Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Aries x ray objective grating spectrograph

This investigation was initiated in June of 1983. An Aries payload involving a single Wolter 1 telescope was developed and flown under a previous contract and the objective of this work was to add two additional mirrors, nested inside of the then existing mirror and add 12 objective reflection gratings to convert the telescope into a spectrograph. A summary of major milestones in the investigation are given. Results of efforts under this contract prior to 1987 are presented in the form of four reprints of published papers attached to this report. Results of the gamma-ray research are also included in the form of an attached reprint. A summary of other work under the contract since 1987 is given.

Catura, R. C.↗

Hubble Space Telescope: Faint object spectrograph instrument handbook. Version 1.1

The Faint Object Spectrograph (FOS) has undergone substantial rework since the 1985 FOS Instrument Handbook was published, and we are now more knowledgeable regarding the spacecraft and instrument operations requirements and constraints. The formal system for observation specification has also evolved considerably, as the GTO programs were defined in detail. This supplement to the FOS Instrument Handbook addresses the important aspects of these changes, to facilitate proper selection and specification of FOS observing programs. Since the Handbook was published, the FOS red detector has been replaced twice, first with the best available spare in 1985 (which proved to have a poor, and steadily degrading red response), and later with a newly developed Digicon, which exhibits a high, stable efficiency and a dark-count rate less than half that of its predecessors. Also, the FOS optical train was realigned in 1987-88 to eliminate considerable beam-vignetting losses, and the collimators were both removed and recoated for greater reflectivity. Following the optics and detector rework, the FOS was carefully recalibrated (although only ambient measurements were possible, so the far-UV characteristics could not be re-evaluated directly). The resulting efficiency curves, including improved estimates of the telescope throughput, are shown. A number of changes in the observing-mode specifications and addition of several optional parameters resulted as the Proposal Instructions were honed during the last year. Target-brightness limitations, which have only recently been formulated carefully, are described. Although these restrictions are very conservative, it is imperative that the detector safety be guarded closely, especially during the initial stages of flight operations. Restrictions on the use of the internal calibration lamps and aperture-illumination sources (TA LEDs), also resulting from detector safety considerations, are outlined. Finally, many changes have been made to the instructions for target acquisition specification.

Ford, Holland C.↗

Hubble Space Telescope: Goddard high resolution spectrograph instrument handbook. Version 2.1

The Goddard High Resolution Spectrograph (GHRS) is an ultraviolet spectrometer which has been designed to exploit the imaging and pointing capabilities of the Hubble Space Telescope. It will obtain observations of astronomical sources with greater spectral, spatial and temporal resolution than has been possible with previous space-based instruments. Data from the GHRS will be applicable to many types of scientific investigations, including studies of the interstellar medium, stellar winds, chromospheres and coronae, the byproducts and endproducts of stellar evolution, planetary atmospheres, comets, and many kinds of extragalactic sources. This handbook is intended to introduce the GHRS to potential users. The main purpose is to provide enough information to explore the feasibility of possible research projects and to plan, propose and execute a set of observations. An overview of the instrument performance, which should allow one to evaluate the suitability of the GHRS to specific projects, and a somewhat more detailed description of the GHRS hardware are given. How observing programs will be carried out, the various operating modes of the instrument, and the specific information about the performance of the instrument needed to plan an observation are discussed.

Duncan, Douglas K.↗

The simulated space proton environment for radiation effects on Space Telescope Imaging Spectrograph (STIS)

The space telescope imaging spectrograph (STIS) is a second generation instrument planned for the Hubble Space Telescope (HST) which is currently in orbit. Candidate glasses and other transmitting materials are being considered for order sorters, in-flight calibration filters, detector windows, and calibration lamps. The glasses for in-flight calibration filters showed significant drop in UV transmission, but can probably still be used on STIS. The addressed topics include the Hubble radiation environment, simulation of orbital exposure at Harvard Cyclotron Laboratory, measurement of spectral transmission, and comments on individual samples.

Becher, Jacob↗

The Mees CCD imaging spectrograph

The Mees CCD (MCCD0 instrument is an imaging spectroscopy device which uses the 25-cm coronagraph telescope and the 3.0-m Coude spectrograph at Mees Solar Observatory on Haleakala, Maui. The instrument works with resolving power up to about 200,000 with significant throughput from 3934 A (Ca II K) to about 10,000 A. A fast guiding active mirror stabilizes the image during observations. A rapidly writing magnetic tape storage system allows observations to be recorded at 256 kbytes/s. Currently, the MCCD is used for imaging spectroscopy of solar flares at 6563 A (H-alpha), and velocity measurements of umbral oscillations; future plans include emission line studies of active region coronae, and photospheric studies of solar oscillations.

Penn, Matthew J.↗

Development of a miniaturized, light-weight magnetic sector for a field-portable mass spectrograph

A miniaturized, lightweight magnetic sector for a focal plane mass spectrograph (Mattauch-Herzog design) has been designed and fabricated by using a new high-energy-product magnet material (Nd-B-Fe alloy) and a high permeability magnet yoke material (V-Co-Fe alloy). The magnetic sector weighs less than 10 kg, has a focal plane of 5.1 cm in length, and covers a nominal mass range of 40-240 amu. Such a magnetic sector, in conjunction with an array detector and a short microbore capillary column, is well suited for the development of a field-portable gas chromatograph-mass spectrometer instrument of high performance.

Sinha, M. P.↗

A Cassegrain echelle spectrograph

The 'LPL echelle' is a CCD spectrograph with a resolving power of 160,000 and enough sensitivity to detect the brighter airglow emissions in a few minutes. It uses an R3.2 grating in a novel out-of-plane mounting that permits any wavelength to be placed on the blaze. A single order is selected by a medium-band interference filter. Lower dispersions and broader wavelength coverage are obtained by replacing the echelle by a 600 line/mm grating or a Littrow prism.

Hunten, D. M.↗

Resolution and noise properties of the Goddard High-Resolution Spectrograph

The Goddard High-Resolution Spectrograph (GHRS) observation characteristics and data analysis procedures, including deconvolution, are discussed. Particular attention is given to the detection of weak absorption lines in low-signal-to-noise observations. It is found that observations with the GHRS large aperture provide greater sensitivity for the detection of weak, isolated spectral features than does the small aperture for equal observing times. The noise characteristics are well represented by a Poisson distribution at low signal-to-noise characteristics. It is proposed that GHRS observations should be routinely structured with the use of comb-addition, quarter-substepping, FP-SPLITS, and multiple repeats to enable the proper discrimination against noise events capable of mimicking spectral features.

Gilliland, Ronald L.↗

Observations of the solar corona with a high resolution EUV imaging spectrograph

An extreme ultraviolet imaging spectrograph was used to obtain coronal observations with high spectral and spatial resolution. The imaging properties of the instrument enable measurements of spectral line shapes and positions in discrete spatial elements of a region, so that the dynamic characteristics of the coronal plasma, as well as the distribution of emission measure with temperature and well known density diagnostics, can be studied for specific features. The instrumentation is described and several results of a sounding rocket flight on 5 May 1989, when the corona over NOAA Region 5464 including emission over the umbra of the region's largest sunspot and the pre-impulsive phase emission of a small flare was recorded, are summarized.

Neupert, Werner M.↗

Faint object spectrograph observations of the large-redshift gravitational lens candidate 1208+1011

HST spectroscopic observations of 3.8-redshift gravitational lens candidate 1208+1011 are reported. Low-dispersion Faint Object Spectrograph data covering the wavelength range 3700-7800 A are obtained for each of the two components and for a comparison field; the fainter component and the black field are both separated by 0.47 arcsec from the brighter image. The spectra of both components possess strong Ly-alpha/N V and O VI/Ly-beta emission lines at a redshift of 3.8 as well as a number of similar absorption features. Both components have a ratio of the equivalent widths of the O VI complex to the Ly-alpha complex much larger than the typical value seen in large-redshift quasars. The small differences in the measured profiles of the Ly-alpha and O VI/Ly-beta emission lines of the images could be caused by absorption along different paths to a single lensed object, by unequal imaging of extended emissions, by systematic measuring errors, or by intrinsic differences in two nearly identical neighboring quasars.

Bahcall, John N.↗

Hubble Space Telescope Faint Object Spectrograph and ground-based observations of the broad absorption line quasar 0226-1024

Faint Object Spectrograph data from the Hubble Space Telescope of the broad absorption line quasar 0226-1024 have revealed the presence of 8-10 absorbing ions between 680 and 1000 A (restframe): C III, N III, N IV, O III, O IV, O VI, S V, S VI, possibly Ne VIII, and possibly O V* arising from a metastable excited state. We also present ground-based optical observations of the broad line troughs for the following ions: H I, C IV, N V, Si IV, and possibly Fe III, S IV, P V, and C III* (also arising from a metastable excited state). The results of this fit are used to estimate the absorbing ionic column densities. There is evidence that the broad absorption line clouds are optically thick and either do not completely cover the continuum source or narrow unresolved lines are present.

Korista, Kirk T.↗

Goddard high-resolution spectrograph observations of the local interstellar medium and the deuterium/hydrogen ratio along the line of sight toward Capella

HST Goddard High-Resolution Spectrograph observations of the 1216, 2600, and 2800 A spectral regions are analyzed for the spectroscopic binary system Capella, obtained at orbital phase 0.26 with 3.27-3.57 km/s resolution and high SNR. The column densities of H I, D I, Mg II, and Fe II for the local interstellar medium along this 12.5 pc line of sight, together with estimates of the temperature and turbulent velocity are inferred. It is inferred that the atomic deuterium/hydrogen ratio by number is 1.65(+0.07, -0.18) x 10 exp -5 for this line of sight. Galactic evolution calculations indicate that the primordial D/H ratio probably lies in the range of (1.5-3) x (D/H)LISM. If H0 = 80 km/s Mpc, as recent evidence suggests, then the baryonic density in units of the Einstein-de Sitter closure density is 0.023-0.031. Thus the universe is argued to expand forever, unless nonbaryonic matter greatly exceeds the amount of baryonic matter.

Linsky, Jeffrey L.↗

Observations of 3C 273 with the Goddard High Resolution Spectrograph on the Hubble Space Telescope

The observations of the quasar 3C 273 taken with the Goddard High Resolution Spectrograph in 1991 February are presented here. We have included both the reduced raw data, and smoothed and deconvolved spectra. Also, a list of observed absorption lines is presented. The data comprise 11 spectra, including one low resolution and 10 medium resolution observations. The wavelength region covered ranged from about 1150 to 2820 A, but was not all inclusive. The procedures used to obtain and reduce the data, including corrections for fixed pattern noise, compensation for the effects of spherical aberration in the HST primary mirror, and objective detection of weak absorption lines, are described. We also have included a short discussion on the detection of galactic Ni II and Virgo cluster metal lines.

Brandt, J. C.↗

A comparison of theoretical CIV emission line strengths with active region observations obtained with the solar EUV rocket telescope and spectrograph (SERTS)

Theoretical line ratios involving 2s 2S - 3p 2P, 2p 2p - 3s 2S, and 2p 2S - 3d 2D transitions in C IV between 312 and 420 A are presented. A comparison of these with solar active region observational data obtained during a rocket flight by the Solar EUV Rocket Telescope and Spectrograph (SERTS) reveals good agreement between theory and experiment, with discrepancies that average only 22 percent. This provides experimental support for the accuracy of the atomic data adopted in the line ratio calculations, and also resolves discrepancies found previously when the theoretical results were compared with solar data from the S082A instrument on board Skylab. The potential usefulness of the C IV line ratios as electron temperature diagnostics for the solar transition region is briefly discussed.

Keenan, F. P.↗

Goddard high-resolution spectrograph observations of narrow discrete stellar wind absorption features in the ultraviolet spectrum of the O7.5 III star Xi Persei

We report the observation of transient narrow absorption components (NACs) in the stellar wind of the O giant Xi Per. Two sets of GHRS observations of the Si IV ultraviolet resonance doublet have been obtained. These features are extremely weak, with column densities of approximately 10 exp 12/sq cm and optical depths of order 0.1. The features are narrow, less than 30 km/s, and seem to occur in groups. If the NACs are due to the 1393 A component, they represent previously undetected low-velocity discrete absorption components at V(rad) below -600 km/s. If they are high-velocity features on the 1402 A doublet component, they may represent the decay phase of the discrete absorption components at the terminal velocity. In either case, they are a new aspect of the NAC phenomenon that could not have been detected with previous ultraviolet spectrographs.

Shore, Steven N.↗

A high resolution ultraviolet Shuttle glow spectrograph

The High Resolution Shuttle Glow Spectrograph-B (HRSGS-B) is a small payload being developed by the Naval Research Laboratory. It is intended for study of shuttle surface glow in the 180-400 nm near- and middle-ultraviolet wavelength range, with a spectral resolution of 0.2 nm. It will search for, among other possible features, the band systems of excited NO which result from surface-catalyzed combination of N and O. It may also detect O2 Hertzberg bands and N2 Vegard-Kaplan bands resulting from surface recombination. This wavelength range also includes possible N2+ and OH emissions. The HRSGS-B will be housed in a Get Away Special canister, mounted in the shuttle orbiter payload bay, and will observe the glow on the tail of the orbiter.

Carruthers, George R.↗

SPECFOCUS: An IRAF task for focusing spectrographs

An IRAF task for measuring the point-spread function (PSF) along the dispersion and wavelength shifts across the dispersion in two dimensional arc spectra is described. In typical use, a set of spectra are obtained with various spectrograph focusing and alignment adjustments and the PSF information and shift information is derived and presented in tabular and graphical forms. Within each image the spectra may be divided into a number of samples along the dispersion and across the dispersion to investigate variations at different points in the detector at fixed focus settings. With many spectra and many samples interpreting the measurements is challenging. The task provides an interactive graphical interface to display the measurements in a number of interesting ways. The underlying algorithm for measuring the PSF and shifts in the auto/cross-correlation of spectral are samples.

Valdes, F.↗