Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

180 records · Page 10

Tangerine Dream: Observations of Titan from the Earth

From its discovery in 1655 by the Dutch astronomer Christiaan Huygens, Titan perplexed and confounded Earth-based astronomers for three centuries with its stubborn refusal to yield virtually any clues about its nature. Until the Voyager 1 1980, even fundamentals such as its true diameter, surface pressure, and major atmospheric gas were uncertain [1]. Most of the information we now know about Titan has been wrestled at great expense of time and effort by three spacecraft visitors: Voyager 1, Cassini and Huygens. So why then continue to bother with Earth-based telescopic observations? In this review talk I will describe how significant clues about Titan’s atmospheric composition began to emerge from ground-based observations in the 1940s through 1970s, in the run-up to the revolutionary Voyager 1 flyby. These included the discovery of methane [2], and other significant hydrocarbons including ethane and acetylene in Titan’s stratosphere [3, 4]. Further ground and space-based telescopic work in the 1980s and 1990s revealed the presence of the fourth most abundance gas, carbon monoxide [5], spotted for the first time the bright continent on Titan’s leading hemisphere now known as Xanadu [6], and the comings and goings of bright tropospheric clouds [7]. The Cassini-Huygens mission of 2004-2017 [8, 9] greatly expanded our knowledge of Titan, including the first in situ measurements of the atmosphere and detailed imaging of the surface. However in the two-decades long gap before the next mission, Dragonfly, reaches Titan we are finding new ways to further our knowledge of Titan using the current generation of telescopes and instruments. With high-resolution spectroscopy at infrared and sub-millimeter wavelengths we are finding new chemical constituents in the atmosphere, and even measuring wind fields at middle altitudes. I will conclude by discussing how the next generation of Earth and space-based telescopes and instruments promises yet more breakthroughs via astronomy, including with large aperture 30 and 40 meter class telescopes that will become available in the late 2020s, and spectroscopy with airborne

Titan↗

Relative Detectability of Iron-Bearing Phases for the Mars 2020 Sherloc Deep UV Raman Instrument: 1. Focusing on Carbonates

A deep ultraviolet (DUV) Raman and fluorescence instrument is a surface standoff instrument mounted on the robotic arm of the Mars 2020 (M2020) rover Perseverance, and it is a key element of the Scanning Habitable Environments with Luminescence for Organics and Chemicals (SHERLOC) investigation [1]. Measurement and science objectives include mineralogical and organic images (~100 μm/pixel) that map sub-millimeter spatial distributions and characterization of primary and secondary minerals, potential organics, and their interaction/alteration products. The results of data analysis pertain to understanding igneous and alteration processes on Mars through time, assessing habitability, evidencing in situ biosignatures, and, along with results from other Perseverance instruments, selecting samples to cache for Mars sample return. Acceptance of the SHERLOC investigation for the NASA M2020 mission [2] created a need for Mars-relevant DUV Raman spectra, particularly for inorganic materials [e.g., 3, 4]. As reported previously [e.g., 4, 5], phases with Fe cations as essential elements (e.g., siderite (FeCO3) and ankerite (FeCa(CO3)2) for carbonates) significantly hinder detection by DUV Raman because of intense absorption of incident and scattered DUV laser radiation by Fe cations. We report here the relative detectability of carbonates (Mg,Ca,Fe,Mn)CO3 by DUV Raman using a SHERLOC analog laboratory instrument.

R V Morris↗

The First Global 883 GHz Cloud Ice Survey: IceCube Level 1 Data Calibration, Processing and Analysis

Sub-millimeter (sub-mm, 200 - 1000 GHz) wavelengths contribute a unique capability to fill-in the sensitivity gap between operational visible/infrared (VIS/IR) and microwave (MW) remote sensing for atmosphere cloud ice and snow. Being able of penetrating cloud to measure cloud ice mass and microphysical properties in the middle to upper troposphere, this is a critical spectrum range for us to understand the connection between cloud ice and precipitation processes.5As the first space-borne 883 GHz radiometer, IceCube mission was NASA’s latest effort in spaceflight demonstration of a commercial sub-mm radiometer technology. Successfully launched from the International Space Station, IceCube is essentially a free-running radiometer and collected valuable 15-month measurements of atmosphere and cloud ice. This paper describes the detailed procedures for Level 1 data calibration, processing and validation. The scientific quality and values of IceCube data are then discussed, including radiative transfer model validation and evaluation, as well as the unique spatial distribution10and diurnal cycle of cloud ice that are revealed for the first time on a quasi-global scale at this frequency.

IceCube↗

The First Global 883 GHz Cloud Ice Survey: IceCube Level 1 Data Calibration, Processing and Analysis

Sub-millimeter (sub-mm, 200 - 1000 GHz) wavelengths contribute a unique capability to fill-in the sensitivity gap between operational visible/infrared (VIS/IR) and microwave (MW) remote sensing for atmosphere cloud ice and snow. Being able of penetrating cloud to measure cloud ice mass and microphysical properties in the middle to upper troposphere, this is a critical spectrum range for us to understand the connection between cloud ice and precipitation processes.5As the first space-borne 883 GHz radiometer, IceCube mission was NASA’s latest effort in spaceflight demonstration of a commercial sub-mm radiometer technology. Successfully launched from the International Space Station, IceCube is essentially a free-running radiometer and collected valuable 15-month measurements of atmosphere and cloud ice. This paper describes the detailed procedures for Level 1 data calibration, processing and validation. The scientific quality and values of IceCube data are then discussed, including radiative transfer model validation and evaluation, as well as the unique spatial distribution10and diurnal cycle of cloud ice that are revealed for the first time on a quasi-global scale at this frequency

Jie Gong↗

Verifying Mars 2020 Sampling and Caching Robotic Functions with Position Budgeting Process and Tool

The Mars 2020 Perseverance Rover was launched on July 30th, 2020 with one of the most complex robotic systems ever implemented on an interplanetary mission. Much of this robotic complexity resides in the Rover Sampling and Caching Subsystem (SCS) to enable collection of Martian samples for eventual return to earth and preparation of surfaces for close-up surface science observations. Two robotic arms are used by SCS: the large Robotic Arm (RA) positions the coring drill and science instruments mounted to the Turret for surface interactions, and the smaller Sample Handling Assembly (SHA) manipulates Sample Tube Assemblies (STA) within the Adaptive Caching Assembly (ACA) to prepare them for sample collection, processing, and hermetic sealing. The robotic arms interact with the Martian surface and other SCS components in many ways and in a variety of configurations, with positioning accuracy requirements ranging from tens of millimeters for some surface interactions down to sub-millimeter accuracy for some ACA interactions.This paper describes the process and tool used to calculate the SCS robotic interaction positioning budgets and verify the as-built hardware when delivered. To ensure that these robotic systems are able to perform their tasks, each robotic interaction with another element was broken down into its composite functions. To calculate a positioning budget margin for each function, an allowable was defined and then compared to the list of error sources that contribute to misalignment. Across the subsystem, over 250 functions were identified to be assessed, with almost 500 error sources feeding into their budget calculations. In addition to using as-built values in the budgets for SCS Verification and Validation (V&V) after the hardware was complete, these budgets were populated with design data during the design phase to identify areas of concern and guide hardware design to ensure positive position budget margins.Because of the size of the SCS team that had inputs to the positioning budgets and the sheer number of items in the budgets that needed to be created, updated, and verified, having a tool that would allow for simultaneous access and robust data integrity and processing was imperative. To accomplish this, a web-based MySQL database was created that allowed users to create function position budgets, link individual errors and allowables to them, and view function position budget margin reports. Each error and allowable records data for lateral, normal, angular, and clocking errors, with the ability to add as-built data for up to four different hardware builds. Margin reports can be generated for either design values alone or replacing design data with as-built data when available. These as-built reports are used for final verification of the SCS positioning requirements. Ultimately, the SCS positioning budget process and database tool led to successful interactions during test and an SCS robotic system that is ready to perform sample acquisition and caching on the surface of Mars.

Williams, Jeffrey↗

Kids Making Noise: Presenting Noise Spectra of Aluminum MKIDS for Astronomy

Since the field has identified microwave kinetic inductance detectors (MKIDs) as a competitive candidate for future applications in infrared and sub-millimeter wave detection, it is increasingly important to establish the materials and techniques that produce highly sensitive, well-understood, and consistent detectors. We present new noise power spectral density (PSD) measurements for several thin film (25nm) aluminum coplanar waveguide (CPW) microwave resonators. We include noise PSD measurements for several bath temperatures and photon occupation numbers. We examine the trends exhibited by the fractional frequency noise spectra of our detectors at 1 kHz as a function of bath temperature and power. For our lowest temperature data (58mK) and a readout power of -84 dBm we observe fractional frequency noise in the range Sбf / f r 2 = a few x10 -17 . We observe a roughly Sбf / f r 2 (1 kHz) ∝ Pint -0.5 relationship between internal power and fractional frequency noise at 1 kHz. We attempted more complex fits to the PSDs, but concluded that more measurements are needed to converge on meaningful fits to the data.

MKIDs↗

Nanostructured Tube Wakefield Accelerator

Unprecedented $\rm TeVm^{-1}$ acceleration gradients are modeled to be realizable using a nonlinear surface crunch-in mode in nanostructured tubes. This mode is realizable using advances in nanofabrication and solid energy density attosecond bunch compression. Three dimensional computational and analytical modeling demonstrates GeV energy gain in sub-millimeter long tubes with effective wall densities $n_{\rm t}\sim10^{22-24}\rm cm^{-3}$ and hundreds of nanometer core radius when driven by submicron near solid electron beams, $n_{\rm b}\sim0.05n_{\rm t}$. Besides the many $\rm TVm^{-1}$ average gradients, strong self-focusing and nanomodulation of the beam which increases its peak density and the wakefield strength also opens up controlled high-energy photon production.

43 PARTICLE ACCELERATORS↗

Radioimaging for real-time tracking of high-voltage breakdown

An interferometric radioimager provides real-time, high-fidelity radioimaging of high voltage breakdown (HVB) both internal and external to electrical components at sub-nanosecond and sub-millimeter resolution and has an ability to resolve multiple/spatially-extensive HVB simultaneously. Therefore, radioimaging can be used to screen for early life weakness/failure and enable non-destructive screening of defective electrical components. In particular, radioimaging can detect precursors to catastrophic HVB, allowing for early detection of weakness in critical electrical components. Radioimaging can also be used to track HVB and pinpoint defects in electrical components real time, including transformers, capacitors, cables, switches, and microelectronics.

Tilles, Julia Napolin↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Studying the Formation and Development of Molecular Clouds: With the CCAT Heterodyne Array Instrument (CHAI)

Surveys of all different types provide basic data using different tracers. Molecular clouds have structure over a very wide range of scales. Thus, "high resolution" surveys and studies of selected nearby clouds add critical information. The combination of large-area and high resolution allows Increased spatial dynamic range, which in turn enables detection of new and perhaps critical morphology (e.g. filaments). Theoretical modeling has made major progress, and suggests that multiple forces are at work. Galactic-scale modeling also progressing - indicates that stellar feedback is required. Models must strive to reproduce observed cloud structure at all scales. Astrochemical observations are not unrelated to questions of cloud evolution and star formation but we are still learning how to use this capability.

heterodyne sub-millimeter arrays↗

Low noise 1.2 THz SIS receiver

We prevent the development of a low noise SIS mixer for the 1.1-1.25 THz heterodyne receiver of FIRST space radiotelescope.

superconductor↗