Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow

Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center-line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30-deg inclination angle.

Wang, C. R.↗

Theoretical analysis of total-pressure loss and airflow distribution for tubular turbojet combustors with constant annulus and liner cross-sectional areas

Compressible and incompressible flow calculations were made of the combustor total-pressure-loss coefficient and liner airflow distribution for tubular turbojet combustors having constant annulus and liner cross-sectional areas along the combustor axis. Information on static and total pressure distribution and liner air-jet entrance angles along the length of the combustor was obtained as an intermediate step in the calculations. The calculations include the effects of heat release, annulus wall friction, and variation in discharge coefficients of the liner wall openings along the combustor. The combustor total-pressure-loss coefficient and liner air-flow distribution are presented graphically in terms of the following dimensionless parameters: (1) combustor reference Mach number, (2) ratio of combustor-exit to inlet total temperature, (3) fraction of total airflow passing through the liner dome, (4) ratio of total open hole area in liner wall to total combustor cross-sectional area, and (5) ratio of liner cross-sectional area to total combustor cross-sectional area.

Graves, Charles C↗

Method to Measure Total Noise Temperature of a Wireless Receiver During Operation

An electromagnetic signal receiver and methods for determining the noise level and signal power in a signal of interest while the receiver is operating. In some embodiments, the signal of interest is a GPS signal. The receiver includes a noise source that provides a noise signal of known power during intervals while the signal of interest is observed. By measuring a signal-to-noise ratio for the signal of interest and the noise power in the signal of interest, the noise level and signal power of the signal of interest can be computed. Various methods of making the measurements and computing the power of the signal of interest are described. Applications of the system and method are described.

Young, Lawrence E.↗

Effect of steady-state temperature distortion and combined distortion on inlet flow to a turbofan engine

Flow angle, static pressure, total temperature and total pressure were measured in the inlet duct upstream of a turbofan engine operating with temperature distortion or combined pressure-temperature distortion. Such measurements are useful in the evaluation of analytical models of inlet distortion. A rotating gaseous-hydrogen burner and a circumferential 180 degrees-extent screen configuration mounted on a rotatable assembly generated the distortions. Reynolds number index was maintained at 0.5 and engine corrected low-rotor speeds were held at 6000 and 8600 rpm. The measurements showed that at the entrance to the engine, flow angle was largest in the hub region. As flow approached the engine, yaw angle (circumferential variation) increased and pitch angle (radial variation) decreased. The magnitude of static-pressure distortion measured along the inlet-duct and extended bullet nose walls increased exponentially as flow approached the engine.

Soeder, R. H.↗

An analysis of data related to the minimum temperatures for valid testing in cryogenic wind tunnels using nitrogen as the test gas

The minimum operating temperature which avoids adverse low temperature effects, such as condensation, has been determined at a free stream Mach number of 0.85 for flow over a 0.137 meter airfoil mounted at zero incidence in the Langley 1/3 meter transonic cryogenic tunnel. The onset of low temperature effects is established by comparing the pressure coefficient measured at a given orifice for a particular temperature with those measured at temperatures sufficiently above where low temperature effects might be expected to occur. The pressure distributions over the airfoil are presented in tabular form. In addition, the comparisons of the pressure coefficient as a function of total temperature are presented graphically for chord locations of 0, 25, 50, and 75 percent. Over the 1.2 to 4.5 atmosphere total pressure range investigated, low temperature effects are not detected until total temperatures are 2 K, or more, below free stream saturation temperatures.

Hall, R. M.↗

A probe for measuring temperature and pressure at the same points in a gas stream

Design features and characteristics of a means for measuring total temperature and total pressure at a single point in a gas stream are presented. A rake that provides five such combination measurements is described. Experimental data are included for the aerodynamic recovery and time response of the temperature sensor and for the flow-angle sensitivity of both the temperature and pressure sensors. Data were obtained over a subsonic Mach number range of 0.3 to 0.9 as well as at a Mach number of 1.4.

Krause, L. N.↗

An experimental study of surface curvature effects on a supersonic turbulent boundary layer

The mean flow results of an experimental study of compressible turbulent boundary layers in an adverse pressure gradient with and without surface curvature effects are presented. The test was conducted in an axisymmetric flow facility. The upstream Reynolds number based on boundary layer momentum thickness was 5884 and the boundary layer thickness was 0.90 cm. The curvature effects were examined by studying two flows with essentially identical adverse pressure gradients. One flow was along a concave compression surface test section, while the other was along a straight-walled test section. Mean flow measurements included wall static pressure distributions, wall temperatures, pitot pressure profiles and total temperature profiles. The mean flow results indicated that the surface curvature resulted in a definite increase of turbulent mixing in the boundary layer.

Chou, J. H.↗

Numerical Investigation of Heat Transfer on the NASA SIDRM Model

NASA has developed a Simulated Inter-Duct Research Model (SIDRM) to study ice crystal icing in aircraft engines. A numerical investigation has been completed using the NASA in-house code, GlennHT. For each flow condition, many different wall thermal boundary conditions were imposed. Six uniform wall temperature cases were generated, with wall temperature relative to the freestream total temperature of 0.85, 0.90, 0.95, 1.05, 1.10, and 1.15. In addition, five cases with uniform heat flux were generated. Heat fluxes were chosen to generate average wall temperatures in the range explored by the uniform wall temperature cases. Included in the uniform heat flux cases is the adiabatic case where heat flux equals zero. The results of these simulations are then used to quantify the degree to which the heat transfer coefficient depends on wall thermal boundary condition. It is seen that the heat transfer coefficient is fairly independent of wall thermal boundary condition, as expected. However, it would appear that, at least in some locations, it may be prudent to attempt to correlate a variation of heat transfer coefficient with wall thermal boundary condition.

Ice Crystal Icing↗

Effects of Casting Parameters and Impurity Concentrations on As-Cast U–10Mo

This work investigates the effects of casting parameter changes on as-cast uranium-10 wt% molybdenum alloys on a 1-2kg scale. A commercial tilt-pour vacuum induction melting system was utilized to study the effects of casting atmosphere, total heating time, hold time at maximum temperature, mold temperature, and crucible type on the as-cast microstructure of U-10Mo. Ten thin plates (5.08 mm thick) and four thick plates (25.4 mm and 63.5 mm thick) were cast and analyzed for carbon, oxygen, hydrogen, and nitrogen impurities. Additionally, molybdenum content and primary dendrite length (PDL) of the microstructure was quantified. A statistical evaluation was performed to identify key carbon and oxygen relationships with operating parameters, impurities, and primary dendrite length. Additional factors investigated include: crucible material, time at maximum temperature, total heating time, and pour temperature. Zirconia crucibles reduced carbon content on average by 35%. Additionally, there was a significant statistical association between carbon and oxygen content, between oxygen content and maximum temperature hold time, between mold temperature and PDL, and between PDL, maximum temperature hold time and mold temperature.

Huber, Zachary F.↗

NASA Glenn 1-by 1-Foot Supersonic Wind Tunnel User Manual

This manual describes the NASA Glenn Research Center's 1 - by 1 -Foot Supersonic Wind Tunnel and provides information for customers who wish to conduct experiments in this facility. Tunnel performance envelopes of total pressure, total temperature, and dynamic pressure as a function of test section Mach number are presented. For each Mach number, maps are presented of Reynolds number per foot as a function of the total air temperature at the test section inlet for constant total air pressure at the inlet. General support systems-such as the service air, combustion air, altitude exhaust system, auxiliary bleed system, model hydraulic system, schlieren system, model pressure-sensitive paint, and laser sheet system are discussed. In addition, instrumentation and data processing, acquisition systems are described, pretest meeting formats and schedules are outlined, and customer responsibilities and personnel safety are addressed.

Seablom, Kirk D.↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test - Part 2 (Temperature and Humidity)

This paper provides a characterization of the temperature and humidity variations within icing cloud flows generated during the second Fundamental Ice Crystal Icing Physics test conducted in NASA’s Propulsion Systems Laboratory, in June of 2018. The tests were conducted at airflow velocities of 85, 135, and 185 m/s, a static pressure of 44.8 kPa, and a total temperature of 7.2 ⁰C. A custom rearward facing probe and commercial total air temperature probe were used to obtain temperature and humidity profiles of the icing cloud flow leaving the exit duct plane. Additional background humidity measurements were also obtained from a commercial total water content probe. The probes captured the changes in temperature and humidity that took place at the test section after the cloud was activated. As the main altitude airflow interacts with the icing cloud, their thermodynamic properties undergo substantial changes. Due to the particle nature of the icing cloud, the droplets and ice crystals tend to redistribute within the cloud as it propagates with the main flow. Data will be presented that shows how these factors affect the thermodynamic property distribution within the icing cloud. A discussion is given of the thermal balances in the icing cloud, between the evaporating spray droplets and the airflow, as a basis for interpreting the measured results.

Crystal Icing↗

Investigation of a mixed compression axisymmetric inlet at Mach number 5.3

The hypersonic diffuser portion of an uncooled high performance mixed compression, axisymmetric inlet suitable for subsonic burning engines was designed and tested. Performance of a model with a 25.4-cm capture diameter was measured in a wind tunnel and the results were compared with theoretical predictions calculated by a comprehensive computer program. All tests were conducted at a Mach number of 5.3 at a total temperature of 667 K and a total pressure of 11.57 atm. The angle of attack ranged from 0 to + or - 3 deg. Performance at angle of attack remained high. Reasonably high performance in the throat (maximum throat pitot-pressure recovery of 77 percent and an average value of 58 percent) was obtained at 0 deg angle of attack with relatively large amounts of boundary-layer bleed (11 to 22 percent of the capture mass flow). The computer program used in the design of this inlet is considered marginally adequate for predicting hypersonic inlet flow fields. Although the program as it now exists is very useful, an improved computer program that more accurately predicts the boundary layer and the shock-wave-boundary-layer interaction and accounts for boundary-layer bleed should be developed for reliability predicting hypersonic inlet flow fields.

Latham, E. A.↗

Wind tunnel tests of space shuttle solid rocket booster insulation material in the aerothermal tunnel c

Wind tunnel tests of the space shuttle Solid Rocket Booster Insulation were conducted in the von Karman Gas Dynamics Facility Tunnel C. For these tests, Tunnel C was run at Mach 4 with a total temperature of 1100-1440 and a total pressure of 100 psia. Cold wall heating rates were changed by varying the test article support wedge angle. Selected results are presented to illustrate the test techniques and typical data obtained.

Hartman, A. S.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

The first experiment is a study of a coaxial jet discharging into stagnant laboratory air, with center jet of a mixture of 5% oxygen and 95% helium by volume and coflow jet of air. The exit flow pressure of both center-jet and coflow nozzles is 1 atmosphere. The presence of oxygen in the center jet is to allow the use of an oxygen flow-tagging technique (RELIEF4) to obtain non-intrusive velocity measurements. Both jets are nominally Mach 1.8, but, because of the greater speed of sound, the center jet velocity is more than twice that of the coflow. The mixing layer which forms between the center jet and the coflow near the nozzle exit is compressible, with a calculated convective Mach number of approximately 0.7. This geometry has several advantages: The streamwise development of the flow is generally dominated by turbulent stresses (rather than pressure forces), and thus calculations are sensitive to turbulence modeling. It includes features present in supersonic combustors, including a compressible mixing layer near the nozzle exit and a light-gas/air plume downstream. Since it is a free jet, it provides easy access for both optical instrumentation and probes. Since it is axisymmetric, it requires fewer experimental measurements to fully characterize, and calculations can be performed with more modest computer resources. However, weak shock waves formed at the nozzle exit strengthen and turn normal as they approach the axis, complicating the flow. Care is thus taken in the design of the facility to provide as near as possible to 1-D flow at the exit of both center and coflow nozzles, and to minimize the strength of waves generated at the nozzle exit. Results from this experiment are compared to CFD solutions obtained by VULCAN, a previously developed code used in engine analysis. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Thus, the geometry is relatively simple and large regions of subsonic recirculating flow are avoided. The nominal entrance Mach number is 2 and the enthalpy of the test gas (hot air "simulant") is nominally that of Mach 7 flight. It was believed, on the basis of calculations performed that this would produce mixing-limited flow, that is to say, one for which chemical reaction to equilibrium proceeds at a much greater rate than mixing. It later proved that this was not the case. The primary experimental technique employed is coherent anti-Stokes Raman spectroscopy, known by its acronym CARS. The species probed is molecular nitrogen and the quantity measured is temperature. Intrusive probes, such as Pitot, total temperature, hot-wire, etc., are not used due to access difficulty and high heat flux in the combustor, and because they may alter the flow. CARS has several advantages over other optical methods. It is a relatively mature and well-understood technique. Signal levels are relatively high and the signal is in the form of a coherent (laser) beam that can be collected through small windows. Incoherent (non-CARS) interferences are rejected by spatial filtering.

Diskin, G. S.↗

Experimental evaluation of a TF30-P-3 turbofan engine in an altitude facility: Effect of steady-state temperature distortion

The effects of circumferential distortion of the total temperature entering 25, 50, and 75 percent of the inlet circumferential annulus of a turbofan engine were determined. Complete compressor stall resulted from distortions of from 14 to 20 percent of the face averaged temperature. Increasing the temperature level in one sector resulted in that sector moving toward stall by decreasing the equivalent rotor speeds while the pressure ratio remained approximately constant. Stall originated as a rotating zone in the low-pressure compressor which resulted as a terminal stall in the high-pressure compressor. Decreasing the Reynolds number index to 0.25 from 0.5 reduced the required distortion for stall by 50 percent for the conditions investigated.

Braithwaite, W. M.↗

Preliminary results of large supersonic burning combustor testing.

A hydrogen fueled supersonic-burning combustor 18 in. in diameter, which is equivalent to that of an engine about 6 ft in diameter, was tested as a direct-connected duct at inlet conditions which simulated Mach 8 flight at 115,000 ft alt. A synthetic air consisting of oxygen with 39% nitrogen and 38% water vapor at a total temperature of 4500 deg R and a total pressure of 300 psia was supplied to the combustor inlet by a hydrazine-nitrogen tetroxide hot gas generator which maintained a uniform inlet flow Mach number of 2.8. The large combustor size required a new approach to fuel injector design. Some hydrogen was injected through flush-wall injectors, but most was injected from two rows of swept and tapered struts immersed in the flow stream. Supersonic combustion was obtained at hydrogen equivalence ratios of 0.94 without encountering thermal cho king. Wall static pressures, and the radial distribution of hydrogen, Pitot pressure, and Mach number were determined at the combustor exit.

Metzler, A. J.↗

Reynolds number tests of an NPL 9510 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

An investigation of the NPL 9510 airfoil was conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel over the following ranges of test conditions: Mach number of 0.35 to 0.82, total temperature of 94 K to 300 K, total pressure of 1.20 to 5.81 atm, Reynolds number based on airfoil chord of 1.34 x 10 to the 6th power to 48.23 x 10 to the 6th power, and angle of attack of 0 deg to 6 deg. The drag creep previously reported by the British National Physics Laboratory at low Reynolds numbers was also found to be present at high Reynolds numbers; the section drag coefficient continued to decrease even at the highest Reynolds number tested. Tests made close to free-stream saturation did not produce altered aerodynamic coefficients due to condensation effects.

Jenkins, R. V.↗