Sensors for Using Times of Flight to Measure Flow Velocities

Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

Fralick, Gutave↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

Effects of exposure time during flight maneuvers on passenger subjective comfort rating

The effects were investigated of length of exposure time to a flight maneuver environment on subjective passenger evaluation of ride comfort. Four statistical analysis tests were performed on ride comfort ratings obtained during one two-hour test flight wherein eleven test subjects were exposed to two identical programmed sequences of twenty four flight segments which covered a wide range of maneuver conditions. The results of the analysis indicate that, for over ninety five percent of the segments, there is no significant change in the test subjects comfort ratings of identical segments spaced one hour apart. These results are in contrast to those found in previous studies involving a vibration environment, rather than flight maneuver environment, where increased exposure-time was found to cause a degradation of ride comfort ratings.

Brown, V. J.↗

Configuration management issues and objectives for a real-time research flight test support facility

An account is given of configuration management activities for the Western Aeronautical Test Range (WATR) at NASA-Ames, whose primary function is the conduct of aeronautical research flight testing through real-time processing and display, tracking, and communications systems. The processing of WATR configuration change requests for specific research flight test projects must be conducted in such a way as to refrain from compromising the reliability of WATR support to all project users. Configuration management's scope ranges from mission planning to operations monitoring and performance trend analysis.

Yergensen, Stephen↗

Transient Pulse-Response Time-of-Flight Mass Spectrometry for Complex, Deactivating Heterogeneous Catalytic Systems: Application to Ethane Dehydroaromatization

The study of complex, multistep bond-forming and -breaking reactions in heterogeneous catalytic systems often encounters challenges associated with the involvement of large numbers of intermediates among branching pathways. Kinetic information obtained from traditional steady-state measurements can be complemented with that from time-resolved methods to uncover details of the underlying chemistry. Herein, we describe an approach for tracking the complete time-resolved chemical composition (ca. 4–200 u) of a reactor effluent in response to a reactant pulse. We use a six-port rotary valve with a metered sampling loop to pulse reactants at ambient pressure into a flow reactor packed with a catalyst bed within the isothermal region of a heated furnace. The temporal evolution of effluent species is tracked using time-resolved molecular-beam time-of-flight mass spectrometry. We highlight the possibilities that this method has to offer by studying the complex bifunctional mechanism of ethane dehydroaromatization over an HZSM-5-supported platinum catalyst. We demonstrate that energy-tunable ionization sources, which facilitate isomer resolution, enable the measurement of the full mass spectral time-dependent system response. This includes the evolution of major products and mechanistically relevant reactive intermediates such as 1,3-butadiene and cyclopentadiene; these species have not previously been observed from this reaction. In additional studies, we also assess the role of platinum in the catalyst by examining temporal responses to ethane and ethylene feeds. Results show that two temporally distinct formation pathways exist for methane and benzene, and that their importance depends on both catalyst composition and reactant identity. Additionally, characteristics of catalyst deactivation are uniquely observable in the time-resolved mass spectral response, including the selective deactivation of a benzene formation pathway. The combination of time-of-flight mass spectrometry with tunable ionization enables the simultaneous observation of all effluents in a complex mixture of intermediates with isomer/isobar differentiation capabilities that can be applied to any complex reaction system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Effect of electron beam pulse width on time-of-flight spectra

A simple but useful formula describing the effect of electron gun pulse width on the time of flight (TOF) spectra measured in translational spectroscopy experiments is developed. An approximately monoenergetic pulsed electrostatically focused electron beam traverses a scattering cell filled with a Maxwellian gas. Inelastic electron collisions with the gas produce metastable particles, ions, scattered electrons, and photons which then pass through a collimating slit system at right angles to the electron beam. TOF techniques are used to separate the photon signal from the metastable particle signal and to measure the TOF distribution of the metastable species.

Misakian, M.↗

Configuration management issues and objectives for a real-time research flight test support facility

Presented are some of the critical issues and objectives pertaining to configuration management for the NASA Western Aeronautical Test Range (WATR) of Ames Research Center. The primary mission of the WATR is to provide a capability for the conduct of aeronautical research flight test through real-time processing and display, tracking, and communications systems. In providing this capability, the WATR must maintain and enforce a configuration management plan which is independent of, but complimentary to, various research flight test project configuration management systems. A primary WATR objective is the continued development of generic research flight test project support capability, wherein the reliability of WATR support provided to all project users is a constant priority. Therefore, the processing of configuration change requests for specific research flight test project requirements must be evaluated within a perspective that maintains this primary objective.

Yergensen, Stephen↗

Comparison of different noble gas injections by massive gas injection on plasma disruption mitigation on Experimental Advanced Superconducting Tokamak

Massive gas injection (MGI) is a traditional plasma disruption mitigation method. This method directly injected massive gas into the pre-disruption plasma and had been developed on the Experimental Advanced Superconducting Tokamak (EAST). Different noble gas injection experiments, including He, Ne, and Ar, were performed to compare the mitigation effect of plasma disruption by evaluating the key parameters such as flight time, pre-thermal quench (pre-TQ), and current quench (CQ). The flight time was shorter for low atomic number ( Z ) gas, and the decrease in flight time by increasing the amount of gas was insignificant. However, both pre-TQ and CQ durations decreased considerably with the increase in gas injection amount. The effect of atomic mass on pre-TQ and CQ durations showed the opposite trend. The observed trend could help in controlling CQ duration in a reasonable area. Moreover, the analysis of radiation distribution with different impurity injections indicated that low Z impurity could reduce the asymmetry of radiation, which is valuable in mitigating plasma disruption. These results provided essential data support for plasma disruption mitigation on EAST and future fusion devices.

Physics↗

STOPGAP—A time-of-flight extension for the Belle II TOP barrel PID system

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system. Due to its mechanical design, the individual TOP modules do not overlap, leaving a gap of around 2 cm between them in the azimuthal direction. This leads to a 6%–9% drop in acceptance, depending on the track’s momentum. We propose a solution to remedy these gaps by instrumenting them with fast silicon detectors to directly measure the time-of-flight of traversing particles. We present here a simulation study discussing the performance requirements and the possible sensor technologies, and we demonstrate that such a project could be realized with novel, fast monolithic CMOS sensors, or alternatively AC-LGAD sensors, both of which are expected to reach MIP timing resolutions of down to 50 ps or better.

Hartbrich, Oskar↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

140° Line of Sight (LOS) Mounting Fixture Prototype for ZNeutron Time of Flight (Z-NToF)

The 140° Line of Sight (LOS) Mounting Fixture Prototype for the Z-Neutron Time of Flight diagnostic (Z-NToF) is a prototype support structure for the NToF Jac Black that will be fielded at Sandia’s Z-Machine. The Mounting Fixture will allow the detector to be properly positioned and aligned horizontally from the load, with manual horizontal and vertical translation capabilities, and a limited manual rotation capability. It attaches overhead I-beams at Sandia’s Z machine 140° location approximately 18m from the average source location. The assembly (1011219955) is shown in Figure 1 below. It is capable of rotating ±20° about the vertical axis of the Jac Black detector and translating ±37.5mm horizontally along the Mounting Plate. Vertical adjustments of ±76.2mm can be made using the Lead Screw. Coarser adjustments are possible by changing the number of plates between the I-Beam Hanger Assemblies and the 5in and changing the position of the clamps on the I-beams at Z.

42 ENGINEERING↗

Improved time-of-flight mass spectrometer

External signal-conditioning electronics assembled from commercially available components improves dynamic capability of time-of-flight mass spectrometer.

Lincoln, K. A.↗

Automating Analysis of Neutron Scattering Time-of-Flight Single Crystal Phonon Data

This article introduces software called Phonon Explorer that implements a data mining workflow for large datasets of the neutron scattering function, S(Q, ω), measured on time-of-flight neutron spectrometers. This systematic approach takes advantage of all useful data contained in the dataset. It includes finding Brillouin zones where specific phonons have the highest scattering intensity, background subtraction, combining statistics in multiple Brillouin zones, and separating closely spaced phonon peaks. Using the software reduces the time needed to determine phonon dispersions, linewidths, and eigenvectors by more than an order of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Lorentz factor for time-of-flight neutron Bragg and total scattering

We report the three fundamental origins of the Lorentz factor for neutron time-of-flight powder diffraction are revisited. A detailed derivation of the Lorentz factor is presented in the context of diffuse scattering modelling in reciprocal space when perfect periodicity is assumed, and the total scattering pattern is constructed in its discrete form – the factor in this case becomes 1/Q 2 (or d 2 ). Discussion is also presented with respect to practical data reduction where a vanadium measurement is usually taken as the normalization factor (to account for various factors such as detector efficiency), and it is shown that the existence of the Lorentz factor is independent of such a normalization process.

36 MATERIALS SCIENCE↗