Direct correlation of test-analysis cross-orthogonality

This paper presents an alternative to the correlation of individual components of a mode shape vectors by directly examining the sensitivity of the cross-orthogonality between test and analytical mode shapes. If the test and analysis mode shapes are identical, the diagonal elements of the cross-orthogonality will be identical to the test orthogonality matrix, so the cross-orthogonality matrix provides a concise measure of the 'closeness' between test and analysis mode shapes. There are two major advantages to the cross-orthogonality correlation approach. The first is that a direct correlation of this matrix will more directly meet the goal of the correlation effort (measured by cross-orthogonality). Secondly, and more importantly, the correlation of cross-orthogonality greatly reduces the amount of data that needs to be handled when compared to the correlation of mode shapes.

Blelloch, P. A.↗

Test and Analysis Correlation for Sandwich Composite Longitudinal Joint Specimens

The NASA Composite Technology for Exploration (CTE) project is tasked with evaluating methods to analyze and manufacture composite joints for potential use in block upgrades to the Space Launch System (SLS) launch-vehicle structures such as the Payload Attach Fitting (PAF). To perform this task, the CTE project has initiated test and analysis correlation studies for composite joints under various loading conditions. Herein, NASA-developed numerical models are correlated with the experimental results from a series of tension tests. Pretest strain results matched the far-field test data well, but did not capture the nonlinear response in the vicinity of the joint. A refined pretest analytical model was modified to represent progressive failure of the specimens at failure locations observed during the experimental tests. The nonlinear strain response from this progressive failure model predicted the delamination failure load within 15% of the test data, but underpredicted the nonlinearity of the strain response. Further study of composite material models that account for the nonlinear shear response of fabric composites is recommended for the composite joint structures considered in this paper.

Mason, Brian H.↗

Testing and Analysis Correlation of a Large-Scale Composite Sandwich Longitudinal Bonded Joint for Space Launch Vehicle Structures

The NASA Composite Technology for Exploration (CTE) Project is developing and demonstrating critical composite technologies with a focus on composite bonded joints; incorporating materials, design/analysis, manufacturing, and tests that utilize NASA’s expertise and capabilities. The project has goals of advancing composite technologies and providing lightweight structures to support future NASA exploration missions. In particular, the CTE project will demonstrate weight-saving, performance-enhancing composite bonded joint technology for Space Launch System (SLS)-scale composite hardware. Advancements from the CTE project may be incorporated as future block upgrades for SLS structural components. This paper discusses the details of the development of a composite sandwich bonded longitudinal joint for a generic space launch vehicle structure called the CTE Point Design. This paper reports on the large-scale longitudinal bonded joint test articles that were fabricated and tested under axial compressive loading conditions to test the capability of the bonded joint design for buckling and joint failure. Test and analysis correlation of an as-manufactured undamaged longitudinal bonded joint panel are presented in the paper for tests to the onset of buckling and panel failure. Analysis predictions for buckling initiation and panel failure were both within 10% of the longitudinal bonded joint panel test results. This testing and analysis provide confidence in the potential use of composite bonded joints for future launch vehicle structures.

David W Sleight↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Thermal↗

Six-Tube Freezable Radiator Testing and Model Correlation

Freezable radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recovering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TradeMark) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested, namely MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

Lillibridge, Sean↗

Six-Tube Freezable Radiator Testing and Model Correlation

Freezable Radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft?s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recov ering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TM) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested: MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

Lilibridge, Sean T.↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Correlation↗

A linearized model of helicopter dynamics including correlation with flight test

A linearized model for rotorcraft dynamics has been developed through the use of symbolic automatic equation generation techniques. The dynamic model has been formulated in a unique way such that it can be used to analyze a variety of rotor/body coupling problems including a rotor mounted on a flexible shaft with a number of modes as well as free flight stability and control characteristics. Direct comparison of the time response to longitudinaol, lateral and directional control inputs at various trim conditions shows that the linear model yields good to very good correlation with flight test. In particular it is also shown that a dynamic inflow model is essential to obtain good time response correlation especially for the hover trim condition and also that at translational flight trim conditions the main rotor wake interaction with the tail rotor and fixed tail surfaces is a significant contributor to the response. A relatively simple model for the downwash and sidewash at tail surfaces based on flat vortex wake theory is shown to produce good agreement. Finaly, the influence of rotor flap and lag dynamics on automatic control systems feedback gain limitations is investigated with the model.

Curtiss, H. C.↗

Ground correlation investigation of thruster/spacecraft interactions to be measured on the IAPS flight test

Preliminary ground correlation testing has been conducted with an 8 cm mercury ion thruster and diagnostic instrumentation replicating to a large extent the IAPS flight test hardware, configuration, and electrical grounding/isolation. Thruster efflux deposition retained at 25 C was measured and characterized. Thruster ion efflux was characterized with retarding potential analyzers. Thruster-generated plasma currents, the spacecraft common (SCC) potential, and ambient plasma properties were evaluated with a spacecraft potential probe (SPP). All the measured thruster/spacecraft interactions or their IAPS measurements depend critically on the SCC potential, which can be controlled by a neutralizer ground switch and by the SPP operation.

Power, J. L.↗

The correlation of laboratory test results with behavior in real fires

Laboratory tests have been condemned as misleading because they do not always predict behavior in real fires. General condemnation seems unjustified in the light of available data. Many laboratory tests are employed with the purpose of eliminating fire hazard by preventing ignition, and fires that did not happen provide no data for correlation. Correlations are sometimes attempted between a laboratory test which emphasizes one fire response characteristic and a fire situation in which the hazard relates to a different fire response characteristic. Correlations may fail in particular cases, but in general, something less likely to burn or emit undesirable products in a laboratory test is less likely to be a hazard in a real fire.

Hilado, C. J.↗

Testing and Model Correlation of Sublimator Driven Coldplate Coupons and EDU

The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a more traditional thermal control system. The principal advantage is the possible elimination of a pumped fluid loop, potentially saving mass, power, and complexity. Because this concept relies on evaporative heat rejection techniques, it is primarily useful for short mission durations. Additionally, the concept requires a conductive path between the heat-generating component and the heat rejection device. Therefore, it is mostly a relevant solution for a vehicle with a relatively low heat rejection requirement and/or short transport distances. Tests were performed on coupons and an Engineering Development Unit (EDU) at NASA s Johnson Space Center to better understand the basic operational principles and to validate the analytical methods being used for the SDC development. This paper outlines the results of the SDC tests, the subsequent thermal model correlation, and a description of the SDC Engineering Development Unit test results.

Leimkuehler, Thomas O.↗

Ground correlation investigation of thruster spacecraft interactions to be measured on the IAPS flight test

Preliminary ground correlation testing has been conducted with an 8 cm mercury ion thruster and diagnostic instrumentation replicating to a large extent the IAPS flight test hardware, configuration, and electrical grounding/isolation. Thruster efflux deposition retained at 25 C was measured and characterized. Thruster ion efflux was characterized with retarding potential analyzers. Thruster-generated plasma currents, the spacecraft common (SCC) potential, and ambient plasma properties were evaluated with a spacecraft potential probe (SPP). All the measured thruster/spacecraft interactions or their IAPS measurements depend critically on the SCC potential, which can be controlled by a neutralizer ground switch and by the SPP operation.

Power, J. L.↗

Modal Test and Analysis Correlation of Wind Tunnel Blades for the National Transonic Facility

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the agency . Wind tunnel blades, such as the ones in the National Transonic Facility at NASA Langley Research Center, have been subjected to damage from impacts and fatigue. Accurate analytical models of these blades are necessary to either recertify replacement blades to be built or for redesign of these blades. In this paper an upgraded finite element model of these wind tunnel blades with the capability of representing damage is presented. An eigenvalue analysis of the structural model is performed, and the boundary conditions are adjusted to simulate the natural frequencies obtained by experimental testing of a set of twenty five blades in 1992. Additional numerical studies of the effect of delamination damage on the natural frequencies of the blade are conducted using the tuned finite element model.

wind tunnel↗

Modal Test and Analysis Correlation of Wind Tunnel Blades for the National Transonic Facility

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the agency . Wind tunnel blades, such as the ones in the National Transonic Facility at NASA Langley Research Center, have been subjected to damage from impacts and fatigue. Accurate analytical models of these blades are necessary to either recertify replacement blades to be built or for redesign of these blades. In this paper an upgraded finite element model of these wind tunnel blades with the capability of representing damage is presented. An eigenvalue analysis of the structural model is performed, and the boundary conditions are adjusted to simulate the natural frequencies obtained by experimental testing of a set of twenty five blades in 1992. Additional numerical studies of the effect of delamination damage on the natural frequencies of the blade are conducted using the tuned finite element model.

wind tunnel↗

Using Digital Image Correlation for Material Testing at Cryogenic Temperatures

Recent efforts were made to parametrize an aluminum alloy at cryogenic temperatures to calibrate finite element models simulating material deformation. Digital image correlation (DIC) was used to measure material properties using front/back strains of specimens during tensile tests. Data acquired from DIC was compared to physical extensometer measurements. Two camera pairs (front and back) were mounted via aluminum extrusion to the exterior of an environmental chamber of a hydraulic test stand. Images were taken through single-pane optical glass windows of the environment chamber. Positive pressure bags encased the cameras, attaching to the perimeter of the glass to keep out moisture and prevent windows from frosting. Figure 1 shows the environmental setup and the camera setup during cryogenic testing. Some of the challenges during testing at cryogenic temperatures include the gaseous flow of liquid nitrogen in the optical path of the mounted cameras, frost buildup on the windows as seen in Figure 1b, and frost on the test coupon. The temperature gradient present during the introduction of liquid nitrogen into the chamber can increase the projection error of images captured of the specimen. Figure 2 shows the estimated projection error from DIC as a function of temperature during the cool down process. This presentation addresses some of the concerns and observations when using DIC for testing at cryogenic temperatures using methods of isolated camera system and techniques for maintaining the glass panel clear from frost.

Joseph Cochran↗

Testing and Model Correlation of Sublimator Driven Coldplate Coupons

The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially saving mass, power, and complexity. Because this concept relies on evaporative heat rejection techniques, it is primarily useful for short mission durations. Additionally, the concept requires a conductive path between the heat-generating component and the heat rejection device. Therefore, it is mostly a relevant solution for a vehicle with a relatively low heat rejection requirement. Coupon level tests were performed at NASA's Johnson Space Center to better understand the basic operational principles and to validate the analytical methods being used for the SDC development. This paper outlines the results of the SDC coupon tests, the subsequent thermal model correlation, and a description of the SDC Engineering Development Unit design.

Sheth, Rubik↗

Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

Mason, Brian H.↗