Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration-based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Topical Analyses Related to Co-located Industrial Facilities at Nuclear Power Plants

This report investigates topics of interest with regard to Nuclear Power Plants (NPPs) utilizing flexible plant operations and generation (FPOG). Previous reports have identified the risk associated with co-located hydrogen generation facilities. This report evaluates special topics with regard to co-location of both hydrogen and syngas production facilities. A literature review was conducted to evaluate overpressure mitigation techniques that may be available to the NPP to reduce the consequence of an overpressure event. Also, the overpressure consequence of a catastrophic hydrogen storage tank failure event was analyzed. A comparison of the similarities and differences between the methodology utilized in HyRAM+ and Regulatory Guide 1.91 (R.G. 1.91) was performed for overpressure analysis. Also, the trinitrotoluene (TNT) equivalency methodology was utilized to evaluate an overpressure event at a Syngas production facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

Evaluating the economic impacts of using enzymatic membranes to optimize bicarbonate production and delivery to open raceway ponds

Gas sparging is the most commonly used method for delivering CO2 to algal cultures in Open Raceway Ponds (ORPs). While this method is well-tested and effective, these systems experience large amounts of outgassing to the surrounding atmosphere and often achieve carbon utilization efficiencies (CUE) lower than 30%. With such large losses, system are overdesigned to provide CO2 gas in extreme excess, resulting in increased capital and operational expenses. This research is focused on the development, testing, and implementation of a hydrogel membrane seeded with the enzyme carbonic anhydrase and designed to convert gaseous CO2 into aqueous bicarbonate and deliver this inorganic carbon (iC) directly to the algae pond. Despite increased capital expenses for the module, bicarbonate storage tank, and added pumps and infrastructure, preliminary results suggest that the membrane module has the potential to reduce the minimum biomass selling price by 35% by significantly reducing the operational expenditure for CO2.

09 BIOMASS FUELS↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of High Level Waste Sludge Processing Behavior

The U.S. Department of Energy’s (DOE) Hanford Site has 177 underground storage tanks that contain wastes from past nuclear fuel reprocessing and waste-management operations. Over 20% of this waste is in the form of an insoluble sludge that will require slurry modification before its transfer to the Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred to the WTP. One challenging requirement relates to the undissolved solids (UDS) composition in a waste feed because the waste contains solid particles that settle, and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty is the ability to transfer and mix wastes with large variations in UDS concentrations and resulting settling rates. To address this uncertainty, a number of small scale mixing and settling tests have been conducted to determine the mobilization performance of variable chemistry simulants. Comparison of the size and density of the particulate for each simulant to that of southeast area Hanford sludge was made using metrics for particle mobilization, suspension, settling, and pipeline transfer where dependance on particle size and density may be different, including: 1. Settling velocity, 2. Critical shear stress for erosion, 3. Just-suspended impeller speed, and 4. Pipeline critical transport velocity. Existing high-level waste sludge data has shown the effect that increasing Al concentration has on resulting settled solids. This differential settling of particles in the sludge has the possibility of resulting in solids segregation during feed preparation and uneven particle distribution during pipeline transportation or mixer jet pump operations. Understanding the predictive capabilities of HLW solids settling and transport as well as potential remedies for addressing disparate sludge behaviors can help provide technical guidance during HLW flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finding of adverse effect and proposed mitigation for the removal of three primary resources and twenty-four accessory resources within the mercury historic district, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes the removal of three primary resources and 24 accessory resources in Mercury on the Nevada National Security Site (NNSS) in Nye County, Nevada. The majority of the resources are concrete pads that have previously been recorded as either primary resources or accessory resources thereof within the Mercury Historic District (MHD). They represent the former locations of environmental support program buildings including a greenhouse (MHD Resource C312), warehouses (Resource C293), offices (Resource C314), dormitories (Resource C298), and two of unknown purpose (Resource C292). The other resources include a buried storage tank and sidewalks.

54 ENVIRONMENTAL SCIENCES↗

FY25 Organic Evaporation Testing in Support of Hanford Sample-and-Send

The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the approximately 56 million gallons of radioactive mixed waste stored in 156 underground storage tanks. The baseline method for immobilization of Low-Activity Waste (LAW) is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. Additionally, efforts are being undertaken to accelerate the disposition of Pre-Treated Waste (PTW) in Hanford’s West Area. An alternative cementitious waste form is being investigated as an alternative immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration-based standard in the final waste form. Hence, if the quantity of organics in PTW and LAW is high enough, treatment may be needed to destroy or remove said organics to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates evaporation as a potential avenue for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Affinity of LDR Organics to Cementitious Materials and Activated Carbon

The Hanford site stores approximately 56 million gallons of radioactive and hazardous waste in underground storage tanks. The current low-activity waste (LAW) vitrification facility does not have the capacity to immobilize all of the LAW. Therefore, cementitious waste forms are being evaluated as a cost-effective supplemental waste treatment, focusing on the solidification/immobilization of Land Disposal Restricted (LDR) organics, which is currently not recognized by the Environmental Protection Agency (EPA) as a standard treatment method (40 CFR 268.42). Previous efforts by the EPA and waste management agencies have highlighted the potential for cementitious materials to retain certain organic species through physical (encapsulation) and chemical (sorption) interactions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Fundamental Understanding of Aluminum Chemistry and Interactions of Aluminate Anion with Co-Anions: ORNL Project Progress Report

The U.S. Department of Energy (DOE)’s Hanford Site in Washington State houses 177 underground storage tanks containing millions of gallons of nuclear and chemical waste with high aluminum content. Aluminum (Al) salt reactions with strong bases produce aluminum hydroxides, like boehmite (γ-AlOOH), which are main components of insoluble nuclear waste sludge. Understanding the morphology, crystallinity, and dissolution behavior of boehmite under waste tank conditions is necessary for improving waste management and mitigation strategies. The ORNL team uses in situ multimodal analysis strategy to study Al chemistry of simulated tank waste using microfluidic reactors and advanced chemical imaging and mass spectrometry (MS) techniques. Because the SALVI device is vacuum compatible and transferrable among different platforms, we can use it in scanning electron microscopy (SEM), vacuum ultraviolet single photon mass spectrometry (VUV SPI-MS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the chemical speciation and colloid stability in liquids in this project. Additionally, ex situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) spectroscopy can be used to verify particle phase to further the understanding of the Al-bearing phases. This report gives a summary of the technical progress of the ORNL tasks. A plan for year 2 performance is recommended in the summary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

FY25 Task 5: Small-Scale Mixing

The U.S. Department of Energy (DOE) Hanford Site has 177 underground storage tanks that contain a complex and diverse mix of chemical and radioactive wastes from past nuclear fuel reprocessing and waste management operations. The strategy of the DOE Hanford Field Office is to retrieve this waste, ~20 vol% of which is in the form of insoluble undissolved solids (UDS) or sludge, and treat it via immobilization at the Hanford Waste Treatment and Immobilization Plant (WTP). The diverse properties and characteristics of Hanford tank waste lead to major challenges related to its transport from the underground tanks to the WTP. These challenges, however, can be addressed by investigating the behavior of tank waste samples and simulant materials and evaluating their behavior against the capabilities of mixing and transport system designs that may be incorporated to retrieve and treat the waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration Test Report: Vacuum Thermal Desorption (VTD) Testing to Support West Area Waste Feed Test 2

Approximately 54 million gallons of radioactive and hazardous waste are stored in underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Waste Treatment and Immobilization Plant (WTP) is being constructed to immobilize the waste in glass waste forms. The baseline configuration of the WTP includes a Pretreatment Facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the non-radioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at a federal repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancing Even Gas Distribution in Porous Media with Radial Flow

Packed beds, such as those used in thermal energy storage (TES) systems, typically use flow from one end to the other. This axial flow configuration leads to inefficiencies due to dispersion effects and high pressure drop. Instead of axial flow, this work proposes radial flow in packed beds, where a central tube provides flow that transports fluid from the center to the bed’s wall. Radial flow could be a promising solution to increase the efficiency of charging/discharging processes in TES systems. For instance, studies have been conducted on the thermal behavior during the charging process using radial flow and axial flow, and it was found that radial flow is better than axial flow in terms of thermal performance, where more energy can be stored in the storage tank during the charging process. However, the design of the radial pipe should be optimized to improve even flow distribution. In this work, numerical investigations on different designs were analyzed to enhance even flow gas distribution in the porous media when using this radial technique. This work shows the impact of different parameters on the even flow distribution into the packed bed for two different designs: 1) one radial tube at the center to provide the radial flow along with an annular tube at the wall to receive the flow, and 2) one radial tube at the center and four radial tubes at the wall. Air was used as fluid and 6 mm alumina beads as packing materials. Computational fluid dynamics (CFD) models in COMSOL Multiphysics were used to simulate the behavior of air flow through the piping and packed bed. It was found that the flow into the bed from the radial tube can be affected by different parameters: space between the holes, size/diameter of the holes, number of segments/zones, number of the holes in each zone and the length of each zone.

Beck, David M.↗

Next Generation Multi-Use Heavy-Duty High-Flow Direct-Fill Hydrogen Refueling Station with Standardized Design (CRADA Final Report)

The Contractor will build a liquid hydrogen (LH2) fueling station model that is capable of simulating the amount of hydrogen transferred from the liquid storage tank to the vehicle, depending on the station’s design and control scheme. This modeling work will allow the Parties to seek the design and control scheme of an LH2 station that can fill a targeted number of vehicles while meeting a time-average flow rate of 10 kg/min for each fill. While evaluating a high dispensing performance station design and control scheme, the Contractor will analyze the design and control scheme are economically viable.

08 HYDROGEN↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗