Search NASA⌕ Search

SEARCH · Search NASA

Results for “total dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

FY2020 Savannah River Site Composite Analysis Annual Summary Review

This document provides the Department of Energy (DOE) Order 435.1 and its manual, Radioactive Waste Management (DOE 2021a, 2021b) required Annual Review for the Savannah River Site (SRS) Composite Analysis (CA). Progress made to-date toward addressing the secondary issue from the LFRG review of the 2010 SRS CA has focused primarily upon inventory estimate improvements. Inventory impacts dose in a linear fashion and reduces the uncertainty with the CA conclusions. Maintenance items are addressed, as funding allows, based on the relative risk associated with meeting the performance objectives. Currently, there is minimal risk in exceeding the DOE 100 mrem/yr CA primary dose limit or the DOE 30 mrem/yr dose constraint (administrative limit). Proposed activities, discoveries, new information and changes potentially affecting the 2010 SRS CA are documented in this and earlier Annual Summary reports, and a consolidated list of changes since the 2010 CA is documented in this report. The impact to the CA of changes arising from updated performance assessment (PA) baselines [i.e., Saltstone Disposal Facility (SDF), E-Area Low-Level Waste Facility (ELLWF), and F & H Tank Farm (FTF & HTF) closures] is expected to be minor for the following reasons: The primary contributors to the SRS CA dose impact at the Upper Three Runs (UTR) point of assessment (POA) are the H-Canyon and Mixed Waste Management Facility (MWMF), contributing 68% and 9%, respectively, to the dose impact at that POA. The combined contribution to the UTR dose impact from all PA’s (SDF, ELLWF, FTF and HTF) is ~2% of this total. The 2010 SRS CA model validation performed indicates that the CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. Doses evaluated are well below the SRS established 15 mrem/yr administrative limit (Crapse et al. 2011). Based on the assessment presented within this annual review and collective engineering judgement, the conclusions of the 2010 SRS CA remain valid and there is reasonable assurance that SRS will meet the performance objectives delineated in DOE Manual 435.1-1. The 2010 SRS CA should be updated to incorporate PA changes, proposed changes to inventories and sources and model improvements accumulated since the 2010 CA. The timing will be dependent on the completion of the ongoing E-Area PA revision.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation effects on atherosclerosis in atomic bomb survivors: a cross-sectional study using structural equation modeling

Past reports indicated that total-body irradiation at low to moderate doses could be responsible for cardiovascular disease risks, but the mechanism remains unclear. The purpose of this study was to investigate the association between radiation exposure and atherosclerosis, an underlying pathology of cardiovascular diseases, in the Japanese atomic bomb survivors. We performed a cross-sectional study measuring 14 clinical-physiological atherosclerosis indicators during clinical exams from 2010 to 2014 in 3274 participants of the Adult Health Study cohort. Multivariable analyses were performed by using a structural equation model with latent factors representing underlying atherosclerotic pathologies: (1) arterial stiffness, (2) calcification, and (3) plaque as measured with indicators chosen a priori on the basis of clinical-physiological knowledge. Radiation was linearly associated with calcification (standardized coefficient per Gy 0.15, 95 % confidence interval: CI [0.070, 0.23]) and plaque (0.11, 95 % CI [0.029, 0.20]), small associations that were comparable to about 2 years of aging per Gy of radiation exposure, but not with arterial stiffness (0.036, 95 % CI [-0.025, 0.095]). The model fitted better and had narrower confidence intervals than separate ordinary regression models explaining individual indicators independently. The associations were less evident when the dose range was restricted to a maximum of 2 or 1 Gy. By combining individual clinical-physiological indicators that are correlated because of common, underlying atherosclerotic pathologies, we found a small, but significant association of radiation with atherosclerosis.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Dose Rate Analysis of the WCS Consolidated Interim Storage Facility

This report describes a confirmatory calculation for a proposed consolidated interim storage facility (CISF) to support the US Nuclear Regulatory Commission’s review of the license application submitted by the Interim Storage Partners. The scope of this report is limited to an assessment of the annual dose from direct radiation associated with Phase 1 of the Waste Control Specialists (WCS) CISF and the determination of the minimum controlled area boundary based on the 10 CFR 72.104 limit of 25 mrem annual dose to the whole body. The confirmatory dose rate calculations used the source term and shielding calculation capabilities of the SCALE 6.2.3 computer code system. The calculation method employed in the confirmatory calculations uses a detailed Monte Carlo radiation transport simulation from source to dose rate. This method differs from the two-step method used in the safety analysis report (SAR), which requires determination of the photon and neutron energy and angular distributions on the cask external surface and then the use of this surface source in a new radiation transport calculation to determine dose rate as a function of distance from the storage facility. A simulation was made using the complete site geometry (all casks present) but with only one cask containing source, and a total of 467 independent calculations were performed to obtain the dose rate maps produced by each storage cask. Basic input data and assumptions used in the SAR (e.g., cask design parameters and design basis assembly characteristics) were used in this confirmatory calculation for consistency with the SAR. Local atmospheric conditions for skyshine calculations were simulated using US standard atmosphere data, which describe average air temperature, pressure, and density as a function of altitude. The determined minimum required distances from the WCS Phase 1 CISF to a contour defined by the 25 mrem annual dose limit were approximately 623 m (0.387 miles) in the N-NE direction, 594 m (0.369 miles) in the SSW direction, and 533 m (0.331 miles) in the E-SE direction and the W-NW direction. The annual dose results of the confirmatory calculation are in relatively good agreement with the annual dose values presented in the WCS SAR. The annual dose produced by the Phase 1 CISF at the nearest site boundary, 0.75 miles away from the CISF, was estimated by this study to be approximately 6.02E-02 ± 2.0E-04 mrem, which is significantly smaller than the 25 mrem annual dose limit provided in 10 CFR 72.104. The SAR annual dose rate value for the nearest site boundary was 7.52E-2 mrem, which included 7.73E-03 mrem due to postulated leakage of the FO-, FC-, and FF-canisters. A comparison with the dose rate values reported in the SAR for 16 detector locations, D1 through D16, on the protected area boundary is also included in this report. This comparison shows that the SAR determined higher annual dose values for detectors D1 through D14 by 12% to 45% and lower annual dose values for detectors D15 and D16 by 18% and 8%, respectively, as compared with this ORNL confirmatory calculation. Sensitivity studies have been performed to support a comprehensive review of the application. In these studies, the effects on dose rate of the modeled air volume, density, and humidity were analyzed. The sensitivity calculations showed that the air volume used in the Monte Carlo simulations was adequate and that a larger air volume would not further increase the dose rate due to skyshine contributions. The sensitivity analysis showed that simulation of local atmospheric conditions is important for the accuracy of dose rate estimates at large distances from the facility. Air humidity was demonstrated to have negligible effects on dose rate values for the simulated local atmospheric conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Grain Size on Performance Degradation of TREAT LEU

We argue that radiation damage induced degradation of thermal conductivity does not set a lower limit on fuel grain sizes for the low enriched uranium fuel design of the Transient Reactor Test Facility (TREAT). Earlier work reports that smaller grains cause a larger degradation of thermal conductivity than larger grains constraining the smallest feasible size of fuel grains. This work assesses TREAT’s transient performance in the presence of radiation damage. The difference between the two studies is in treating damaged and fresh graphite as serial (this work) or parallel (previous) heat resistors. We use a multiphysics model of TREAT fuel grains to compute the reduction in transient capability measured by the total deposited energy as a function of irradiation dose. We find that radiation damage has a negligible effect on energy deposition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Zika virus dynamics: Effects of inoculum dose, the innate immune response and viral interference

Experimental Zika virus infection in non-human primates results in acute viral load dynamics that can be well-described by mathematical models. The inoculum dose that would be received in a natural infection setting is likely lower than the experimental infections and how this difference affects the viral dynamics and immune response is unclear. Here we study a dataset of experimental infection of non-human primates with a range of doses of Zika virus. We develop new models of infection incorporating both an innate immune response and viral interference with that response. We find that such a model explains the data better than models with no interaction between virus and the immune response. We also find that larger inoculum doses lead to faster dynamics of infection, but approximately the same total amount of viral production.

59 BASIC BIOLOGICAL SCIENCES↗

NSUF RTE completion report for 23-4780: Microstructural Defect Induced Thermal Conductivity Reduction in Uranium Nitride and Thorium Nitride

Uranium nitride (UN) is known to have a higher thermal conductivity than traditional oxide fuels, which could lead to a more efficient energy transport and lower local temperature during its lifetime. But the thermal transport performance of UN in extreme environments has not been systematic studied. This study investigated the irradiation induced microstructural defects in UN and the impacts on thermal conductivity. The samples were produced by spark plasma sintering at University of Texas-San Antonio (UTSA), Los Alamos National Laboratory (LANL), and Idaho National Laboratory (INL). Thermal conductivity of UN before and after 2MeV proton irradiation were measured by using laser metrology at INL in a temperature range of 77-295K. Thermal conductivity measurements in this wide, cryogenic temperature range is critical to understand the phonon scattering mechanisms between the thermal energy carrier, phonons, and different types of irradiation-induced defects. In order to ensure the measurements were conducted in the same grains and minimize the impact of the local heterogeneities, the measurement locations were highlighted by fiducial marks using the focused ion beam (FIB) with grain orientation identified using the electron backscatter diffraction (EBSD) at the Center of Advanced Energy Studies (CAES). Irradiation experiment was conducted at the Ion Beam Laboratory at Texas A&M University (TAMU). A total of 6 samples were irradiated with different irradiation doses and temperatures. After irradiation, the microstructure was characterized by using Transmission Electron Microscope (TEM) at CAES (also in the FIB marks).

36 - MATERIALS SCIENCE↗

Effects of dose rate on the microstructure and deuterium retention in γ-LiAlO 2 pellets

This report presents experimental findings obtained from November 2024 to September 2025. Defect accumulation and microstructural evolution during ion irradiation at elevated temperatures are governed by two competing processes: defect production, driven by dose rate, and defect recovery, controlled by defect diffusion, interaction, and annihilation. At a given dose, the resulting microstructural evolution depends on both the dose rate and irradiation temperature. As a continuation of our FY24 tritium science project, which investigated temperature effects at a fixed dose rate, this study focuses on dose-rate effects at a fixed temperature to provide deeper insights into the irradiated microstructure and compositional changes in γ-LiAlO 2 pellets. The study aims to elucidate the impact of dose rate on microstructure, precipitate morphology, deuterium retention, and lithium volatility in γ-LiAlO 2 pellets under sequential 120 keV He + and 80 keV D 2 + ion irradiation. Three dose rates of 7.3×10 4 , 2.9×10 4 and 6.8×10 5 dpa/s were applied to achieve the same total ion fluence of 2×10 17 (He + +D + )/cm 2 at 500 °C, corresponding to a maximum combined dose of 7.55 dpa at ~255 nm. The irradiated pellets were subsequently characterized using scanning transmission electron microscopy (STEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The microstructural response of γ-LiAlO 2 to ion irradiation was found to be strongly dose-rate dependent. At medium and high dose rates, irradiation produced a surface amorphized layer and an underlying crystalline layer containing LiAl 5 O 8 precipitates, with implanted gases accumulating and forming blisters at the crystalline-amorphous interface. It remains to be investigated whether the amorphized layer was produced by He + ion irradiation prior to D 2 + ion irradiation. In contrast, at low dose rates, the material remained crystalline, with cavities, likely gas-filled, distributed around precipitates, within the γ-LiAlO 2 matrix, and along grain boundaries. While precipitate morphology exhibited anisotropy, their size showed little sensitivity to dose rate in the applied range of this study. This result, however, does not rule out the possibility that further reductions in dose rate could influence precipitate size. High dose-rate irradiation enhanced protonium–deuterium isotopic exchange and lithium depletion in the amorphized region. Collectively, the results show that dose rate governs amorphization, gas redistribution, isotopic exchange, and lithium depletion, providing important insights into the mechanisms underlying structural evolution in γ-LiAlO 2 pellets under reactor-relevant irradiation conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Long-term, non-invasive FTIR detection of low-dose ionizing radiation exposure

Non-invasive methods of detecting radiation exposure show promise to improve upon current approaches to biological dosimetry in ease, speed, and accuracy. Here we developed a pipeline that employs Fourier transform infrared (FTIR) spectroscopy in the mid-infrared spectrum to identify a signature of low dose ionizing radiation exposure in mouse ear pinnae over time. Mice exposed to 0.1 to 2 Gy total body irradiation were repeatedly measured by FTIR at the stratum corneum of the ear pinnae. We found significant discriminative power for all doses and time-points out to 90 days after exposure. Classification accuracy was maximized when testing 14 days after exposure (specificity > 0.9 with a sensitivity threshold of 0.9) and dropped by roughly 30% sensitivity at 90 days. Infrared frequencies point towards biological changes in DNA conformation, lipid oxidation and accumulation and shifts in protein secondary structure. Since only hundreds of samples were used to learn the highly discriminative signature, developing human-relevant diagnostic capabilities is likely feasible and this non-invasive procedure points toward rapid, non-invasive, and reagent-free biodosimetry applications at population scales.

61 RADIATION PROTECTION AND DOSIMETRY↗

The influence of nitrogen and nitrides on the structure and properties of proton irradiated ferritic/martensitic steel

The 12Cr1MoWV (wt%) ferritic/martensitic steel HT9 is a candidate material for fuel cladding in advanced nuclear reactors, such as the Versatile Test Reactor currently under development. As such, understanding the relationship between microstructure and mechanical properties in the context of irradiation environments for these steels is critical. N content, and more specifically interstitial N, has been hypothesized to be detrimental to irradiated properties at lower temperatures (less than 0.3T m ) to a total of 6 dpa; however, in this work at a dose of 1 dpa the irradiated microstructure was improved with added N, leading to less irradiation hardening. Three variants of HT9 were irradiated with 1.5 MeV protons to a dose of 1 dpa at 300°C. The HT9 variants included Low (10 ppm), Mid (190 ppm), and High (440 ppm) N alloys that were otherwise nearly identical. Changing the N content had a variety of effects on the irradiated defect structures. As N content increased, the average dislocation loop diameter decreased, while the number density of loops increased. Additionally, extensive Ni clustering was observed on dislocations and interfaces. The Mid and High N specimens exhibited significantly less hardening (ΔHV≃100) relative to the Low N specimen (ΔHV≃160). The decrease in hardening is attributed to vanadium carbonitride acting as a sink for Ni clusters that would otherwise form on dislocations. Under the irradiation conditions used, these results suggest increasing the N content in HT9 may have a desirable effect on the irradiated structure and properties at the dose studied, as well as the swelling resistance at higher doses. In other words, N content appears to be a powerful tool for tailoring the self-interstitial atom cluster mobility in F/M steels for different temperature and dose applications.

36 MATERIALS SCIENCE↗

WSF B696R Calcs

This calculation is applied to the accident analysis scenario of a limited combustibles fire breaching eight SWBs in B696R R1010. For a fire in a building with no breaches, there is only a ground release. The source term (ST) of the deflagration is determined by the Waste Storage Facilities Documented Safety Analysis (Ref. 1). The doses from the release are calculated by using MACCS2 (Ref. 2). This software take hourly meteorological data for a year as input. There are 8760 hours in a year. MACCS2 calculates a dose for each of the 8760 hours, taking into account the associated source term from Reference 1, the wind speed, the stability class (i.e., A through F), the directional sector of the wind (with associated distance to the site boundary). For each directional sector (i.e., 1 through 16) a MACCS2 run was performed. From the total collection of MACCS2 output files, Microsoft Excel is used to extract the dose that correspond to the meteorological conditions of each hour in the year. Note: although MACCS2 inputs a single year of meteorological data, five years are used (2010 through 2014) by performing multiple runs. This is discussed in Section 2.2. Conclusions: The final 95th percentile dose at the collocated worker used for accident analysis of a limited combustibles fire breaching eight SWBs in B696R R1010 is 18.4 rem.

99 GENERAL AND MISCELLANEOUS↗

Verification and Validation of START: A Spent Nuclear Fuel Routing and Decision Support Tool

The Stakeholder Tool for Assessing Radioactive Transportation (START) is a web-based geospatial decision-support tool being developed by the US Department of Energy’s Office of Integrated Waste Management (IWM) to support federal interim storage for spent nuclear fuel (SNF) and associated transportation. START provides many functions for the IWM program including: serving as a communications tool for conveying geospatial data and information, an options analysis tool for exploring potential transport modes and routes for transporting SNF from nuclear power plants to future federal interim storage facilities, an emergency response planning tool for Tribes and States to identify training needs along potential SNF transport corridors, an environmental analysis tool for estimating potential radiation dose exposure from incident-free and incident-case SNF transport conditions, and a systems analysis support tool providing route-related inputs for system throughput analysis. As part of the START development process, a verification and validation (V&V) effort is being undertaken. In the initial V&V phase, several outputs of the START tool were checked such as the total distance, population and population densities within the buffer zone, and incident free dose. The V&V process is fluid as it will be utilized after each version change to ensure that the core functionalities of the tool are maintained and the results are consistent with the previous versions. Efforts have also been put into developing scripts to aid in the process of automating certain sections of the V&V work. As some of the V&V efforts use Environmental Systems Research Institute’s (ESRI) tools upon which the START framework is built, the START data were compared against outputs from tools like Quantum Geographic Information System (QGIS) for buffer zone populations and route lengths to ensure independence of the V&V process. Good agreement was observed between the START results and the independent V&V studies with the majority of the differences falling between 1% and 5% for populations within the buffer zone and route distance. This presentation describes the development and design of the START tool, V&V methods employed for various metrics of interest and their respective results, and future plans.

START, transportation, GIS, V&V↗

Revealing the synergistic effects of sequential and simultaneous dual beam irradiations in tungsten via in-situ TEM

Elucidating the synergistic effects of different energetic beams on the radiation response of nuclear materials is critical for developing an improved methodology for their evaluation when exposed to extreme environments. This article describes in-situ sequential (He implantation followed by Kr irradiation and vice-versa) and simultaneous (heavy ion Kr irradiation and He implantation) dual beam irradiations performed on tungsten at 1223 K. Dislocation loop density, average area, and total loop damage as a function of irradiation history and dose/fluence are quantified. The loop Burgers vectors and cavity damage (cavity density, size and total change in volume) are also determined at the final maximum dose for each condition. The loop damage evolution was different in all cases, with the smallest loop damage observed in the simultaneous experiment. Annihilation of Kr generated dislocation loops during He implantation in the Kr + He experiment was an unanticipated observation that may be explained by the dynamic evolution of dislocation loop sink strengths and time-dependent defect fluxes. Dislocation loop raft formation, denuded zones near extended defects, and cavity damage are compared across the different conditions. The phenomena observed and discussed in this work will stimulate further experimental and computational modeling activities leading to improved fundamental understanding of the irradiation response of nuclear materials under reactor-similar environments.

36 MATERIALS SCIENCE↗

Irradiated stainless steel 347 and irradiated, welded, and hydrogen charged Zircaloy-4 property data for the target solution vessel and support lines of SHINE

In support of the reactor-vessel development effort of SHINE medical technologies, irradiation of its structural materials and post-irradiation testing have been performed in the High Flux Isotope Reactor at Oak Ridge National Laboratory. This irradiation was performed on welded and unwelded AISI 347 steel and Zircaloy-4 samples at low temperature (~60°C) in contact with the reactor coolant. Hardness, Charpy, and tensile data have been taken from all cases of unirradiated specimens, while post-irradiation tensile and hardness data have been taken from AISI 347 base metal and Zircaloy-4 base metal and weld specimens so far. Additionally, 3-point bend data have been taken from explosion-welded specimens. The expected changes to hardness, yield strength, ultimate tensile strength, uniform elongation, and total elongation as a result of the low temperature and low dose neutron irradiation are reported here.

36 MATERIALS SCIENCE↗

Modeling of ATR fuel in DOE Standard Canisters with Helium Backfilled Condition

Road-ready and final disposition packaging configurations for the advanced test reactor (ATR) fuel dictates storage within helium backfilled sealed DOE standard canisters. These sealed canisters are intended for extened (>50 year) dry storage). The typical packaging configuration for the 15-foot DOE canisters places 10 ATR elements within a Type 1a basket, and three baskets are loaded within each DOE canister. During in-reactor operations and cooling pond storage conditions, oxyhydroxide layers form on the surface of the aluminum clad fuel. These layers produce hydrogen gas over time due to the fuel’s radiation field. As part of the packing procedure, the ATR fuel should be dried to remove any residual physio-/chemi- sorbed water from the surface. As testing to the effectiveness of the drying procedure is still underway, this modeling will include results at fully saturated and fully dried conditions. In previous modeling efforts, the G-value for the production of hydrogen from the oxyhydroxide layers was assumed to be in argon environments as measured by Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution. Previous experimental testing showed differences in the hydrogen generated based on the gaseous environment. In the associated experimental work, Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution, additional tests were completed in a helium environment, and updated G-values for the radiolytic production of hydrogen from the oxyhydroxide layers were provided. These values are 28% and 58% higher than values for argon. In addition, a change to the modeling of the oxyhydroxide radiolysis has been made from previous reports. This change assumes the dependency of the dose rate on the overall reaction rate is applied to the total weight of the sample, rather than to just the weight of the oxyhydroxide layer. This decreases the dependency of the radiolytic reaction on the thickness of the oxyhydroxide layer. For a nominal scenario of stored ATR fuel, assuming the chemi-/physio- sorbed water have been fully removed, the internal canister pressure increases to 1.61 atm over a 50 year period, with a hydrogen mole percentage of 21%. As in previous modeling, any oxygen present is in negligible amounts (<1 ppt). If a small amount residual air is present, nitric acid can form up to 1300 ppm. For a scenario with high fuel decay heat, the model shows internal pressure increasing to 2.1 atm, with 39.3 mole percentage of hydrogen. In a scenario where significant chemi-/physio- sorbed water is present within the corrosion layer, the nominal scenario shows a pressure increase to 2.54 atm, with 21.1 mole percent hydrogen. The high decay heat case shows a pressure increase to 3.18 atm with 39.9 mole percent hydrogen.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of HZ-PAN Sorbent Irradiation on Kr Adsorption

Idaho National Laboratory (INL) has developed and studied an engineered form hydrogen mordenite in polyacrylonitrile matrix (HZ-PAN) for krypton (Kr) adsorption. Adsorption studies to date have successfully separated and captured Kr from carrier gas streams, but those studies have used non-radioactive gases for testing. However, if utilized in a used nuclear fuel (UNF) reprocessing facility, this sorbent will be exposed to the potential deleterious effects of radiation. This report explores Kr adsorption behavior on HZ PAN after the sorbent was exposed to gamma radiation. A batch of HZ-PAN was divided into five segments, a control segment that was not exposed to radiation, and the other four segments that were exposed to progressively increased levels of radiation dose, up to 5 MGy. Samples were then analyzed to determine total surface area as well as their capacity to capture Kr. This study reveals HZ PAN retains its initial surface area and Kr-capture capacity after radiation exposure, indicating viability for service in radioactive gases.

42 - ENGINEERING↗

Within and Among Fish Species Differences in Simulated Turbine Blade Strike Mortality: Limits on the Use of Surrogacy for Untested Species

Use of surrogacy remains a useful method for prioritizing research on representatives of at-risk groups of fishes, yet quantifiable evidence in support of its use is generally not available. Blade strike impact represents one of the most traumatic stressors experienced by fish during non-volitional movements through hydropower turbines. Here, we use data generated from laboratory trials on blade strike impact experiments to directly test use of surrogacy for salmonid and clupeid fishes. Results of logistic regression indicated that a -taxonomic (genus) variable was not a significant predictor of mortality among large rainbow trout and brook trout. Similar results were found for young-of-the-year shad species, but genus-level taxonomy was a significant predictor of mortality while species was not. Multivariate analysis of morphometric data showed that shad clustered together based on similarities in fish shape which was also closely associated with genus. Logistic regression including size as a major covariate suggested total fish length was not a significant predictor of mortality, yet dose–response data suggest differential susceptibility to lower strike velocities. We suggest that use of surrogacy among species is justifiable but should be avoided within a species since the effects of size remain unclear.

59 BASIC BIOLOGICAL SCIENCES↗

Dietary B group vitamin intake and the bladder cancer risk: a pooled analysis of prospective cohort studies

Abstract Purpose Diet may play an essential role in the aetiology of bladder cancer (BC). The B group complex vitamins involve diverse biological functions that could be influential in cancer prevention. The aim of the present study was to investigate the association between various components of the B group vitamin complex and BC risk. Methods Dietary data were pooled from four cohort studies. Food item intake was converted to daily intakes of B group vitamins and pooled multivariate hazard ratios (HRs), with corresponding 95% confidence intervals (CIs), were obtained using Cox-regression models. Dose–response relationships were examined using a nonparametric test for trend. Results In total, 2915 BC cases and 530,012 non-cases were included in the analyses. The present study showed an increased BC risk for moderate intake of vitamin B1 (HR B1 : 1.13, 95% CI: 1.00–1.20). In men, moderate intake of the vitamins B1, B2, energy-related vitamins and high intake of vitamin B1 were associated with an increased BC risk (HR (95% CI): 1.13 (1.02–1.26), 1.14 (1.02–1.26), 1.13 (1.02–1.26; 1.13 (1.02–1.26), respectively). In women, high intake of all vitamins and vitamin combinations, except for the entire complex, showed an inverse association (HR (95% CI): 0.80 (0.67–0.97), 0.83 (0.70–1.00); 0.77 (0.63–0.93), 0.73 (0.61–0.88), 0.82 (0.68–0.99), 0.79 (0.66–0.95), 0.80 (0.66–0.96), 0.74 (0.62–0.89), 0.76 (0.63–0.92), respectively). Dose–response analyses showed an increased BC risk for higher intake of vitamin B1 and B12. Conclusion Our findings highlight the importance of future research on the food sources of B group vitamins in the context of the overall and sex-stratified diet.

60 APPLIED LIFE SCIENCES↗