Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Intensified charge coupled devices for use as a spaceborne spectrographic image-plane detector system

An instrument that has been developed for studies of atmospheric emissions from the Space Shuttle comprises an array of imaging spectrometers to observe features over the 300-12,000-A wavelength range. Each spectrometer has a 2-D image-plane detector system on which spectral information is dispersed in one direction and spatial information is resolved in the other. The detectors consist of CCD arrays which are coupled to proximity focused image intensifiers. The intensifier in each case is selected for the wavelength range covered by the particular spectrometer. The result is a compact low-power spectrographic detector system. In the course of building the five flight detector systems, there was occasion to evaluate a larger number of the charge coupled devices and the proximity focused image intensifiers. Various characteristics, advantages, and shortcomings of these devices and the overall intensified CCD system are reported.

Torr, M. R.↗

Polarizer mechanism for the space telescope faint object spectrograph

The polarizer mechanism for the Space Telescope Faint Object Spectrograph is described. This device will allow spectropolarimetric measurements of faint astronomical objects. The mechanism employs a unique arrangement to meet functional requirements in a compact package and with only one actuator. Detailed tolerance analysis and a variety of tests indicate that the polarizer is capable of accurate and reliable performance.

Thulson, M. D.↗

Progress report on the high resolution spectrograph for the Space Telescope

The instrument design is complete and many components and subsystems have been manufactured and tested. Solar-blind, multichannel, pulse counting detectors for two ultraviolet spectral bands have been developed and satisfactory flight units have been chosen. A large, lightweight graphite-epoxy optical bench, utilizing fingerplate joints with no metallic parts in order to minimize thermal expansion, has been built. Tests of the engineering model torque-motor-driven grating carrousel indicate that this critical system exceeds tight specifications for accurate and repeatable angular positioning. A complement of large, high-frequency gratings and an echelle is being completed in several laboratories. Software resident in a computer on the spacecraft will control the spectrograph with the capability to alter procedures in response to real-time evaluation of the data.

Brandt, J. C.↗

Performance of the spectropolarimeter for the Space Telescope faint object spectrograph

The design and preliminary test results for the spectropolarimeter for the Faint Object Spectrograph (FOS) for the Space Telescope are presented. The mechanical design and optical specifications of the spectropolarimeter are described noting that a Wollaston prism with an internal wedge angle of 20 deg is fixed behind each of two rotatable waveplate retarders of different retardations. Either waveplate/prism combination can be positioned at either of the two FOS entrance ports. Magnesium fluoride is chosen as the birefringent crystal for the polarizing elements to allow linear and circular polarization measurements down to Lyman-alpha at 1216 A. Mechanical stability and repeatability were determined by operational testing to give polarization-position angles of + or - 0.5 deg, corresponding to degree-of-polarization measurements of + or - 0.1 percent. Faint-object accuracy, dependent on photoelectron statistics and hence on observation time, is calculated to be one percent in each 100-A-wide spectral band for a 20-min observation of an AO star with V = 15th magnitude.

Allen, R. G.↗

Faint Object Spectrograph (FOS) calibration

The Faint Object Spectrograph (FOS) designed for use with The Space Telescope (ST), is currently preparing for instrument assembly, integration, alignment, and calibration. Nearly all optical and detector elements have been completed and calibrated, and selection of flight detectors and all but a few optical elements has been made. Calibration results for the flight detectors and optics are presented, and plans for forthcoming system calibration are briefly described.

Harms, R. J.↗

An ultraviolet spectrograph using an echelle grating with cross-disperser for the measurement of stratospheric constituents

The present investigation is concerned with the development of a high resolution echelle-cross disperser grating spectrograph for application in groundbased, balloon, and Shuttle studies of the middle atmosphere and thermosphere. All the design features discussed pertain specifically to the balloon instrument. Attention is given to examples of scientific objectives for the middle atmosphere, aspects of instrument description, imaging requirements, the spectral multiplexing capability, broad wavelength coverage, sensitivity, dynamic range, scattered light, the optical configuration of the instrument, the detector system, the data system, and the results of laboratory tests and theoretical evaluations.

Torr, D. G.↗

A Far Ultraviolet Imaging Spectrograph for Shuttle

The development of the Far Ultraviolet Imaging Spectrograph (FUVIS) Shuttle sortie missions, is described. Objectives of the experiment are to obtain spatially-resolved far-ultraviolet spectra of extraterrestrial sources, including emission-line and reflection nebulae, diffuse background radiation, extragalactic objects, and comets. The use of fast focal ratio (f/1) Schmidt optics and an opaque CsI photocathode which affords high quantum efficiency in the far-UV provides the maximum possible diffuse source sensitivity. Measured emission line intensities of 5 Rayleighs (or continua of intensity 1 R/A) in 300 sec exposures are expected. The development includes a dedicated pointing platform and a low light level television camera for payload specialist use in target acquisition and guiding.

Carruthers, G. R.↗

Calibration and operation of the Faint Object Spectrograph

The design and basic performance characteristics of the Faint Object Spectrograph (FOS), one of five instruments built for use on the Space Telescope observatory, is summarized briefly. The results of the recently completed instrument-level calibration are presented with special emphasis on issues affecting plans for FOS astronomical observations. Examples include such fundamental characteristics as: limiting magnitudes (system sensitivity and noise figures), spectral coverage and resolution, scattered light properties, and instrumental polarization and modulation efficiencies. Also gated toward intended users, a rather detailed description of FOS operating modes is given. The discussion begins with the difficulties anticipated during target acquisition and their hoped-for resolution. Both the 'normal' spectroscopic operating modes of the FOS and its 'exotic' features (e.g. spectropolarimetric, time-tagged, and time-resolved modes) are presented. The paper concludes with an overview of the activities to assure proper alignment and operation of the FOS within the entire Space Telescope system (orbital and ground-based).

Harms, R.↗

Echelle/Grism Spectrograph

More even spectral dispersion over detector area makes all wavelengths more distinguishable. Proposed echelle spectrograph includes grating/prism combination, called "grism," to make spectral dispersion over detector more even than usually in such instruments. Instrument performance improved, with little additional manufacturing effort. Furthermore, since grism placed within collimated light and its faces are optically flat, introduces no aberrations into optical system.

Dantzler, A. A.↗

Interstellar Medium Absorption Profile Spectrograph (IMAPS)

The design and fabrication of an objective-grating echelle spectrograph to fly on sounding rockets and record spectra of stars from approximately 920 to 1120A with a resolving power lambda/delta lambda = 200,000 is discussed. The scientific purpose of the program is to observe, with ten times better velocity resolution than before, the plentiful absorption lines in this spectral region produced by atoms, ions and molecules in the interstellar medium. In addition, an important technical goal is to develop and flight-quality a new ultraviolet, photon-counting image sensor which has a windowless, opaque photocathode and a CCD bombarded directly by the accelerated photoelectrons. Except for some initial difficulties with the performance of CCDs, the development of the payload instrument is relatively straightforward and our overall design goals are satisfied. The first flight occurred in late 1984, but no data were obtained because of an inrush of air degraded the instrument's vacuum and caused the detector's high voltage to arc. A second flight in early 1985 was a complete success and obtained a spectrum of pi Sco. Data from this mission are currently being reduced; quick-look versions of the spectra indicate that excellent results will be obtained. Currently, the payload is being reconfigured to fly on a Spartan mission in 1988.

Jenkins, E. B.↗

Design and performance of the high-resolution spectrograph sensor subsystem

The general design and performance of a digicon sensor system developed for the high-resolution spectrograph (HRS) to be flown on the shuttle-launched space telescope are discussed. The digicon sensor system consists of an encapsulated digicon tube, deflection/tweaking coil, permanent magnet assembly, wiring interface assembly, preamplifiers, and high-voltage power supply. The performance attributes and capabilities of the digicon sensor system exceed those of any existing space qualified system; the HRS digicon lifetime has been demonstrated to be far in excess of space telescope orbital requirements.

Eck, H. J.↗

Determination of stellar radial velocity precision attainable with a coude spectrograph

An instrument to measure highly accurate radial velocities of stars, in order to detect low-mass stellar and planetary companions was proposed. The University of Hawaii's Institute for Astronomy has assembled nearly all the resources needed to realize the highest radial velocity precision attainable with conventional coude spectrographs.

Heacox, W. D.↗

A faint-object grism spectrograph with multiple slits and CCD detector

A high-efficiency spectrograph for research on faint astronomical objects has been successfully built and is in regular use on the Multiple-Mirror Telescope (MMT). It is equipped with a motorized multi-slit mechanism to allow simultaneous observations of several objects. The combination of high throughput, multiple object capability, and low-noise CCD detector has allowed routine work to be extended to objects of V magnitude 23 and fainter.

Geary, John C.↗

Spectrograph Measures Contamination Of Optical Elements

Scanning-monochromator spectrograph designed to measure contamination on surfaces of optical elements as function of time. Repeatedly exposes samples to environment, then measures their transmittances or reflectances over range of wavelengths. Intended for use at vacuum-ultraviolet wavelengths to evaluate effects of outgassing, heating, and cooling on optical instruments. Principle of operation also applicable to spectral monitoring of time-dependent contamination at other wavelengths and in laboratory, industrial, or other settings.

Flint, Bruce K.↗

Fabrication of MgF2 and LiF windows for the Hubble Space Telescope Imaging Spectrograph

Two prototype test windows (MgF2 and LiF) to be used on the 75-mm UV MAMA detector tubes for the Hubble Space Telescope Imaging Spectrograph are described. The spatial and optical constraints of this instrument dictate that the thickness of the window materials be no greater than 2-3 mm to achieve a minimum 50-percent transmission at hydrogen Lyman alpha (121.6 nm), and that the window must be domed to minimize optical aberrations and provide structural strength. The detector window has an input diameter of about 100 mm with a radius-of-curvature of 70 mm. The manufacturing processes involved in the fabrication of these windows is discussed, as well as test programs (optical and structural) to be performed at Goddard Space Flight Center.

Gormley, Daphne↗

Wide range magnetic electron spectrograph

An electron spectrogrpah is described that covers electron energies from 400 eV to 200 keV with an energy resolution of 10 percent. This overlaps the range of electrostatic deflection devices at low energy and solid state detectors at high energy. The spectrograph uses magnetic deflection of the electrons to achieve energy separation and images the full range of energies on a single plane. The magnetic circuit uses the fringing field of two axially located magnets to attain the large energy range. Six separate electron beams can be dispersed in the field, each entering the circuit from a different angle. This is a particular advantage when measuring plasma electron three-dimensional velocity distributions. The angular response of the instrument is particularly favorable and the stray magnetic field is sufficiently low to meet spacecraft requirements.

Coplan, M. A.↗

Scattered light in the echelle modes of the Goddard high-resolution spectrograph aboard the Hubble Space Telescope. I - Analysis of prelaunch calibration data

A study of scattered light in the echelle mode of the Goddard high-resolution spectrograph (GHRS), one of the first-generation science instruments aboard the Hubble Space Telescope, is reported. The data analyzed are from the GHRS ground-based test program and include observations with the 500 channel Digicon detectors through the small science aperture of UV emission-line sources, continuum sources, and continuum sources viewed through molecular absorption cells. The two largest contributors to scattered light are the echelle and cross-disperser, the effects of which have been quantified. A computer simulation using the derived scattering functions demonstrates that the combined effects of these sources of scattered light adequately explain the observed level of interorder light when viewing UV continuum sources. Observing strategies and data reduction algorithms for measuring and removing the effects of the scattered light are discussed.

Cardelli, Jason A.↗

Far-ultraviolet spectroscopy of the quasar UM 675 with the faint object spectrograph on the Hubble Space Telescope

To investigate the far-UV spectral properties of a QSO and to look for evidence of He I 584 A emission and absorption the Faint Object Spectrograph aboard the HST was used to observed UM 675. Light is detected down to 520 A in the object in the rest frame and limits are set to He I emission, the He I Gunn-Peterson effect at z = 2.148, and Ly-alpha absorption at z roughly 0.5.

Beaver, E. A.↗