, situational awareness, autonomous rendezvous and docking, non-mechanical zoom, phase diversity, and enhanced multi-spectral imaging. The active components presented here allow flexibility in the optical design, increasing performance. In addition, the intelligent optical systems presented offer advantages in size and weight and radiation tolerance.

Clark, Natalie↗

Transient characteristics of simple systems to modulated random noise.

Discussed are the mean-square response exceedance characteristics of a single-tuned system to amplitude modulated noise. The results bear on the accuracy of spectral estimates of nonstationary data, and subsequently, relate directly to the design, analysis, and testing of structural systems in environments as gusts, earthquakes, and ignition transients. For noise correlated as an exponentially damped cosine, the nonstationary response may exceed its stationary value by a factor in excess of two. A time-varying shaping filter explanation is offered for this behavior. For white noise, such exceedances do not occur.

Barnoski, R. L.↗

The Pioneer Venus Orbiter plasma wave investigation

The Pioneer Venus plasma wave instrument has a self-contained balanced electric dipole (effective length = 0.75 m) and a 4-channel spectrum analyzer (30% bandwidth filters with center frequencies at 100 Hz, 730 Hz, and 30 kHz). The channels are continuously active and the highest Orbiter telemetry rate (2048 bits/sec) yields 4 spectral scans/sec. The total mass of 0.55 kg includes the electronics, the antenna, and the antenna deployment mechanism. This report contains a brief description of the instrument design and a discussion of the in-flight performance.

Scarf, F. L.↗

Development of an Optical Model for the MEDLI2 Radiometer

We present an optical model of the MEDLI2 radiometer, which was flown onboard the Mars 2020 vehicle during atmospheric entry on February 18, 2021. The proposed model takes into account the radiometer geometry and optical phenomena such as reflection, refraction, and absorption to estimate the signal loss inherent in the design of the radiometer. The model serves as a filter, which can be used to convert predicted total radiative heat fluxes on the radiometer window into predicted measured heat fluxes, enabling more accurate comparisons of the radiometer flight data with predicted radiometer measurements. Optical properties of the radiometer’s sapphire window are inferred from spectral transmissivity measurements. A modified Lorentz Oscillator Model is used to represent the dielectric function of the window and is fit to the transmission data. The resulting optical model of the radiometer is validated against experimental data used to measure the dependence of the radiometer output voltage on the incident angle of the light impinging on it. Comparison of predicted radiometer measurements with the MEDLI2 flight data show good agreement between the predicted and measured peak heat fluxes, though offset at different times. A linear increase in the signal loss due to radiometer optics alone is also demonstrated, suggesting that the changing shock angle over the course of the trajectory impacts the signal loss.

MEDLI2↗

Optimal use of electrophysiological indicators of muscular effort and fatigue

Electromyograms (EMG) from working muscles convey information on effort and fatigue. Their application, e.g., to assess the demands of vehicle control tasks, is complicated by the cooperative action of sets of muscles, by both intrinsic and imposed filtering, and by numerous other sources of variation. Fourier analyses of these noise like signals offer one approach to interpretation; downward spectral shifts accompany fatigue. Techniques are being sought (in both time and frequency domains) for further condensing the wideband EMG signals, while retaining essential information, into a concise 'state vector' usable in comparing control system designs.

Updike, O. L.↗

Band-pass filtering of one year of daily mean pressures on Mars

The sol-mean atmospheric pressures measured at the two Viking landers exhibit fluctuations ranging in period from seasonal to a few days. The time series are highly nonstationary, which severely limits standard methods such as power-spectrum analysis. Advantage is taken of the rather precise annual periodicity of these data to design sharp numerical filters and use them to split the series at each lander into six time series, each containing oscillations associated with a discrete frequency band. This analysis reveals 2- to 4-sol waves during the cold seasons at both landers, and 8-sol waves during the spring at Lander 2, confirming previous results from spectral analysis. As previously predicted, high-frequency waves appear suppressed during the second dust storm. Certain low-frequency signals, probably associated with the global dust storms, are detected and demonstrated to be significant for the first time.

Niver, D. S.↗

Extreme ultraviolet filters for 58.4 and 83.4 nm

We report the design of an EUV filter for He I at 58.4 nm and the design and fabrication of an EUV filter for O II at 83.4 nm. Both filters are designed as combinations of three narrow-band reflection filters. The net transmittance through both EUV filters is close to 10 percent with bandwidths less than 10 nm, and blocking better than 0.005 percent for out-of-band wavelengths. A theoretical calculation of the 83.4 nm filter predicts higher values for the peak transmittance than the measured spectral performance of the fabricated filter. Since aluminum is one of the film materials used for the fabrication of EUV filters, the aluminum film oxidation can be modeled in order to explain the discrepancy between the theory and experiment. Since the filters operate at angles of incidence up to 50 deg, the optical components of a system can serve as both the filtering and imaging elements.

Zukic, Muamer↗

Pioneer-Venus solar flux radiometer

The paper presents the design and performance characteristics of the Solar Flux Radiometer flown on the Large Probe of the Pioneer-Venus Multiprobe spacecraft. Radiance measurements of the Venusian atmosphere in spectral channels between 400 and 1800 nm as a function of altitude were made, along with elevation and azimuthal measurements of the radiation field performed with five optical channels. Filtered Si and Ge photovoltaic detector output currents were processed with logarithmic transimpedance converters prior to being multiplexed and digitized. Atmospheric sampling in elevation and azimuth was done according to a Gaussian integration scheme; the received data were used to determine the deposition of solar energy in the Venus atmosphere along with upward and downward fluxes and radiances with an altitude resolution of several hundred meters between 67 km and the surface.

Palmer, J. M.↗

Comparison of existing digital image analysis systems for the analysis of Thematic Mapper data

Most existing image analysis systems were designed with the Landsat Multi-Spectral Scanner in mind, leaving open the question of whether or not these systems could adequately process Thematic Mapper data. In this report, both hardware and software systems have been evaluated for compatibility with TM data. Lack of spectral analysis capability was not found to be a problem, though techniques for spatial filtering and texture varied. Computer processing speed and data storage of currently existing mini-computer based systems may be less than adequate. Upgrading to more powerful hardware may be required for many TM applications.

Likens, W. C.↗

The development of a power spectral density processor for C and L band airborne radar scatterometer sensor systems

A real-time signal processor was developed for the NASA/JSC L-and C-band airborne radar scatterometer sensor systems. The purpose of the effort was to reduce ground data processing costs. Conversion of two quadrature channels of data (like and cross polarized) was made to obtain Power Spectral Density (PSD) values. A chirp-z transform (CZT) approach was used to filter the Doppler return signal and improved high frequency and angular resolution was realized. The processors have been tested with record signals and excellent results were obtained. CZT filtering can be readily applied to scatterometers operating at other wavelengths by altering the sample frequency. The design of the hardware and software and the results of the performance tests are described in detail.

Harrison, D. A., III↗

Compact FUV camera concept for Space Weather applications

Far ultraviolet (FUV) images of Earth from space have proven invaluable in revealing contextual phenomena associated with space weather in the high latitude auroral regions and, more recently with TIMED and IMAGE in the mid and equatorial regions. Images of this nature can be used to investigate compelling questions associated with the interaction of the ionosphere/mesosphere-magnetosphere-solar wind. Three such questions are: 1. What are the critical time and spatial scales that determine the coupling between the magnetosphere and ionosphere? 2. What are the sources and characteristics of ionospheric variability? 3. How does the configuration of the magnetosphere change as a function of internal boundary conditions established by the mesosphere/ionosphere and the external driving conditions of the solar wind? Observations that lead to quantitative analyses are required to significantly advance the state of knowledge with regard to the affects of space weather and the interaction between and within these regions of Geospace. Current available image data sets are sufficient for qualitative analysis and morphological investigations, and while quantitative analyses are possible, they are difficult and limited to few events at best. In order to qualitatively access the time, spatial, and causal phenomena on global scales, simultaneous images of various FUV emissions with a combination of better spatial, temporal and spectral resolution and sensitivity than currently available is required. We present an instrument concept that is being developed to improve the spatial, temporal and spectral resolution and sensitivity needed to perform the quantitative analysis that enable significant advancement in our understanding of the impact of space weather on Geospace. The approach is to use the self-filtering concept that combines the imaging and filtering functions and thus reduces the size of the 4-mirror off-axis optical system. The optical and filter design will de described and results of preliminary breadboard tests will be provided.

Spann, James↗

Infrared detector performance in the Shuttle Infrared Telescope Facility /SIRTF/

The limitations imposed on infrared detectors for SIRTF are quite different from those imposed on ground-based, balloon-borne, or aircraft-borne systems. The paper examines the limitations and provides performance predictions corresponding to SIRTF conditions. Detector parameters typical of an infrared camera are used. The detector size is taken to be of the order of the diffraction-limited spot, frequency response is taken to correspond to a fraction of a second or less time constant, and spectral definition is provided by multilayer dielectric filters, inductive or capacitive grids, intrinsic absorption, or a combination of these. A nominal 10-micron bandwidth is assumed. The discussion covers atmospheric absorption and emission, zodiacal dust radiance, Shuttle contaminants, telescope self-emission, charged particle radiation, clear environment detector performance, and trapped radiation effects. It is concluded that the SIRTF design and operating conditions will allow current and near-term state-of-the-art detectors to reach their performance limits with SIRTF at a temperature of 10-12 K.

Mccarthy, S. G.↗

The solar ultraviolet spectral irradiance monitor (SUSIM) experiment on board the Upper Atmosphere Research Satellite (UARS)

The state of solar ultraviolet irradiance measurements in 1978, when NASA requested proposals for a new generation of solar ultraviolet monitors to be flown on the Upper Atmosphere Research Satellite (UARS), is described. To overcome the radiometric uncertainties that plagued the measurements at this time, the solar ultraviolet spectral irradiance monitor (SUSIM) instrument design included in-flight calibration light sources and multichannel photometers. Both are aimed at achieving a maximum precision of the SUSIM measurements over a long period of time, e.g., one solar cycle. The design of the SUSIM-UARS instrument is compared with the original design specifications for the UARS instruments. Details including optical train, filters, detectors, and contamination precautions are described. Also discussed are the SUSIM-UARS preflight calibration and characterization, as well as the results of the inflight performance of the instrument during the first 3 months of operation. Finally, flight operations, observation strategy, and data reduction schemes are outlined.

Brueckner, G. E.↗

Diagnostics Adapted for Heat-Treating Furnace Environment

Diagnostics developed for the in situ monitoring of rocket combustion environments were adapted for use in heat-treating furnaces. Simultaneous, in situ monitoring of the carbon monoxide, carbon dioxide, methane, water, and hydrogen concentrations in the endothermic gas of a heat-treating furnace were demonstrated under a Space Act Agreement between the NASA Lewis Research Center, the Heat Treating Network, and Akron Steel Treating Company. This endothermic gas, or "endogas," is produced in a catalytic process, where natural gas is "cracked" in the presence of air. Variations in the composition of the natural gas supplied lead to variations in the composition of the endothermic gas. These variations could lead to an unacceptable quality of steel products that are hardened through the carborization process that uses this gas. Conventional methods of monitoring the endogas include measuring the dew point of the gas and the oxygen concentration. From these data, the carbon monoxide content of the gas can be calculated. This carbon monoxide concentration creates the carbon potential needed for carburization. Several weak links are present in this approach. The oxygen monitor deteriorates over time, and the measurement might be inaccurate by 50 percent. Also, the chemistry equations, which are based on several assumptions, such as secondary species concentrations, provide only an approximate estimate of the carbon monoxide concentration. To address these weaknesses, we investigated a new method based on ordinary Raman spectroscopy, in which the carbon monoxide concentration is measured directly and in situ. This method measures the laser light scattered from the molecules. Each species interacts with the light and scatters the light at a different frequency. Spectral monitoring of the scattered light intensity at each molecular frequency of interest provides the species concentrations. One advantage over the conventional method is that several species can be monitored simultaneously. A second advantage is that the measurement is direct; there is no need to make assumptions, to filter the gas, or to calibrate the instrument. An instrument was designed consisting of a laser and a detection system within an enclosure, connected to an optical probe by fibers. For determining carbon monoxide concentration, the probe is mounted on the endothermic gas line, close to the generator. Optical fibers with a length of 150 ft have been used to transmit laser light from the instrument to the probe. There, the light is focused into the gas, and the scattered light is collected and transmitted back to the instrument where it is analyzed with a photomultiplier and lock-in amplifier. Laboratory tests have shown that with the current system the concentration of carbon monoxide, water, nitrogen, oxygen, and hydrogen in the air can be monitored with an accuracy of 1 percent. The concentration of carbon dioxide in the air can be monitored with an accuracy of 0.5 percent, and the concentration of methane with an accuracy of 0.2 percent. This instrument was taken to the Akron Steel Treating Plant, where field tests are in progress to verify the system capabilities. Planned developments are improving the accuracy, monitoring multiple locations, and reducing instrument size and cost.

Source record↗