Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Infrared scanner concept verification test report

The test results from a concept verification test conducted to assess the use of an infrared scanner as a remote temperature sensing device for the space shuttle program are presented. The temperature and geometric resolution limits, atmospheric attenuation effects including conditions with fog and rain, and the problem of surface emissivity variations are included. It is concluded that the basic concept of using an infrared scanner to determine near freezing surface temperatures is feasible. The major problem identified is concerned with infrared reflections which result in significant errors if not controlled. Action taken to manage these errors result in design and operational constraints to control the viewing angle and surface emissivity.

Bachtel, F. D.↗

Arabidopsis fad4 mutant analysis provides insights into thermo sensing within plant plasma membrane

Increasing evidence suggests that the plasma membrane is the initial site for temperature sensing. In searching for the contributions of membrane lipids to stress-induced cytosolic calcium, we found that FATTY ACID DESATURASE 4 (FAD4) knockout mutant exhibited an elevated acute cytosolic calcium spike in response to heat shock or oxidative stress, but not cold shock. fad4 mutant plants are more tolerant to heat stress but less tolerant to cold or high light stress. Lipidomic profiling demonstrated that overall phosphatidylglycerol (PG) levels, specifically, PG (36:7) levels, were reduced in the plasma membrane of fad4 mutants. Based on liposome binding assays, calcium channel proteins annexin2 and annexin4 showed higher association with fad4 plasma membranes compared to wild type (WT) control. Fat Western analyses indicated that anionic lipids, including phosphatidylserine (PS), phosphatidic acid (PA), and PG, bind to annexin1, 2, 3, and 4 with variable affinity, with PS binding the most tightly and PG the least. These results support the hypothesis that the plasma membrane is the initial site of thermo sensing in Arabidopsis.

annexins↗

A simple method to incorporate water vapor absorption in the 15 microns remote temperature sounding

The water vapor absorption in the 15 micron CO2 band, which can affect the remotely sensed temperatures near the surface, are estimated with the help of an empirical method. This method is based on the differential absorption properties of the water vapor in the 11-13 micron window region and does not require a detailed knowledge of the water vapor profile. With this approach Nimbus 4 IRIS radiance measurements are inverted to obtain temperature profiles. These calculated profiles agree with radiosonde data within about 2 C.

Dallu, G.↗

Estimation of Regional Evapotranspiration Using Remotely Sensed Land Surface Temperature. Part 2: Application of Equilibrium Evaporation Model to Estimate Evapotranspiration by Remote Sensing Technique

In a humid region like Japan, it seems that the radiation term in the energy balance equation plays a more important role for evapotranspiration then does the vapor pressure difference between the surface and lower atmospheric boundary layer. A Priestley-Taylor type equation (equilibrium evaporation model) is used to estimate evapotranspiration. Net radiation, soil heat flux, and surface temperature data are obtained. Only temperature data obtained by remotely sensed techniques are used.

Kotoda, K.↗

High-Performance Atomically-Thin Room-Temperature NO 2 Sensor

The development of room-temperature sensing devices for detecting small concentrations of molecular species is imperative for a wide range of low-power sensor applications. Here, we demonstrate a room-temperature, highly sensitive, selective, and reversible chemical sensor based on a monolayer of the transition metal dichalcogenide Re 0.5 Nb 0.5 S 2 . The sensing device exhibits thickness dependent carrier type, and upon exposure to NO 2 molecules, its electrical resistance considerably increases or decreases depending on the layer number. The sensor is selective to NO 2 with only minimal response to other gases such as NH 3 , CH 2 O, and CO 2 . In the presence of humidity, not only are the sensing properties not deteriorated, but also the monolayer sensor shows complete reversibility with fast recovery at room temperature. We present a theoretical analysis of the sensing platform and identify the atomically-sensitive transduction mechanism.

47 OTHER INSTRUMENTATION↗

Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer

Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Method and apparatus for measuring temperatures in fabrics and flexible thermal insulations

A temperature sensor uses a type R thermocouple wire element in a ceramic sheath to sense temperatures up to 3,200 deg F., and is particularly suitable for flexible insulations. The sensor includes a thermocouple wire embedded in a sheath having two sections disposed at right angles to each other. The junction of the thermocouple is located at one end of one of the sections and the lead wires extend from the other section. The section which includes the junction is secured to a flexible surface with ceramic cement.

Kourtides, Demetrius A.↗

Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration

Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.

Distributed Strain Sensing↗

Design and evaluation of a low-cost sensor node for near-background methane measurement

Abstract. We developed a low-cost methane sensing node incorporating two metal oxide (MOx) sensors (Figaro Engineering TGS2611-E00 and TGS2600), humidity and temperature sensing, data storage, and telemetry. We deployed the prototype sensor alongside a reference methane analyzer at two sites: one outdoors and one indoors. We collected data at each site for several months across a range of environmental conditions (particularly temperature and humidity) and methane levels. We explored calibration models to investigate the performance of our system and its suitability for methane background monitoring and enhancement detection, first selecting a linear regression to fit a sensor baseline response and then fitting methane response by the sensor deviation from baseline. We achieved moderate accuracy in a 2 to 10 ppm methane range compared to data from the reference analyzer (RMSE < 0.6 ppm), but we found that the sensor response varied over time, possibly as a result of changes in non-targeted gas concentrations. We suggest that this cross sensitivity may be responsible for mixed results in previous studies. We discuss the implications of our results for the use of these and similar inexpensive MOx sensors for methane monitoring in the 2 to 10 ppm range.

Furuta, Daniel↗

Experimental testing of additively manufactured embedded fiber optic smart devices for clean energy applications

Abstract An additively manufactured prototype smart device was created to investigate in-flow temperature distributions using embedded high-definition fiber optic sensors within a component for clean energy systems. The devices were created using Ultrasonic Additive Manufacturing to create a unique embedded pathway within a flow conditioner for the high-definition fiber optic sensors to be placed within. The fibers used allowed for temperature measurements to be taken every 0.65 mm along the fiber. The high-resolution fibers were thermally calibrated enable the 2D reconstruction of the temperature profile in the flow path of the structure. This is due to the temperature-related strain response of the material and strain measurements of the fibers. Hot airflow testing of these devices showed the ability to identify localized temperature differences in the flow. The observed strain response within the smart device had higher strain concentrations in the thicker web regions than in the thinner web regions. These higher strain regions resulted in higher uncertainties for the temperature responses. Further calibration is needed to improve the accuracy of the smart devices, specifically within the inner web structures of a flow straightening component. Further investigations of the devices within flow showed the temperature sensing to be independent of the effects of flow velocity. The devices were able to distinguish temperature differences within single and two-phase flow and showed local sensitivity to the temperature changes with the identification of hot and cold spots. The presented results showed the viability of the smart device for obtaining detailed temperature distributions using common industrial components. Eventually, the goal for these smart devices will be to withstand higher temperature and pressure environments such as those experienced in nuclear, fusion, and concentrated solar energy systems.

Donlan, Connor F. (ORCID:0000000223317882)↗

Optimal determination of geopotential base height for stratospheric temperature sounders

A technique is presented by which a geopotential base height between 100 and 10 mbar may be estimated to serve as a reference for the construction of stratospheric height fields from remotely sensed temperatures. The scheme employs conventional data obtained below 100 mbar coupled with remotely sensed observations above this level to derive an accurate estimate of the height field by the minimization of the error at the tie-on level, the pressure level of the base height. In a series of numerical realizations, it is demonstrated that the technique yields an unbiased and optimal estimate of the height at levels where conventional errors are typically large, particularly where the conventional height error grows rapidly in the vertical.

Salby, M. L.↗

Electronic clinical predictive thermometer using logarithm for temperature prediction

A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.

Cambridge, Vivien J.↗

Water frost and ice - The near-infrared spectral reflectance 0.65-2.5 microns

The spectral reflectance of water frost and frost on ice as a function of temperature and grain size is presented with 1-1/2% spectral resolution in the 0.65- to 2.5-micron wavelength region. The well-known 2.0-, 1.65-, and 1.5-micron solid water absorption bands are precisely defined along with the little studied 1.25-micron band and the previously unidentified (in reflectance) 1.04-, 0.90-, and 0.81-micron absorption bands. The 1.5-microns band complex is quantitatively analyzed using a nonlinear least squares algorithm to resolve the band into four Gaussian components as a function of grain size and temperature. It is found that the 1.65-micron component, which was thought to be a good temperature sensor, is highly grain-size dependent and poorly suited to temperature sensing. Another Gaussian component appears to show a dependence of width on grain size while being independent of temperature. The relative apparent band depths are different for frost layers on ice than for thick layers of frost and may explain the apparent band depths seen in many planetary reflectance spectra.

Clark, R. N.↗

A machine learning approach for determining temperature-dependent bandgap of metal oxides utilizing Allen–Heine–Cardona theory and O’Donnell model parameterization

To evaluate the high temperature sensing properties of metal oxide and perovskite materials suitable for use in combustion environments, it is necessary to understand the temperature dependence of their bandgaps. Although such temperature-driven changes can be calculated via the Allen–Heine–Cardona (AHC) theory, which assesses electron–phonon coupling for the bandgap correction at given temperatures, this approach is computationally demanding. Another approach to predict bandgap temperature-dependence is the O’Donnell model, which uses analytical expressions with multiple fitting parameters that require bandgap information at 0 K. This work employs data-driven Gaussian process regression (GPR) to predict the parameters employed in the O’Donnell model from a set of physical features. We use a sample of 54 metal oxides for which density functional theory has been performed to calculate the bandgap at 0 K, and the AHC calculations have been carried out to determine the shift in the bandgap at non-zero temperatures. As the AHC calculations are impractical for high-throughput screening of materials, the developed GPR model attempts to alleviate this issue by predicting the O'Donnell parameters purely from physical features. To mitigate the reliability issues arising from the very small size of the dataset, we apply a Bayesian technique to improve the generalizability of the data-driven models as well as quantify the uncertainty associated with the predictions. The method captures well the overall trend of the O’Donnell parameters with respect to a reduced feature set obtained by transforming the available physical features. Quantifying the associated uncertainty helps us understand the reliability of the predictions of the O’Donnell parameters and, therefore, the bandgap as a function of temperature for any novel material.

36 MATERIALS SCIENCE↗

Incorporating geometric and radiative effects into infrared scanning computer analysis

A NASA program, the SILTS experiment (Shuttle Infrared Leeside Temperature Sensing) will utilize an infrared scanning system mounted at the tip of the vertical stabilizer to remotely measure the surface temperature of the leeside of the Space Shuttle during entry from orbit. Scans of the fuselage and one wing will be made alternately. The experiment will correlate real full scale data to ground-based information. In order to quantitatively assess the temperature profile of the surface, an algorithm is required which incorporates the Space Shuttle shape, location of specific materials on the surface, and the measurement geometry between the camera and the surface. This paper will discuss the algorithm.

Myrick, D. L.↗

An initialization procedure for assimilating geostationary satellite data into numerical weather prediction models

An attempt was made to offset the limitations of GEO satellites for supplying timely initialization data for numerical weather prediction models (NWP). The NWP considered combined an isentropic representation of the free atmosphere with a sigma-coordinate model for the lower 200 mb. A flux form of the predictive equations described vertical transport interactions at the boundary of the two model domains, thereby accounting for the poor vertical temperature and wind field resolution of GEO satellite data. A variational analysis approach was employed to insert low resolution satellite-sensed temperature data at varying rates. The model vertical resolution was limited to that available from the satellite. Test simulations demonstrated that accuracy increases with the frequency of data updates, e.g., every 0.5-1 hr. The tests also showed that extensive cloud cover negates the capabilities of IR sensors and that microwave sensors will be needed for temperature estimations for 500-1000 mb levels.

Gal-Chen, T.↗

Apparatus Would Measure Temperatures Of Ball Bearings

Rig for testing ball bearings under radial and axial loads and measuring surface temperatures undergoing development. Includes extensible thermocouples: by means of bellows as longitudinal positioners, thermocouples driven into contact with bearing balls to sense temperatures immediately after test run. Not necessary to disassemble rig or to section balls to obtain indirect indications of maximum temperatures reached. Thermocouple measurements indicate temperatures better than temperature-sensitive paints.

Gibson, John C.↗