Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Effects of Optical Artifacts in a Laser-Based Spacecraft Navigation Sensor

Testing Of the Advanced Video Guidance Sensor (AVGS) used for proximity operations navigation on the Orbital Express ASTRO spacecraft exposed several unanticipated imaging system artifacts and aberrations that required correction, to meet critical navigation performance requirements. Mitigation actions are described for a number of system error sources, including lens aberration, optical train misalignment, laser speckle, target image defects, and detector nonlinearity/noise characteristics. Sensor test requirements and protocols are described, along with a summary ,of test results from sensor confidence tests and system performance testing.

LeCroy, Jerry E.↗

Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

NASA Discipline Cardiopulmonary↗

Test results on re-use of reclaimed shower water: Summary

A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.

Verostko, C. E.↗

28,000 Hour Xenon Hollow Cathode LifeTest Results

The International Space Station Plasma Contactor System requires a hollow cathode assembly (HCA) with a lifetime of at least 18,000 hours. Critical components of the HCA include the hollow cathode and electron emitter. A series of hollow cathode wear tests was performed which included a life test operated at the maximum current of the HCA. This test sought to verify the hollow cathode design and contamination control protocols. The life test accumulated 27,800 hours of operation before failing to ignite. The hollow cathode exhibited relatively small changes in operating parameters over the course of the test. This life test is the longest duration test of a high current xenon hollow cathode reported to date.

Sarver-Verhey, Timothy R.↗

A Method for Assessing Material Flammability for Micro-Gravity Environments

On a spacecraft, one of the greatest fears during a mission is the outbreak of a fire. Since spacecraft are enclosed spaces and depend highly on technical electronics, a small fire could cause a large amount of damage. NASA uses upward flame spread as a "worst case scenario" evaluation for materials and the Heat and Visible Smoke Release Rates Test to assess the damage potential of a fire. Details of these tests and the protocols followed are provided by the "Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion" document. As pointed by Ohlemiller and Villa, the upward flame spread test does not address the effect of external radiation on ignition and spread. External radiation, as that coming from an overheated electrical component, is a plausible fire scenario in a space facility and could result in a reversal of the flammability rankings derived from the upward flame spread test. The "Upward Flame Propagation Test" has been the subject of strong criticism in the last few years. In many cases, theoretical exercises and experimental results have demonstrated the possibility of a reversal in the material flammability rankings from normal to micro-gravity. Furthermore, the need to incorporate information on the effects of external radiation and opposed flame spread when ranking materials based on their potential to burn in micro-gravity has been emphasized. Experiments conducted in a 2.2 second drop tower with an ethane burner in an air cross flow have emphasized that burning at the trailing edge is deterred in micro-gravity due to the decreased oxygen transport. For very low air flow velocities (U<0.005 m/s) the flame envelopes the burner and a slight increase in velocity results in extinction of the trailing edge (U>0.01 m/s). Only for U>0.l m/s extinction is observed at the leading edge (blow-off). Three dimensional numerical calculations performed for thin cellulose centrally ignited with an axisymmetric source have shown that under the presence of a forced flow slower than 0.035 m/s flames spreads only opposing the flow. Extinction is observed at the trailing edge with no concurrent propagation. Experiments conducted by the same authors at the JAMIC 10 second drop tower verified these calculations. Reducing the oxygen supply to the flame also results in a decrease of the Damk6hler number which might lead to extinction. Greyson et al. and Ferkul conducted experiments in micro-gravity (5 second drop tower) with thin paper and observed that at very low flow velocities concurrent flame spread will stop propagating and the flame will reduce in size and extinguish. They noted that quenching differs significantly from blow-off in that the upstream leading edge will remain anchored to the burn out edge.

Steinhaus, T.↗

Evaluation of Volatile Species in Green Monopropellant Project

NASA is interested in green monopropellants to replace hydrazine in reaction control systems (RCSs). Some current NASA programs require reduced vapor pressure and low toxicity monopropellant (green) and superior performance (specific impulse and density) formulations. Earlier vapor phase studies of a candidate green monopropellant at the NASA White Sands Test Facility (WSTF) showed the presence of a volatile species that warranted further investigation. The purpose of this study was to further characterize the volatile species and to evaluate it. The evaluation was with respect to whether the volatile species was an impurity or how it is formed, and to use that information to examine whether its presence as an impurity can be eliminated during formulation. The evaluation also considered whether formation of the volatile impurity could be prevented while not compromising the propellant. To reduce variables associated with evaluation of the propellant formulation as a whole, a precursor to one of the individual components in the propellant formulation was subjected to a NASA Standard 6001B Flammability, Off-gassing, and Compatibility Requirements and Test Procedures "Determination of Off-gassed Products (Test 7)". Testing took place in the NASA WSTF Molecular Desorption and Analysis Laboratory. One gram of the precursor was placed in a flask within a specimen container. After thermal conditioning for 72 +/- 1 h at 50 +/- 3 deg C (122 +/- 5 deg F), the atmosphere inside the specimen container was analyzed for off-gassed compounds by cryotrap gas chromatography-mass spectrometry (GC-MS) and fixed sample loop GC-flame ionization detection (GC-FID). The specimen container used was glass to minimize potential catalytic surfaces. The identification of compounds was difficult due to the complexity of the vapor phase concentrations and overlapping chromatographic peaks and mass spectra. However, eleven compounds were specifically identified and five compounds or classes of compounds were reported as unidentified. Quantitation of most of the compounds, including unidentified compounds, was as methane. Quantitating compounds or classes of compounds that were detected but for which specific calibration is not established as methane is in accordance with the Test 7 standard protocol. The thermal decomposition temperature of the precursor was significantly higher than the test temperature. Based on thermal decomposition temperature and on an examination of the structure and chemistry of the identified volatile species, the presence of the volatile species appears to be chemically reasonable with respect to the propellant formulation and is at this time attributed to impurities. Further examination of the overall propellant formulation process (including the individual components' synthesis processes) and process quality control (including purity of reagents and possible decomposition reactions) is indicated.

Greene, Benjamin↗

Finalizing the CCSDS Space-Data Link Layer Security Protocol: Setup and Execution of the Interoperability Testing

The protection of data transmitted over the space-link is an issue of growing importance also for civilian space missions. Through the Consultative Committee for Space Data Systems (CCSDS), space agencies have reacted to this need by specifying the Space Data-Link Layer Security (SDLS) protocol which provides confidentiality and integrity services for the CCSDS Telemetry (TM), Telecommand (TC) and Advanced Orbiting Services (AOS) space data-link protocols. This paper describes the approach of the CCSDS SDLS working group to specify and execute the necessary interoperability tests. It first details the individual SDLS implementations that have been produced by ESA, NASA, and CNES and then the overall architecture that allows the interoperability tests between them. The paper reports on the results of the interoperability tests and identifies relevant aspects for the evolution of the test environment.

Fischer, Daniel↗

Experimental control in software reliability certification

There is growing interest in software 'certification', i.e., confirmation that software has performed satisfactorily under a defined certification protocol. Regulatory agencies, customers, and prospective reusers all want assurance that a defined product standard has been met. In other industries, products are typically certified under protocols in which random samples of the product are drawn, tests characteristic of operational use are applied, analytical or statistical inferences are made, and products meeting a standard are 'certified' as fit for use. A warranty statement is often issued upon satisfactory completion of a certification protocol. This paper outlines specific engineering practices that must be used to preserve the validity of the statistical certification testing protocol. The assumptions associated with a statistical experiment are given, and their implications for statistical testing of software are described.

Trammell, Carmen J.↗

The Functional Task Test: Results from the One-Year Mission

Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after landing. The FTT one-year results will be presented at the meeting, and a comparison will be made with data previously obtained using the same protocol on astronauts tested before and after 6 months in space. Future work will focus on collecting data from additional subjects from one-year flights to gain a better assessment of extreme long-duration exposure to spaceflight on both functional measure of performance and physiological metrics.

Bloomberg, J. J↗

Simulated Space Environmental Testing on Thin Films

An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.

Russell, Dennis A.↗

Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

Wright, Kenneth H.↗

Age Induced Effects on ESD Characteristics of Solar Array Coupons After Combined Space Environmental Exposures

A set of multi-junction GaAs/Ge solar array test coupons provided by Space Systems/Loral were subjected to a sequence of 5-year increments of combined space environment exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is performing electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO standard for ESD testing on solar array panels [ISO-11221]. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of four cells constructed to form two strings. The ESD tests were performed at the beginning-of-life (BOL) and at each 5-year environment exposure point until end-of-life (EOL) at 15 years. The space environmental exposure sequence consisted of ultra-violet radiation, electron/proton particle radiation, thermal cycling, and Xenon ion thruster plume erosion. This paper describes the ESD test setup and the importance of the electrical test design in simulating the on-orbit operational conditions. Arc inception voltage results along with ESD test behavior from the BOL condition through the 15th year age condition are discussed. In addition, results from a Xenon plasma plume exposure test with an EOL coupon under the full ESD test condition will be discussed.

Wright, Kenneth H.↗

Ocular Vestibular Evoked Myogenic Potentials Using Head Striker Stimulation

Introduction: Over the last two decades, several studies have been published on the impact of long-duration (i.e., 22 days or longer) spaceflight on the central nervous system (CNS). In consideration of the health and performance of crewmembers in flight and post-flight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Multiple studies have demonstrated the effects of spaceflight on the vestibular system. One of the supporting tests conducted in this protocol is the Vestibular Evoked Myogenic Potential (VEMP) test that provides a unilateral measure of otolith (saccule and utricle) function. A different approach was taken for ocular VEMP (oVEMP) testing using a head striker system (Wackym et al. 2012). The oVEMP is generally considered to be a measure of utricle function. The the otolithic input to the inferior oblique muscle is predominately from the utricular macula. Thus, quantitatively, oVEMP tests utricular function. Another practical extension of these relationships is that the oVEMP reflects the superior vestibular nerve function. Methods: Ground testing was administered on 16 control subjects and for 8 subjects over four repeated sessions spanning 70 days. The oVEMP was elicitied via a hand held striker by a vibrotactile pulse presented at the rate of 1 Hz for 24 seconds on the side of the head as subjects lay supine on a gurney. Subjects were directed to gaze approximately 25 degrees above straight ahead in semi-darkness. For the oVEMP electromyograms will be recorded with active bipolar electrodes (Delsys Inc., Boston, MA) on the infra-orbital ridge 1 cm below the eyelid with a reference electrode on the below the knee cap. The EMG potentials were amplified; band-pass filtered using a BagnoliTM Desktop EMG System (Delsys Inc., Boston, MA, USA). This EMG signal is sampled at 10 kHz and the data stimulus onset to 100 MS was averaged over 24 trial repetitions for the vibrotactile VEMP. The typical oVEMP EMG response is an excitatory potential with first peak occurring at 11-12 ms and second peak at 18 ms. This requires a total recording time of approximately 29 seconds per trial which includes 5 seconds of no vibrotactile stimulation at the beginning of the protocol. The primary dependent measures consist of the latency and peak-to-peak amplitude from the EMG signals, which will be normalized to EMG levels at the beginning of the protocol. Data were collected for 3 repeated trials with striker stimulation on both the left and right side of the head Results: The oVEMP p1 range was observed at 3-14 ms and n1 at 7-19 ms. The striker system provided a consistent and rapid method for oVEMP testing. Discussion: Crew testing is in progress to determine changes in results between pre and post flight.

De Dios, Y. E.↗

Space Link Extension Protocol Emulation for High-Throughput, High-Latency Network Connections

New space missions require higher data rates and new protocols to meet these requirements. These high data rate space communication links push the limitations of not only the space communication links, but of the ground communication networks and protocols which forward user data to remote ground stations (GS) for transmission. The Consultative Committee for Space Data Systems, (CCSDS) Space Link Extension (SLE) standard protocol is one protocol that has been proposed for use by the NASA Space Network (SN) Ground Segment Sustainment (SGSS) program. New protocol implementations must be carefully tested to ensure that they provide the required functionality, especially because of the remote nature of spacecraft. The SLE protocol standard has been tested in the NASA Glenn Research Center's SCENIC Emulation Lab in order to observe its operation under realistic network delay conditions. More specifically, the delay between then NASA Integrated Services Network (NISN) and spacecraft has been emulated. The round trip time (RTT) delay for the continental NISN network has been shown to be up to 120ms; as such the SLE protocol was tested with network delays ranging from 0ms to 200ms. Both a base network condition and an SLE connection were tested with these RTT delays, and the reaction of both network tests to the delay conditions were recorded. Throughput for both of these links was set at 1.2Gbps. The results will show that, in the presence of realistic network delay, the SLE link throughput is significantly reduced while the base network throughput however remained at the 1.2Gbps specification. The decrease in SLE throughput has been attributed to the implementation's use of blocking calls. The decrease in throughput is not acceptable for high data rate links, as the link requires constant data a flow in order for spacecraft and ground radios to stay synchronized, unless significant data is queued a the ground station. In cases where queuing the data is not an option, such as during real time transmissions, the SLE implementation cannot support high data rate communication.

Computer Networking↗

A Novel Method for Quantifying Helmeted Field of View of a Space Suit - And What it Means for Constellation

Field of view has always been a design feature paramount to helmet design, and in particular spacesuit design, where the helmet must provide an adequate field of view for a large range of activities, environments, and body positions. Historically, suited field of view has been evaluated either qualitatively in parallel with design or quantitatively using various test methods and protocols. As such, oftentimes legacy suit field of view information is either ambiguous for lack of supporting data or contradictory to other field of view tests performed with different subjects and test methods. This paper serves to document a new field of view testing method that is more reliable and repeatable than its predecessors. It borrows heavily from standard field of vision tests such as the Goldmann kinetic perimetry test, but is designed specifically for evaluating field of view of a spacesuit helmet. In this test, three suits utilizing three different helmet designs were tested for field of view. Not only do these tests provide more reliable field of view data for legacy and prototype helmet designs, they also provide insight into how helmet design impacts field of view and what this means for the Constellation Project spacesuit helmet, which must meet stringent field of view requirements that are more generous to the crewmember than legacy designs.

McFarland, Shane M.↗

A Novel Method for Quantifying Helmeted Field of View of a Spacesuit - And What It Means for Constellation

Field of view has always been a design feature paramount to helmet design, and in particular spacesuit design, where the helmet must provide an adequate field of view for a large range of activities, environments, and body positions. Historically, suited field of view has been evaluated either qualitatively in parallel with design or quantitatively using various test methods and protocols. As such, oftentimes legacy suit field of view information is either ambiguous for lack of supporting data or contradictory to other field of view tests performed with different subjects and test methods. This paper serves to document a new field of view testing method that is more reliable and repeatable than its predecessors. It borrows heavily from standard ophthalmologic field of vision tests such as the Goldmann kinetic perimetry test, but is designed specifically for evaluating field of view of a spacesuit helmet. In this test, four suits utilizing three different helmet designs were tested for field of view. Not only do these tests provide more reliable field of view data for legacy and prototype helmet designs, they also provide insight into how helmet design impacts field of view and what this means for the Constellation Project spacesuit helmet, which must meet stringent field of view requirements that are more generous to the crewmember than legacy designs.

McFarland, Shane M.↗

Standard Testing Procedure for Quantifying Breathing Gas Carbon Dioxide Partial Pressure for Extravehicular Activity and Launch, Entry, Survival Pressure Suits

This standard test and analysis protocol establishes the procedure for determining the partial pressure of inspired carbon dioxide (PICO2) exposure level experienced by persons operating a pressurized suit. The purpose of this Standard Testing Procedure (STP) is to describe the test conditions and procedures necessary to acquire data in support of certification that manufacturer submitted Extravehicular Activity (EVA) and/or Launch, Entry, Survival (LES) suit designs maintain safe levels of carbon dioxide (CO2) in the helmet during suited operations. The STP shall be used to measure the in-suit inhaled and exhaled dry-gas partial pressure of CO2 (PCO2), followed by calculation of the water vapor saturated PICO2 during the inhalation portion of the breathing cycle, while a human test subject is performing work at levels anticipated during suited operations in ground and flight environments. The procedure is designed to test the evaluated suit on a human test subject as a dynamic system, generate repeatable results under defined laboratory conditions, and perform consistent analysis on acquired samples.This STP is used to evaluate space suits in a hyperbaric environment (above atmospheric pressure). Changes would need to be made to the test equipment/setup to accommodate a hypobaric environment. There is no specific EVA or LES suit performance requirement to meet or pass/fail criteria associated with this STP.

Bekdash, Omar↗

An Approach to Evaluate Precision and Inter-Laboratory Variability of Flammability Test Methods for Aerospace Materials

Materials selection for spacecraft is based on conventional flammability or ignition sensitivity acceptance tests. Current procedures for determining the inter-laboratory repeatability and reproducibility of aerospace materials flammability tests are not considering the dependence of data variability on test conditions and consequently attempts to characterize the precision of these methods were not successful. The inter-laboratory data variability is determined with tests conducted under arbitrary conditions, which consequently may not provide sufficient information to enable adequate determination of a method's precision. For evaluating the precision of NASA's flammability test methods, the protocol recommended includes selecting critical parameters and determining the 50% failure point by considering the specific failure criteria of each method using the critical parameter as a variable. Upon performing inter-laboratory round robin testing using this approach, the laboratories' performance could be evaluated by comparing the repeatability of the 50% failure point and/or the repeatability of critical conditions where the probabilities of passing and failing are unity, i.e., the transition zone repeatability. When a sufficient amount of data has been acquired with this method, an adequate estimation of precision of aerospace materials flammability test methods will be possible.

Hirsch, David↗