Search NASA⌕ Search

SEARCH · Search NASA

Results for “supersaturation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Stratospheric CCN sampling program

When Mt. St. Helens produced several major eruptions in the late spring of 1980, there was a strong interest in the characterization of the cloud condensation nuclei (CCN) activity of the material that was injected into the troposphere and stratosphere. The scientific value of CCN measurements is two fold: CCN counts may be directly applied to calculations of the interaction of the aerosol (enlargement) at atmospherically-realistic relative humidities or supersaturations; and if the chemical constituency of the aerosol can be assumed, the number-versus-critical supersaturation spectrum may be converted into a dry aerosol size spectrum covering a size region not readily measured by other methods. The sampling method is described along with the instrumentation used in the experiments.

Rogers, C. F.↗

The CCN counter of the IOPG of Puy de Dome: Main characterisics and results of measurements

In performing the data analysis of the measurements achieved during the Workshop with the device, a global approach was preferred rather than an individual analysis, in order to illustrate some main characteristics in the behavior of the device with respect to a mean behavior resulting from a general survey of all the equipments involved in each experiment. The device tends generally to overestimate the CCN concentrations measured near the high supersaturations and sometimes underestimates the concentrations close to 0.1% or 0.2% of supersaturation. Despite the fact that it belongs to a type of static diffusion chamber, it shows, however, similar spectra to those obtained with other types of chambers (continuous flow diffusion chamber and haze chamber).

Serpolay, R.↗

UMR dual mode CCN counter (modes: CFD plus haze)

The chamber consists of two vertical plates 100 cm long in the vertical direction and 13 cm wide, with a 0.8 cm spacing between the plates. The haze mode is used for the nuclei active at supersaturations (S) from 0.0133 to 0.173%. In this mode the two plates are kept at the same temperature (25 C). In the CFD mode the supersaturation is determined by the temperature difference between the two plates. About 40 minutes is required to obtain a spectrum (5 values of S in the CFD mode, plus 7 values of S in the haze mode). About half of this time is used to adjust the temperatures and flows; the rest is used in actual counting of the nuclei. Comparisons of the counter to other types of counters are reported.

Alofs, D. J.↗

An airborne isothermal haze chamber

Thermal gradient diffusion cloud chambers (TGDCC) are used to determine the concentrations of cloud condensation nuclei (CCN) with critical supersaturations greater than or equal to about 0.2%. The CCN concentrations measured with the airborne IHC were lower than theoretically predicted by factors ranging between 7.9 and 9.0. The CCN concentrations measured with the airborne IHC were lower than the concentrations measured with the larger laboratory IHC's by factors ranging between 3.9 and 7.5. The bounds of the supersaturation ranges of the airborne IHC and the CSU-Mee TGDCC do not overlap. Nevertheless, the slopes of the interpolated data between the bounds agree favorably with the theoretical slopes.

Hindman, E. E.↗

An automatic light scattering CCN counter

The counter is a static thermal diffusion chamber which has been modified to include an optical system for the determination of droplet concentration by the measurement of scattered light. The determination of concentration is made by measurement of the peak scattered light signal from the cloud of growing droplets which is a function of both the droplet concentration and chamber supersaturation. Because the formation of the peak is related to the rate of growth of the droplets and sedimentation, both of which are determined by supersaturation, the system calibration can be uniquely determined by comparison with an absolute counter such as a static diffusion chamber with a photographic recording system.

Lala, G. G.↗

Modified MEE Industries static thermal gradient diffusion cloud chamber

The experiments performed at the Workshop were undertaken to confirm the calculated sample volume, determine the usable range of supersaturation, and minimum detectable size. Comparison of absolute CCN concentrations with other state-of-the-art continuous flow diffusion chambers at supersaturations near 1 percent indicated that the volume used produced CCN concentrations well within the range of CCN concentrations determined at the workshop. This agreement is interpreted to mean the sample volume was correct. Direct measurements of the beam geometry done in the laboratory indicated a factor of 4-5 error. This error is apparently due to the larger apparent visible beam diameter versus the actual usable beam diameter given the droplet illumination, chamber optical geometry, microscope optics and film characteristics.

Borys, R. D.↗

Drop processes in natural clouds

A model of the diffusive mixing of dry and cloudy air, a process considered to be fundamental to the development of natural clouds, is presented. Water drops are formed at the cloud base by condensation upon nuclei and as they rise they grow by vapor diffusion in the slightly supersaturated environment of the clouds. Turbulent mixing between cloudy air and undersaturated air entrained from outside produces fluctuations in supersaturation, not linked to changes in vertical velocity, which cause broadening of the condensate spectrum and the rapid production of droplets large enough to engage in growth by coalescence. The probabilities of permanent union or the production of satellite droplets following the collision of a pair of raindrops is a sensitive function of several parameters. In some circumstances electrohydrodynamic bursting may influence the properties of clouds.

Latham, J.↗

Measurements of natural ice nuclei with a continuous flow diffusion chamber

A description is given of a continuous flow diffusion chamber technique for measuring the atmospheric concentrations of natural C-F nuclei. It is noted that the same device can also measure deposition nuclei; these two modes can thus be separated and compared. The laminar flow characteristics allow the temperature and supersaturation to be calculated with a high degree of precision and confidence. The method avoids the problems of a supporting substrate and of concentrating the sample into a small volume (as for membrane filters). The present measurements of natural ice nucleus concentrations at +1 percent water supersaturation are found to be comparable to research aircraft measurements of ice crystal concentrations in winter cap clouds over Elk Mountain, Wyoming (Vali et al., 1982).

Rogers, D. C.↗

An ensemble formulation of PBL fluxes in a GCM

An ensemble approach is applied to Planetary Boundary Layer (PBL) calculations with the bulk Richardson number identified as the key parameter. An ensemble averaging calculation was carried out to rederive the bulk friction and heat transport coefficients for the mean condition. Two simulations are carried out and compared. Significant differences in PBL fluxes low level cloudiness, land surface roughness heights, and surface evaporation are noted between the modified and unmodified simulations. Modifications to the model were: (1) the relationship between actual and potential Effective Temperature (ET) to accord with Sud and Fennessy (1982); (2) maximum permissible instantaneous ET at any time is 1.5 mm per hr; (3) moisture distribution in low level cumulus convection to be consistent with no precipitation; (4) appearance of supersaturation clouds to be consistent with supersaturation condition at that level; (5) invoking a simple function for stomatal diffusion effect in the ET calculation.

Sud, Y. C.↗

Carbon, oxygen and their interaction with intrinsic point defects in solar silicon ribbon material: A speculative approach

Some background information on intrinsic point defects is provided and on carbon and oxygen in silicon in so far as it may be relevant for the efficiency of solar cells fabricated from EFG ribbon material. The co-precipitation of carbon and oxygen and especially of carbon and silicon self interstitials are discussed. A simple model for the electrical activity of carbon-self-interstitial agglomerates is presented. The self-interstitial content of these agglomerates is assumed to determine their electrical activity and that both compressive stresses (high self-interstitial content) and tensile stresses (low self-interstitial content) give rise to electrical activity of the agglomerates. The self-interstitial content of these carbon-related agglomerates may be reduced by an appropriate high temperature treatment and enhanced by a supersaturation of self-interstitials generated during formation of the p-n junction of solar cells. Oxygen present in supersaturation in carbon-rich silicon may be induced to form SiO, precipitates by self-interstitials generated during phosphorus diffusion. It is proposed that the SiO2-Si interface of the precipates gives rise to a continuum of donor stables and that these interface states are responsible for at least part of the light inhancement effects observed in oxygen containing EFG silicon after phosphorus diffusion.

Goesele, U.↗

Oxygen budget of a perennially ice-covered Antarctic lake

A bulk O2 budget for Lake Hoare, Antarctica, is presented. Five years of seasonal data show the lake to be persistently supersaturated with O2. Oxygen is carried into the lake in glacial meltstreams and is left behind when this water is removed as ice by ablation and sublimation. A diffusive loss of O2 from the lake through the summer moat is suggested. Measured values of the total O2 in the water column indicate that the time scale of O2 turnover is much longer than a year. Based on these results, it is suggested that the amount of O2 in the water does not change significantly throughout the year and that the lake is also supersaturated with N2.

Wharton, R. A., Jr.↗

Oxidation and reduction rates for organic carbon in the Amazon mainstream tributary and floodplain, inferred from distributions of dissolved gases

Concentrations of CO2, O2, CH4, and N2O in the Amazon River system reflect an oxidation-reduction sequence in combination with physical mixing between the floodplain and the mainstem. Concentrations of CO2 ranged from 150 microM in the Amazon mainstem to 200 to 300 microM in aerobic waters of the floodplain, and up to 1000 microM in oxygen-depleted environments. Apparent oxygen utilization (AOU) ranged from 80 to 250 microM. Methane was highly supersaturated, with concentrations ranging from 0.06 microM in the mainstem to 100 microM on the floodplain. Concentrations of N2O were slightly supersaturated in the mainstem, but were undersaturated on the floodplain. Fluxes calculated from these concentrations indicated decomposition of 1600 g C sq m y(-1) of organic carbon in Amazon floodplain waters. Analysis of relationships between CH4, O2, and CO2 concentrations indicated that approximately 50 percent of carbon mineralization on the floodplain is anaerobic, with 20 percent lost to the atmoshphere as CH4. The predominance of anaerobic metabolism leads to consumption of N2O on the flood plane. Elevated concentrations of CH4 in the mainstem probably reflect imput from the floodplain, while high levels of CO2 in the mainstem are derived from a combination of varzea drainage and in situ respiration.

Richey, Jeffrey E.↗

The solubility of hen egg-white lysozyme

The equilibrium solubility of chicken egg-white lysozyme in the presence of crystalline solid state was determined as a function of NaCl concentration, pH, and temperature. The solubility curves obtained represent a region of the lysozyme phase diagram. This diagram makes it possible to determine the supersaturation of a given set of conditions or to achieve identical supersaturations by different combinations of parameters. The temperature dependence of the solubility permits the evaluation of Delta-H of crystallization. The data indicate a negative heat of crystallization for the tetragonal crystal form but a positive heat of crystallization for the high-temperature orthorhombic form.

Howard, Sandra B.↗

Dynamics of exploding magma chambers: Implications for K-T volcanism and mass extinctions

Although it is well known that unconfined chemical explosives may yield pressures to several megabars on detonation in air, the explosive literature has yet to be accessed by some contributors to the volcanological literature who've indicated that pressures in excess of the overburden and/or tensile cannot be obtained. Idealized ballistic assessments of pressures internal to volcanoes yield pressures in the hundreds of kilobar range upon correction by addition of friction, etc. Previous assessments of exploding magma chamber pressure have been made from the characteristics of the Mt. St. Helens explosion. A variety of methods yield pressures of similar value: at least hundreds of kilobars. Such results are consistent with free energy requirements for quench supersaturation explosion, a process occurring in solidifying industrial melts. Several reviews of geochemical literature emphasize the carbon event at the Cretaceous-Tertiary (K-T) boundary as being an indicator of a massive dump of CO2 derived from the mantle and entering the atmosphere by extensive global volcanism. Oxygen isotope data indicates extreme warming at the end of the Cretaceous which is consistent with a greenhouse effect attending the CO2 event. Reaction rate equations for the quench supersaturation explosion mechanism indicated, are consistent with the rise in pressure to 30 kbar on solidification of magmatic melts, these pressures limited by the strength of the experimental apparatus.

Rice, A. R.↗

Radiative processes in upper tropospheric mixed-phase clouds

The diffusional mass evolution of hydrometeors in upper tropospheric clouds for various radiative conditions in the cloud and for varying ambient moisture supply is simulated using a time dependent microphysical model. Radiation can play an important role in this mass evolution when only one phase is present. When both liquid droplets and ice crystals are situated in a typical upper tropospheric environment and the moisture supply is limited, radiation produces only a minor effect on the mass evolution of the hydrometeors. In these cases ice crystals grow quickly at the expense of the droplets and the droplets evaporate within several minutes, even under water supersaturation conditions. Radiation does not significantly influence the evaporation rates of the droplets in the coexisting cases. In the absence of ice crystals and under certain radiative conditions, the droplets can survive when the environment is subsaturated. For other radiative conditiions, the droplets can evaporate when the environment is supersaturated.

Wesley, Douglas A.↗

Aerosol measurements in the stratocumulus project

Cloud Condensation Nuclei (CCN) and Condensation Nuclei (CN) were measured from the National Center for Atmospheric Research (NCAR) Electra throughout the marine stratocumulus project. The total particle concentration was measured with a condensation nucleus counter. The CCN were measured with the Desert Research Institute (DRI) instantaneous CCN spectrometer. This instrument simultaneously measures the concentration of aerosol active at up to 100 different critical supersaturations (Sc). This is accomplished by exposing the sample to a fixed supersaturation field and using the size of the droplets produced in this cloud chamber to deduce the Sc of the nuclei upon which they have grown. Droplet size is associated with Sc through a calibration which is accomplished by passing soluble aerosols of known size and composition through the cloud chamber. This procedure results in a calibration curve of Sc vs. droplet size. This then allows the channel number to be directly associated with Sc. Thus, number concentration vs. Sc is obtained and this is a CCN spectrum. Since the instrument operates continuously, the measurements at all Sc's are available simultaneously. Samples are drawn directly from the ambient air and data is displayed in nearly real time. Samples were integrated over times of about 10 seconds so that substantial spatial resolution is available. Calibrations were performed once or twice a day and were found to be consistent. Preliminary results are shown.

Hudson, James G.↗

Doppler indices of gas phase formation in hypobaric environments: Time-intensity analysis

A semi-quantitative method to analyze decompression data is described. It possesses the advantage that it allows a graded response to decompression rather than the dichotomous response generally employed. A generalized critical volume (C-V), or stoichiometric time-dependent equilibrium model is examined that relates the constant of the equation P sub i equals m P sub f plus b to variable tissue supersaturation and gas washout terms. The effects of the tissue ratio on gas phase formation indicate that a decreased ratio yields fewer individuals with Doppler detectable gas bubbles, but those individuals still present with Spencer Grade 3 or 4. This might indicate a local collapse of tissue saturation. The individuals with Grade 3 or 4 could be at risk for type 2 decompression sickness by transpulmonic arterialization. The primary regulator of the problems of decompression sickness is the reduction of local supersaturation, presumably governed by the presence and number of gas micronuclei. It is postulated that a reduction in these nuclei will favor a low incidence of decompression sickness in microgravity secondary to hypokinesia and adynamia.

Powell, Michael R.↗

CBr4 vapor growth morphologies near the polymorphic transition point. I - Single crystals. II - Crystals with large-angle grain boundaries

High-resolution microscopy and image processing were used to investigate morphological changes in CBr4 single crystals during growth from the vapor at various levels of supersaturation and at temperatures below the compound's polymorphic phase transition. It was found that, as the temperature increased at fixed supersaturations, the corners of the crystals became rounded as a result of thermal roughening; the rounding temperatures were different for crystallographically different corners. A study of CBr4 crystals with large-angle grain boundaries or twin boundaries (extended macrodefects), conducted at the temperature of polymorphic phase transition showed that the phase transition temperature, T(tr) and crystal surface morphology of these crystals depended on the presence or absence of extended macrodefects. Unlike the case of a perfect single crystal, where the T(tr) was about 46.75 C, the phase transition in crystals with extended macrodefects occurred significantly below 46.75.

Xiao, Rong-Fu↗