Search NASA⌕ Search

SEARCH · Search NASA

Results for “stress voiding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Influence of Potassium Metal‐Support Interactions on Dendrite Growth

Abstract Combined synchrotron X‐ray nanotomography imaging, cryogenic electron microscopy (cryo‐EM) and modeling elucidate how potassium (K) metal‐support energetics influence electrodeposit microstructure. Three model supports are employed: O‐functionalized carbon cloth (potassiophilic, fully‐wetted), non‐functionalized cloth and Cu foil (potassiophobic, nonwetted). Nanotomography and focused ion beam (cryo‐FIB) cross‐sections yield complementary three‐dimensional (3D) maps of cycled electrodeposits. Electrodeposit on potassiophobic support is a triphasic sponge, with fibrous dendrites covered by solid electrolyte interphase (SEI) and interspersed with nanopores (sub‐10 nm to 100 nm scale). Lage cracks and voids are also a key feature. On potassiophilic support, the deposit is dense and pore‐free, with uniform surface and SEI morphology. Mesoscale modeling captures the critical role of substrate‐metal interaction on K metal film nucleation and growth, as well as the associated stress state.

Liu, Pengcheng↗

Shockwave dissipation by interface-dominated porous structures

The advent of additive manufacturing (AM) has enabled topological control of structures at the micrometer scale, transforming the properties of polymers for a variety of applications. Examples include tailored mechanical responses, acoustic properties, and thermal properties. Porous polymer materials are a class of materials used for shock and blast mitigation, yet they frequently possess a lack of structural order and are largely developed and evaluated via trial-and-error. Here, we demonstrate control of shockwave dissipation through interface-dominated structures prepared by AM using 2-photon polymerization. A fractal structure with voids, or free surfaces, arranged less than 100 μm apart, allows for rarefaction interactions on the timescale of the shockwave loading. Simulations and dynamic x-ray phase contrast imaging experiments show that fractal structures with interfaces assembled within a “critical” volume reduce shockwave stress and wave velocity by over an order of magnitude within the first unit cell.

36 MATERIALS SCIENCE↗

Mechanically graded granular scaffolds for osteochondral tissue engineering

Engineered scaffolds designed to approximate the mechanical microenvironment of the osteochondral unit often address this complexity using discrete, two-phase architectures that introduce mechanical discontinuities and interfacial stress concentrations rather than a contiguous stiffness transition. To address this challenge, we created a photoannealed polyethylene glycol (PEG) granular scaffold with a spatially controlled stiffness gradient within a cell-permissive, macroporous architecture. Stiffness was dictated by photoannealing microgels using a photomask. We tuned void volume and available surface area by varying microgel diameter and tested how mesenchymal stromal cells (MSCs) interpret local mechanical environments. MSCs exhibited position-dependent differences in morphology, cytoskeletal structure, matrix deposition, and lineage-specific gene expression within the gradient scaffolds. Softer regions supported rounded cell morphology and deposition of a glycosaminoglycan-rich matrix, whereas stiffer regions promoted cell elongation, increased cytoskeletal tension, and expression of mineral-associated markers. Gradients formed from smaller microgels magnified these spatial responses by increasing cellular confinement and adhesion site availability. Disruption of actomyosin contractility eliminated these regional differences, demonstrating that MSCs rely on tension-dependent mechanotransduction to interpret the gradient. These findings reveal that coupling microgel architecture with continuous stiffness transitions provides a tractable platform to study multiscale mechanobiologic regulation and spatially guide osteochondral tissue formation.

Biological and medical sciences↗

Influence of Potassium Metal-Support Interactions on Dendrite Growth

We report combined synchrotron X-ray nanotomography imaging, cryogenic electron microscopy (cryo-EM) and modeling elucidate how potassium (K) metal-support energetics influence electrodeposit microstructure. Three model supports are employed: O-functionalized carbon cloth (potassiophilic, fully-wetted), non-functionalized cloth and Cu foil (potassiophobic, nonwetted). Nanotomography and focused ion beam (cryo-FIB) cross-sections yield complementary three-dimensional (3D) maps of cycled electrodeposits. Electrodeposit on potassiophobic support is a triphasic sponge, with fibrous dendrites covered by solid electrolyte interphase (SEI) and interspersed with nanopores (sub-10 nm to 100 nm scale). Lage cracks and voids are also a key feature. On potassiophilic support, the deposit is dense and pore-free, with uniform surface and SEI morphology. Mesoscale modeling captures the critical role of substrate-metal interaction on K metal film nucleation and growth, as well as the associated stress state.

36 MATERIALS SCIENCE↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

1000 Wh L−1 lithium-ion batteries enabled by crosslink-shrunk tough carbon encapsulated silicon microparticle anodes

Abstract Microparticulate silicon (Si), normally shelled with carbons, features higher tap density and less interfacial side reactions compared to its nanosized counterpart, showing great potential to be applied as high-energy lithium-ion battery anodes. However, localized high stress generated during fabrication and particularly, under operating, could induce cracking of carbon shells and release pulverized nanoparticles, significantly deteriorating its electrochemical performance. Here we design a strong yet ductile carbon cage from an easily processing capillary shrinkage of graphene hydrogel followed by precise tailoring of inner voids. Such a structure, analog to the stable structure of plant cells, presents ‘imperfection-tolerance’ to volume variation of irregular Si microparticles, maintaining the electrode integrity over 1000 cycles with Coulombic efficiency over 99.5%. This design enables the use of a dense and thick (3 mAh cm–2) microparticulate Si anode with an ultra-high volumetric energy density of 1048 Wh L–1 achieved at pouch full-cell level coupled with a LiNi0.8Co0.1Mn0.1O2 cathode.

25 ENERGY STORAGE↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Accelerated Threshold Fatigue Crack Growth Effect-Powder Metallurgy Aluminum Alloy

Fatigue crack growth (FCG) research conducted in the near threshold regime has identified a room temperature creep crack growth damage mechanism for a fine grain powder metallurgy (PM) aluminum alloy (8009). At very low (Delta) K, an abrupt acceleration in room temperature FCG rate occurs at high stress ratio (R = K(sub min)/K(sub max)). The near threshold accelerated FCG rates are exacerbated by increased levels of K(sub max) (K(sub max) = 0.4 K(sub IC)). Detailed fractographic analysis correlates accelerated FCG with the formation of crack-tip process zone micro-void damage. Experimental results show that the near threshold and K(sub max) influenced accelerated crack growth is time and temperature dependent.

Piascik, R. S.↗

Atomistic modeling of tensile deformation and fracture of carbon fibers: Nanoscale stress redistribution, effect of local structural characteristics and nanovoids

The mechanisms of tensile deformation and fracture of carbon fibers are investigated in large-scale molecular dynamics simulations. The simulations performed for computational samples with different structural characteristics enable analysis of the structural sensitivity of the mechanical properties. It is found that the carbon fiber nanostructure can be represented by a fine (nanoscale) mixture of stiff and soft regions. Despite the nanoscale structural heterogeneity of the computational fibers, their fracture strain and tensile strength exceed the experimental values by almost an order of magnitude. Here, this observation is explained by the ability of the carbon fiber nanostructure, largely consisting of curved and folded layers of turbostratic carbon, to exhibit continuous nanoscale load redistribution during the deformation. The transient, fluid nature of a percolating cluster of stress-holding structural elements prevents stress localization at the early stage of the deformation and enables the fiber nanostructure to adapt to the increasing load. Overall, the results of the simulations suggest that the design of advanced carbon fiber manufacturing and post-processing methods focused on the elimination of critical mesoscopic structural defects (internal voids, foreign inclusions, and surface flaws) can yield a substantial increase in the strength and fracture strain of carbon fibers.

36 MATERIALS SCIENCE↗

Grain-boundary fracture mechanisms in Li 7 La 3 Zr 2 O 12 (LLZO) solid electrolytes: When phase transformation acts as a temperature-dependent toughening mechanism

Garnet-type, solid electrolytes, such as Li 7 La 3 Zr 2 O 12 (LLZO), are a promising alternative to liquid electrolytes for lithium-metal batteries. However, such solid-electrolyte materials frequently exhibit undesirable lithium (Li) metal plating and fracture along grain boundaries. In this work, we employ atomistic simulations to investigate the mechanisms and key fracture properties associated with intergranular fracture along one such boundary. Our results show that, in the case of a Σ5 (310) grain boundary, this boundary exhibits brittle fracture behavior, i.e. the absence of dislocation activity ahead of the propagating crack tip, accompanied with a decrease in work of separation, peak stress, and maximum stress intensity factor as the temperature increases from 300 K to 1500 K. As the crack propagates, we predict two temperature-dependent Li clustering regimes. For temperatures at or below 900 K, Li tends to cluster in the bulk region away from the crack plane driven by a void-coalescence mechanism concomitant a simultaneous cubic-to-tetragonal phase transition. The tetragonalization of LLZO in this temperature regime acts as an emerging toughening mechanism. At higher temperatures, this phase transition mechanism is suppressed leading to a more uniform distribution of Li throughout the grain-boundary system and lower fracture properties as compared to lower temperatures.

36 MATERIALS SCIENCE↗

Micturition patterns of an unrestrained chimpanzee under entrained and free running conditions.

A young male chimpanzee was subjected to 30 days of isolation. Urine volumes and voiding times were recorded every hour beginning 14 days prior to isolation, ending 6 days after isolation, and approximately 2 months later for 10 days as a control. Observed during most periods of the experiment were (1) clear circadian micturition rhythms with the voiding peak occurring immediately after the subject awoke and (2) urine flow rhythms with the maximum volume voided in the morning hours. A 24-hour rhythm was seen when the subject was entrained to 12L:12D treatments and 24.8-hour rhythm when he was exposed to continuous light. A possible underlying 24-hour micturition rhythm was also seen during the continuous light period. Distorted rhythm curves indicating possible stress were obtained for the pre-isolation adaptation period and the initial period of isolation. As time passed, the curves were more like the controls, perhaps indicating a decrease in stress.

Hoshizaki, T.↗

Development of Laser Fabricated Ti-6Al-4V

Laser Engineered Net Shaping (LENS) depositions with Ti-6Al-4V gas-atomized powder were accomplished at five different temperatures, ranging from 30 to 400 C, imposed on the base plate. These base plate temperatures were employed in an effort to relieve stresses which develop during the deposition. Warpage of the base plate was monitored. Only a slight decline in warpage was observed as the base plate temperature was increased. Results indicate that substrate temperatures closer to the stress relief minimum of 480 C would relieve deposition stresses, though process parameters would likely need to be modified to compensate for the higher base plate temperature. The compositions of the as-received powder and the LENS deposited material were chemically analyzed. The oxygen content of the LENS material was 0.154 wt.% which is less than the maximum impurity limit of 0.2 percent for commercial Ti-6Al-4V alloys, but is over the limit allowed in ELI grade (0.13 percent). The level of oxygen in the commercial base plate used was only 0.0635 percent. Tensile specimens were machined from the LENS deposited material and tested in tension at room temperature. The ultimate and yield tensile stresses of the LENS material were about 1200 and 1150 MPa respectively, which is about 20 percent higher than the strengths of wrought Ti-6Al-4V. The higher strength of the LENS material was due to its fine structure and high oxygen content. The LENS deposits were not fully dense; voids were frequent at the interfaces between deposited layers. These dispersed sheets of voids were parallel to the longitudinal axis of the resulting tensile specimens. Apparently there was sufficient continuous, fully dense material longitudinally to enable the high strengths. Ductility was low in the LENS material. Percent elongation at failure in the LENS material was near 4 percent, which is less than half of what is usually expected from Ti-6Al-4V. The low ductility was caused by high oxygen levels, and the presence of voids. It is likely that the relatively high scan speeds used in our depositions contributed to the lack of full density in our LENS material.

deGroh, Henry C., III↗

Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

Bismaleimide (BMI) resins are an attractive new addition to world-wide composite applications. This type of thermosetting polyimide provides several unique characteristics such as excellent physical property retention at elevated temperatures and in wet environments, constant electrical properties over a vast array of temperature settings, and nonflammability properties as well. This makes BMI a popular choice in advance composites and electronics applications [I]. Bismaleimide-2 (BMI-2) resin was used to infuse intermediate modulus 7 (IM7) based carbon fiber. Two panel configurations consisting of 4 plies with [+45deg, 90deg]2 and [0deg]4 orientations were fabricated. For tensile testing, a [90deg]4 configuration was tested by rotating the [0deg]4 configirration to lie orthogonal with the load direction of the test fixture. Curing of the BMI-2/IM7 system utilized an optimal infusion process which focused on the integration of the manufacturer-recommended ramp rates,. hold times, and cure temperatures. Completion of the cure cycle for the BMI-2/IM7 composite yielded a product with multiple surface voids determined through visual and metallographic observation. Although the curing cycle was the same for the three panellayups, the surface voids that remained within the material post-cure were different in abundance, shape, and size. For tensile testing, the [0deg]4 layup had a 19.9% and 21.7% greater average tensile strain performance compared to the [90deg]4 and [+45deg, 90deg, 90deg,-45degg] layups, respectively, at failure. For tensile stress performance, the [0deg]4 layup had a 5.8% and 34.0% greater average performance% than the [90deg]4 and [+45deg, 90deg, 90deg,-45deg] layups.

Ehrlich, Joshua W.↗

Effect of Re and Al additions on the microstructure and mechanical properties of Nb-18Ti-12W alloy

Microstructure and mechanical properties at 25–1200 °C of new refractory alloys, Nb-18Ti-12W (NTW), Nb-18Ti-12W-5Re (NTW-R) and Nb-18Ti-12W-5Re-1Al (NTW-RA), all compositions are in atomic percent, are reported. The alloys are developed as an alternative to a denser, more expensive and difficult-to-process refractory alloy WC-3009. After production by arc melting and hot isostatic pressing at 1400 °C, 207 MPa for 3 h, the alloys have a BCC crystal structure with the average grain size of ~150–200 μm and contain low volume fraction of (Ti,N)-rich precipitates near grain boundaries. NTW shows excellent malleability at all studied temperatures. Its yield stress at 25 °C, 1000 °C and 1200 °C is 874 MPa, 353 MPa and 202 MPa, respectively. The NTW-R and NTW-RA alloys are stronger at all the studied temperatures; however, they lack in compression ductility at 25 °C. As a result, extensive deformation twinning and formation of intergranular voids precede the fracture of these two alloys at 25 °C.

36 MATERIALS SCIENCE↗

Micro-tensile characteristics of As-fabricated and irradiated AGR-2 TRISO fuel particle buffer, IPyC, and buffer-IPyC interlayer regions

A recently developed micro-tensile sample preparation technique was implemented to evaluate the tensile strengths of the buffer, IPyC, and buffer-IPyC interlayer regions of the unirradiated and irradiated AGR-2 TRISO fuel particles. Understanding the mechanical properties of the buffer-IPyC interlayer is essential for developing thermomechanical models of buffer-IPyC separation, yet there is a lack of experimental data on its micro-tensile properties. TEM analysis was conducted on these regions to determine the microstructural changes relevant to the samples' tensile properties. In the unirradiated TRISO particle samples, the buffer layer demonstrated the weakest tensile strength, while the IPyC layer exhibited the highest. Conversely, in the irradiated TRISO particle samples, the buffer-IPyC interlayer region showed the lowest tensile strength, with the IPyC layer being the strongest. Fractures in the samples from the buffer-IPyC region predominantly occurred either in the buffer layer or at the buffer-IPyC interface. However, some buffer-IPyC interlayer samples displayed stress-strain and fracture behaviors more akin to the IPyC layer than the buffer layer. Analysis of diffraction patterns suggests that irradiation may have increased anisotropy in the three regions tested. Despite this suggested increase in anisotropy, there was no evidence that it affected the measured strengths. The irradiated TRISO particles demonstrated a considerable increase in void space and a decrease in ultimate tensile strength within the buffer-IPyC interlayer region due to the densification and contraction of the buffer layer. Minor variations in diffraction ring patterns were also observed. These changes, coupled with a significant reduction in the Weibull modulus/shape parameter, imply that irradiation-induced densification leads to tearing between the buffer and IPyC layers at locations of elevated porosity in the buffer-IPyC interlayer region.

Tristructural isotropic (TRISO)↗

Apollo 6, Anomaly Report No. 6: Abnormal Structural Performance During Launch Phase

Approximately 2 minutes 13 seconds after lift-off of the Apollo 6 mission, abrupt changes of strain, vibration, and acceleration measurements were indicated in the S-IVB, instrument unit, adapter, lunar module, and command and service modules; photographs showed objects coming from the area of the adapter. The adapter, however, continued to sustain the required loads with no impairment of the mission. The investigation was first focused upon the understanding of the coupled vibration modes and characteristics of the launch vehicle and spacecraft.' Extensive test programs were conducted. It was eventually concluded that the adapter failure was not caused by vibration. Extensive study of the airborne photography and other evidence indicated that a large area of the adapter had lost inner facesheet from the honeycomb sandwich panels. Loads and stresses resulting from vibration were determined to be insufficient to initiate such a failure. The investigation was then directed toward determining the range of pressures that could have been trapped in the Apollo 6 adapter sandwich panels, and toward determining the tolerance of the panels to withstand pressure with various degrees of flaws such as adhesive voids and facesheet dents. The degradation effects of moisture and heat exposure on the adhesive strength were also studied and tested. These tests and analyses led to the conclusion that pressure internal to the sandwich panels could have caused the failure, if a large flaw existed. The pressure buildup would have been caused by aerodynamic heating effects on air and moisture trapped in the panel. The probable cause of the failure was found in the original ultrasonic inspection scan record of the affected adapter panel. In the center of the region where the adapter failed, horizontally along the station 709 panel splice, the record contained two thick anomalous lines extending several feet. Without an X-ray record of this region, the significance of this particular scan record cannot be fully understood. However, since all other evidence had indicated that the adhesive had to be weakened in a rather large area to initiate the failure, the investigation was focused intently upon the station 709 splices of other adapters. Sufficient information was developed to verify that deficient assembly techniques have consistently resulted in abnormalities in the structure at this station. These abnormalities were identified in adapters 12, 13, 14, 15, and 16. Before the splice abnormalities were pinpointed, corrective action was taken to reduce pressure "buildup in the honeycomb panels and to reduce heat degrading effects on the adhesive. This was done by drilling vent holes in the inner facesheet and covering the outer facesheet with cork. The adapters having identified abnormalities in the station 709 splice are being repaired, and the contractor is investigating ways of avoiding these -abnormalities in panels yet to be bonded.

Source record↗

Probabilistic Simulation for Combined Cycle Fatigue in Composites

A methodology to compute probabilistic fatigue life of polymer matrix laminated composites has been developed and demonstrated. Matrix degradation effects caused by long term environmental exposure and mechanical/thermal cyclic loads are accounted for in the simulation process. A unified time-temperature-stress dependent multifactor interaction relationship developed at NASA Glenn Research Center has been used to model the degradation/aging of material properties due to cyclic loads. The fast probability integration method is used to compute probabilistic distribution of response. Sensitivities of fatigue life reliability to uncertainties in the primitive random variables (e.g., constituent properties, fiber volume ratio, void volume ratio, ply thickness, etc.) computed and their significance in the reliability-based design for maximum life is discussed. The effect of variation in the thermal cyclic loads on the fatigue reliability for a (0/+/- 45/90)s graphite/epoxy laminate with a ply thickness of 0.127 mm, with respect to impending failure modes has been studied. The results show that, at low mechanical cyclic loads and low thermal cyclic amplitudes, fatigue life for 0.999 reliability is most sensitive to matrix compressive strength, matrix modulus, thermal expansion coefficient, and ply thickness. Whereas at high mechanical cyclic loads and high thermal cyclic amplitudes, fatigue life at 0.999 reliability is more sensitive to the shear strength of matrix, longitudinal fiber modulus, matrix modulus, and ply thickness.

Chamis, Christos C.↗