Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NEET In-Pile Ultrasonic Sensor Enablement-FY-2013

Several programs funded by the Department of Energy Office of Nuclear Energy (DOE-NE), such as the Fuel Cycle Research and Development, Advanced Reactor Concepts, Light Water Reactor Sustainability, and Next Generation Nuclear Plant programs, are investigating new fuels and materials for advanced and existing reactors. A key objective of such programs is to understand the performance of these fuels and materials when irradiated. The Nuclear Energy Enabling Technology (NEET) Advanced Sensors and Instrumentation (ASI) in-pile instrumentation development activities are focused upon addressing cross-cutting needs for DOE-NE irradiation testing by providing higher fidelity, real-time data, with increased accuracy and resolution from smaller, compact sensors that are less intrusive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric Research Measurement Climate Research Facility - Atmospheric System Research High-Resolution Modeling Workshop, May 19-20, 2014

The Atmospheric Radiation Measurement (ARM) Climate Research Facility is a scientific user facility within the U.S. Department of Energy (DOE) Climate and Environmental Sciences Division (CESD) of the Office of Biological and Environmental Research (BER). ARM is an observation facility whose purpose is to provide ground-based observations of the atmosphere to support climate research and to support the improvement of global climate models. ARM is closely affiliated with the Atmospheric System Research (ASR) program, which uses ARM data to address key atmospheric science issues and improve the parameterization of physical processes in climate models. A common methodology for using ARM data to improve climate models has been to carry out multi-model evaluation projects, typically in conjunction with field campaigns in which intensive radiosonde launches support the development of model forcing data sets. These exercises have yielded important insights. However, in recent years, there has been a growing interest in supporting high-resolution model simulations on a more routine basis. An important aspect of ARM sites is the continuous collection of high-resolution data over long periods of time. More routine model simulations would take better advantage of these long-term data sets. Nevertheless, accomplishing this will require careful attention to the requirements for running and evaluating these models together with a research program that maximizes the benefit of the model output.

54 ENVIRONMENTAL SCIENCES↗

ATDM/ECP Milestone Memo WBS 2.3.4.04 / SNL ATDM Data and Visualization Projects STDV04-21 - [MS1/YR2] Q3: Prototype Catalyst/ParaView in-situ viz for unsteady RV flow on ATS-1

ParaView Catalyst is an API for accessing the scalable visualization infrastructure of ParaView in an in-situ context. In-situ visualization allows simulation codes to access data post-processing operations while the simulation is running. In-situ techniques can reduce data post-processing time, allow computational steering, and increase the resolution and frequency of data output. For a simulation code to use ParaView Catalyst, adapter code needs to be created that interfaces the simulations data structures to ParaView/VTK data structures. Under ATDM, Catalyst is to be integrated with SPARC, a code used for simulation of unsteady reentry vehicle flow.

97 MATHEMATICS AND COMPUTING↗

AWAKEN - Site D - IWES Profiling Lidar / Raw Data

Fraunhofer IWES's profiling lidar (Windcube v2.0) raw data at AWAKEN site D. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

AWAKEN Site A1 - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at AWAKEN site A1. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

AWAKEN Site A2 Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from the profiling lidar (Windcube v2.1) at AWAKEN site A2. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at the WFIP3 BARG site. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution. Note: these data have NOT been corrected for the motion of the barge.

17 WIND ENERGY↗

WFIP3 - BARG site - NREL Profiling Lidar (Windcube v2.1) / Raw Data

This dataset contains raw data from NREL's profiling lidar (Windcube v2.1) at the WFIP3 NOAA SHIP site. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real time data, at about 1 Hz resolution.

17 WIND ENERGY↗

FC Site 4.0 - NLR Profiling Lidar (Windcube v2.1) / Raw data

The dataset contains raw data from the ground-based NLR profiling lidar (Windcube v2.1) at FC Site 4.0. Two data types are included here: 1) STA files, which have 10-minute average data, and 2) RTD files, which have real-time data, at about 1 Hz resolution.

17 WIND ENERGY↗

Sizing Accuracy of Low-Cost Optical Particle Sensors Under Controlled Laboratory Conditions

Low-cost particulate matter sensors have seen increased use for monitoring at personal and local levels due to their affordability, ease of operation, and high time resolution. However, the quality of data reported by these sensors can be questionable, and a thorough evaluation of their performance is necessary. This study evaluated the particle sizing accuracy of several commonly used optical sensors, including the Alphasense optical particle counter (OPC), TSI DustTrak DRX aerosol monitor, Plantower PMS5003 sensor, and Sensirion SPS30 sensor, using laboratory-generated monodisperse particles. The OPC and DRX agreed partially with reference instruments and showed promise in detecting coarse-size particles. However, the PMS5003 and SPS30 did not correctly size fine and coarse particles. Furthermore, their reported mass distributions do not directly correspond to their number distribution. Despite these limitations, field measurements involving a dust storm period showed that the SPS30 correlated reasonably well with reference instruments for both PM2.5 and PM10, though the regression slopes differed significantly. These findings underscore the need for caution when interpreting data from low-cost optical sensors, particularly for coarse particles. Recommendations for improving the performance of these sensors are also provided.

Gautam, Prakash↗

Plasma potential mapping of high power impulse magnetron sputtering discharges

Pulsed emissive probe techniques have been used to determine the plasma potential distribution of high power impulse magnetron sputtering (HiPIMS) discharges. An unbalanced magnetron with a niobium target in argon was investigated for pulse length of 100 μs at a pulse repetition rate of 100 Hz, giving a peak current of 170 A. The probe data were taken with a time resolution of 20 ns and a spatial resolution of 1 mm. It is shown that the local plasma potential varies greatly in space and time. The lowest potential was found over the target’s racetrack, gradually reaching anode potential (ground) several centimeters away from the target. The magnetic pre-sheath exhibits a funnel-shaped plasma potential resulting in an electric field which accelerates ions toward the racetrack. In certain regions and times, the potential exhibits weak local maxima which allow for ion acceleration to the substrate. Knowledge of the local E and static B fields lets us derive the electrons’ E×B drift velocity, which is about 105 m/s and shows structures in space and time.

36 MATERIALS SCIENCE↗

Positron-emission tomography detector systems based on low-density liquid scintillators and precise time-resolving photodetectors

TOF-PET detector systems, and methods for imaging photon-emitting samples using the detector systems, are provided. The TOF-PET detector systems use large-area photodetectors with extremely high time-resolution and an approach to data collection and analysis that allows for the use of inexpensive low-density scintillator materials. The TOF-PET detector systems are characterized by their ability to identify, on a statistical basis, the transverse and depth location of the first of the series of energy deposition events that are generated when a gamma photon enters the low-density scintillator material.

Frisch, Henry J.↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

A fast-time-response extreme ultraviolet spectrometer for measurement of impurity line emissions in the Experimental Advanced Superconducting Tokamak

A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm{sup 2} and pixel numbers of 1024 × 255 (26 × 26 μm{sup 2}/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ{sub 0} = 3-4 pixels, where Δλ{sub 0} is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗