Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronization stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Evolution of the Southern Oscillation as observed by the Nimbus-7 ERB experiment

The Nimbus-7 satellite has been in a 955-km, sun-synchronous orbit since October 1978. The Earth Radiation Budget (ERB) experiment has taken approximately 8 years of high-quality data during this time, of which seven complete years have been archived at the National Space Science Data Center. A final reprocessing of the wide-field-of-view channel dataset is underway. Error analyses indicate a long-term stability of 1 percent better over the length of the data record. As part of the validation of the ERB measurements, the archived 7-year Nimbus-7 ERB dataset is examined for the presence and accuracy of interannual variations including the Southern Oscillation signal. Zonal averages of broadband outgoing longwave radiation indicate a terrestrial response of more than 2 years to the oceanic and atmospheric manifestations of the 1982-83 El Nino/Southern Oscillation (ENSO) event, especially in the tropics. This signal is present in monthly and seasonal averages and is shown here to derive primarily from atmospheric responses to adjustments in the Pacific Ocean. The calibration stability of this dataset thus provides a powerful new tool to examine the physics of the ENSO phenomena.

Ardanuy, Philip E.↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Relativistic theory for syntonization of clocks in the vicinity of the Earth

A well known prediction of Einstein's general theory of relativity states that two ideal clocks that move with a relative velocity, and are submitted to different gravitational fields will, in general, be observed to run at different rates. Similarly the rate of a clock with respect to the coordinate time of some spacetime reference system is dependent on the velocity of the clock in that reference system and on the gravitational fields it is submitted to. For the syntonization of clocks and the realization of coordinate times (like TAI) this rate shift has to be taken into account at an accuracy level which should be below the frequency stability of the clocks in question, i.e. all terms that are larger than the instability of the clocks should be corrected for. We present a theory for the calculation of the relativistic rate shift for clocks in the vicinity of the Earth, including all terms larger than one part in 10(exp 18). This, together with previous work on clock synchronization (Petit & Wolf 1993, 1994), amounts to a complete relativistic theory for the realization of coordinate time scales at picosecond synchronization and 10(exp -18) syntonization accuracy, which should be sufficient to accommodate future developments in time transfer and clock technology.

Wolf, Peter↗

Soil Moisture Active and Passive (SMAP) White-Painted Expanded Polystyrene (EPS) Radome Survivability Test

NASA's SMAP Mission launched in January 2015 into a 685 km near-polar, sun-synchronous orbit. The SMAP instrument architecture incorporates an L-band radar and radiometer which share a common feedhorn and mesh reflector. The instrument rotates about the nadir axis at approximately 15 rpm, thereby providing a conically scanning wide swath antenna beam that is capable of achieving global coverage within three days. The radiometer and its associated electronics have tight thermal stability requirements in order to meet the required surface emittance measurement precision from space. Maintaining the thermal stabilities is quite challenging because the radiometer is located on a spinning platform that can either be in full sunlight or eclipse, and thus exposed to a highly transient environment. Stability requirements were met by integrating a light-weight Expanded Polystyrene (EPS) radome into the design to prevent solar illumination of the feed horn interior. The radome was painted white since the thermo-optical properties of bare sunlit EPS degrade rapidly over the three-year mission. Milling of the EPS and solvent within the white paint created cavities on the EPS surface which may introduce localized hot spots possibly violating the EPS glass transition temperature of 96degC and leading to structural integrity concerns. A three-day thermal test was conducted in a vacuum chamber to verify survivability of the radome during a simulated non-spin fault condition at end of mission. A portable solar simulator illuminated the test article and the beam irradiance was kept nearly constant during the entire 50 hour test, except during the first hour which simulated the expected 79degC on-orbit surface temperature of the radome. The test article survived based on the established pass criteria for three separate metrics: dimensional, optical property, and color. If any hot spots exist locally, they did not cause any observable permanent deformation when compared to pre- and post-test images. The test results increase confidence that there is a high probability that the radome will survive the worst-case scenario of a no-spin fault condition at the end of mission.

Mikhaylov, Rebecca↗

Numerical Simulation of Rolling-Airframes Using a Multi-Level Cartesian Method

A supersonic rolling missile with two synchronous canard control surfaces is analyzed using an automated, inviscid, Cartesian method. Sequential-static and time-dependent dynamic simulations of the complete motion are computed for canard dither schedules for level flight, pitch, and yaw maneuver. The dynamic simulations are compared directly against both high-resolution viscous simulations and relevant experimental data, and are also utilized to compute dynamic stability derivatives. The results show that both the body roll rate and canard dither motion influence the roll-averaged forces and moments on the body. At the relatively, low roll rates analyzed in the current work these dynamic effects are modest, however the dynamic computations are effective in predicting the dynamic stability derivatives which can be significant for highly-maneuverable missiles.

Murman, Scott M.↗

Submicrosecond comparison of intercontinental clock synchronization by VLBI and the NTS satellite

The intercontinental clock synchronization capabilities of Very Long Baseline Interferometry (VLBI) and the Navigation Technology Satellite (NTS) were compared in May 1978 by using both methods to synchronize the cesium clocks at the NASA Deep Space Net complexes at Madrid, Spain, and Goldstone, California. The VLBI experiments used the Wideband VLBI Data Acquisition System. The Navigation Technology Satellites were used with NTS Timing Receivers developed by the Goddard Space Flight Center. The two methods agreed at about the one-half microsecond level. The VLBI system also obtained long-term stability information on the HP5061A004 cesium standards by measuring delta T/T over four 3- to 4-day intervals, obtaining stability estimates of (1 + or - 1)x10 to the -13th power for the combined timing systems.

Hurd, W. J.↗

Electromagnetic propulsion alternatives

Mass drivers can serve to propel massive objects by expelling any available material as reaction mass, however, mass driver engines have several limitations such as relatively large payload size and dynamic stability problems. A number of alternative acceleration mechanisms exist which offer advantages for certain applications, such as higher acceleration at a sacrifice in efficiency, smaller possible size and decreased complexity at a sacrifice in service life, etc. The alternative concepts include several variants of the railgun, a family of superconducting slingshot oscillators, a momentum transformer, an impulse induction motor, and a family of hybrid synchronous accelerators. A potential application of considerable interest is the earth-based launching of space cargo or nuclear waste by using off-peak generating capacity to accelerate one ton cargo cylinders at intervals of several minutes.

Kolm, H.↗

Space Technology 5 Observations of Auroral Field-Aligned Currents

During its three month long technology validation mission, Space Technology 5 (ST-5) returned high quality multi-point measurements of the near-Earth magnetic field. Its three micro-satellites were launched into a 300 x 4500 km, dawn - dusk, sun synchronous orbit (inclination = 105.60) orbit with a period of 138 min by a Pegasus launch vehicle on March 22, 2006. The spacecraft were maintained in a "pearls on a sting" constellation with controlled spacings ranging from just over 5000 km down to under 50 km. The individual micro-satellites were 48 cm tall octagons with diameters of 50 cm. They were spin-stabilized at approximately 20 rpm at deployment and slowly spun-down to about 15 rpm by the end of the mission. Each spacecraft carried a miniature tri-axial fluxgate magnetometer (MAG) provided by the University of California at Los Angeles mounted at the end of a ultra-low mass 72 cm boom. These data allow, for the first time, the separation of temporal and spatial variations in field-aligned current (FAC) perturbations measured in low-Earth orbit on time scales of 10 sec to 10 min. The constellation measurements are used to directly determine field-aligned current sheet motion, thickness. and current density. Two multi-point methods for the inference of FAC current density that have not previously been possible in low-Earth orbit are demonstrated: 1) the -standard method." based upon s/c velocity, but corrected for FAC current sheet motion. and 2) the "gradiometer method" which uses simultaneous magnetic field measurements at two points with known separation. Future studies will apply these methods to the entire ST-5 data sct and expand to include horizontal ionospheric currents. ULF waves and geomagnetic field gradient analyses.

Slavin, James↗

DSN research and technology support

Continuing remote controlled pulsar observations are noted, along with routine observations of 22 pulsars. Preliminary installation of equipment for planned unattended operation of the Venus Station is reported, along with extensive measurements and performance evaluation of the 26-m antenna. Support of the X-band radar at the Mars Station (DSS 14), and stability and reliability testing of the DSS 13 receiving system is reported. Klystron testing and other DSN support activities of the DSN High-Power Transmitter Maintenance Facility are noted, along with energy conservation modifications to two buildings at DSS 13. Radio Science experiment support included Planetary Radio Astronomy, Pulsar Rotation Constancy, Interstellar Microwave Spectroscopy, and Very Long Baseline Interferometry observations. An increased schedule of clock synchronization transmissions, planned on five-day centers, is noted, as 39 transmissions were made to Australia, DSS 43, and Spain, DSS 63.

Jackson, E. B.↗

Community Coordinated Modeling Center Support of Operations: Real-Time Simulations and V & V.

In support of Operations Community Coordinated Modeling Center (CCMC) performing validation and verification of space weather models. To identify suitable metrics the CCMC focus on parameters most useful to operations that CCMC resident models can provide. The real time simulations carried out at CCMC are an essential tool to test model performance and stability by using input conditions that may occur in nature at any time. Since 2001, the magnetospheric MHD model BATSRUS has been run in real time using ACE real time data. CCMC staff developed an experimental real-time system that controls uploading of the real-time ACE data, monitors continuous model execution, initiates automatic recovery procedure in case of data gaps or hardware failures, synchronizes BATSRUS and FRC runs, and periodically runs IDL based visualization software.

Kuznetsova, M.↗

Stabilization of gaze during circular locomotion in darkness. II. Contribution of velocity storage to compensatory eye and head nystagmus in the running monkey

1. Yaw eye in head (Eh) and head on body velocities (Hb) were measured in two monkeys that ran around the perimeter of a circular platform in darkness. The platform was stationary or could be counterrotated to reduce body velocity in space (Bs) while increasing gait velocity on the platform (Bp). The animals were also rotated while seated in a primate chair at eccentric locations to provide linear and angular accelerations similar to those experienced while running. 2. Both animals had head and eye nystagmus while running in darkness during which slow phase gaze velocity on the body (Gb) partially compensated for body velocity in space (Bs). The eyes, driven by the vestibuloocular reflex (VOR), supplied high-frequency characteristics, bringing Gb up to compensatory levels at the beginning and end of the slow phases. The head provided substantial gaze compensation during the slow phases, probably through the vestibulocollic reflex (VCR). Synchronous eye and head quick phases moved gaze in the direction of running. Head movements occurred consistently only when animals were running. This indicates that active body and limb motion may be essential for inducing the head-eye gaze synergy. 3. Gaze compensation was good when running in both directions in one animal and in one direction in the other animal. The animals had long VOR time constants in these directions. The VOR time constant was short to one side in one animal, and it had poor gaze compensation in this direction. Postlocomotory nystagmus was weaker after running in directions with a long VOR time constant than when the animals were passively rotated in darkness. We infer that velocity storage in the vestibular system had been activated to produce continuous Eh and Hb during running and to counteract postrotatory afterresponses. 4. Continuous compensatory gaze nystagmus was not produced by passive eccentric rotation with the head stabilized or free. This indicates that an aspect of active locomotion, most likely somatosensory feedback, was responsible for activating velocity storage. 5. Nystagmus was compared when an animal ran in darkness and in light. the beat frequency of eye and head nystagmus was lower, and the quick phases were larger in darkness. The duration of head and eye quick phases covaried. Eye quick phases were larger when animals ran in darkness than when they were passively rotated. The maximum velocity and duration of eye quick phases were the same in both conditions. 6. The platform was counterrotated under one monkey in darkness while it ran in the direction of its long vestibular time constant.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

SE-FIT

The mathematical theory of capillary surfaces has developed steadily over the centuries, but it was not until the last few decades that new technologies have put a more urgent demand on a substantially more qualitative and quantitative understanding of phenomena relating to capillarity in general. So far, the new theory development successfully predicts the behavior of capillary surfaces for special cases. However, an efficient quantitative mathematical prediction of capillary phenomena related to the shape and stability of geometrically complex equilibrium capillary surfaces remains a significant challenge. As one of many numerical tools, the open-source Surface Evolver (SE) algorithm has played an important role over the last two decades. The current effort was undertaken to provide a front-end to enhance the accessibility of SE for the purposes of design and analysis. Like SE, the new code is open-source and will remain under development for the foreseeable future. The ultimate goal of the current Surface Evolver Fluid Interface Tool (SEFIT) development is to build a fully integrated front-end with a set of graphical user interface (GUI) elements. Such a front-end enables the access to functionalities that are developed along with the GUIs to deal with pre-processing, convergence computation operation, and post-processing. In other words, SE-FIT is not just a GUI front-end, but an integrated environment that can perform sophisticated computational tasks, e.g. importing industry standard file formats and employing parameter sweep functions, which are both lacking in SE, and require minimal interaction by the user. These functions are created using a mixture of Visual Basic and the SE script language. These form the foundation for a high-performance front-end that substantially simplifies use without sacrificing the proven capabilities of SE. The real power of SE-FIT lies in its automated pre-processing, pre-defined geometries, convergence computation operation, computational diagnostic tools, and crash-handling capabilities to sustain extensive computations. SE-FIT performance is enabled by its so-called file-layer mechanism. During the early stages of SE-FIT development, it became necessary to modify the original SE code to enable capabilities required for an enhanced and synchronized communication. To this end, a file-layer was created that serves as a command buffer to ensure a continuous and sequential execution of commands sent from the front-end to SE. It also establishes a proper means for handling crashes. The file layer logs input commands and SE output; it also supports user interruption requests, back and forward operation (i.e. undo and redo), and others. It especially enables the batch mode computation of a series of equilibrium surfaces and the searching of critical parameter values in studying the stability of capillary surfaces. In this way, the modified SE significantly extends the capabilities of the original SE.

Chen, Yongkang↗

The Global Precipitation Measurement (GPM) Microwave Imager (GMI): Instrument Overview and Early On-Orbit Performance

The Global Precipitation Measurement (GPM) mission is an international satellite mission that uses measurements from an advanced radar/radiometer system on a core observatory as reference standards to unify and advance precipitation estimates made by a constellation of research and operational microwave sensors. The GPM core observatory was launched on February 27, 2014 at 18:37 UT in a 65◦ inclination nonsun-synchronous orbit. GPM focuses on precipitation as a key component of the Earth's water and energy cycle, and has the capability to provide near-real-time observations for tracking severe weather events, monitoring freshwater resources, and other societal applications. The GPM microwave imager (GMI) on the core observatory provides the direct link to the constellation radiometer sensors, which fly mainly in polar orbits. The GMI sensitivity, accuracy, and stability play a crucial role in unifying the measurements from the GPM constellation of satellites. The instrument has exhibited highly stable operations through the duration of the calibration/validation period. This paper provides an overview of the GMI instrument and a report of early on-orbit commissioning activities. It discusses the on-orbit radiometric sensitivity, absolute calibration accuracy, and stability for each radiometric channel. Index Terms-Calibration accuracy, passive microwave remote sensing, radiometric sensitivity.

GPM↗

Comparison of synchronization of primate circadian rhythms by light and food

It is a well-documented fact that cycles of light and dark (LD) are the major entraining agent or 'zeitgeber' for circadian rhythms and that cycles of eating and fasting (EF) are capable of synchronizing a few circadian rhythms in the squirrel monkey. In this paper, by contrasting how these rhythms are timed by LD and EF cycles, the differential coupling to the oscillating system within adult male squirrel monkeys is examined. The variables measured are the rhythms of drinking, colonic temperature, and urinary potassium and water excretion. Attention is given to a comparison of the reproducibility of the averaged waveforms of the rhythms, the stability of the timing of a phase reference point, and the rate of resynchronization of these rhythms following an abrupt 8-hr phase delay in the zeitgeber. It is shown that the colonic temperature rhythm is more tightly controlled by LD than EF cycles, and that the drinking and urinary rhythms are more tightly coupled to EF than LD cycles.

Sulzman, F. M.↗

Overview of the Landsat-7 Mission

Landsat-7 is scheduled for launch on April 15 from the Western Test Range at Vandenberg Air Force Base, Calif., on a Delta-H expendable launch vehicle. The Landsat 7 satellite consists of a spacecraft bus being provided by Lockheed Martin Missiles and Space (Valley Forge, Pa.) and the Enhanced Thematic Mapper Plus instrument built by Raytheon (formerly Hughes) Santa Barbara Remote Sensing (Santa Barbara, Calif.). The instrument on board Landsat 7 is the Enhanced Thematic Mapper Plus (ETM+). ETM+ improves upon the previous Thematic Mapper (TM) instruments on Landsat's 4 and 5 (Fig. la and lb). It includes the previous 7 spectral bands measuring reflected solar radiation and emitted thermal emissions but, in addition, includes a new 15 in panchromatic (visible-near infrared) band. The spatial resolution of the thermal infrared band has also been improved to 60 m. Both the radiometric precision and accuracy of the sensor are also improved from the previous TM sensors. After being launched into a sun-synchronous polar orbit, the satellite will use on-board propulsion to adjust its orbit to a circular altitude of 438 miles (705 kilometers) crossing the equator at approximately 10 a.m. on its southward track. This orbit will place Landsat 7 along the same ground track as previous Landsat satellites. The orbit will be maintained with periodic adjustments for the life of the mission. A three-axis attitude control subsystem will stabilize the satellite and keep the instrument pointed toward the Earth to within 0.05 degrees. Later this year, plans call for the NASA Earth Observation System (EOS) Terra (AM-1) observatory and the experimental EO-1 mission to closely follow Landsat-7's orbit to support synergistic research and applications from this new suite of terrestrial sensor systems. Landsat is the United States' oldest land-surface observation satellite system, with satellites continuously operating since 1972. Although the program has scored numerous successes in scientific and resource-management applications, Landsat has had a tumultuous history of management and funding changes over its nearly 27-year history. Landsat-7 marks a new direction in the program to reduce the cost of data and increase systematic global coverage for use in global change research as well as commercial and regional applications. With the passage of the Land Remote Sensing Policy Act in 1992, oversight of the Landsat program began to shift from the commercial sector to the federal government. NASA integrated Landsat-7 into its EOS science program in 1994. Landsat-7 is managed and operated jointly by NASA and U.S. Geological Survey (USGS). As a result, the costs of acquiring observations from

Williams, Darrel↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗