Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectroscopy and imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Velocity Dispersions of Massive Quiescent Galaxies from Weak Lensing and Spectroscopy

We use MMT spectroscopy and deep Subaru Hyper Suprime-Cam (HSC) imaging to compare the spectroscopic central stellar velocity dispersion of quiescent galaxies with the effective dispersion of the dark matter halo derived from the stacked lensing signal. The spectroscopic survey (the Smithsonian Hectospec Lensing Survey) provides a sample of 4585 quiescent galaxy lenses with measured line-of-sight central stellar velocity dispersion ($\sigma_{\rm SHELS}$) that is more than 85\% complete for $R < 20.6$, $D_{n}4000> 1.5$ and $M_{\star} > 10^{9.5}{\rm M}_{\odot}$.The median redshift of the sample of lenses is 0.32. We measure the stacked lensing signal from the HSC deep imaging. The central stellar velocity dispersion is directly proportional to the velocity dispersion derived from the lensing $\sigma_{\rm Lens}$, $\sigma_{\rm Lens} = (1.05\pm0.15)\sigma_{\rm SHELS}+(-21.17\pm35.19)$. The independent spectroscopic and weak lensing velocity dispersions probe different scales, $\sim3$kpc and $\gtrsim$ 100 kpc, respectively, and strongly indicate that the observable central stellar velocity dispersion for quiescent galaxies is a good proxy for the velocity dispersion of the dark matter halo. We thus demonstrate the power of combining high-quality imaging and spectroscopy to shed light on the connection between galaxies and their dark matter halos.

79 ASTRONOMY AND ASTROPHYSICS↗

Height-resolved emission spectroscopy and high-speed imaging of the TiAl6V4 vapor plume under laser powder bed fusion conditions

Optical emission spectroscopy is increasingly used as an in situ monitoring technique during laser powder bed fusion (LPBF) because plume emission holds elemental information not found in other in situ sensing techniques. This work explores the shape, stability, and temperature of the emission plume above the melt pool of Ti6Al4 V undergoing laser scans under LPBF-like processing conditions, using high-speed video and height-resolved spectroscopy to study the details of plume dynamics. Optical emission spectroscopy is conducted in the 480 nm to 525 nm region, where Ti emission is strong, with 0.3 mm vertical resolution above the baseplate. The Boltzmann plot method is used to determine temperature at each probed elevation, which indicates that the hottest location of the plume is occasionally elevated 0.3 mm to 0.6 mm above the scanning surface. The results show that the plume shape, stability, temperature, and spectra are highly dependent on the processing conditions. We highlight some of the complexities of optical emission spectroscopy and discuss potential challenges for implementing optical emission spectroscopy across an entire build.

36 MATERIALS SCIENCE↗

Simulating Reflected Light Exoplanet Spectra of the Promising Direct Imaging Target, υ Andromedae d, with a New, Fast Sampling Method Using the Planetary Spectrum Generator

Simulations of exoplanet albedo profiles are key to planning and interpreting future direct imaging observations. In this paper we demonstrate the use of the Planetary Spectrum Generator (PSG) to produce simulations of reflected light exoplanet spectra. We use PSG to examine multiple issues relevant to all models of directly imaged exoplanet spectra and to produce sample spectra of the bright, nearby exoplanet υ Andromedae d (υ And d), a potential direct imaging target for next-generation facilities. We introduce a new, fast, and accurate subsampling technique that enables calculations of disk-integrated spectra one order of magnitude faster than Chebyshev–Gauss sampling for moderate- to high-resolution sampling. Using this method and a first-principles-derived atmosphere for υ And d, we simulate phase-dependent spectra for a variety of different potential atmospheric configurations. The simulated spectra for υ And d include versions with different haze and cloud properties. Based on our combined analysis of this planet’s orbital parameters, phase- and illumination-appropriate model spectra, and realistic instrument noise parameters, we find that υ And d is a potentially favorable direct imaging and spectroscopy target for the Coronagraph Instrument (CGI) on the Nancy Grace Roman Space Telescope. When a noise model corresponding to the Roman CGI SPC spectroscopy mode is included, PSG predicts the time required to reach a signal-to-noise ratio of 10 of the simulated spectra in both the central wavelength bin of the Roman CGI SPC spectroscopy mode (R = 50 spectrum) and of the Band 1 HLC imaging mode is approximately 400 and less than 40 hr, respectively. We also discuss potential pathways to extricating information about the planet and its atmosphere with future observations and find that Roman observations may be able to bound the interior temperature of the planet.

74 ATOMIC AND MOLECULAR PHYSICS↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

Visible core spectroscopy at Wendelstein 7-X

This paper presents an overview of recent hardware extensions and data analysis developments to the Wendelstein 7-X visible core spectroscopy systems. These include upgrades to prepare the in-vessel components for long-pulse operation, nine additional spectrometers, a new line of sight array for passive spectroscopy, and a coherence imaging charge exchange spectroscopy diagnostic. Progress in data analysis includes ion temperatures and densities from multiple impurity species, a statistical comparison with x-ray crystal spectrometer measurements, neutral density measurements from thermal passive Balmer-alpha emission, and a Bayesian analysis of active hydrogen emission, which is able to infer electron density and main ion temperature profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Three-dimensional (3D) velocity map imaging: from technique to application

The velocity map imaging (VMI) technique was first introduced by Eppink and Parker in 1997, as an improvement to the original ion imaging method by Houston and Chandler in 1987. The method has gained huge popularity over the past two decades and has become a standard tool for measuring high-resolution translational energy and angular distributions of ions and electrons. VMI has evolved gradually from 2D momentum measurements to 3D measurements with various implementations and configurations. The most recent advancement has brought unprecedented 3D performance to the technique in terms of resolutions (both spatial and temporal), multi-hit capability as well as acquisition speed while maintaining many attractive attributes afforded by conventional VMI such as being simple, cost-effective, visually appealing and versatile. Here, in this tutorial, we will discuss many technical aspects of the recent advancement and its application in probing correlated chemical dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Probing the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals using high-resolution photoelectron imaging of cryogenically cooled anions

High-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled pyrrolide and imidazolide anions are used to probe the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals. The high-resolution data allow the ground state vibronic structures of the two radicals to be completely resolved, yielding accurate electron affinities of 2.1433 ± 0.0008 eV and 2.6046 ± 0.0006 eV for pyrrolyl and imidazolyl radicals, respectively. Fundamental frequencies for eight vibrational modes of pyrrolyl and ten vibrational modes of imidazolyl are measured, including several nonsymmetric Franck–Condon-forbidden modes. Two electronic excited states are also observed for the two radicals, displaying diffuse spectral features in both systems. The observations of nonsymmetric vibrational modes in the ground states and the diffuse excited state features provide strong evidence for vibronic couplings between the ground state and the two close-by excited states. The 2-pyrrolide isomer is also observed as a minor species from the electrospray ionization source and the electron affinity of 2-pyrrolyl is measured to be 1.6690 ± 0.0030 eV along with five vibrational frequencies. Even though the HOMOs of both pyrrolide and imidazolide anions are p orbitals, photodetachment spectroscopy reveals completely different threshold behaviors for the two anions: a d-wave-dominated spectrum for pyrrolide and an s-wave-dominated spectrum for imidazolide. Furthermore, the current study provides a wealth of electronic and spectroscopic information, which is ideal to compare with more accurate vibronic coupling calculations for these two important radicals, as well as interesting information about the photodetachment dynamics of the two anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Spectral Anomaly Detection in EELS Spectral Images via 3D Convolutional Variational Autoencoders

Abstract A 3D Convolutional Variational Autoencoder (3D‐CVAE) is introduced for automated anomaly detection in electron energy‐loss spectroscopy spectrum imaging (EELS‐SI) data. This approach leverages the full 3D structure of EELS‐SI data to detect subtle spectral anomalies while preserving both spatial and spectral correlations across the datacube. By employing cross‐entropy loss and training on bulk spectra, the model learns to reconstruct bulk features characteristic of the defect‐free material. In exploring methods for anomaly detection, both the 3D‐CVAE approach and principal component analysis (PCA) are evaluated, testing their performance using FeL‐edge ΔEpeak shifts designed to simulate material defects. These results show that 3D‐CVAE achieves superior anomaly detection and maintains consistent performance across various shift magnitudes. The method demonstrates clear bimodal separation between bulk and anomalous spectra, enabling reliable classification. Further analysis verifies that lower‐dimensional representations are robust to anomalies in the data. While performance advantages over PCA diminish with decreasing anomaly concentration, our method maintains high reconstruction quality even in challenging, noise‐dominated spectral regions. This approach provides a robust framework for unsupervised automated detection of spectral anomalies in EELS‐SI data, particularly valuable for analyzing complex material systems.

Chemistry↗

Near field excited state imaging via stimulated electron energy gain spectroscopy of localized surface plasmon resonances in plasmonic nanorod antennas

Continuous wave (cw) photon stimulated electron energy loss and gain spectroscopy (sEELS and sEEGS) is used to image the near field of optically stimulated localized surface plasmon resonance (LSPR) modes in nanorod antennas. An optical delivery system equipped with a nanomanipulator and a fiber-coupled laser diode is used to simultaneously irradiate plasmonic nanostructures in a (scanning) transmission electron microscope. The nanorod length is varied such that the m = 1, 2, and 3 LSPR modes are resonant with the laser energy and the optically stimulated near field spectra and images of these modes are measured. Various nanorod orientations are also investigated to explore retardation effects. Optical and electron beam simulations are used to rationalize the observed patterns. As expected, the odd modes are optically bright and result in observed sEEG responses. The m = 2 dark mode does not produce a sEEG response, however, when tilted such that retardation effects are operative, the sEEG signal emerges. Thus, we demonstrate that cw sEEGS is an effective tool in imaging the near field of the full set of nanorod plasmon modes of either parity.

36 MATERIALS SCIENCE↗

Sum frequency generation (SFG) microscopy analysis of cellulose microfibrils in Physcomitrium patens gametophore leaf

Physcomitrium patens is a good model system to study the structure and function relationships of cellulose synthase (CESA) proteins since the life cycle of moss is short and genetic modification is relatively easy. Here, we report a microscopic sum frequency generation (SFG) vibrational spectroscopy analysis of P. patens leaves in a never-dried and fully hydrated state. Using imaging-SFG spectroscopy, cellulose microfibril (CMF) organization in the midrib, laminar, and marginal regions of the gametophore leaf were analyzed separately. The azimuth angle dependence of SFG signals showed that CMFs in the thick stereid cell walls in the midrib are highly aligned along the microfibril angle of ~ 30° with respect to the midrib axis. CMFs in the marginal cell walls also are preferentially tilted toward the longitudinal axis of leaf with the characteristic features of secondary cell walls. On the other hand, CMFs in the lamina cell walls have no preferential orientation and their SFG intensity is low, which is consistent with the primary cell wall property. Finally, the thick walls and highly aligned CMFs in the midrib and marginal cells of P. patens leaves are consistent with their support function.

59 BASIC BIOLOGICAL SCIENCES↗

Nature of contaminants introduced in silicon wafers during molecular beam epitaxy chamber annealing

Epitaxial monolithic III–V/Si tandem solar cells are one of the most promising technologies to be adopted by the industry after the efficiency of the current market dominating single junction silicon solar cell saturates at its fundamental limit. One of the key limitations of this technology is the degradation of silicon wafers during in situ annealing in the molecular beam epitaxy chamber. Determining the nature of contaminants in this process is key to improve the efficiency of epitaxial tandem solar cells. However, to date, the nature of contaminants from molecular beam epitaxy chambers remains unknown. In this work, we use photoluminescence imaging, lifetime spectroscopy, and deep level transient spectroscopy to measure the electronic properties of extrinsic impurities incorporated during annealing in the molecular beam epitaxy chamber. Photoluminescence images reveal that at least two impurities diffuse into silicon wafers during molecular beam epitaxy annealing. One is highly localized, while the other one is distributed uniformly across the whole wafer. Phosphorus diffusion is found to confine the localized impurity within the diffused layer but is ineffective at preventing the indiffusion of other impurities. Lifetime spectroscopy shows that metastable impurities with characteristic similar to Cr and CrB in our molecular beam epitaxy annealed silicon wafers. No evidence of Fe or FeB was observed. The emission rates and concentrations of the electrically active defects were measured with deep-level transient spectroscopy: The emission rates of detected defects do not match that of known Cr-related defects.

36 MATERIALS SCIENCE↗